• Title/Summary/Keyword: 화재 크기

Search Result 326, Processing Time 0.028 seconds

A Study on Char Characteristics of Fire Retardant Treated Douglas Fir (난연처리된 Douglas Fir의 탄화특성에 관한 연구)

  • Park Hyung-Ju;Oh Kyu-Hyung;Kim Eung-Sik;Kim Hong
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.105-110
    • /
    • 2005
  • We tested the char characteristics of fire retardant treated Douglas fir at each of five constant external irradiance levels $(10,\;15,\;20,\;25\;및\;35kW/m^2)$. A Cone heater was used to expose the wood specimens to the heat flux. The size of specimens is 100- by 100- by 50-mm and the kinds of specimens are non-treated wood(N) and treated wood(F2 and f4) by water soluble fire retardants. The water-soluble fire retardants were made from mixture of aqueous solutions of monoammonium phosphate, sodium borate and zinc borate, and those are used for immersion of Douglas fir. In result of test, char fraction of fire retardant treated Douglas fir showed a considerably low char fraction than it of non-treated wood irrespective of increase of external heat flux. And char fractions has low levels with increase of fire retardant content. Burning rate of non-treated wood(N) was showed a relatively high burning rate than it of fire retardant treated wood(F2 and F4). And difference of burning rate shown more rapidly in high external irradiance than low external irradiance. When the external heat flux is $35kW/m^2$, average char rate of non-treated wood is rapidly about twice than fire retardant treated wood. Water-soluble fire retardants mixed in this study find out it has fire suppression and adiabatic effect by char layer from results of char fraction, burning rate, and char depth and rate.

An Experimental Study on The Fire Resistance Performance and Spalling of 100 MPa HSC Column Mixed Fiber-Cocktail (Fiber-Cocktail 섬유를 혼입한 100 MPa 고강도 콘크리트의 단면크기에 따른 폭렬 및 내화성능에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Yonl;Park, Kyung-Hoon;Yeo, In-Hwan;Kwon, Ki-Hyuck
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.85-92
    • /
    • 2011
  • Along the fire resisting capacity of high strength concrete has been brought up as a social issue, and the Ministry of Land also had notified the control standard about it, the researches for improving the fire resisting capacity have been considerably activated these days. In this study, we performed a research for developing a high strength concrete, contains the fiber cocktail, which is a hybrid of polypropylene fiber as organic matter, and steel fiber. As we analyzed the temperature of the steel part during the fire test with 100 MPa high strength concrete, there was a tendency that the lower temperature comes out with the larger cross section, and the $600{\times}600mm$, $800{\times}800mm$ cross sectioned can secure the fire resistance capability, so the $600{\times}600mm$ is deducted as the optimal size if we consider the double economic feasibility. As well, among them the best qualified $600{\times}600mm$ shapes, the fiber cocktail hybrid of $1.5kg/m^3$ PP fiber and $40kg/m^3$ of steel, comes out the best ratio.

The Deterioration Properties and Actual Conditions of Insulation Cover used at 22.9 kV Transformer Bushing (22.9 kV용 변압기 부싱 절연 커버의 실태 조사 및 열화 특성)

  • Choi, Chung-Seog;Kim, Hyang-Kon;Han, Woon-Ki;Lee, Ki-Yeon
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.35-41
    • /
    • 2006
  • In this study, we presented the problems in the insulation cover of 22.9kV transformer bushing through investigating actual conditions. After thermal stress applied to the insulation cover, deterioration patterns, thermogravimetric and infrared characteristics were analyzed, and the results were applied to the cause analysis of accidents and judgement of safety. The insulation covers are used to protect exposed terminals of transformer, but they had improper size and length. Therefore, they could not show efficient insulation function. In case that thermal stress of $150^{\circ}C$ was applied to the insulation covers, plastic insulation covers(A, B, D, E) damaged severely, whereas rubber insulation cover(C) showed normal shapes. In the result of thermogravimetric analysis, the thermal gravity of plastic covers(A) decreased about 33.3% at $307.8^{\circ}C\;to\;405.9^{\circ}C$. and he thermal gravity of rubber covers (C) decreased about 53.7% at $258.8^{\circ}C\;to\;32.9^{\circ}C$. In the result of FT-IR analysis, plastic covers showed peaks characteristic of $CH_2,\;CH_3$, C=O and C=C bonds, whereas rubber covers showed peaks characteristic of OH, $CH_2,\;CH_3$, C=O, C=N and C=C bonds.

Investigation and Improvement of the Comfort and Convenience of Domestic Ambulances (국내 구급차의 안락성 및 편의성 조사와 개선에 관한 연구)

  • Yoo, In-Sool;Shin, Dong-Min;Jeong, Jae-Han;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.119-126
    • /
    • 2017
  • This study examined the soundness, vibration, and size of ambulances currently used in Korea as well as the comfort and convenience of ambulancesin Korea. The target vehicles were measured and investigated using the currently used freight type, van type, and Benz ambulance. Currently, the ambulance standards in Korea have only formal production standards, and there is no regulation on safety for ambulances, space regulation for first aid, comfort, and convenience. Therefore, comparative experiments on the comfort and convenience were measured using noise and vibration measurement experiments, and research was conducted on the size and interior rearrangement of ambulances to investigate the areas that can improve the comfort and convenience. The noise measurementsshowed that the noise was large in the order of the van type, Benz type, and freight type. In the case of a speed of 40 km/h or more, the noise measurement result was 60 to 70 dB or more. In the case of vibration, the Benz type and van type ambulance were good, and the vibration of the freight type showed the worst result, highlighting the need for improvement. Lastly, it is not possible to increase the internal size of the structure of domestic ambulance. On the other hand, it is important that through ambulance relocation and the position of first aid personnel, it will be possible to use it more comfortably and conveniently.

A Study on the Heat Release Rate of EPS Sandwich Panel Core (EPS 샌드위치 패널 심재의 열방출율에 관한 연구)

  • Park, Hyung-Ju;Cho, Myung-Ho
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.72-78
    • /
    • 2008
  • The mass loss rate and heat release rate of EPS sandwich panel cores were analysed using variable external irradiation level. The experimental materials were exposed to incident heat fluxes form 20 to 50 kW/$m^2$. For the measurement of mass loss rate and heat release rate, the size of specimen was $100mm{\times}100mm{\times}50mm$ and the samples were 3 different kinds. The combustion heat were carried out from the Oxygen bomb calorimeter and the mass loss rate and heat release rate were carried out from the Mass loss calorimeter according to ISO 5660-1. As the results of this study, the mass loss rate of Type A, B, and C were 2.7 g/$m^2s$, 2.8 g/$m^2s$, and 2.3 g/$m^2s$ and the heat release rate of Type A, B, and C were 58.23 kW/$m^2$, 47.19 kW/$m^2$, and 50.06 kW/$m^2$ respectively at the heat flux of 50 kW/$m^2$. In conclusion, when the heat release characteristics applied to a classification system of Canada, Type A and C can be classified grade C-3, and Type C can be classified grade C-2 from all data of this study.

Suggestions for Safety Improvement of CNG Bus Based on Accident and Failure Analysis (CNG버스 사고원인 분석에 근거한 안전성 향상 방안에 대한 연구)

  • Yoon, Jae-Kun;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.69-76
    • /
    • 2008
  • Three failure cases of CNG composite vessels were reported since after January 2005. The 1st and 2nd accidents were indebted to vessel defect and installation mistake. The 3rd was caused by gas leak at pipe connections. In this paper various aspects were studied based on information of the three failure analysis, which must be improved for better safety of the CNG bus system. Overpressure region caused by vessel explosion was theoretically predicted and also assessed by PHAST program. Explosion of 120 l vessel under 20 MPa is equivalent to 1.2 kg TNT explosion. The predicted value by PHAST was more serious than theoretical one. However, actual consequence of explosion was much less than both of the predicted consequences. Since the CNG vessel was designed by the performance based design methodology, it is difficult to verify whether the required process and tests were properly conducted or not after production. If material toughness is not enough, the vessel should be weak in brittle fracture at early in the morning of winter season since the metal temperature can be lower than the transition temperature. If autofrettage pressure is not correct, fatigue failure due to tensile stress during repeated charging is possible. One positive aspect is that fire did not ocurred after vessel failure. This may be indebted to fast diffusion of natural gas which hindered starting fire.

  • PDF

Correlation Between Physical Features of 6th-Grade Elementary School Children and Chest Compression Depth (초등학교 6학년 학생의 체격과 흉부압박 깊이 간의 상관 관계 분석)

  • Uhm, Tai-Hwan; Park, Jeong-Hyun;Roh, Sang-Gyun;Moon, Tae-Young;Kim, Jee-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.493-499
    • /
    • 2009
  • 응급의료에 관한 법률에 따라 구조 및 응급처치에 관한 교육의 대상자로 일반시민인 구급차등의 운전자, 여객자동차운송사업용 자동차의 운전자, 보건교사, 경찰공무원 등에게 심폐소생술 교육을 실시하여 26,900명이 과정을 수료(한국, 2007)하였으나 초중고 학교 교과과정 중에는 체계적인 응급처치 교육이 없고 교육강사, 교육장비 등이 취약(한국, 2005)하여 교육체계의 확립이 필요한 실정이다. Kerschaver 등(1989)은 학생들을 대상으로 심폐소생술 훈련을 하는 것은 효과적이고 11살 부터 단순화한 내용으로 보다 쉽게 교육을 시작할 수 있을 것이라고 했으며 Lester 등 (1996)은 지식과 술기 능력 간에는 상관이 없으나 중학교 1학년 때가 적절한 훈련시기라고 했고 Urey 등(2003)은 의무과목으로 6-7살 초등학생을 위한 응급처치 프로그램, Lubrano 등(2005)은 8-11살 학생을 대상으로 하는 응급처치 교육 프로그램의 운영을 보고했다. 박 등(2006)은 초등학교 5-6학년 학생과 성인 간의 심폐소생술 교육 효과를 분석하여 학생군이 과정에 대한 이해는 우수했으나 술기에서는 적절한 흉부압박이 미흡했다는 결과를 제시하여 초등학생을 대상으로 하는 이론 교육이 효과가 있었으나 실습 교육은 체격에 제한을 받는다는 점을 시사했다. 체격은 물리적으로 측정, 확인할 수 있는 사람 몸의 상태로써 성별, 키, 몸무게 등의 전체적인 것과 각 부위의 크기, 모양, 비율 등의 부분적인 것으로 구분할 수 있으나 여기서는 키, 몸무게가 흉부압박에 영향을 끼쳤다고 볼 수 있다. 따라서 본 연구에서는 초등학교 6학년 학생을 대상으로 체격조건(키, 몸무게)과 성인 마네킨 흉부압박 깊이 간의 상관관계를 밝히고 회귀식을 도출하여 효과적인 심폐소생술이 가능한 대상을 제시하고자 한다.

  • PDF

Heat of Combustion Experiment Based on the Ratio of Moisture Content of Infected and Non-Infected Bursaphelenchus Xylophilus (재선충 감염 소나무와 비 감염 소나무의 수분함유율에 따른 연소열 실험)

  • Kwon, Hyuk;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.443-451
    • /
    • 2021
  • This study compared and analyzed the thermal characteristics based on the ratio of moisture content of infected and non-infected Bursaphelenchus Xylophilus by heat of combustion experiment. The experiment results are as follows. The analysisresult of the ratio of water content shows that 19.92% on average for infected Bursaphelenchus Xylophilus and 26.27% for non-infected which decreases water content as the size of conduction, convection, and radiant heat increases in case of fire. As the vaporization of the moisture content accelerates, the average moisture content is reached, and the result is contrary to the thermal characteristics of the wood that the moisture content is not ignited by a heat source when the moisture content is under 15%. The combustion heat analysis result showed that infected and non-infected Bursaphelenchus Xylophilus had no significant difference in combustion heat at about 3%. However, it shows that combustion heat is higher than other species. In conclusion, decreasing in moisture content based on the increasing conduction, convection, and radiant heat is one of the direct causes of ignition, and the lower the moisture content, the faster the fire spreads.

Development of Grinding/Polishing Process for Microstructure Observation of Copper melted Beads (구리 용융흔 미세조직 관측을 위한 연마/미세연마 프로세스 개발)

  • Park, Jin-Young;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.108-116
    • /
    • 2018
  • A melted bead microstructure can be divided into a deformed and undeformed layer. Measurement errors occur in the presence of a deformed layer, which should be removed through grinding/polishing whilst preserving the original structure. This paper proposes a grinding/polishing process to analyze the microstructure of copper melted beads. For the removal of the deformed layer, the correlation between the abrasive type/size, the polishing time and polishing rate was analyzed and the thickness of the deformed layer was less than $1{\mu}m$. The results suggest a new grinding/polishing procedure: silicon carbide abrasive $15{\mu}m$ (SiC P1200) 2 min, and $10{\mu}m$ (SiC P2400) 1 min; and diamond abrasive $6{\mu}m$ 8 min, $3{\mu}m$ 6 min, $1{\mu}m$ 10 min, and $0.25{\mu}m$ 8 min. In addition, a method of increasing the sharpness of the microstructure by chemical polishing with $0.04{\mu}m$ colloidal silica for 3 min at the final stage is also proposed. The overall grinding/polishing time is 38 min, which is shorter than that of the conventional procedure.

Characteristic Analysis of Wireless Channels to Construct Wireless Network Environment in Underground Utility Tunnels (지하공동구 내 무선 네트워크 환경구축을 위한 무선채널 특성 분석)

  • Byung-Jin Lee;Woo-Sug Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.3
    • /
    • pp.27-34
    • /
    • 2024
  • The direct and indirect damages caused by fires in underground utility tunnels have a great impact on society as a whole, so efforts are needed to prevent and manage them in advance. To this end, research is ongoing to prevent disasters such as fire flooding by applying digital twin technology to underground utility tunnels. A network is required to transmit the sensed signals from each sensor to the platform. In essence, it is necessary to analyze the application of wireless networks in the underground utility tunnel environments because the tunnel lacks the reception range of external wireless communication systems. Within the underground utility tunnels, electromagnetic interference caused by transmission and distribution cables, and diffuse reflection of signals from internal structures, obstacles, and metallic pipes such as water pipes can cause distortion or size reduction of wireless signals. To ensure real-time connectivity for remote surveillance and monitoring tasks through sensing, it is necessary to measure and analyze the wireless coverage in underground utility tunnels. Therefore, in order to build a wireless network environment in the underground utility tunnels. this study minimized the shaded area and measured the actual cavity environment so that there is no problem in connecting to the wireless environment inside the underground utility tunnels. We analyzed the data transmission rate, signal strength, and signal-to-noise ratio for each section of the terrain of the underground utility tunnels. The obtained results provide an appropriate wireless planning approach for installing wireless networks in underground utility tunnels.