Effects of Moisture Content in Concrete on Diffuse Ultrasound (확산초음파의 콘크리트 함수율에 대한 의존성)

  • Ahn, Eunjong;Shin, Myoungsu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.142-147
    • /
    • 2020
  • This study investigates the effects of moisture content on diffuse ultrasound to be applied for the evaluation of micro-structural damage in concrete subjected to various environmental conditions. We monitored diffuse wave parameters for concrete samples in process of water saturation for 5 days. Dried samples were immersed in a water bath, and the change of moisture content in concrete were estimated by measuring the change of mass. For the diffuse wave analysis, a frequency range of 500 kHz, which represents a scattering regime of ultrasound in concrete, was selected. The test results reveal that the ultrasonic diffusivity slightly changed, and the ultrasonic dissipation significantly increased by approximately 120% in the process of water saturation. Therefore, the moisture content in concrete should be considered for the evaluation of micro-structural damage using diffuse wave techniques.

A Study on the Resistance Against Environmental Loading of the Fine-Size Exposed Aggregate Portland Cement Concrete Pavements (소입경 골재노출콘크리트포장의 환경하중 저항성에 대한 연구)

  • Chon, Beom-Jun;Lee, Seung-Woo;Chae, Sung-Wook;Bae, Jae-Min
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.99-109
    • /
    • 2009
  • Fine-size exposed aggregate portland cement concrete pavements (FEACP) have surface texture of exposed aggregate by removing upper 2$\sim$3mm mortar of surface of which curing is delayed by using delay-setting agent. FEACPs have advantages of maintaining low-noise and adequate skid-resistance level during the performance period than general portland cement concrete pavements. It is necessary to ensure the durability environmental loading to prevent unexpected distress during the service life of FEACP. In the process of curing, volume change accompanied change in by moisture and temperature could be an important cause of crack in concrete to construct for successful FEACP, The use of chloride containing deicer may accelerate defects of concrete pavement, such as crack and scaling. This study aim to evaluate environmental loading resistance of FEACP, based on the estimation of shrinkage-crack-control-capability by moisture evaporation and scaling by deicer in freeze-thaw reaction.

  • PDF

A Study on the Durability Improvement of Highway-Subsidiary Concrete Structure Exposed to Deicing Salt and Freeze-Thaw (동결융해 및 제설제에 노출된 고속도로 소구조물 콘크리트의 내구성 개선 연구)

  • Lee, Byung-Duk;Choi, Yoon-Suk;Kim, Young-Geun;Choi, Jae-Seok;Kim, Il-Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.128-135
    • /
    • 2016
  • In the current concrete structure of the highway is still the major problem most of concrete deterioration caused by the freeze-thaw and deicing salt, which is of issues that are not completely resolved. In particular, a single freezing event does not cause much harm, durability of concrete under multi-deterioration environment by repeated freeze-thaw and deicing salt is rapidly degraded and reduce its service life. In this study, the exposure environmental condition according the regional highway points were established. The damage condition and chloride content of the concrete at general and severe environmental exposure condition were also investigated. In addition, the experimental test of chloride ion permeability, scaling resistant and freeze-thaw resistance were carried out to improve the durability of the mechanical placing concrete of subsidiary structure. According to the results of this study, in observation of concrete surface condition, the concrete exposed by severe environmental condition showed broad ranges of damage with high chloride contents. Meanwhile, the water-binder(W/B) ratio and the less water content, and fly ash concrete than the specified existing mix proportion is significantly improved the durability. Also, the optimal mix proportion derived for test is satisfied the strength and air contents, water-binder ratio, and durability criteria of concrete specifications, as well as service life seems greatly improved.

NOx-removal and Sound-absorption Performances of Photocatalytic Porous Concrete Prepared by Various TiO2 Application Methods (TiO2 적용방법에 따른 포러스 콘크리트의 질소산화물 제거성능 및 흡음특성)

  • Yoon, Hyunno;Seo, Joonho;Kim, Seonhyeok;Jang, Daeik;Bae, Jinho;Lee, Haeng-Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.163-170
    • /
    • 2022
  • The present study investigates NOx-removal and sound-absorption performances of photocatalytic porous concrete prepared by various TiO2 application methods. Photocatalytic porous concrete samples were prepared by one of the following: 1) mechanically mixing TiO2 during casting; 2) mixing bottom ash aggregate pretreated with TiO2 during casting; and 3) spraying TiO2 solution to the normally fabricated porous concrete. The test results indicated that the mechanical mixing of TiO2 decreased the compressive strength as the added TiO2 content increased. The use of pretreated bottom ash aggregate reduced the porosity, yet the compressive strength of the concrete was similar to that measured from the former method. Porous concrete samples sprayed with the TiO2 solution exhibited enhanced compressive strength, while the porosity was analogous to those measured from other methods. The NOx-removal performance was the highest in the samples sprayed with the TiO2 solution, followed by the samples using pretreated bottom ash aggregate and mechanically mixed TiO2. The samples with mechanically mixed TiO2 identified a relationship between soundabsorption performance and porosity. However, no particular tendency was observable in the samples with other TiO2 application methods.

Investigation of Microstructural Characteristics of Foamed Concrete with Different Densities (미세구조 분석방법을 활용한 서로 다른 밀도를 가진 기포콘크리트 특성 분석)

  • Chung, Sang-Yeop;Jo, Su-Sung;Oh, Seo-Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • A set of foamed concrete specimens with different densities were prepared, and several microscopic techniques, such as scanning electron microscope (SEM) and X-ray micro-computed tomography (micro-CT) were used to characterize the foamed specimens. The pore and solid characteristics of the specimens at different ages were examined to investigate the effect of aging on the materials. The compressive strength and the thermal conductivity of the foamed specimens were also evaluated, and the relationship between the material characteristics and properties was integrated to identify the effect of density and aging on the material properties.

Mix Proportions of Early-Strength Pavement Concrete Using Calcium Nitrate (질산칼슘 혼화재를 사용한 신속개방형 포장 콘크리트의 적정배합비 도출)

  • Won, Jong Pil;Lee, Si Won;Lee, Sang Woo;Park, Hae Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.95-100
    • /
    • 2009
  • This study proposed mix proportions of early strength pavement concrete for large size area using calcium nitrate. Therefore, we used type III cement with calcium nitrate. Laboratory tests conducted to air content, slump loss test, setting time test, compressive strength test and flexural strength test. Our early strength pavement concrete mixture proportion proposed in this study for large size area attained the required compressive strength of 21 MPa and a flexural strength of 3.8 MPa, which allowed it to be opened to traffic within 8 hours. Based on test results, we suggested optimum mix proportions of early strength pavement concrete for large size area using calcium nitrate.

Influence of Water-Cement Ratios and Curing Conditions on the Diffusion Characteristics of Chloride Ion in Concrete (콘크리트의 염소이온 확산특성에 미치는 물-시멘트비 및 양생조건의 영향)

  • Bae, Su-Ho;Lee, Kwang-Myong;Kim, Jee-Sang;Jung, Sang-Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.753-759
    • /
    • 2006
  • To predict service life of concrete structures exposed to chloride attack, surface chloride concentration, diffusion coefficient of chloride ion, and chloride corrosion threshold value in concrete, are used as important factors. Of these, as the diffusion coefficient of chloride ion for concrete is strongly influenced by concrete quality and environmental conditions of structures and may significantly change the service life of structures, it is considered as the most important factor for service life prediction. The qualitative factors affecting the penetration and diffusion of chloride ion into concrete are water-cement (W/C) ratio, age, curing conditions, chloride ion concentration of given environment, wet and dry conditions, etc. In this paper the influence of W/C ratio and curing conditions on the diffusion characteristics of chloride ion in concrete was investigated through the chloride ion diffusion test. In the test, the voltages passing through the diffusion cell were measured by accelerated test method using potential difference, and then with the consideration of IR drop ratio the diffusion coefficient of chloride ion for concrete with different W/C ratios were estimated by Andrade's model. Furthermore, under different curing conditions formulas for the estimation of the diffusion coefficient of chloride ion have been proposed by the regression analysis considering the effect of W/C ratio and age.