• Title/Summary/Keyword: 환경유지유량

Search Result 347, Processing Time 0.021 seconds

A Study on Space Creation and Management Plan according to Characteristics by Type in Each Small-Scale Biotope in Seoul - Base on the Amphibian Habitats - (서울시 소규모 생물서식공간 유형별 특성에 따른 조성 및 관리방안 연구 - 양서류 서식지를 중심으로 -)

  • Park, Ha-Ju;Han, Bong-Ho;Kim, Jong-Yup
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.52 no.2
    • /
    • pp.110-126
    • /
    • 2024
  • This study conducted a classification of small-scale biological habitats created in Seoul to analyze and synthesize location characteristics, habitat structure, biological habitat functions, and threat factors of representative sites, as well as derive creation and management problems according to the ecological characteristics. The aim was to suggest improvement measures and management items. Data collected through a field survey was used to categorize 39 locations, and 8 representative sites were selected by dividing them into location, water system, and size as classification criteria for typification. Due to the characteristics of each type, the site was created in an area where amphibian movement was disadvantageous due to low or disconnected connectivity with the hinterland forest, and the water supply was unstable in securing a constant flow and maintaining a constant water depth. The habitat structure has a small area, an artificial habitat structure that is unfavorable for amphibians, having the possibility of sediment inflow, and damage to the revetment area. The biological habitat function is a lack of wetland plants and the distribution of naturalized grasses, and threats include the establishment of hiking trails and decks in the surrounding area. Artificial disturbances occur adjacent to facilities. When creating habitats according to the characteristics of each type, it was necessary to review the possibility of an artificial water supply and introduce a water system with a continuous flow in order to connect the hinterland forest for amphibian movement and locate it in a place where water supply is possible. The habitat structure should be as large as possible, or several small-scale habitats should be connected to create a natural waterfront structure. In addition, additional wetland plants should be introduced to provide shelter for amphibians, and facilities such as walking paths should be installed in areas other than migration routes to prevent artificial disturbances. After construction, the management plan is to maintain various water depths for amphibians to inhabit and spawn, stabilize slopes due to sediment inflow, repair damage to revetments, and remove organic matter deposits to secure natural grasses and open water. Artificial management should be minimized. This study proposed improvement measures to improve the function of biological habitats through the analysis of problems with previously applied techniques, and based on this, in the future, small-scale biological habitat spaces suitable for the urban environment can be created for local governments that want to create small-scale biological habitat spaces, including Seoul City. It is significant in that it can provide management plans.

Estimation of Optimal Size of the Treatment Facility for Nonpoint Source Pollution due to Watershed Development (비점오염원의 정량화방안에 따른 적정 설계용량결정)

  • Kim, Jin-Kwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.149-153
    • /
    • 2008
  • The pollutant capacity occurred before and after the development of a watershed should be quantitatively estimated and controlled for the minimization of water contamination. The Ministry of Environment suggested a guideline for the legal management of nonpoint source from 2006. However, the rational method for the determination of treatment capacity from nonpoint source proposed in the guideline has the problem in the field application because it does not reflect the project based cases and overestimates the pollutant load to be reduced. So, we perform the standard rainfall analysis by analytical probabilistic method for the estimation of an additional pollutant load occurred by a project and suggest a methodology for the estimation of contaminant capacity instead of a simple rational method. The suggested methodology in this study could determine the reasonable capacity and efficiency of a treatment facility through the estimation of pollutant load from nonpoint source and from this we can manage the watershed appropriately. We applied a suggested methodology to the projects of housing land development and a dam construction in the watersheds. When we determine the treatment capacity by a rational method without consideration of the types of projects we should treat the 90% of pollutant capacity occurred by the development and to do so, about 30% of the total cost for the development should be invested for the treatment facility. This requires too big cost and is not realistic. If we use the suggested method the target pollutant capacity to be reduced will be 10 to 30% of the capacity occurred by the development and about 5 to 10% of the total cost can be used. The control of nonpoint source must be performed for the water resources management. However it is not possible to treat the 90% of pollutant load occurred by the development. The proper pollutant capacity from nonpoint source should be estimated and controlled based on various project types and in reality, this is very important for the watershed management. Therefore the results of this study might be more reasonable than the rational method proposed in the Ministry of Environment.

Evaluation of Water Quality Characteristics on Tributaries of Dongjin River Watershed (동진강 유역내 하천의 특성별 영향평가)

  • Yun, Sun-Gang;Kim, Won-Il;Kim, Jin-Ho;Kim, Seon-Jong;Koh, Mun-Hwan;Eom, Ki-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.4
    • /
    • pp.243-247
    • /
    • 2002
  • Irrigation water quality along Donjin river watershed was monitored to find a possible pollutant, for maintaining water quality to achieve food safety through water quality preservation of river. As a pollution indicators, such as Biological Oxygen Demand(BOD), Chemical Oxygen Demand(COD), Total Nitrogen(T-N), and Total Phosphate(T-P) in Dongjin river were examined from May to November in 2001. The results were as follows : The BOD level of Dongjin river ranged from 2.84 to 6.45 mg/L, which would be in a II$\sim$IV grade of the potable water criteria by Ministry of Environment. Averaged BOD level of downstream DJ6(After Jeongupcheon confluence) was 4.07 mg/L. The average COD level of Dongjin river ranged from 11.20 to 32.96 mg/L. COD level of DJ6 rapidly increased rapidly after the junction of Dongjin river and Jungupcheon because it showed the latter had relatively high pollution level. T-N content were significantly high in all sites of Dongjin river ranged through 4.16 to 5.84 mg/L. T-P examined high concentration than another thing point by 0.19 mg/L after Jeongupcheon confluence as BOD and COD. COD of main stream was expressed high concentration to dry season after rainy season. In case of T-P, pollution degree of dry season before rainy season appeared and examined that quality of water was worsened go by dry season after rainy season. The water quality of Dongjin river was deteriorated with inflow of Jungupcheon polluted by municipal and industrial sites near Jungup city.

Effects of Sprinkler and Fan Cooling System in Loose Barn on the Physiological Parameter and Milk Productivity in Holstein Cows During Summer (개방식우사내 Fan과 Sprinkler설치가 착유우의 생리적 변화 및 유생산성에 미치는 영향)

  • 정태영;이현민;김종민;김동일;이연섭;이인형
    • Journal of Animal Environmental Science
    • /
    • v.2 no.1
    • /
    • pp.41-52
    • /
    • 1996
  • This experiment was carried out to study the effect of sprinkler and fan cooling system on the physiological parameter, milk production and milk composition for Holstein cows in hot, humid climates. Thirty cows were assigned to one of two sections of open-sided loose barn. Water nozzles of sprinkler system were spaced in line at 1.2m intervals. Forced air was provided by 85cm diameter fans at rate of 3.4㎥/sec. The results obtained from these experiments are as follows: 1. There was no significant difference in meteorological data between control and fan + sprinkler cooling system(treatment group). 2. Skin temperature and rectal temperature of the treatment group were significantly lower than those of the control group (32.96 : 39.53$^{\circ}C$ vs 34.02 : 41.21$^{\circ}C$ respectively) (P<0.05). 3. Serum cortisol concentration of the treatment group(0.90$\mu\textrm{g}$/dL) was lower than that of control group(1.44$\mu\textrm{g}$/dL)(P<0.05). 4. Milk production of cows cooled with a sprinkler and fan cooling system was significantly higher than that of no cooling system (P<0.0l). 5. Lactose, protein and solid-not-fat content of milk were not changed by the treatments. Milk fat content of the control(3.23%) was low compared with the treatment group(3.38%). Somatic cell count was reduced by 26.63% in the treatment. The results indicate that a sprinkler and fan cooling systems can provide an effective means to relieve heat stress and enhance productivity of lactating Holstein cows during hot and humid summer season.

  • PDF

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

Evaluation on Functional Assessment for Fish Habitat of Underground type Eco-Artificial Fish Reef using the Index of Biological Integrity (IBI) and Qualitative Habitat Evaluation Index (QHEI) (생물보전지수(IBI) 및 서식지 평가지수(QHEI)를 활용한 지하 매립형 방틀둠벙의 어류 서식처 기능 평가)

  • Ahn, Chang Hyuk;Joo, Jin Chul;Kwon, Jae Hyeong;Song, Ho Myeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6B
    • /
    • pp.565-575
    • /
    • 2011
  • The purpose of this study was to quantitatively evaluate the expression of both multi-metric qualitative habitat evaluation index (QHEI) and biological integrity index (IBI) for artificial structures eco-artificial fish reef (EAFR) for fishes asylum and habitat. Especially, both experimental evaluation and biological verification were performed in Water and Environmental Center's outdoor test-bed of Korea Institute of Construction Technology located in Andong-city, Gyeongsangbuk-do. The experimental conditions reflecting the situation of domestic river include the flow rate (e.g., $0.0{\sim}1.5m\;s^{-1}$), the width (e.g., 1.0~3.0 m), the depth (e.g., 0.05~0.70 m), and variable bed materials. Both QHEI and IBI were monitored for 8 months from May to December 2010. Whereas QHEI values were highest at experimental points of the E~F with an average of 83.1, those were lowest at B~C with an average of 78.1. However, QHEI values inside EAFR were more than 98.9, regardelss of space and time, and indicated more than the highest good of the state (Good) in the habitat. Overally, IBI values showed similar trend with QHEI, but were 44.2 in the winter dry season, compared to 32.8 of QHEI values. IBI values Also, IBI values inside EAFR were greater than those at the experimental channel by 5.7 to 11.4% and 18.7 to 34.8% in flow and stagnant conditions, respectively, indicating that EAFR can secure asylum and habitat for fish during the dry season. For comprehensive aquatic ecosystem assessment, the experimental channel showed generally fair conditions (Fair~Good), whereas EAFR showed good conditions (Good), suggesting that EAFR can be applied to aquatic ecosystem restoration and improvement.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF