• Title/Summary/Keyword: 환경측정기

Search Result 235, Processing Time 0.033 seconds

Performance verification methods of an inertial measurement unit in flight environment using the real time dual-navigation (실시간 다중항법을 이용한 관성측정기의 비행환경 성능 검증 기법)

  • Park, ByungSu;Lee, SangWoo;Jeong, Sang Mun;Han, KyungJun;Yu, Myeong-Jong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.1
    • /
    • pp.36-45
    • /
    • 2017
  • Abstract It is necessary to verify the properties of an inertial measurement unit in the flight environment before applying to military applications. In this paper, we presented a new approach to verify an inertial measurement unit(IMU) in regard to the performance and the robustness in flight environments for the high-dynamics vehicle systems. We proposed two methods for verification of an IMU. We confirmed normal operation of an IMU and properties in flight environment by using direct comparison method. And we proposed real time multi-navigation system to complement the first method. The proposed method made it possible to compare navigation result at the same time. Therefore, it is easy to analyze the performance of an inertial navigation system and robustness during the vehicle flight. To verify the proposed method, we carried out a flight test as well as an experimental test of flight vibration on the ground. As a result of the experiment, we confirmed flight environment properties of an IMU. Therefore, we shows that the proposed method can serve the reliability improvement of IMU.

A Study on the Correlation with the Degree of Compaction and the Penetration Depth Using the Portable Penetration Meter at Field Test (휴대용 다짐도 측정기의 현장실험을 통한 다짐도와 관입깊이 상관성 연구)

  • Park, Geoun Hyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.11
    • /
    • pp.5-14
    • /
    • 2018
  • Worldwide, soil compaction work is one of the most important activities that are carried out on civil engineering works sites. Compaction work, particularly in the area of road construction, is considered to be important, as poor compaction work is closely related with poor construction even after a construction is complete. Currently, the plate bearing test or the sand cone method relative to the unit weight of soil test are commonly used to measure the degree of compaction, but as these require a great deal of time, equipment and manpower, it is difficult to secure economic efficiency. The method that is used to measure the degree of compaction according to the penetration depth achieved by free fall objects through gravity is the Free-Fall Penetration Test (FFPT), which uses a so-called "portable compaction measuring meter (PCMM)." In this study, the degree of compaction was measured and a penetration depth graph was developed after the field test using the portable compaction measuring meter. The coefficient of determination was 0.963 at a drop height of 10 cm, showing the highest level of accuracy. Both horizontal axis and longitudinal axis were developed in a decimal form of graph, and the range of allowable error was ${\pm}1.28mm$ based on the penetration depth. The portable compaction measuring meter makes it possible to measure the degree of compaction simply, quickly and accurately in the field, which will ensure economic efficiency and facilitate the process management.

Design of the Ground Resistance Measuring System using high Performance Filter System (고성능 필터를 이용한 접지저항 측정시스템의 설계)

  • 이기홍;정재기;주형준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.43-48
    • /
    • 2001
  • This paper represents the design of the ground resistance measuring system insensitive to the noise in the earth. Generally, conventional ground resistance measuring instruments may fail to give a precise values for ground resistance under the situations where there is a high ground potential produced by unbalanced power system currents, haromonic currents and noise etc. To make up the defect of conventional ground resistance measuring instruments, in this paper the ground resistance measuring system using high-performance L-C resonant filter and digital signal processor is designed and the insentivity of the designed ground resistance measuring system for noise in the earth is verified by field test on power service and off power service.

  • PDF

The Determination of Temperature and Humidity Sensitivity Coefficients of Torque Transducers using Seasonal Climatic Changes of Ambient Conditions in the Laboratory (계절에 따른 실험실 환경변화를 이용한 토크측정기의 온도 및 습도 감도계수 결정)

  • Derebew, Mulugeta;Kim, Min Seok;Park, Yon Kyu;Lee, Ho Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.185-190
    • /
    • 2015
  • This paper presents a new method to determine sensitivity coefficients of temperature and humidity of torque transducers by using a natural and seasonal variation of ambient conditions at the laboratory. We had measured the sensitivities of the torque transducers over almost one year using the KRISS 2 kN m torque standard machine. The sensitivity data acquired at various ambient conditions were processed using our measurement model to extract the sensitivity coefficients of temperature and humidity simultaneously with high precision. A comparison with a previous method using an environmental control chamber was carried out to test the feasibility of using our new method. Two results agreed within the uncertainty. We revealed that the torque measuring errors could be 8 times higher than the measurement and calibration capability of KRISS torque standard machine if the sensitivity changes due to the temperature and humidity are not properly corrected during a calibration.

Quantitative Analysis for Surface Recession of Ablative Materials Using High-speed Camera and 3D Profilometer (초고속 카메라와 삼차원 표면 측정기를 이용한 삭마 재료의 정량적 표면 침식 분석)

  • Choi, Hwa Yeong;Roh, Kyung Uk;Cheon, Jae Hee;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.735-741
    • /
    • 2018
  • In this paper, the surface recession of ablative materials was quantitatively analyzed using a high-speed camera and a three-dimensional profilometer. The ablation tests of the graphite and carbon/phenolic composite samples were performed using a 0.4 MW arc-heated wind tunnel for simulating the atmospheric re-entry environment. The real-time images during the ablation test were captured by the high-speed camera, and analyzed to calculate the surface recession and recession rate. Also, the surface data of samples were obtained using a three-dimensional profilometer, and the surface recession was precisely calculated from the difference of height between the surface data before and after the test. It is effective to complement the two measurement results in the comprehensive analysis of surface recession phenomena.

Analysis of Performance of Multi-functioned frictional force measuring instrument using adaptive smoothing (적응화 평활화법을 이용한 다기능 마찰력 측정기의 성능 분석)

  • Kim, Tae-Soo;Kim, Gwang-Su
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.2
    • /
    • pp.113-119
    • /
    • 2019
  • We have developed the multi-functioned friction measuring instrument for the previous research. In here, we improved the performance of friction measuring instrument by applying the adaptive smoothing method and analyzed the friction of plate and monitoring function of friction surface through scratch tests. We substituted lubricant steel plate to lubricant oil used for reducing the friction when fabricating steel plate because lubricant oil was regarded as one of the major causes for the environmental pollution. In particular, the functions of various plate such as galvannealed steel sheets were analyzed because friction coefficient could be changed depending on the type of organic/inorganic plate or state of coating layer. Therefore, we demonstrated that adaptive smoothing method could enhance the accuracy of measuring instrument which eliminate the noise. As a result of using the method, it showed the reduction rate 0.0417% for the friction coefficient 0.16.