• 제목/요약/키워드: 화재 사고

검색결과 1,170건 처리시간 0.031초

A Study on risk management measurers about High-rise APT (고층아파트 위험관리 방안)

  • Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • 제9권2호
    • /
    • pp.178-187
    • /
    • 2013
  • This paper studied the potential risk of high-rise apartment by analysis of the loss ratio of housing fire insurance, statistics related high-rise apartment fire, and the insured amount of housing fire insurance, and, found that it is so high and need the improvement of risk management measures for high-rise apartment. Accordingly, the study recommend the composit risk management measures including preventing of fire expanding for higher stories, a shelter for people of hire-rise apartment, and sprinkler protection, etc. Also as risk transfer measures, the composit risk measures for high-rise apartment includes the full insurance of housing fire insurance, third party property liability insurance, and development of endorsement for special risk such as a typhoon, liability etc.

Analysis of Passenger Refuge Model Using EXODUS Refuge Simulator: Case of the Daegu Underground Station Fire (EXODUS 피난시물레이터를 이용한 대구지하역사화재 승객피난모델분석)

  • Lee, Chang-Hyun;Jang, Yong-Jun;Park, Won-Hee;Kim, Dong-Hyeon
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1807-1813
    • /
    • 2007
  • The study aims at analyzing an underground station refuge model using EXODUS, one of the refuge simulation programs. The model for simulation is the Daegu Subway (Joongang-ro station). The details of the accident are referred to as the simulation condition the refuge time of traveling from the $3^{rd}$ basement platform to the $1^{st}$ basement is mainly calculated, with passengers numbering 1,000 including 329 at car 1079, 320 at car 1080, and 360 who are not on board. Reference data is used to set up the position of passengers. CFAST fire simulator is also used, and a fast curve among the $t^2$ growth curves, selected as fire growth scenario. The zone is divided into a total of 24 including 18 at the $3^{rd}$ basement platform and 6 at the $2^{nd}$ basement the $1^{st}$ basement is excluded in the fire simulation, however.

  • PDF

Fire and explosion risk of metal particles with the same mean diameter (동일 입경 조건에서의 금속분진의 화재.폭발위험성)

  • Han, Ou-Sup;Lee, Keun-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.376-377
    • /
    • 2011
  • 최근 Mg, Mg-Al합금, Al은 전자제품의 케이스, 차량의 휠 등의 신소재로서 활용성이 높아 사회적 수요가 급격히 늘고 있다. 이러한 수요 증가와 함께 관련 사업장에서는 취급 과정에서 폭발사고 위험성이 높아지고 있는데, 2010년도에는 국내 사업장에서 금속 분진에 의한 폭발사고가 4건이 발생하여 인명 및 재산피해가 발생하였다. Mg-Al합금의 폭발사고로 사망 1명과 부상 2명이 발생하였으며, Al분진의 폭발사고는 3건이 발생하여 사망 2명과 부상 3명의 인명피해로 이어졌다. 사고조사를 통하여 사업장에서의 금속분진에 대한 위험인식이 매우 낮은 것이 유사 사고가 반복되고 있는 가장 큰 이유로 알려지고 있는데, 이는 금속분진에 대한 부족한 안전기술정보와 밀접한 관련이 있다. 본 연구에서는 Mg, Mg-Al합금, Al등을 취급하는 관련 사업장에서 폭발사고 예방대책을 위하여 활용할 수 있는 폭발특성에 관한 안전기술정보 제공을 목적으로 하고 있다. 보다 구체적으로는 사고 다발 금속분진에 대한 위험성 이해에 도움을 될 수 있도록 동일 입경분포 조건에서의 위험성을 정량적으로 평가하였으며, 이를 위하여 각 금속분진의 동일 입경 조건에서 최대폭발압력, 폭발하한계 등의 폭발위험성 데이터를 실험적으로 조사 하였다. 조사한 시료는 평균입경 200 mesh의 Al, Mg, Mg-Al(60:40 wt%)로서 입도분석기(Beckman Coulter LSI 3320)를 사용하여 측정한 결과 평균입경은 약 $155{\mu}m$로 나타났다. Al분진의 농도변화에 따른 폭발압력을 조사한 결과, 최대폭발압력(Pmax)은 7.9 bar였으며 최대폭발압력상승속도 (dt/dP)max는 농도 $1500[g/m^3]$에서 322 [bar/s]로 최대가 되었으며 폭발 하한계(LEL)는 $70[g/m^3]$가 얻어졌다. 반면에 순수한 Mg의 LEL은 $30[g/m^3]$였으며 Pmax는 6.4 bar, (dP/dt)max는 100 [bar/s]가 얻어졌다. 이러한 결과로부터 LEL이 낮은 Mg는 Al보다 연소성이 큰 것으로 나타났으며, Al은 화염을 유지하는데 필요한 최저 열분해 가스농도를 확보하는데 Mg보다도 고농도의 분진이 필요함을 알 수 있었다. 또한 Mg-Al(60:40 wt%)의 LEL은 $50g/m^3$이었으며 Pmax는 9.4 bar, (dP/dt)max는 472 [bar/s]가 얻어졌다. 이러한 결과로부터 Mg-Al(60:40 wt%)합금의 연소성을 살펴보면 착화하기 쉬운 정도는 Mg와 Al의 성분비에 의해 변화하지만 Mg와 Al의 중간 정도로 나타나는 반면, Pmax는 Mg 또는 Al의 단독 물질 성분보다도 매우 큰 것을 알 수 있었다. 본 연구를 통하여 단일 성분의 Mg와 Al보다도 Mg와 Al이 일정 비율로 구성된 Mg-Al합금의 경우가 화재폭발 위험성이 증가한다는 사실을 알 수 있었으며, 이와 같은 폭발위험특성 자료를 활용하여 분진의 보관, 취급, 폐기 등의 지속적 관리가 필요하며 사업장 특성에 적합한 안전대책을 통한 사고예방대책이 요구된다.

  • PDF

VTS 관제구역 해양사고 분석

  • Yu, Sang-Rok;Kim, Ji-Gwan;Jeong, Jae-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 한국항해항만학회 2012년도 춘계학술대회
    • /
    • pp.568-570
    • /
    • 2012
  • 해양사고는 충돌, 좌초, 접촉, 화재, 폭발, 침몰, 전복, 인명사상, 손상 등으로 분류할 수 있다. 이 중 관제사와 관련있는 것은 충돌사고다. VTS 관제구역내 최근 10년간 발생한 충돌사고를 재결서를 통해 분석하였다. 충돌사고 분석으로 각 VTS별 관제 주안점을 정리하여, 신임관제사 및 전입자에게 OJT 교육자료로 활용하고자 한다.

  • PDF

Electrical Fire Disaster Prevention Device of Double Protection using a High Precision Current Sensor in Low Voltage Distribution System (고정밀 전류센서를 이용한 저압배전계통 이중 보호용 전기화재 방재장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • 제23권3호
    • /
    • pp.40-47
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is confirmed the unreliability of the existing RCD by electrical fault simulator and is proposed a Electrical Fire Disaster Prevention Device (EFDPD) by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the EFDPD has double protection function which operates self circuit breaker or rapidly cuts off the existing RCD. The proposed EFDPD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

A Study on Accident Prediction Models for Chemical Accidents Using the Logistic Regression Analysis Model (로지스틱회귀분석 모델을 활용한 화학사고 사상사고 예측모형 개발 연구)

  • Lee, Tae-Hyung;Park, Choon-Hwa;Park, Hyo-Hyeon;Kwak, Dae-Hoon
    • Fire Science and Engineering
    • /
    • 제33권6호
    • /
    • pp.72-79
    • /
    • 2019
  • Through this study, we developed a model for predicting chemical accidents lead to casualties. The model was derived from the logistic regression analysis model and applied to the variables affecting the accident. The accident data used in the model was analyzed by studying the statistics of past chemical accidents, and applying independent variables that were statistically significant through data analysis, such as the type of accident, cause, place of occurrence, status of casualties, and type of chemical accident that caused the casualties. A significance of p < 0.05 was applied. The model developed in this study is meaningful for the prevention of casualties caused by chemical accidents and the establishment of safety systems in the workplace. The analysis using the model found that the most influential factor in the occurrence of casualty in accidents was chemical explosions. Therefore, there is an urgent need to prepare countermeasures to prevent chemical accidents, specifically explosions, from occurring in the workplace.

Study of the Improvement of Hazardous Chemical Management for Chemical Accident Prevention (화학사고 예방을 위한 유해화학물질 관리 개선 연구)

  • Lee, Deok-Jae;Lee, Tae-Hyung;Shin, Chang-Hyun
    • Fire Science and Engineering
    • /
    • 제31권1호
    • /
    • pp.74-80
    • /
    • 2017
  • Chemicals are convenient for humans but the damage caused by hazardous chemicals can be widespread if they are not managed properly. The Chemical Substance Management Act strengthened the management of hazardous chemicals and the management of handling facilities. On the other hand, an analysis of chemical accidents occurring in the past 4 years showed that chemical accidents occurring at the handling facilities are increasing, and additional preventive measures are needed. In this study, to prevent chemical accidents of hazardous chemicals, the causes and problems of accidents were analyzed through the case study of chemical accidents and measures for improvement are proposed.

The ubiquitous information technology based tunnel safety monitoring system (uIT 기반의 터널 안전관리 모니터링시스템 구축)

  • Kim, Do-Hyoung
    • 한국IT서비스학회:학술대회논문집
    • /
    • 한국IT서비스학회 2007년도 추계학술대회
    • /
    • pp.260-265
    • /
    • 2007
  • 제2만덕터널은 부산시민의 생활에 반드시 필수적인 장소로 하루 10만대의 차량이 이용하는 곳이지만 터널의 노후화와 안전시설의 미비로 사고발생시 인명피해는 물론 경제적 손실 발생 가능성이 큰 터널 시설물이다. 제2만덕터널은 2005년 7윌부터 2006년 9월까지 교통사고 56건, 고장사고 44건, 화재 2건, 기타 11건의 사고가 발생한 곳으로 관리사무소 전담요원 7명이 3교대로 근무하고 있으며 CCTV 15대만으로 사고를 대비하고 있다. 터널의 중요성을 고려할 때 노후화된 터널이지만 유비쿼터스 기술 및 구조물 계측기술을 적용한 안전관리 시스템이 필요하다. 제2만덕터널은 1985년에 준공되어 현재와 같은 보다 체계적인 터널 안전 관리 기술이 적용되리 많은 터널로 USN기반 구조물, 노면, 화재, 공기, 조명센서를 이용한 실시간 모니터링과 돌발적인 교통사고 발생 시에 신속한 복구 처리를 위하여 유관기관과 연계된 긴급 지원 시스템의 구축의 좋은 모델이 될 것이다. 부산광역시에는 총 17개 터널이 있으며 그 중 11곳이 90년 이전에 구축된 것으로 본사업으로 노후화 터널의 유비쿼터스 기반의 안전관리 시스템이 개발된다면 부산을 중심으로 전국에 산재한 노후화 터널의 안전 관리 개선에 미치는 파급효과가 클 것이며 유비쿼터스 기술의 대표적 적용 사례가 될 것이다.

  • PDF

The Study of Fire Behavior Data Base for Fire Spread Prevention (건축물 화재확대방지를 위한 화재특성 DB 구축 연구)

  • Yoo, Yong Ho;Kweon, Oh Sang;Kim, Heung Youl;Kim, Jung Hyun;Jang, Seung Bae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 한국화재소방학회 2013년도 춘계학술대회 초록집
    • /
    • pp.167-168
    • /
    • 2013
  • 국내 화재사고는 2012년도에만 43,247건에 이르며 큰 사회적 비용을 소비하고 있는 위험 요인으로 인식되고 있다. 본 연구에서는 화재 수치해석의 입력자료 획득을 위한 화재 실험을 수행하였으며, 이러한 실규모 화재실험을 통하여 얻은 결과를 데이터 베이스화 하였다. 이는 국내 성능적 화재안전 설계를 위한 기본적인 자료를 제공함과 동시에 화재분야 수치해석의 신뢰성을 높이는데 크게 기여할 수 있을 것이다.

  • PDF

A Case Study on Determination of Fire Causes for SAUNA FACILITY Fires Validate by CFD Fire & Smoke Simulation Modeling Method (화재시뮬레이션 S/W를 이용한 연소예측모델링기법에 의한 국내 사우나 시설의 화재원인규명을 위한 사례연구)

  • 박형주;신동철
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 한국화재소방학회 2002년도 추계학술대회논문집
    • /
    • pp.358-374
    • /
    • 2002
  • 최근 빈번하게 발생하고 있는 사우나 등의 열을 방사하는 도크내에서 발생하는 화재사고는 다중이용업소를 이용하는 불특정한 사람들의 생명을 위협하고 있는 수준에 도달하고 있다. 특히 이런 시설의 화재는 화재발생 후에 소방대에 의한 진압에만 치중하고 있어 향후 계속하여 화재가 발생할 우려가 큼에도 불구하고 착화원인을 규명하는데 소홀히 하고있다. 특히 현장감식에 의한 육안조사만을 실시하여 화재원인을 추정하거나 설정하는 경우가 대부분이라 근본적인 대책을 세우지 못하고 있다. 따라서 본 연구에서는 육안조사 등에 의하여 설정한 착화원인을 과학적인 분석법 즉, EU국가에서 널리 사용하는 CFD(컴퓨터수치해석)시뮬레이션 S/W를 사용하여 연소모델링에 의한 검증조사기법을 적용하여 원인을 검증하는데 사용하여 국내화재조사기술의 과학화를 시도하였다.

  • PDF