• Title/Summary/Keyword: 화재 사고

Search Result 1,170, Processing Time 0.027 seconds

Development of 119 Integrated Emergency Management System Training Simulator System (119 긴급구조시스템 교육훈련 시뮬레이터 개발)

  • Chung, Byung-Ho;Shin, Jae-Hong;Cho, Ung-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.461-467
    • /
    • 2015
  • 119 Integrated Emergency Management System, 119 IEMS hereinafter, is specialized command and control system for fire H.Q., that supports effective response activity at Fire, Rescue, and First Aids; it covers the emergency call taking, dispatch command delivery and situation control after dispatch command. While the efficiency of emergency response activity of call-taker and dispatcher is directly linked to the capability of qualified response in protecting the life and properties at real-time emergency condition, there is not any similar simulator system that can be used for training purposes for newly allocated personnel or beginner of emergency call taking and dispatch activity - 119 IEMS in fire H.Q. is the operation system that cannot be shared with other purposes, and they're highly expensive ICT system and infrastructure to be used as training and education. 119 Integrated Emergency Management Simulator System, 119 IEMS Simulator, was developed to be utilized in low cost for the training of 119 emergency call taker and dispatcher, and it can be used in training of various types of disaster and emergency handling, spans to emergency call taking, dispatch command, and field report and situation control after dispatch command.

A Study on Analysis of Requirements in the Smart Societal Security Wireless Network (스마트 사회안전무선통신망 요구사항 분석에 관한 연구)

  • Choi, Jae-Myeong;Woo, Byung-Hoon;Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.518-523
    • /
    • 2014
  • The development of Societal and Scientific technologies have increased risk of dysfunction caused by new technologies such as nuclear power, information technology. Also, urbanization and population density is increasing risk to high-rise building fires, traffic accidents, crime and etc. Implementation of wireless communication network on the societal security is very necessary for prevention, preparation and response against these risks. It always consists maintenance, management and the network must be maintained in an emergency. In this paper, we studied the societal security wireless communication network for prevention, preparation and response against complex disasters, and analyzed requirements(essential function, add-ons) for implementation network in the societal security wireless network.

Incident shock and Related Factors in Rescue Workers (구조대원의 사건충격 정도와 관련 요인 분석)

  • Yoo, Eui-Tae;Cho, Sung-Je
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2225-2233
    • /
    • 2013
  • This study was designed to identify the extent of incident shock who are in high risk of post traumatic shock stress, and analyze the related factors that affect the extent of incident shock. The subjects are 415 rescue workers from Seoul Metropolitan Fire & Disaster Headquarters, who are in high frequency of fire outbreaks and rescue mobilization. With a reliability of Cronbach's ${\alpha}$=.975, the results show invasion, avoidance, sleep disorder and emotional paralysis, dissociative symptom, hyper arousal as foremost causes respectively. Moreover, the results imply that the extent of incident shock was higher in people with more age or being married. Also, from the occupational perspective, the number of years as fire fighters, as rescue workers, mobilization and experiences at work in proportion to incident shocks has risen exponentially. It is notable that the groups who alleviate stress by consuming liquors had higher extent of incident shock. In conclusion, to deal with groups in high risk, management system and prevention care programs for incident shocks need to be introduced immediately and put into effect.

A Study on the Explosion Characteristics of by Product Gas of Carbon Black Manufacturing Process (카본블랙 제조 부생가스의 폭발 특성연구)

  • Oh Kyu-Hyung;Lee Sung-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.60-64
    • /
    • 2006
  • Explosion range and explosion characteristics of by product gas from carbon black manufacturing process were studied. About 75% of the by product gas were composed with water vapour and nitrogen. And the combustible component in the gas were hydrogen, methane, acetylene and carbon mono-oxide. Because of the combustible components in the by product gas there are explosion hazards in the gas handling process. Explosion range of the gas by experiment was from 17.1% to 70.7% and the value has considerable difference with the calculated value from Lechatelier law. Explosion pressure of the gas was $5.4kg/cm^2$ and the average explosion pressure rise rate was $39.2kg/cm^2/s$. Based on the experimental result we can expect that a explosion or fire accident during the handling the gas can make a severe loss, therefore there should be a explosion prevention or protection measures in the gas handling process.

  • PDF

A Study on Facility Criteria of Small Petrol Stations based on Quantitative Risk Assessment (정량적 위험성 평가에 기반한 간이 주유취급소 시설기준에 대한 연구)

  • Park, Wooin;Ku, Jae-Hyun;Song, Yong-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.44-52
    • /
    • 2014
  • Small petrol stations have great potential for a wide distribution in metropolitan area in which the land value possesses primary installation cost of the facility. The objective of the present study is to propose appropriate facility regulations of small petrol stations in Korea that can be popularly installed in the future in terms of securing safety in addition to serviceability. The hazard analysis and damage prediction from the possible fire and explosion accidents were performed using a software, PHAST v.6.5. As essential components of the facility regulations proposed in this study, the regulations about the refueling lot, maximum capacity of underground tank, location of fixed refueling facilities, height of firewall for small petrol stations were subsequently compared with those for regular-sized petrol stations.

A Study on Semi Quantitative Risk Analysis for Air Separation Unit using a GRA(Generic Risk Analysis) Method (GRA(Generic Risk Analysis) 기법을 이용한 공기분리시설에 대한 준 정량적 위험성 평가에 관한 연구)

  • Shin, Jung-Soo;Byun, Hun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.1
    • /
    • pp.56-66
    • /
    • 2013
  • The gas production plants supply the inert gas to production plants for maintaining safe operation and also supply combustible, flammable, explosive and toxic gases as functions of basic materials needed for producing chemical goods. In addition, gas plants need to be safe and reliable operation because they are operated under high temperature, high pressure, cryogenic and catalytic reactions. As these plants have a complex process in operation, there has been a risk that major industrial accidents such as a fire, explosion and toxic gas released, also risks of asphyxiations by inert gases and burns caused by high temperature and cryogenic substances. This study is to carry out the semi quantitative risk assesment method which is the generic risk analysis (GRA). This method is applied to air separation unit(ASU) to identify its initial risk, safety barriers, residual risk and elements important for safety(EIS). The result of this study, suggested the management tools and procedures of implementation for EIS management.

A Study on the Damage of Flame caused by the Vapor Cloud Explosion in LPG Filling Station (LPG충전소에서 증기운폭발에 의한 화염의 피해에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.53-60
    • /
    • 2010
  • LPG(Liquefied Petroleum Gas) vehicles in metropolitan area are being applied to improve air quality and have been proven effective for the reduction of air pollutant. In addition, LPG demand is growing rapidly as an environmentally friendly energy source and its gas station is also increasing every year. Consequently, this study tries to find out the influence of flame caused by the VCE(Vapor Cloud Explosion) in filling station on the adjacent combustibles and people by simulating relevant quantity of TNT. In addition, the damage estimation was conducted by using API regulations. If the scale of the radiation heat is known by calculating the distance of flame influence from the explosion site, the damage from the site can be easily estimated. And the accident damage was estimated by applying the influence on the adjacent structures and people into the PROBIT model. According to the probit analyze, the spot which is 30m away from the flame has 100% of the damage probability by the first-degree burn, 99.2% of the damage probability by the second-degree burn and 93.4% of the death probability by the fire.

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

Explosion Characteristics and Flame Velocity of Suspended Plastic Powders (플라스틱 부유 분진의 폭발특성과 화염전파속도)

  • Han, Ou Sup;Lee, Keun Won
    • Korean Chemical Engineering Research
    • /
    • v.54 no.3
    • /
    • pp.367-373
    • /
    • 2016
  • Many of plastic powders handled in industry are combustible and have the hazard of dust fire and explosion accidents. However poor information about the safe handling has been presented in the production works. The aim of this research is investigated experimentally on explosive characteristics of various plastic powders used in industry and to provide additional data with safety informations. The explosibility parameters investigated using standard dust explosibility test equipment of Siwek 20-L explosion chamber. As the results, the dust explosion index ($K_{st}$) of ABS ($209.8{\mu}m$), PE ($81.8{\mu}m$), PBT ($21.3{\mu}m$), MBS ($26.7{\mu}m$) and PMMA ($14.3{\mu}m$) are 62.4, 59.4, 70.3, 303 and 203.6[$bar{\cdot}m/s$], respectively. And flame propagation velocity during plastic dust explosions for prediction of explosive damage was estimated using a flame propagation model based on the time to peak pressure and flame arrival time in dust explosion pressure assuming the constant burning velocity.

The grid-connected bidirectional PCS technology of the ESS (에너지 저장장치의 계통 연계형 양방향 PCS 기술)

  • Ko, Bong-Woon
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1280-1287
    • /
    • 2019
  • Grid-connected bidirectional PCS(Power Conditioning System) technology is a technology for implementing distributed renewable energy smart grid. And it is always charged by using power collected from solar modules and commercial grid power among vast smart grid systems, and stored when needed.It is a hybrid energy storage device that allows power to be released into the low voltage system. To this end, a PV input power converter with MPPT function, a bidirectional power converter for battery charging and discharging, and a DC Link input are output to a 3 phase 380V AC system, and if nessary, the bidirectional DC/DC converter We designed and developed a PCS with three power converter structures composed of inverters that perform battery charging. Currently, this system is applied to the site of Jeju, which is vulnerable to power outages and fire accidents.