• Title/Summary/Keyword: 화재 예방

Search Result 827, Processing Time 0.024 seconds

A Comparative Study on the Relationship among Posttraumatic Stress, Psychological Wellbeing, and Depression by SEM - Focusing on Policemen and Firefighters (구조방정식모형에 의한 외상후 스트레스와 심리적 복지감 및 우울 간의 관계 비교 고찰 - 경찰공무원과 소방공무원을 중심으로)

  • Bae, Jeom-Mo
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.109-117
    • /
    • 2012
  • The author analyzed and compared the relationship mechanism among measured variables effecting to posttraumatic stress and posttraumatic stress, psychological wellbeing, and depression in the case of 360 policemen and 360 firefighters working in Korean police stations and fire stations by the structural equation modeling. The results showed that firefighters' posttraumatic stress deteriorated psychological wellbeing and depression more than policemen's posttraumatic stress did. In conclusion, systematic prevention and management program for posttraumatic stress and mental health of public servants are needed.

Automatic Distress Notification System Working with an External VHF Device in Small Ship (비상재난 발생 시 외부 VHF 장비와 연동하는 소형선박용 재난자동속보장치)

  • Jeong, Heon
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • In this paper, I have developed an automatic distress notification system (ADNS) working with an external VHF device in small ship. The proposed system is as part of a small ship disaster analysis system which can detect and quickly respond to the small ship disaster. The automatic notification system receives the location information signal from the disaster analysis system, and the signal will be converted into voice signal to broadcast of the accident position through external VHF device. It will be sending a distress message as form of voice information through VHF device until sinking under the water. Through this research, I expect we'll be make a quick response and prevent a terrible loss of human life.

Measurement and Prediction of the Flash Point for the Flammable Binary Mixtures using Tag Open-Cup Apparatus (Tag식 개방계 장치를 이용한 가연성 이성분계 혼합물의 인화점 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sungjin;Song, Young-Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.181-185
    • /
    • 2005
  • The flash point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of industrial material. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The flash points for the n-butanol+n-propionic acid and n-propanol+n-propionic acid systems were measured by using Tag open-cup apparatus(ASTM D 1310-86). The experimental data were compared with the values calculated by the laws of Raoult and van Laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.

Electrostatic Prediction Embedded System based on PXA255 (PXA255 기반 정전기 예측 임베디드 시스템 개발)

  • Byeon, Chi-Nam;Kim, Kang-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.406-409
    • /
    • 2007
  • This paper proposes an algorithm that predicts current electrostatic charge in a factory. The algorithm based on LSM(Least Square Method) dynamically takes the number of sample while calculating the value of electrostatic charge. The simulation results show that the proposed algorithm gains 73.18161 standard deviation with 95% trust probability and is better than conventional algorithm. We design the electrostatic prediction embedded system based on pxa255 with the proposes algorithm.

  • PDF

Research about Recognition of Government Officials Regarding Korean Disaster Management System in Charge (한국 재난관리체계에 대한 담당공무원들의 인식에 관한 연구)

  • Lee, Jung-Il
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.10-25
    • /
    • 2010
  • As disaster potential power of modern society grows larger, to improve and reinforce efficiently a national system which prepares and responds disasters, analyzed the survey for government officials of the department disaster management. Following is the contents of this research. First, cooperative relationship to disaster management organizations. Second, necessity of law establishment related crisis and disaster department. Third, by recognition regarding disaster management situational variable, overall recognition regarding disaster management situation, overall recognition regarding crisis type, recognition regarding occurrence possibility along disaster scale. Fourth, by recognition regarding structural variable of disaster management, the National Emergency Management Agency regarding disaster management, related organization, recognition difference of local government. It is a research about confusion regarding step of prevention - preparation - correspondence - restoration.

Research about Members' Recognition of Crisis Management System to Preparation Phase of Terror Countermove - Focusing on the Fire Fighting Public Service Personnel - (테러대응 준비단계의 위기관리체제 구성원의 인식에 관한 연구 - 소방지방공무원을 중심으로 -)

  • Oh, Tae-Kon
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.24-29
    • /
    • 2007
  • This research is accomplished for the purpose of providing fundamental materials to improve the level of prevention consciousness by deducting awareness difference through analyzing awareness level about terror preparation of members of crisis management system - the public service personnel in charge of crisis management in a self-governing body and the fire fighting public service personnel. For this research, That is measured through the priority order survey about a specialty of public service personnel in charge of crisis management and a level of crisis prepartion and a cooperation between crisis management system and etc. As a result of analysis, it is revealed that there is a difference about the priority order of measurement variable to terror preparation but all the members are recognizing the importance of that.

A Case of Resuscitation of an Electrocuted Child by a 119 Paramedic (감전으로 심정지된 소아환자 소생 1례)

  • Lee, Jae-Min;Kim, Dae-Won;Yun, Hyeong-Wan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.135-140
    • /
    • 2020
  • The purpose of this study was to prevent electric shock to children. children are at high risk of electrocution by accidents. In the present case, a 2-year-old child was electrocuted after inserting metal chopsticks into a home outlet. In this case, professional advanced cardiac life support (ACLS) was properly performed by a 119 paramedic, resulting in the return of spontaneous circulation (ROSC) in the child. There are very few successful cases of resuscitation of patients involved in electric shock accidents in Korea, and we report a case of ROSC and discharge and proper resuscitation by a 119 paramedic.

Study on the Combustion Characteristics of Flammable materials and Combustion Accelerants in an Arson (방화 범죄에서 가연성 물질과 연소촉진제의 연소 특성에 관한 연구)

  • Park, Hye-Jeong;Nam, Ki-Hun;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.7-11
    • /
    • 2017
  • The purpose of this study is to recognize the necessity for the management of the available materials in cases of arsons and to prevent arson gaining an understanding of the combustion characteristics of the flammable materials and combustion accelerants in arson cases. We investigated and analyzed the statistical data on arsons and selected flammable materials (wood, paper, synthetic textiles, synthetic resins), and combustion accelerants (gasoline, diesel, solvent) that are frequently used in cases of arson. We conducted a thermogravimetric analysis to assess the thermal properties of the flammable materials. Also, we conducted burning and flame spread rate tests for the purpose of comparing and analyzing the combustion characteristics of the flammable materials and combustion accelerants.

Simulation of Detailed Wind Flow over a Locally Heated Mountain Area Using a Computational Fluid Dynamics Model, CFD_NIMR_SNU - a fire case at Mt. Hwawang - (계산유체역학모형 CFD_NIMR_SNU를 이용한 국지적으로 가열된 산악지역의 상세 바람 흐름 모사 - 화왕산 산불 사례 -)

  • Koo, Hae-Jung;Choi, Young-Jean;Kim, Kyu-Rang;Byon, Jae-Young
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.192-205
    • /
    • 2009
  • The unexpected wind over the Mt. Hwawang on 9 February 2009 was deadly when many spectators were watching a traditional event to burn dried grasses and the fire went out of control due to the wind. We analyzed the fatal wind based on wind flow simulations over a digitized complex terrain of the mountain with a localized heating area using a three dimensional computational fluid dynamics model, CFD_NIMR_SNU (Computational Fluid Dynamics_National Institute of Meteorological Research_Seoul National University). Three levels of fire intensity were simulated: no fire, $300^{\circ}C$ and $600^{\circ}C$ of surface temperature at the site on fire. The surface heat accelerated vertical wind speed by as much as $0.7\;m\;s^{-1}$ (for $300^{\circ}C$) and $1.1\;m\;s^{-1}$ (for $600^{\circ}C$) at the center of the fire. Turbulent kinetic energy was increased by the heat itself and by the increased mechanical force, which in turn was generated by the thermal convection. The heating together with the complex terrain and strong boundary wind induced the unexpected high wind conditions with turbulence at the mountain. The CFD_NIMR_SNU model provided valuable analysis data to understand the consequences of the fatal mountain fire. It is suggested that the place of fire was calm at the time of the fire setting due to the elevated terrain of the windward side. The suppression of wind was easily reversed when there was fire, which caused updraft of hot air by the fire and the strong boundary wind. The strong boundary wind in conjunction with the fire event caused the strong turbulence, resulting in many fire casualties. The model can be utilized in turbulence forecasting over a small area due to surface fire in conjunction with a mesoscale weather model to help fire prevention at the field.

The Measurement of Autoignition Temperature for n-Propanol and Formic acid System (n-Propanol과 Formic acid계의 자연발화온도 측정)

  • Park, Sang-Hun;An, Jong-Il;Kim, Se-Ho;Park, Yoon-A;Choi, Jin-Young;Han, Jin-Seok;Oh, Su-Yong;Jang, Seon-Yeon;Ha, Dong-Myeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.164-164
    • /
    • 2013
  • 화학 관련 산업은 고온, 고압뿐만 아니라 반응성이 큰 물질들을 사용하는 복잡한 공정으로 이에 맞는 안전기술이 요구된다. 산업 현장에서 취급하고 있는 각종 화학물질의 안전관리를 어렵게 하는 이유는 취급하는 물질의 화재 및 폭발 특성치에 관한 자료가 부족하거나 정확하지 않은 연소 특성치를 사용하기 때문이다. 가연성물질의 연소현상 가운데 하나인 자연발화는 가연성 혼합기체에 열 등의 형태로 에너지가 주어졌을 때 스스로 타기 시작하는 산화현상으로, 주위로부터 충분한 에너지를 받아서 스스로 점화할 수 있는 최저온도를 최소자연발화온도(AIT : Auto ignition Temperature)라고 한다. 최소자연발화온도는 가연성 액체의 안전한 취급을 위해 중요한 지표가 된다. 순수물질의 최소자연발화온도를 문헌들에서 비교하면, 동일 물질인데도 불구하고 문헌에 따라 다른 최소자연발화온도가 제시되고 있다. 따라서 사업장에서 사고를 예방하기 위해서는 정확한 연소 특성 자료를 이용해야 해야 한다. 그러나 문헌에 제시된 대부분의 자료들은 과거 표준장치 및 자체 제작된 장치 등을 사용해서 얻은 결과이므로, 최근에 고안된 표준 장치를 이용한 결과가 매우 유용한 자료가 될 것으로 본다. 본 연구에서는 자연발화온도를 측정하는데 있어서 최근에 고안된 표준장치인 ASTM E659장치를 이용하여 n-Propanol과 Formic acid 혼합물의 최소자연발화 온도를 측정하였다. n-Propanol과 Formic acid 혼합물의 최소자연발화 온도는 화학 관련 산업 공정에서 매우 중요한 자료가 될 것이다.

  • PDF