• Title/Summary/Keyword: 확인시험

Search Result 8,152, Processing Time 0.042 seconds

A Study of Testing Procedure Temperature of Electronic Equipment for Railway Environments (Cold and Heat) (철도용 전자기기의 온도환경(내한성, 내열성)에 대한 시험검사 절차에 대한 분석연구)

  • Kim, Jin-Hwan;Yang, Doh-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.748-753
    • /
    • 2011
  • Generally, in the temperature and environment test of railway electronics, cold and heat resistant tests are involved. Relevant KRS standards describe "There is no problem" as acceptance criteria for function check during the temperature and environment tests. According to this requirement, testers perform some function and performance tests which are easy to perform during test procedure using temperature chamber. This paper reviews the limit of current check method for cold and heat resistant tests and proposes an alternative. An alternative is the application of data sheet. Using data sheet, the temperature of equipped components is checked whether this temperature meet acceptance criteria or not. Also, this paper suggests temperature test range guidelines comparing temperature standards for general IC component. For the example in real field, this method uses the lowest temperature and the highest temperature in major domestic cities.

  • PDF

Indirect Verification of the Icing Test Condition Using Ice Thickness (얼음두께를 이용한 결빙시험조건의 간접 확인기법)

  • Kim, Yoo Kyung;Park, Nameun;Choi, Gio
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.11
    • /
    • pp.944-951
    • /
    • 2018
  • Artificial icing test and wind tunnel test can be performed to reduce the development period when a rotorcraft is required operation under icing situations. Artificial icing test of the KUH(Korean Utility Helicopter) was performed in advance to verify anti-icing and de-icing performance before natural icing test. Although high-precision sensor, the CCP(Cloud Combination Probe) is used to measure icing test condition parameters such as LWC(Liquid Water Content) and MVD(Median Volume Diameter), the measured values need to be verified in various methods due to the possibility of uncertainties which are the test atmosphere environment, sensor errors, and etc. The calculated LWC from the ice thickness cumulated on the fuselage of the KUH is compared to the measured value by CCP, and the results show the effective indirect method to check the test conditions.

콘크리트 확장형 앵커의 동적검증

  • 김상윤;윤철호;최강룡
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.339-345
    • /
    • 1996
  • 배관 및 기기 등의 지지부 정착에 사용되는 확장형 앵커는 여러 종류의 진동하중을 받게 되므로 그러한 하중에 대한 동적저항능력이 시험에 의하여 확인되어야 한다. 확장형 앵커의 동적시험 요건이 ASTM E488에 기술되어 있으나 내진시험 입력, 피로전단시험 입력 등 일부 요건이 구체적으로 명시되어 있지 않아 시험기관에 따라 시험조건이 자의적으로 결정될 수 있다. 따라서, 본고에서는 코드 시험요건이 구체적이지 못한 사항을 조사하여 적정 요구수준을 제시하였다. 또한, 국내에서 수행된 동적시험내용 검토결과, 현행 동적설계방안의 일부보완이 필요함을 확인하였다.

  • PDF

저궤도 지구관측위성 비행모델 정현파 가진시험 결과 분석

  • Kim, Gyeong-Won;Kim, Chang-Ho;Im, Jae-Hyeok;Kim, Won-Seok;Kim, Seon-Won;Hwang, Do-Sun
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.32.1-32.1
    • /
    • 2011
  • 이 논문에서는 저궤도 지구관측위성 비행모델의 정현파 가진시험 결과에 대하여 분석하였다. 정현파 가진시험은 발사환경시험중의 하나로서, 저주파 대역의 정현파 진동 환경하에서 인공위성의 안정성을 검증하는데 그 목적이 있다. 정현파 가진시험의 입력선도는 발사체로부터 선정되어진다. 발사체로부터 선정된 입력선도는 극한의 경우를 고려한 선도이므로 실제 정현파 가진시험시에는 입력선도에 적절한 노칭을 적용하여야 한다. 노칭은 주구조물의 대한 1차 노칭과 부가 구조물에 대한 2차 노칭으로 구분이 되어 적용되었다. 정현파 가진시험의 전후에는 저수준 정현파가진시험을 수행하였으며, 주파수 응답함수를 비교함으로서 구조적으로 문제가 없는지를 확인하였다. 시험 후, 육안검사를 통하여 구조 부재가 이상이 없는지를 최종 확인하였으며, 인공위성비행모델이 정현파 가진 환경하에서 충분히 안전함을 확인하였다.

  • PDF

가압공급 방식 액체로켓 엔진 연소 성능 및 수류시험

  • 조남경;이수용;한영민;고영성;정용갑;김영한;문일윤
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.9-9
    • /
    • 2000
  • 우주추진기관의 모든 부품은 생산 시 규정된 절차를 거쳐서 작동의 이상유무를 확인하는 시험을 거친다. 우주추진기관은 특별한 경우를 제외하고는 실 비행 상태에서 시험하기가 어렵거나 불편하기 때문에 지상에서 시험을 수행하여 성능 및 안정성 등을 확인하게 된다. 지상연소시험을 수행하기 위해서는 비행용 엔진을 대상으로 엔진 메니폴드에 비행 시와 같은 조건의 추진제가 공급될 수 있게 해줘야 한다. 기존에 시험장이 이미 구축되어 있는 경우 엔진의 운용조건에 맞추어 엔진에 맞게 엔진과 시험설비 연결부분이 수정되게 된다.(중략)

  • PDF

A Study on the QE and Methodology of System Improvement for Mobile Communications Service (국내 이동통신 사업자의 이동전화 서비스 품질평가 제도에 관한 연구)

  • 이동철;김기문
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.6
    • /
    • pp.1031-1037
    • /
    • 2001
  • 본 고에서는 요즘 전세계적으로 관심을 모으고 있는 정보통신 산업과 기술발전으로 인한 이동전화의 서비스 품질평가에 대한 방법을 정리하였다. 주요 내용으로는 이동전화 체감 통화품질 측정을 위한 시험조건 및 시험방법개선, 시험장비 기능 확인시험, 성능개선 요구 및 확인, 시험계획 수립 및 전국 측정 방법, 측정데이터 분석, 등급별 평가 등에 대한 내용으로, 특히 이동전화 품질평가 항목별 시험조건 및 시험방법, 이동전화 체감 품질 측정용 시험장비 성능/신뢰성 개선 그리고 전국 현장 측정 데이터분석 및 지역별 품질 산출, 등급별 평가 내용을 정리하였다. 또한 각 분야별 품질 평가 기술 방법에 패한 우리나라의 대응전략을 정리하여 산업체 기술개발에 많이 활용될 수 있을 것으로 사료된다.

  • PDF

A Study on the QE and Methodology of System Improvement for Mobile Communications Service (이동전화 통화품질 측정에 관한 연구)

  • 정인명;이동철;김기문
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.419-425
    • /
    • 2001
  • 본 고에서는 요즘 전세계적으로 관심을 모으고 있는 정보통신 산업과 기술발전으로 인한 이동전화의 서비스 품질평가에 대한 방법을 정리하였다. 주요 내용으로는 이동전화 체감 통화품질 측정을 위한 시험 조건 및 시험방법개선, 시험장비 기능 확인시험, 성능개선 요구 및 확인, 시험계획 수립 및 전국 측정 방법, 측정데이터 분석, 등급별 평가 등에 대한 내용으로, 특히 이동전화 품질평가 항목별 시험조건 및 시험 방법, 이동전화 체감 품질 측정용 시험장비 성능/신뢰성 개선 그리고 전국 현장 측정 데이터분석 및 지역별 품질산출, 등급별 평가 내용을 정리하였다. 또한 각 분야별 품질 평가 기술 방법에 대한 우리나라의 대응전략을 정리하여 산업체 기술개발에 많이 활용될 수 있을 것으로 사료된다.

  • PDF

A Blockchain-Based Cheating Detection System for Online Examination (블록체인 기반 온라인 시험 부정행위 탐지 시스템)

  • Nam, Goo Mo;Park, Ji Su;Shon, Jin Gon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.6
    • /
    • pp.267-272
    • /
    • 2022
  • Online exams are not limited by time and space. It has the advantage that it does not require a separate exam site for examinees, and there is no time and cost required to move to the exam site. However, the online exam has the disadvantage that various cheating is possible because the exam is conducted in an individual environment. In addition, there is a difficulty in detecting cheating due to the lack of exam supervision methods. In addition, since the exam process and result data exist only as digital data, it is inconvenient to check directly on the server where the exam result is stored in order to check whether the exam result is forged or not. If the data related to the exam is maliciously changed, the authenticity cannot be verified. In this study, we tried to increase the reliability of the online exam by developing a blockchain-based online exam cheating detection system that stores exam progress-related data in the blockchain to detect cheating. Through the experiment, it was confirmed that forgery and falsification are detected as a result of the exam.

Comparison of Standard Culture Method and Real-time PCR Assay for Detection of Staphylococcus aureus in Processed and Unprocessed Foods (가공식품과 비가공식품에서의 황색포도상구균 검출을 위한 배지법과 Real-time PCR법의 비교)

  • Lee, Jae-Hoon;Song, Kwang-Young;Hyeon, Ji-Yeon;Hwang, In-Gyun;Kwak, Hyo-Sun;Han, Jeong-A;Chung, Yun-Hee;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.30 no.3
    • /
    • pp.410-418
    • /
    • 2010
  • Staphylococcus aureus is one of the major pathogens that can cause staphylococcal infection and food poisoning. In this study, we compared conventional culture methods and real-time PCR for detection of S. aureus in artificially inoculated milk, sausage, raw pork, and vegetable salad. The performance of a coagulase test for confirming S. aureus was also compared with a colony PCR test. Bulk food samples (500 g each) were artificially inoculated with S. aureus and divided into 20 samples (25 g or mL each). All samples were added to tryptic soy broth (225 mL/sample) with 10% NaCl and incubated at $37^{\circ}C$ for 24 h. After the enrichment, broth cultures were streaked onto Baird-Parker (BP) agar with egg yolk tellulite, and incubated at $37^{\circ}C$ for 24 h. In addition, 1 mL of broth cultures was collected to perform real-time PCR. Two suspicious colonies from the BP agar were picked up and plated on nutrient agar and incubated at $37^{\circ}C$ for 24 h followed, by a coagulase confirmation test and a colony PCR analysis. There were no statistical differences between culture methods and realtime PCR in food samples with low background microflora, such as milk and sausage. However, a significant statistical difference was found between the culture methods and real-time PCR for raw pork and vegetable salad. Furthermore, the colony PCR test of the presumptive colonies on BP agar for confirming S. aureus is more accurate and efficient than the coagulase test for unprocessed foods.

Determination of fluorine in Krill oils by combustion-ion chromatography (연소-이온크로마토그래프를 이용한 크릴오일 중 불소 시험법)

  • Jung, Jaehak;Kim, Soobin;Chu, Euisung;Joung, Joungmoo
    • Analytical Science and Technology
    • /
    • v.33 no.6
    • /
    • pp.262-273
    • /
    • 2020
  • A fluorine content analysis method for krill oils, which is a representative oil formulation in foods, was developed in compliance with the Korea Food and Drug Ministry's "Guidelines for Validation of Testing Methods Related to Food". Using this method for krill oils, the presence of impurities was evaluated via combustion-ion chromatography (C-IC). A review of published technical data on fluorine in krill oils showed that while the traditional wet potentiometric method was typically used, it was not reliable. Moreover, there was no food testing/analysis laboratory in Korea to perform a fluorine test analysis on such an oil matrix. Therefore, we identified halogen (fluorine) tests, developed to national and international standards, and developed a test method suitable for krill oils by selecting a C-IC method that is sufficiently applicable to the oil matrix. Based on the characteristics of the oil matrix, the optimal test method was established through various experiments by reviewing the concerns related to loss and interference in the preparation and introduction of samples. The fluorine content test was carried out on 11 krill oil products that were purchased online. Most products (with the exception of only one) were found to contain less than the reporting limit obtained by the test method. Furthermore, after additional testing, a high fluorine content of approximately 2,000 ~ 3,000 mg/kg was detected on the krill surface, although the concentration varied depending on the area of the krill. A comparison with samples from two ISO/IEC 17025 testing laboratories confirmed that there was no significant difference in the statistical analysis results obtained by ANOVA among the three laboratories. A testing guide for fluorine content analysis was completed.