• Title/Summary/Keyword: 화재탈출

Search Result 60, Processing Time 0.033 seconds

Plans to Improve Safety Experience Education through the Experimental Analysis of Evacuation Equipment (피난기구 사용시간 실험분석을 통한 안전체험교육 개선방안)

  • Lee, Jeong Il;Lee, Sung Eun
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.35-42
    • /
    • 2019
  • The aim of this study is to investigate the direction of improvement of safety experience education through the analysis of the evacuation time experiment. For the study, test subjects were divided into groups of similar body size and weight. The test subjects were directly experienced four evacuation devices, and the experience time was measured. As a result of the analysis of the total time from the installation of the evacuation device to the escape, the time was measured in the order of Descending Life Line-Tilt-Down Rescue Line-Vertical Escape Chute-air safety mat. In the case of evaluating the evacuation time using evacuation mechanisms, the evacuation time was measured in the order of air safety mat-Tilt-Tilt-Down Rescue Line-Descending Life Line-Vertical Escape Chute. In the first and second experiments of the Descending Life Line, time differences were observed. The escape time using the Descending Life Line was reduced in the second experiment than in the first experiment. As shown in this result, education through experience has shown that behavioral confidence and time can be managed. The conclusion of this study is that the goal of safety education is to minimize human life and property damage. Therefore, in order to bring this effect to more people, it is necessary to make efforts to keep self-safe through experiential education.

A Study on Analysis of Installation on the Actual State and Improvement about a Descending Life Line (완강기의 설치 실태 분석 및 개선에 관한 연구)

  • Choi, Yong-Hyuk;Park, Sung-Jin;Kim, Tae-Gu;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.105-114
    • /
    • 2008
  • This study investigated problems found with the installation of a descending life line which is one of the compulsory fire escape apparatuses required by the revised "Fire Service Act" of 2006 for multi-use facilities and multistory buildings. It presents an analysis of the causes and improvement details for the problems classified by type of item. To achieve the purpose, the total 367 problem points are indicated. The problems of Installation are unsuitable window glass using the descending life line(34%), required passage device is not attached(23.7%), the installation location is with required operation(20%) and damaged descending life line(20%) were investigated. In particular, the study looks at the stress analysis range for cracking window glass which is required for people to escape in an emergency. People have questioned unsuitable window glass for using the descending life line among the problems with the installation. As a result of stress analysis, window glass thickness of the place where the descending life line is installed must be 3 or 6 mm. In addition, this study indicates substantial improvement measures for installing the descending life line so I will actually be used as a fire escape apparatus to protect human lives, and not just to formally meet the Fire Service Act.

A Study on the Visibility Measurement of CCTV Video for Fire Evacuation Guidance (화재피난유도를 위한 CCTV 영상 가시도 측정에 관한 연구)

  • Yu, Young-Jung;Moon, Sang-Ho;Park, Seong-Ho;Lee, Chul-Gyoo
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.12
    • /
    • pp.947-954
    • /
    • 2017
  • In case of a fire in urban large structures such as super high-rise buildings, evacuation guidance must be provided to the occupants in order to minimize human deaths and injuries. Therefore, it is essential to provide emergency evacuation guidance when a major fire occurs. In order to effectively support evacuation guidance, it is important to identify major items such as fire location, occupant position, escape route, etc. Also, it is important to quickly identify evacuation areas where residents can safely evacuate from a fire. In this paper, we analyze the CCTV video and propose a method of measuring visibility of the evacuation zone from the smoke caused by the fire in order to determine the safety of evacuation area. To do this, we first extract the background video from the smoke video to measure the visibility of the specific area due to smoke. After generating an edge-extracted image for the extracted background video, the degree of visibility is measured by calculating the change in the edge strength due to smoke.

기능성과 경제성을 겸비한 세종지하차도 설계

  • Jo, Seong-Tae;Song, Guk-Hwan;Lee, Hui-Geon
    • 한국도로학회지:도로
    • /
    • v.10 no.2
    • /
    • pp.58-67
    • /
    • 2008
  • 교통량이 많은 도심지내 장대 지하차도 건설은 교통정체 해소에 기여를 하지만 초기 공사비가 많이 소요되는 단점이 있다. 또한, 화재등 유고시 이용자의 안전을 최우선으로 고려되어야 한다. 즉, 장대 지하차도 건설에 있어서 경제성과 안전성이 함께 만족할 수 있는 건설 방안이 필요하다. 세종지하차도는 이러한 문제점을 극복하고자 다음과 같이 지하차도의 환기방식 및 단면, 포장형식, 사고 예방 및 발생시를 대비한 종합방재시스템을 구축하였다. $\cdot$환기방식은 종류식 환기방식의 경제성과 횡류식 환기방식의 제연성능을 겸비할 수 있는 조합형 환기방식과 Duct Arch 단면을 적용하여 공사비 절감 및 운영시 유지관리비를 획기적으로 절감하였다. $\cdot$지하차도 포장형식은 화재시 내화성이 우수하며 유독가스 발생이 없는 HPC(고성능 콘크리트 포장) 포장을 적용하여 이용자의 안전을 최우선으로 고려하였고 일반 아스팔트 포장 및 배수성 아스팔트 포장에 비해 우수한 성능과 공용수명을 가진 공법을 적용함으로서 유지보수비용의 절감을 가능하게 하였다. 또한, 콘크리트포장의 단점인 소음발생을 최소화하기 위해 타이닝과 그루빙을 적용하였다. $\cdot$지하차도내 화재 등 유고시 신속한 대피가 가능하도록 피난 연락문 간격을 167m 간격으로 설치하고 비상탈출계단 6개소를 확보하였다. 또한 노약자 및 환자의 지하차도 외부로 대피를 돕기 위해 비상엘리베이터 3개소를 설치하는 등 사고발생 시 종합적으로 대처할 수 있는 시스템을 마련하여 적용하였다.

  • PDF

연안·항만에서의 선박사고 예방 및 대응 지원 기술 개발 소개

  • Yang, Chan-Su;Jeon, Ho-Gun;Kim, Tae-Ho;Sin, Dae-Un;Park, Jong-Ryul
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.39-40
    • /
    • 2019
  • 우리나라는 국제해사기구(IMO)에 "여객선 탈출지도체계의 기술개발에 관한 정보"라는 안건(IMO SSE4/INF2)을 2017년에 제출한 바 있다. 이 의제에 소개된 지능형 선박 및 인명대피 안내시스템(SEGA)은 한국해양과학기술원의 주관으로 한국해양수산부의 지원을 받아 2016년부터 2020년 3월까지 약 4년간의 프로젝트로 개발 중에 있다. SEGA는 데이터 수집과 분석, 정보 표시의 프로세스를 자동화하여 우리나라 연안에서 항해 중인 선박에 비상상황이 발생할 경우 항해자의 의사결정을 지원하는 시스템이다. SEGA 시스템을 지원하기 위해 구축된 SEGA 서버와 데이터베이스는 해양기상정보, 수심정보, 해상교통정보를 처리 한다. 또한 비상상황 시 2차 사고를 방지하기 위해 선박이 대피 할 수 있는 장소에 대한 정보를 사용자가 확인할 수 있도록 알고리즘이 설계되어 있다. 인명안전을 위해 SEGA는 비상상황 시 선박내부 구조정보와 화재 등 변수사항들을 고려하여 승객들에게 빠른 탈출을 위한 최적대피경로를 제공하며, 원격탐사기술을 이용하여 선박주변의 익수자를 탐지하도록 개발 중에 있다. 보다 상세한 내용은 항해항만학회 VTS 특별세션에서 발표할 예정이다.

  • PDF

Proposal for Evacuee Guidance of Cloud-based Elevator System in Emergency Situation (클라우드 기반 비상탈출 시 피난유도 승강기시스템 제안)

  • Choi, Jun-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2015
  • Lifts are used as an essential means of transportation within the building in an emergency situation, when used as a means of escape, so expect a lot of research has been conducted high effect. Number of stories in the Seoul-rise building guidelines underground 7th floor, 53 ground floor, floor area $6,800m^2$, floor area $127,050m^2$, use is cultural and convention facilities and sales facilities, business facilities and accommodation (hotel), the construction of public housing (apartments) hagieneun not efficient to install elevators for evacuation mothada was determined separately in designing the lift is designed according to the standards of passenger lifts installed under a judgment as to use for evacuation. However, this does not include detailed design guidelines so far.[1] We propose the Evacuee Guidance of Elevator System that can be used as entering air equipment, sprinkler and smart phone evacuation system.

An experimental study on the smoke-spread region before reaching the critical velocity for the case of fires in tunnels employing longitudinal ventilation system (종류식 환기 시스템에서 임계속도 도달 전 스모크 확산 영역에 관한 실험적 연구)

  • Ki, Young-Min;Yoon, Sung-Wook;Yoon, Chan-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.526-535
    • /
    • 2006
  • An experimental study was carried out on a reduced scale tunnel model to grasp the behavioral feature of fire-induced smoke in the long tunnels. Based on Froude modeling, the 1/50 scaled tunnel model (20 m long) was constructed by acrylic tubes and paraffin gas was released inside the tunnel to simulate the 20 MW fire-induced smoke. me test results show, that after approximately 2 minutes of fire generation, was descended from the tunnel ceiling through the decrease of buoyancy, then it was symmetrically propagated about 90 meters for 4 minutes before jet fans were operated. The smoke was effectively controlled when the jet fans were operated and an air stream velocity was getting closed to reach a critical velocity (the minimum air velocity that requires to suppress the smoke spreading against the longitudinal ventilation flow during the tunnel fire situations). It was also found out that a range of smoke was spreaded about 3 meters from the origin of fire but the range was not propagated to the escape direction anymore. The early stage of the In operation, however, showed that the smoke was hardly controlled. It means that the operation of emergency ventilation system has many dangerous factors such as an intercepting breathing zone.

Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities (해양플랜트의 방화대책 및 설계기술 소개)

  • Koo, Myeong Jun;Choi, Jae Woong;Yoon, Ho Byung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • The dimensioning accidental loads have been selected through suitable quantitative risk assessment and generally utilized important factors for offshore facility design. The fire hazard can be quantified with dimensioning fire loads. The main purposes of fire protection are to maintain the functionality of safety systems within evacuation period and to prevent the escalation from initial fire to uncontrolled catastrophic fire. This paper introduces the applications and the design methods of active and passive fire protections as representative measures of fire protection of offshore facilities. The passive fire protection requires the high initial installation cost and much difficulty on the operation of facilities and their maintenance. The oil major clients have asked the design contractors of offshore facilities to optimize the amount of passive fire protection with relevant engineering technology recently.

Deep learning based optimal evacuation route guidance system in case of structure fire disaster (딥러닝 기반의 구조물 화재 재난 시 최적 대피로 안내 시스템)

  • Lim, Jae Don;Kim, Jung Jip;Hong, Dueui;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.11
    • /
    • pp.1371-1376
    • /
    • 2019
  • In case of fire in a structure, it is difficult to suppress fire because it can not accurately grasp the location of fire in case of fire. In this paper, we propose a system algorithm that can guide the optimal evacuation route in case of deep learning-based (RNN) structure disaster. The present invention provides a service to transmit data detected by sensors to a server in real time by using installed sensor, to transmit and analyze information such as temperature, heat, smoke, toxic gas around the sensor, to identify the safest moving path within a set threshold, to transmit information to LED guide lights and direction indicators in a structure in real time to avoid risk factors. This is because the information of temperature, heat, smoke, and toxic gas in each area of the structure can be grasped, and it is considered that the optimal evacuation route can be guided in case of structure disaster.

Measurement of the Visibility of the Smoke Images using PCA (PCA를 이용한 연기 영상의 가시도 측정)

  • Yu, Young-Jung;Moon, Sang-ho;Park, Seong-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.11
    • /
    • pp.1474-1480
    • /
    • 2018
  • When fires occur in high-rise buildings, it is difficult to determine whether each escape route is safe because of complex structure. Therefore, it is necessary to provide residents with escape routes quickly after determining their safety. We propose a method to measure the visibility of the escape route due to the smoke generated in the fire by analyzing the images. The visibility can be easily measured if the density of smoke detected in the input image is known. However, this approach is difficult to use because there are no suitable methods for measuring smoke density. In this paper, we use principal component analysis by extracting a background image from input images and making it training data. Background images and smoke images are extracted from images given as inputs, and then the learned principal component analysis is applied to map of as a new feature space, and the change is calculated and the visibility due to the smoke is measured.