• Title/Summary/Keyword: 화학발광

Search Result 421, Processing Time 0.029 seconds

Characteristics of Chemiluminescence Intensities of Kerosene/Air Swirl Flames (케로신/공기 와류 화염의 화학발광 세기 특성에 관한 실험적 연구)

  • Lee, Hyeonjae;Seo, Seonghyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.485-496
    • /
    • 2015
  • The present study presents experimental results on the characteristics of emission spectra of kerosene/air swirl flames. The aviation fuel Jet A-1, which is used for the liquid rocket engines of the Korea Space Launch Vehicle, is used with three different swirlers to investigate the swirl strength effects. The emission spectra from the flames are measured with a spectrometer as the swirl strength and combustion air temperature are varied. Chemiluminescence intensities of $OH^*$, $CH^*$ and $C_2{^*}$ are identified from the spectra. The chemiluminescence intensities from the kerosene flames show sensitivity to the swirl strength and are affected by changes in the combustion air temperature. Among the three radicals of interest, $C_2{^*}$ show the most significant changes in chemiluminescence intensity with the swirl strength and equivalence ratio. The intensity ratios $I_{OH^*}/I_{CH^*}$ and $I_{C_2{^*}}/I_{CH^*}$ are adequate for indicating changes in the equivalence ratio with the air and fuel mass flow rates, respectively.

Effect of urea on blood-luminol chemiluminescence reaction (Urea가 혈액-luminol 화학발광에 미치는 영향)

  • Youngpyo Bae;Sungwook Hong
    • Analytical Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.332-339
    • /
    • 2023
  • This study aimed to verify the hypothesis that urea denatures hemoglobin in the blood, thereby exposing active sites of enzymes and enhancing the chemiluminescence of the blood-luminol reaction. When blood was pretreated with urea, higher concentrations of pretreatment urea or longer pretreatment times resulted in enhanced chemiluminescence in the blood-luminol reaction, supporting the above hypothesis. However, the chemiluminescence was enhanced when blood was treated with luminol mixed with an 8 M urea solution, although the fact that the time for urea to denature hemoglobin was shorter compared to when blood was pretreated with urea and followed by luminol. In addition, the chemiluminescence was enhanced when a transition metal without hemoglobin was reacted with urea-containing luminol. Based on these results, it is anticipated that urea not only denatures hemoglobin but also plays a role in the luminol-hydrogen peroxide reaction.

Electroluminescence Properties of Novel Blue-Emitting Materials Based on Spirobifluorene (Spirobifluorene 그룹을 포함하는 새로운 청색 발광 재료의 전계발광)

  • Sunwoo, Park;Hayoon, Lee;Hyukmin, Kwon;Godi, Mahendra;Sangshin, Park;Seungeun, Lee;Jongwook, Park
    • Applied Chemistry for Engineering
    • /
    • v.34 no.1
    • /
    • pp.94-97
    • /
    • 2023
  • 2,7-bis(3',6'-diphenyl-[1,1':2',1"-terphenyl]-4'-yl)-9,9'-spirobi[fluorene] (BTPSF) and 2,7-bis(1,4-diphenyltriphenylen-2-yl)-9,9'-spirobi[fluorene] (BDTSF) were successfully synthesized as novel blue-emission materials for organic light-emitting diodes (OLEDs) based on the spirobifluorene (SBF) moiety. BTPSF and BDTSF were obtained in high purity via a Diels-Alder reaction, without the use of a catalyst. Photoluminescence spectra of the synthesized materials showed maximum emitting wave-lengths of approximately 381 and 407 nm in solution and 395 and 434 nm in the film state, for BTPSF and BDTSF, respectively, indicating ultra-violet and deep blue emission colors. BDTSF was applied as an emissive layer (EML) in non-doped devices and achieved a current efficiency of 0.61 cd/A and an external quantum efficiency (EQE) of 0.46%.

Determination of Glucose in Whole Blood by Chemiluminescence Method (화학발광법에 의한 전혈 중의 당 정량)

  • Lee, Sang Hak;Choi, Sang Seob
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.3
    • /
    • pp.223-229
    • /
    • 2001
  • A method for the determination of glucose in human whole blood by chemiluminescence method using a stopped flow injection system has been studied. The method is based on the differences in the chemiluminescence intensities of luminol due to the different amounts of hydrogen peroxide produced from the glucose oxidase catalyzed reaction. The enzyme reactor was prepared by immobilization of glucose oxidase on aminopropyl glass beads and the chemiluminescence from a flow cell was measured by means of an optical fiber bundle. In order to obtain the optimum experimental conditions, effects of pH for the chemiluminogenic solution and enzyme reactor, flow rate and temperature on the chemiluminescence intensity were investigated. The calibration curve obtained under optimum experimental conditions was linear over the range from $1.0{\times}10^{-1}$ mM to 7.0 mM and the detection limit was $6.0{\times}10^{-2}$ mM. The proposed method was applied to the determination of glucose in whole human blood sample and the results were compared with those obtained by an official method. The present method was also evaluated by the results of recovery experiments.

  • PDF

Luminescent Properties of Four-Band White Light Emitting Diodes (사파장 백색 발광 다이오드의 발광 특성)

  • Young-Duk Huh;Su-Mi Lim
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.4
    • /
    • pp.370-375
    • /
    • 2003
  • $BaMg_2Al_16O_27:Eu,\SrGa_2S_4:Eu$, and ZnCdS:Ag,Cl phosphors were chosen to produce blue, green, and red emissions, respectively, under excitation from a violet light emitting diode (LED). A four-band white LED was obtained by a combination of nonabsorbed violet emission from a violet LED and blue, green, and red emissions from $BaMg_2Al_16O_27:Eu,\SrGa_2S_4:Eu$, and ZnCdS:Ag,Cl phosphors. The luminescent properties of the four-band white LED were also discussed.

Detection of luminol chemiluminescence using photodiode (화학 발광 검출을 위한 포토다이오드 제작)

  • Kim, Hyung-Il;Kang, Chul-Goo;Kang, Moon-Sik;Park, Jung-Ho;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1552-1554
    • /
    • 2002
  • 본 논문에서는 실리콘을 기초로 한 포토다이오드를 제작하여 현재 바이오센서에서 이용되고 있는 luminol 화학 발광을 전기적으로 검출하였다. 우선, 실리콘 웨이퍼에 이온주입을 통해 p-n 접합을 형성하고 Al 전극을 형성시켜 포토다이오드를 제작하였다. PDMS을 passivation 막으로 사용하여 horseradish peroxidase(HRP) 농도 변화에 따른 발광의 최적조건과 luminol, HRP가 섞인 용액에 서로 다른 양의 과산화수소를 넣어 발광이 최대로 발생하는 혼합비를 측정하였다. 최종적으로 2mM luminol, 25U HRP 조건 하에서 과산화수소 농도에 따른 화학 발광을 측정하였으며, $10{\mu}M$부터 $500{\mu}M$ 범위의 과산화수소 농도 변화에 따른 포토다이오드의 감도는 단위 면적당 23.429pA/ ${\mu}M$이다.

  • PDF

Study on the Interaction of U(VI) Species With Natural Organic Matters in KURT Groundwater (KURT 지하수의 천연 유기물질과 6가 우라늄 화학종의 상호작용에 관한 연구)

  • Jung, Euo Chang;Baik, Min Hoon;Cho, Hye-Ryun;Kim, Hee-Kyung;Cha, Wansik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.101-116
    • /
    • 2017
  • The interaction of U(VI) (hexavalent uranium) species with natural organic matter (NOM) in KURT (KAERI Underground Research Tunnel) groundwater is investigated using a laser spectroscopic technique. The luminescence spectra of the NOM are observed in the ultraviolet and blue wavelength regions by irradiating a laser beam at 266 nm in groundwater. The luminescence spectra of U(VI) species in groundwater containing uranium concentrations of $0.034-0.788mg{\cdot}L^{-1}$ are measured in the green-colored wavelength region. The luminescence characteristics (peak wavelengths and lifetime) of U(VI) in the groundwater agree well with those of $Ca_2UO_2(CO_3)_3(aq)$ in a standard solution prepared in a laboratory. The luminescence intensities of U(VI) in the groundwater are weaker than those of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution at the same uranium concentrations. The luminescence intensities of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution mixed with the groundwater are also weaker than those of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution at the same uranium concentrations. These results can be ascribed to calcium-U(VI)-carbonate species interacting with NOM and forming non-radiative U(VI) complexes in groundwater.

고효율 양자점 발광소자를 위한 양자점 나노구조체 제어

  • Im, Jae-Hun;Choe, Yeong-Ho
    • Information Display
    • /
    • v.20 no.1
    • /
    • pp.5-14
    • /
    • 2019
  • 양자점 발광소자 기술은 지난 20여년 동안 급격한 발전이 이루어졌으며, 이는 양자점 발광체 및 소자기술 전반에 대한 집중적인 연구의 결과로 생각할 수 있다. 그러나 양자점 발광소자기술의 상용화를 위해서 해결해야 할 문제는 소재(예: 무중금속 양자점 구현, 대량생산 등) 및 소자(예: 수명문제, 대면적 프린팅문제, 효율저하문제)에 걸쳐 산적해 있다. 본 기고문에서는 이상의 다양한 문제 중 양자점 발광소자의 효율저하문제를 집중적으로 다루었다. 비록 양자점 나노구조체의 제어 및 발광소자 연구가 여전히 카드뮴 기반 양자점을 바탕으로 한 기초연구영역에 머물러 있지만, 향후 친환경 양자점 합성기술이 본격적으로 발전하게 된다면 우수한 효율과 안정성을 보이는 양자점 발광소자가 구현되리라 기대된다.

Determination of Cr(Ⅲ) Iron by Chemiluminescence Method (화학발광법을 이용한 Cr(Ⅲ)이온의 정량)

  • Lee, Sang Hak;Ju, Ik Su
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.2
    • /
    • pp.145-150
    • /
    • 2002
  • A Method to determine Cr(III)ion in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of Cr(III) to a solution of lucigenin a nd hyrogen peroxide. The effects of pH, injection volumes of reagent and sample, and concentration of lucigenin and hyrogen peroxide on the chemiluminescence intensity have been investigated. The calibration curve for Cr(III) ion was linear over the range from 1.0${\times}$$10^{-6}$ to 1.0${\times}$$10^{-3}$M and the detection limit was 5.2${\times}$$10^{-8}$M under the optimal experimental condition of 437nm, 12.8,and 1.0${\times}$$10^{-6}$ and 2.0M for emission wavelength, pH, and concentration of lucigenin and hyrogen peroxide, respectively.