• Title/Summary/Keyword: 화재위험성 평가

Search Result 438, Processing Time 0.025 seconds

Quantitative Risk Analysis for Railway Tunnels (철도터널 화재에 대한 정량적 위험도 분석)

  • Park, Jung Hyun;Shim, Cha Sang
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.3
    • /
    • pp.400-412
    • /
    • 2017
  • What is particularly noteworthy from Korean and foreign railway tunnel disaster prevention standards is that for the sake of rapid evacuation, more stringent standards for provision of evacuation passages, which require high cost, are being applied. Korean standards stipulate that passage installation should be determined in accordance with the level of risk through a QRA analysis of each tunnel with 1km or longer length. As, however, detailed application criteria as fire occurrence probability, fire occurrence scenario, size of fires and evaluation criteria for level of social risk are not available, additional costs may be incurred due to excessive design. Thus, standards of an appropriate level need to be established. With this backdrop, this study selects detailed application conditions of a reasonable and appropriate level through a study and analysis of relevant documents and analyzes the maximum length of tunnels to which the application of evacuation passages, or the application major evacuation promotion facilities, can be relaxed, together with a QRA analysis of model tunnels (for high speed rail) with different tunnel lengths. In addition, the QRA results on tunnels, including those on the Honam high-speed rail, and analysis results for the model tunnels, are compiled, ; the ultimate results are compared with Korean and other countries' standards related to evacuation promotion facilities, As a result, The appropriateness of application standards are reviewed. These results are expected to be utilized as basic material for establishing a reasonable disaster prevention plan that will consider safety and economies.

Review on Prior Evaluation for Terrorism Risk of High-rise Buildings (초고층건축물의 테러 위험도 사전평가에 관한 연구)

  • Seong, Bin;Lee, Yoon-Ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.293-316
    • /
    • 2013
  • Today's high-rise buildings are increasing concern about the safety and evacuation of people related to the fire and threat from outside. Terrorism breaking out in high-rise buildings, a symbol of the national economy results in a number of casualties, economic loss, social fear and damage to national status. That's why high-rise building has also emerged as a target of major terrorist attacks, compared to other types of buildings. We have 54 high-rise buildings in 15 regions over the country. The Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government have offered the guidelines to prevent terrorist attacks toward high-rise buildings. Since the 9/11 terrorist attacks, the U.S. Federal Emergency Management Agency (FEMA) has developed and taken advantage of the Risk Management Manual Series. According to this manual, pre-assessment is conducted for the prevention of terrorism and particularly in FEMA 455, risk of the surrounding areas, vulnerability, possibility from terrorist attacks are checked. After the check, experts classify the risk of terrorist attacks toward the high-rise buildings and according to the risk classification, architects, security experts and structure engineers can carry out terrorism prevention program for high-rise buildings. The U.K. NaCTSO has also offered the terrorism prevention guidelines. Therefore, the Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government should make more concrete guidelines for high-rise buildings such as what U.S. FEMA and U.K. NaCTSO implement, including prior evaluation technique for terrorism risk.

  • PDF

Development of Prediction of Electric Arc Risk using Object Dection Model (객체 탐지 모델을 활용한 전기 아크 위험성 예측 시스템 개발)

  • Lee, Gyu-bin;Kim, Seung-yeon;An, Donghyeok
    • Smart Media Journal
    • /
    • v.9 no.1
    • /
    • pp.38-44
    • /
    • 2020
  • Due to the high dependence on electric energy, electric fires make up a significant portion of fires in Korea. Electric arcs by short circuits or poor contact cause three of four electrical fires. An electric arc is a discharge phenomenon of electrical current between the insulators, which instantaneously produces high temperature. In order to reduce the fire due to electric arc, this study aims to predict the electric arc risk. We collected arc data from the arc detectors and converted into graphs based on temporal arc data. We used machine learning for training converted graph with different number of temporal arc data. To measure the performance of the learning model, we use the test data. In the results, when the number of temporal arc data was 20, the prediction rate was high as 86%.

Autoignition Characteristics of Limonene - Expanded Polystyrene Mixture (Limonene - Expanded Polystyrene 혼합물의 자연발화 특성)

  • 송영호;하동명;정국삼
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • In the reutilization process using limonene, the organic solvent to reduce volume of EPS, the AIT was measured with the variation of concentration and volume of mixture, in order to present the fund-mental data on the fire hazard assessment of limonene - EPS mixture at storage and handling. And ignition zone was compared with non-ignition zone. The equation related to AIT, activation energy and ignition delay time, used by the most scientific basis for predicting AIT values, was suggested using linear regression analysis as ln t = 0.704/T-5.819. And the equation related to concentration of mixture and AIT was also suggested to predict ignition hazard of combustible mixture using nonlinear regression analysis as $T_m/=248.32+69.27X+172.60X^2$. It enabled to predict ignition temperature according to variation of ignition delay time and concentration of mixture by the suggested equations.

긴급상황 시 선박 대피항로 선정 지원 기술 시뮬레이션 검증 : 비상투묘와 충돌위험도 중심으로

  • Sin, Dae-Un;Yang, Chan-Su;Jeon, Ho-Gun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.05a
    • /
    • pp.82-82
    • /
    • 2019
  • 해상에서 긴급상황 발생 시 선박운항자는 짧은 시간에 신속 정확한 의사 결정을 할 필요가 있다. 이를 위해서 해양사고(충돌, 좌초, 화재, 엔진고장, 조타고장) 심각성에 따른 대피항로(해경선, 비상투묘, 표류, 임의좌주, 주변선박) 선정 알고리즘을 설계하였고, 선박운항자를 위한 긴급대피지원안내 시스템을 개발 중에 있다. 본 연구에서는 대피항로 선정 지원 기술 중 비상투묘와 충돌위험도를 중심으로 시스템 적용 모델의 타당성의 평가하고 알고리즘의 신뢰성을 검증하였다. 비상투묘 지원 기술의 검증을 위해 국내외 해양사고 보고서 및 재결서를 분석하고 알고리즘에 적용해 결과를 비교하였다. 충돌위험도를 검증하기 위해 재결서의 선박 충돌 사고 사례를 시뮬레이션으로 재현하였고, 시뮬레이션 기록 데이터를 기반으로 PARK model, IWRAP MK2 프로그램을 이용해 충돌위험도를 평가하였다. 본 연구의 결과를 통해 해양사고 발생 시 선박과 인명 피해를 최소화할 수 있을 것으로 예상된다.

  • PDF

New Smoke Risk Assessment on Wood Treated with Silicone Compound (실리콘 화합물로 처리된 목재의 새로운 연기위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.16-27
    • /
    • 2019
  • A burning test was conducted on the smoke and combustion gases generated from cypress wood treated with sodium silicate, 3-aminopropyltrimethoxysilane sol, 3-(2-aminoethylamino)propylmethyldimethoxysilane sol, and 3-(2-aminoethylamino) propyltrimethoxysilane sol. The silicone compound sol was applied to each of the cypress wood specimens three times with a brush. The smoke and combustion generation gas were analyzed using a cone calorimeter (ISO 5660-1) and the smoke was also evaluated by applying new smoke risk assessment method. The smoke performance index (SPI) of the cypress treated with silicone compound increased 1.66 to 8.42 times and the smoke growth index (SGI) was 11.8 to 88.2%, respectively. The smoke intensity (SI) is expected to be 1.0~50.5% lower than that of the base specimens, resulting in lower smoke and fire hazards. The third maximum carbon monoxide (COpeak) concentration of the specimens treated with silicone compounds was 22.5~33.3% lower than that of the base specimens. On the other hand, it produced potentially fatal toxicity that was 1.48~1.72 times higher than the US Occupational Safety and Health Administration (OSHA) acceptance standard (PEL). Cypress wood itself produced a high carbon monoxide concentration, but the silicon compound played a role in reducing this level.

Mg-Al합금의 조성비율에 따른 발화온도특성

  • Han, U-Seop;Lee, Geun-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.77-77
    • /
    • 2013
  • 최근의 산업활동에서는 신규 원료 개발과 생산 효율성을 높이기 위하여 분체 공정이 증가하고 있는데, 미세 분진의 취급으로 분진운의 형성과 착화가 용이해지므로 분진폭발이나 화재 위험성이 증가하고 있다. 분진을 안전하게 사용하고 저장, 취급하기 위해서는 착화 전의 위험성 지표로서 최저발화온도(MIT ; Minimum Ignition Temperature)를 사전에 파악해 두는 것이 중요하다. 분진농도의 발화온도는 장치 내의 발화위험성이나 분진 취급 공정의 사고예방대책 관리를 위한 실용적 관점에서 중요하게 활용되는 폭발특성값이다. 또한 분진의 발화온도는 분진농도에 의존하며 농도변화에 따른 가장 낮은 온도를 MIT라고 한다. 본 연구에서는 화재폭발사고 빈도가 줄지 않고 있는 Mg 및 Mg-Al합금(60:40 wt%, 50:50 wt%, 40:60 wt%)을 대상으로 조성비율에 따른 최저발화온도를 실험적으로 조사하였다. Mg 및 Mg-Al(60:40 wt%), Mg-Al(50:50 wt%), Mg-Al(40:60 wt%) 시료의 평균입경은 142, 160, 151, $152{\mu}m$이다. MIT실험장치는 IEC 61241-2-1(Methods for Determining the Minimum Ignition Temperatures of Dust, 1994)에 준거하여 제작하여 사용하였다. 실험장치는 가열로, 분진운 시료홀더, 온도조절장치, 압축공기 제어장치 등으로 구성되어 있다. 구체적인 실험방법은 시험분진를 분진홀더에 장착하고 0.5 bar의 압축공기를 0.3 sec 동안 사용하여 일정 온도로 가열된 로의 내부로 분진운을 부유시킬 때에 분진운이 발화하여 가열로 하단부의 개방구에까지 화염이 전파하는지를 디지털비데오카메라로 기록, 평가하여 발화 유무를 판정하였다. Mg합금에 대한 MIT를 측정한 결과 $740^{\circ}C$가 얻어졌으며, Mg-Al(60:40 wt%)의 MIT는 $820^{\circ}C$로 조사되었다. 그러나 Mg-Al(50:50 wt%) 및 Mg-Al(40:60 wt%)에 대해서는 최대 가열로의 설정온도를 $890^{\circ}C$까지로 하여 농도를 변화시키면서 조사하였으나 발화가 일어나지 않았다. 문헌에 따르면 Mg입자 표면의 산화피막은 다공성으로 일정 온도에서 산화반응이 시간에 따라 직선적으로 증가하는데 반하여, Al의 산화피막은 보호 작용을 하여 일정 온도에서 산화반응속도가 표면과 내부의 농도 기울기에 의한 확산속도에 의존한다고 보고하고 있다. 본 연구결과를 토대로 Mg-Al합금의 발화특성을 고찰해 보면, Mg-Al합금에서 자기 전파성이 작은 Al성분의 증가는 착화지연이 증가하여 연소성이 감소하여 최저발화온도의 증가로 이어지는 것으로 추정되었다. 또한 발화온도는 주어진 조건의 온도장에서 분진이 존재하는 시간 길이에 따라 변화하므로, 발화온도를 실험적으로 측정하는 경우에는 측정장치나 방법에 따라 달라지므로 사업장의 현장에 발화온도를 적용하는 경우에는 장치 내의 분진의 존재시간을 고려할 필요가 있다.

  • PDF

Characteristics and Risk Assessment of Flame Spreading Over Metal Dust Layers (퇴적금속 분진층을 전파하는 화염의 연소특성과 위험성 평가)

  • Han, Ou-Sup
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • The wide use of metal dusts have been found in industrial field and many dust explosion accidents occur by fire spread of dust layer. In this study, we developed a new experimental device to examine fire and explosion characteristics of the dust layer. Aspects of the burning zone over metals(Mg, Zr, Ta, Ti, etc) and PMMA(Polymethyl methacrylate) dust layers have been investigated experimentally to clarify behaviors (Spread rate and quenching distance) and effects of $N_2$ surrounding gas on the fire spread over metal dust layers. From the experimental result, it was found that the spread rate of metal dusts is larger than PMMA, the dependability of spread rate over the thickness of dust layer is small, and the minimum oxygen concentration of spread flame over Mg dust layer is 3.6-3.7 vol%. Since high correlation between the spread rate and the reciprocal of quenching distance was seen, relative risk prediction in those inflammable parameters can be predicted.

Consequence Analysis of Hydrogen Blended Natural Gas(HCNG) using 3D CFD Simulation (CFD를 활용한 수소-천연가스 혼합연료에 대한 피해영향 분석)

  • Kang, Seung-Kyu;Bang, Hyo-Jung;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2013
  • This study evaluated comparison of the risk according to the type of fuel by three-dimensional simulation tool(FLACS). The consequence analysis of fire explosion and jet-fire was carried out in the layout of a typical high-pressure gas filling stations using CNG, hydrogen and 30%HCNG. Under the same conditions, hydrogen had a 30kPa maximum overpressure, CNG had a 0.4kPa and HCNG had a 3.5kPa. HCNG overpressure was 7.75 times higher than the CNG measurement, but HCNG overpressure was only 11.7% compared to hydrogen. In case of flame propagation, hydrogen had a very fast propagation characteristics. On the other hand, CNG and HCNG flame propagation velocity and distance tended to be relatively safe in comparison to hydrogen. The estimated flame boundary distance by jet-fire of hydrogen was a 5.5m, CNG was a 3.4m and HCNG was a 3.9m.

Evaluation of Fire Investigation as the Separation Distances for Several Types of Insulation Panels (단열패널 종류별 이격거리에 따른 화재감식 평가)

  • Kim, Jeong-Hun;Kim, Da-Seul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.403-412
    • /
    • 2021
  • Despite strengthening requirements for fire retardancy and applied buildings of insulation panels, the number of fires and influence of damage have increased. In this study, the thermal effects were evaluated as the separation distances, and three types of EPS panel, glass wool panel, and gypsum board panel were then selected. Temperature sensors on the panels were installed vertically from the ground. The fire source on the lamination layer of lumber was ignited by changes in the separation distances (0 cm, 25 cm, 50 cm) from the panels. The test results suggested that the maximum temperature was 349 ℃ in the EPS panel. The inside/outside shape changes were limited by the height of the low and middle positions until the critical point of a 25 cm separation distance. Furthermore, the combustion marks appeared after 500 s on average, and then the EPS panel with a high fire strength showed a broad "U type" pattern, glass wool panel, and gypsum board panel showed medium or narrow "V type" pattern. Therefore, the acquired data can provide valuable information for evaluating the fire risks and verifying fire investigation from buildings composed of these insulation panels.