• Title/Summary/Keyword: 확대촬영

Search Result 205, Processing Time 0.025 seconds

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography (디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2012
  • In digital mammography, Exposure factor were automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a increase glandular dose. The purpose of this study was to investigate optimal image quality in digital magnification mammography to decrease radiation exposure of patient dose. Auto mode gives the best image quality however, AGD showed better image quality. Image quality of manual mode passed phantom test and SNR at 55% mAs of auto mode commonly used in the digital magnification mammography. Also it could reduce AGD. According to result, manual mode may reduce the unnecessary radiation exposure in digital magnification mammography.

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

EFFECTS ON THE ENLARGEMENT RATIOS DUE TO CHANGES OF HEAD POSTURE ON LATERAL HEADFILMS (측두 규격방사선사진 촬영시 두부의 위치변화가 확대율에 미치는 영향)

  • Seo, Young-Hun;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.185-194
    • /
    • 2001
  • This study was designed to evaluate the effects of angulation changes of head posture on the enlargement ratios of a lateral headfilm depending on the vortical or horizontal rotation of the objects. A device was constructed to measure regional changes of enlargement ratios. The device was held within the cephalostat and cephalograms recorded at each measured degrees of the device tilting, vertically and horizontally. The enlargement ratios of the horizontal, vertical, and angular measurements on the films taken at each tilted angulations were obtained and compared with those on the films taken without rotation. In summary, the enlargement ratios of the horizontal linear measurements were decreased during horizontal rotations. The enlargement ratios of vortical measurements of the right side on the film were increased and those of the left side were decreased by the horizontal rotations. Enlargement ratios of horizontal measurements were affected further than those of vertical measurements by the same angular changes of the horizontal rotations. Therefore, a disruption of parallelism between the object's midsagittal plane and the film could result in distortion of the image while vertical rotation around the object's porionic axis would not significantly affect the enlargement ratios on the headfilm.

  • PDF

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

담췌관계의 자기공명영상의 최근경향

  • 김명진
    • Proceedings of the KSMRM Conference
    • /
    • 1999.11a
    • /
    • pp.17-18
    • /
    • 1999
  • 최근까지 복부 자기공명영상은 간의 국소병변의 특성을 규명하는 데 가장 많이 사용되어 왔다고 할 수 있다. 그러나, 자기공명영상의 기법과 장비의 발달로 인해 그 적응증이 더욱 확대되어 가는 추세에 있고 , 특히 자기공명담췌관촬영술의 도입과 발전은 복부 자기공명영상의 적응증을 한층 넓히는 데 크게 기여하고 있다. 이와 함께, 2차원 또는 3차원 경사에코기법과 조영제를 병용하여 호흡정지 상태에서 자기공명혈관촬영상을 얻을 수 있게 되어 자기공명담췌관촬영술과 혈관촬영술을 복합하여 다양한 담췌관질환을 평가하는 데 이용하는 빈도가 증가하고 있다. 이 강의 에서는 최근에 널리 사용되는 자기공명담췌혈관촬영술 또는 역동적 역상과의 복합적 사용의 유용성을 돌아보고자 한다.

  • PDF

Cervicography as a Screening Test for Cervical Cancer (자궁경부암 선별 검사에서 자궁경부 확대 촬영술의 이용)

  • Lee, Doo-Jin;Lee, Sung-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.169-180
    • /
    • 1999
  • Background: Uterine cervical cancer is the most common malignant tumor of the women in Korea. This study was undertaken to evaluate the usefulness of the cervicography as a screening test of cervical cancer. Materials and Methods: Cervicography was taken from 482 women at department of obstetrics and gynecology, at Yeungnam University Hospital from March 1, 1998 to October 31, 1999. Of the 482 women, 172 women were exc1uded from the study for various reasons, and 310 women completed the study. Three-hundred and ten women had cervical cytology (Papanicolaou smear), cervicography and colposcopy, and punch biopsy was undertaken if any of the test result was abnormal. Results: The most common age group was 35-39, and 40-44, 45-49 in order and most common reason for having a screening test was regular check for cervical cancer. The mean duration from the last Pap smear was 17.1 months, and 64 women(20.4%) never had any prior screening tests. Of the 310 women, 254 women were categorized as normal or having benign disease such as cervicitis, erosion or metaplasia. Biopsy was taken from 56 patients and the results were 26 chronic cervicitis, 4 mild dysplasia, 6 moderate dysplasia, 2 severe dysplasia, 14 carcinoma in situ and 4 invasive carcinoma. The results of cytology and cervicography were well correlated(p<0.05). The sensitivity and specificity of cytology were 86.7% and 76.9%, respectively and the sensitivity and specificity of cervicography were 56.7% and 96.2%, respectively. False negative rate of cervicography(43.3%) was much higher than those of cytology(13. 3%) (p<0.05), but false positive rate of cervicography(3.8%) was much lower than that of cytology(23.1%) (p<0.05). Conclusion: It seems inappropriate to use cervicography as a single screening test for cervival cancer, but it may be an effective complementary test for cytology to lower the false negative rate of cytology.

  • PDF

Improving and Measures of 4K Split Screen Contents producing for Video Moving Picture (비디오 영상을 4K 화면분할 콘텐츠로 만들기 위한 방안 및 제고)

  • Joo, Heon-Sik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.07a
    • /
    • pp.218-219
    • /
    • 2015
  • 본 논문에서는 스마트폰으로 촬영한 비디오 영상이나 일반 캠코더로 촬영한 비디오 영상을 4K 고화질 콘텐츠로 제작하는 것을 제안한다. 대화면 디스플레이와 고해상도 디스플레이가 점차 확대되면서 고화질 콘텐츠의 필요가 증대됨으로 이에 일반적으로 촬영된 영상을 비디오 편집기법을 이용하여 4K 고화질 해상도의 영상 제작을 제안하다. 하지만 일반 비디오카메라로 촬영한 영상을 4K 콘텐츠로 완전히 적용하기 위해서는 촬영에서 4K 카메라로 촬영하고 편집하면 4K 콘텐츠로 보다 해상도가 높은 콘텐츠를 제작할 수 있다고 사료한다.

  • PDF

A Study on Measurement of Premixed Spray Flame using Cross-correlation PIV (상호상관 PIV를 이용한 예혼합 분무화염의 계측에 관한 연구)

  • Yang Young-Joon;Kim Bong-Hwan
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.259-267
    • /
    • 2005
  • In an attempt to elucidate combustion mechanism or premixed spray flame in detail, both the enlarged photographing, which was performed for spray cross-sectional images of premixed spray flame, and the cross-correlation PIV, which was performed for consecutive time-series images to obtain instantaneous two dimensional flow field, were applied. This study indicated that CW laser as well as pulse laser could be applied for PIV. Furthermore, the results of cross-correlation PIV, which was self-made PIV program, was shown in good agreement with those of PDA. Therefore, it was verified that cross-correlation PIV using CW laser in this study could be effectively used for observing structure of premixed spray flame.