• 제목/요약/키워드: 화학선택성

Search Result 1,008, Processing Time 0.031 seconds

Shape-Selective Catalytic Reactions of Toluene with n-Propylalcohol Over ZSM-5 Zeolites (ZSM-5 제올라이트에서 n-프로필알코올의 톨루엔에 대한 형상 선택적 촉매반응)

  • Han-Yun Lee;Byoung Joon Ahn
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.3
    • /
    • pp.317-326
    • /
    • 1993
  • The acid catalytic reactions of toluene with n-propylalcohol were investigated and the adsorption experiments of dialkylbenzene isomers were carried out at 100$^{\circ}C$ over modified HZSM-5 zeolites. ZSM-5 zeolite was synthesized by the hydrothermal reaction using 4-propylammonium ion, sodium aluminate and colloidal silica etc., and several zeolite catalysts, including H-, K-, Sr-, P-Mg-HZSM-5, H-Y and H-mordenite, were prepared by conventional methods. The main reaction products of toluene with n-propylalcohol over HZSM-5 catalyst include not only xylenes, propyltoluenes, but also ethyltoluenes and high para-selectivity among dialkylbenzene isomers was observed on P-Mg-HZSM-5 zeolite. The diffusion coefficients of various p-dialkylbenzenes are nearly the same, about 1 ${times}$ 10$^{-10}$ cm$^2$/sec and that of m-xylene was about one tenth of o-xylene. These reaction and adsorption characteristics were interpreted in the light of the shape-selectivity related to related to the zeolite pore structure and the zeolitic acidity.

  • PDF

Development of a Portable and Disposable pH Sensor Based on Titanium Wire with High Electrochemical Sensing Performance (우수한 전기화학적 센싱 성능을 지닌 티타늄 와이어 기반의 휴대 및 일회용 pH 센서 개발)

  • Yoon, Eun Seop;Yoon, Jo Hee;Son, Seon Gyu;Kim, Seo Jin;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.700-705
    • /
    • 2021
  • A portable and disposable pH sensor based on Ti wire was successfully developed for monitoring hydronium ion concentrations. A sensing electrode was prepared by electrochemically depositing iridium oxide onto a Ti wire, while a reference electrode was fabricated by coating Ag/AgCl ink on a Ti wire. Combining the two electrodes in the pH sensor enabled the collection of open circuit potential signals when the sensor was immersed in solutions of various pH values. The pH sensor exhibited excellent electrochemical sensing performance in terms of sensitivity, response time, repeatability, selectivity, and stability. To demonstrate point-of-measurement applications, the pH sensor was integrated with a wireless electronic module that could communicate with a mobile application. The portable pH sensor accurately measured pH changes in real samples. The results obtained were consistent with those of using a commercial pH meter.

Advances in Highly Selective Materials for the Separation of Oil-Water (고선택성 유수분리 소재 기술)

  • Uhm, Sunghyun;Choi, Kwang-Soon;Lee, Donghun
    • Applied Chemistry for Engineering
    • /
    • v.30 no.2
    • /
    • pp.141-144
    • /
    • 2019
  • Oil-water separators are commonly used in the oily wastewater treatment for the reuse of water resources. Recently, various approaches have been conducted to design and manipulate the oil-water separator installed with highly functionalized membranes. Membrane technologies should encompass the selectivity, durability, economics and processability of materials, and effective oil water separators be also developed to exhibit the optimal performance of the materials. In this mini-review, we highlight the large scale fabrication of membrane materials and the effective design of oil water separators.

A Survey of the Actual Conditions of Operation and Perceptions of Science Teachers and Students Regarding the 7th Elective-Centered Curriculum of High School Science Subjects (제7차 선택중심 고등학교 과학과 교육과정의 운영 실태와 과학교사 및 학생들의 인식 조사)

  • Choi, Soon-Hwa;Kim, Eun-Suk;Kwon, Oh-Kyoung;Oh, Chang-Ho;Park, Kuk-Tae
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.1
    • /
    • pp.96-106
    • /
    • 2008
  • The purpose of this study was to identify the actual conditions of operation in school and investigate the perceptions of science teachers and students regarding the 7th elective-centered curriculum of high school science subjects. For this study, a questionnaire survey was conducted for the selected subjects including 127 high school science teachers and 763 high school students in their third year who had experienced the 7th elective-centered curriculum. As a result of the study, concerning the way to present the elective subjects of science, many cases were the alternative way and the group-elective way in humanity courses while natural science courses had the alternative way and the free-elective way in most cases. In other words, in many cases, the right of elective was given within a limited range. The result of the investigation on science teachers' perceptions on the elective-centered curriculum was that negative views dominated as a whole. Especially, earth science teachers showed the most negative attitudes. The number of biology and chemistry teachers who supported students' right to opt subjects were lower than that of physics teachers and earth science teachers who were against it. To help students make a right choice, many viewed that the system of the college Scholastic Ability Test should be complemented in order to prevent any disadvantage to each elective subject or that it was necessary to have systematic and realistic career education. As the result of investigating the perception of high school students in their third year regarding the elective-centered curriculum, they were usually not very satisfied with it. As the reason for it, many said the selection right was limited. Many others also expressed that there were lack of public relations and education on subjects and careers. Based on these results, limits still exist in accepting all demands although there are a lot of efforts made to smoothly adjust supply and demand of science teachers as well as students' electives in the field of school. It is considered necessary to come up with counterplan and complements to prevent basic science from being neglected or lower academic achievement in the subject of science from happening, and at the same time to harmoniously deal with supply and demand of science teachers as well as the issues of students' demands given the actual conditions of school.

Chemical Stability Evaluation of Ceramic Materials for Liquid Cadmium Cathode (액체카드뮴음금용 세라믹 소재의 화학적 안정성 평가)

  • Ku, Kwang-Mo;Ryu, Hong-Youl;Kim, Seung-Hyun;Kim, Dae-Young;Hwang, Il-Soon;Sim, Jun-Bo;Lee, Jong-Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.1
    • /
    • pp.23-29
    • /
    • 2013
  • LCC (Liquid cadmium cathode) is used for electrowinning in pyroprocessing to recover uranium and transuranic elements simultaneously. It is one of the core technologies in pyroprocessing with higher proliferation resistance than a wet reprocessing because LCC-cell does not separate TRU from uranium. The crucible which holds the LCC is technically important because it should be nonconducting material to prevent deposition of metallic elements on the crucible outer surface. The chemical stability is also crucial factor to choose crucible material due to the strong reactivities of TRU and possible incorporation of Li metal during the operation. In this study, the chemical stabilities of four kinds of representative ceramic materials such as $Al_2O_3$, MgO, $Yl_2O_3$ and BeO were thermodynamically and experimentally evaluated at $500^{\circ}C$ with simulated LCC. The contact angle of LCC on ceramic materials was measured as function of time to predict chemical reactivity. $All_2O_3$ showed poorest chemical stability and the pores in BeO contributed to a decreases in contact angle. MgO and $Y_2O_3$ have superior chemical stability among the materials.

Microfabricated Disposable Microchip with a Capillary Electrophoresis and Integrated Amperometric Detection (모세관 전기영동 및 전기화학적 검출 시스템을 위한 일회용 마이크로칩)

  • Kim, Ju-Ho;Kang, C.J.;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2131-2133
    • /
    • 2004
  • 모세관 전기영동 및 전기화학적 검출 시스템을 마이크로 시스템에 적용하여 ITO 유리기판과 polydimethylsiloxane (PDMS)로 제작하였다. 제작된 모세관 전기영동 및 전기화학적 검출 시스템은 일회용으로 사용가능하며 전기화학적 검출에 아주 적합한 특성을 보인다. 모세관 전기영동 및 전기화학적 검출 시스템은 주입과 분리 채널 (80 ${\mu}m$${\sim}$ 40 ${\mu}m$ 깊이)을 가진 PDMS 층과 유리기판 위에 검출 전극으로 사용되는 ITO가 형성된 층으로 구성된다. PDMS 층과 ITO 유리 기판은 UV-$O_3$ cleaner를 사용하여 접합하였다. 완충용액은 10 mM 2-(N-morpholino)ethanesulfonic acid (MES)를 사용하였고 분석물질은 1 mM 농도의 dopamine과 1 mM 농도의 catechol을 사용하였다. 60 V/cm 전계로 주입 및 분리를 하였으며 작업전극과 기준전극 간의 전위는 +600 mV로 유지하며 분석물질의 농도에 비례하는 전류량법으로 측정하였다. 전기화학적 검출 회로는 천기영동 전계의 간섭으로부터 분리하였다. 10 mM MES 완충용액에서 바탕 전류의 크기가 ${\sim}$10 pA 일 때 측정전류 값은 10 nA이다. 측정된 피크 값은 기존의 Au 전극과 비교하여 선택성, 감도, 분해능이 유사한 특성을 보여준다.

  • PDF

Plasma Dealloying 공정을 통한 Nanoporous Thin Film 제작 및 특성분석

  • Lee, Geun-Hyeok;An, Se-Hun;Jang, Seong-U;Hwang, Se-Hun;Yun, Jeong-Hyeon;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.353.1-353.1
    • /
    • 2016
  • 다공성 물질은 동공의 크기에 따라 미세동공(Micropore), 메조동공(Mesopore), 거대동공(Macropore)으로 나누어 분류한다. 다공성 재료의 장점은 높은 비표면적으로써, 촉매, 센서, 연료전지 전극, 에너지 저장장치 등으로의 이용 가능성을 보여주는 연구가 활발히 보고되고 있다. 종래의 연구는 두 가지 이상의 원소로 구성된 박막을 제작한 후 전기화학적 분해법, 선택적 용해법 등 습식공정을 통해 다공성 구조체를 제작하였다. 하지만 본 연구에서는 Au, Ag 타겟과 $CH_4$ gas를 이용해 ICP-assisted reactive magnetron sputtering 장비를 활용하여 450 nm 두께의 Au-C, Ag-C 박막을 제작하였다. 이후 연속적으로 RF 250 W를 ICP antenna 에 인가하여 $O_2$ plasma dealloying 공정을 통해 탄소(Carbon) 만을 선택적으로 제거함으로써, 건식 공정만으로 Si wafer ($10{\times}10mm^2$) 기판 위에 250 ~ 300 nm 두께의 다공성 Au, Ag 박막을 제작하였다. SEM (Scanning Electron Microscopy)를 활용하여 표면, 단면 형상을 관찰해 다공성 구조를 확인하였으며, AES (Auger Electron Spectroscopy)를 통해 plasma dealloying 전 후 박막의 조성변화를 관찰하였다. 따라서 plasma dealloying 공정으로 제작된 다공성 Au, Ag 박막은 기존의 습식 공정 대비 청결하고 신속한 공정이 가능하며 높은 재현성을 통해 위의 적용분야에 보다 쉽게 사용될 수 있을 것으로 기대된다.

  • PDF

Antitumor metabolites of micro-organisms (미생물의 항종상성 대사산물)

  • 김병각
    • YAKHAK HOEJI
    • /
    • v.17 no.2
    • /
    • pp.71-91
    • /
    • 1973
  • 미생물의 대사산물은 극히 다양함으로 그중에는 암세포에 선택적으로 작용하여 증식을 억제하는 것이 있으리라는 예상하에서 종양을 이식한 동물을 사용하여 항암성 물질을 스크리-닝하기 시작한 것은 1951년경 부터였다. 그리하여 지난 20여년간에 200종 이상의 항종양성 물질이 보고되었고 그 화학구조는 가지 각색이다. 그간의 연구의 추세를 들이켜 본다면 초기에는 항종양작용에 중점을 두었기 때문에 독성이 강한 물질이 다소 보고되었으며 중기에는 조직배양을 이용했기 때문에 세포독 물질이 주축을 이루고 있다. 근래에는 독성이 낮은 물질, 특히, 고분자의 물질이 추구되고 있는 경향이다. 이미 보고된 200여종의 항종양성 항생물질중 실지로 쓰이고 있는 것은 10여종에 불과하다는 사실은 전신요법제로써의 항암제의 독어이 얼마나 중요한 가를 잘 증언해 주고 있다. 항종양성 항생물질은 화학구조, 생성하는 미생물, 작용기전 등에 분류할 수 있다. 그러나 화학구조가 다양하다는 점에서 또 생성하는 미생물은 대개 방성균류이라는 점에서 그리고 작용기전은 대개 핵산에 작용한다는 점에서 볼때 이러한 분류기준을 채택한다는 것이 특별히 유리한 점이 없는 것 같으므로 여기서는 편의상 발견된 연대순으로 나열하여 기재하기로 한다.

  • PDF

뇌의 수소 분광선 연구를 위한 다중 체적 화학적 이동 영상기법의 개발

  • Choe, Jeong-Hwan;Park, Seung-Hun;Kim, Si-Seung;Jeong, Seong-Taek;Lee, Yun
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.105-105
    • /
    • 2002
  • 목적: 수소 자기 공명 분광기법은 자기공명 영상으로는 얻을 수 없는 화학적 성분에 대한 정보를 제공하여 암을 포함한 여러 질환의 진단과 예측에 사용된다. 이 기법으로는 어떤 특정한 작은 체적을 선택하여 그 부위에만 자기공명 분광신호를 획득하는 단일 체적기법과 체적 전체를 위상변화를 주면서 여기시킨 후, 데이터 후처리 과정에서 체적별로 분리해내는 다중체적기법이 있다. 다중체적기법은 더 긴 영상 획득시간에도 불구하고 단일 체적기법에 비하여 분광상을 대조군과 비교할 수 있는 잇점이 있다. 뇌를 진단하는데 사용하기 위한 수소분광선을 얻기 위하여 다중체적 화학적 영상기법을 개발하여 모형과 자원자에 대하여 적용하여 그 유용성 확인하였다.

  • PDF

뇌의 수소 분광선 연구를 위한 다중 체적 화학적 이동 영상기법의 개발

  • Choi, Jung-Hwan;Park, Seung-Hoon;Kim, Si-Seung;Jung, Sung-Taek;Lee, Yoon
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.81-81
    • /
    • 2002
  • 목적: 수소 핵 자기 공명 분광기법은 자기공명 영상으로는 얻을 수 없는 화학적 성분에 대한 정보를 제공하여 암을 포함한 여러 질환의 진단과 예측에 사용된다. 이 기법으로는 어떤 특정한 작은 체적을 선택하여 그 부위에만 자기공명 분광신호를 획득하는 단일 체적기법과 체적 전체를 위상변화를 주면서 여기 시킨 후, 데이터 후처리 과정에서 체적별로 분리해내는 다중체적기법이 있다. 다중체적기법은 더 긴 영상 획득시간에도 불구하고 단일 체적기법에 비하여 분광상을 대조군과 비교할 수 있는 잇점이 있다. 뇌를 진단하는데 사용하기 위한 수소분광선을 얻기 위하여 다중체적 화학적 영상기법을 개발하여 모형과 자원자에 대하여 적용하여 그 유용성 확인하였다.

  • PDF