• Title/Summary/Keyword: 화재안전성

Search Result 1,179, Processing Time 0.033 seconds

Application of Fire Risk and Fire Risk Rating Assessment for Four Species of Wood According to Chung's Equation-XII (Chung's Equation-XII에 의한 목재 4종의 화재위험성 및 화재위험성 등급 평가 적용)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.35 no.1
    • /
    • pp.29-36
    • /
    • 2024
  • The fire risk and fire safety of four types of wood were comprehensively evaluated according to Chung's equation-XII. White ash, willow, fraxinus mandshurica, and sagent cherry trees were selected as test specimens. A cone calorimetery (ISO 5660-1) was used to examine the combustion characteristics of the test piece, and finally, the fire risk rating (FRR) was predicted using the fire risk index-XII (FRI-XII). The predicted fire performance index-X (FPI-X) and fire growth index-X (FGI-X) ranged from 469.03 to 1109.73 s2/kW and 0.0009 to 0.0280 kW/s2, respectively. Additionally, the fire performance index-XI (FPI-XI) and fire growth index-XI (FGI-XI) ranged from 0.41 to 0.97 and 1.11 to 3.11, respectively. The fire risk index-XII (FRI-XII), representing a fire risk rating, showed that the fire risk of frasxinus mandsurica tree (FM) was very high at 7.60 (fire risk rating: D). And it was compared with Chung's equation-IX, fire risk index-IX (FRI-IX). The fire risk ratings according to FRI-IX and FRI-XII were generally high for willow and frasxinus mandsurica trees. Additionally, the results of FRI-XII and FRI-IX had a similar relationship, and the size of each fire safety rating closely matched each other.

가정용 소형 단상변압기 안전성 실태 분석

  • Kim, Seong-Sam
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.188-189
    • /
    • 2013
  • 본 논문에서는 산업현장과 교육시설에서의 가정용 소형 단상변압기의 규격품 사용 여부와 운영상의 안전성 실태를 분석하였다. 전기용품 안전 관리법에 따른 법정인증을 받지 않은 제품이 5개 조사되었으며, 단자 체결형 변압기의 경우 전원선 접속 불량(헐거움), 설치 및 고정 불량, 접지 미체결(누락), 전압조정 핸들 파손, 변압기 상부 가연물 방치가 주요 불합리 항목으로 조사되었다.

  • PDF

PU/Layer Silicate 복합체의 난연성

  • 곽봉신;김정훈;강영구
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.311-315
    • /
    • 2002
  • Polyurethane 발포체는 우수한 단열 및 흡음특성 그리고 반응물질인 polyol과 isocyanate의 성분 및 배합비에 따라 여러가지 제품군으로 특성 설계가 가능하여 LNG 저장탱크, LNG 유조선의 cryogenic insulator, 육상 및 해상용 냉동 및 냉장시설물, 가전제품, 건축단열판넬 등에 널리 사용되고 있다. 그러나 난연성의 결여로 화재 발생시 급격한 연소반응과 유해가스 발생을 동반하여 화재안전 및 건강보건상 중대한 단점을 가지고 있다. 본 연구진은 PU발포체의 물성개선을 통한 난연특성 연구의 일환으로서 montmorillonite, hectorite, vermiculite의 layer silicate를 urethane 원료물질과 혼성발포 공정을 통해 난연복합체를 제조하여 UL94V, LOI, Morphology 등의 시험을 수행하였다.(중략)

  • PDF

Multivariate Analysis of Fire Prevention Activities, Special Investigations of Fire Safety, and Fire Safety Management by the Apartment Buildings Management Methods and Inspection of Firefighting Facilities (공동주택 관리방식과 소방시설의 점검에 따른 예방활동·화재안전특별조사·소방안전관리의 다변량 분석)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.489-502
    • /
    • 2020
  • This study shows the difference between groups with multivariate analysis of fire prevention activities, special investigations of fire safety, and fire safety management according to the management method of apartment houses and the inspection of firefighting facilities. The results of the analysis are as follows. First, there was a significant difference in fire prevention activities according to the quality of inspection of firefighting facilities. This means that fire prevention is high if the fire safety manager's ability to inspect firefighting facilities is excellent and the fire safety inspection is conducted in accordance with national fire safety standards and checklists. Second, there was a significant difference in the fire safety special investigation according to the management method of the apartment buildings. The manual operated by the management entity and the management entity's management and execution help the organization members to expedite work. This expedition of work creates a high possiblity to get a good evaluation from the special investigation of fire safety. Third, analysis of fire prevention activities showed a significant interaction between the inspection of firefighting facilities and the management method of apartment buildings. The analysis shows that that there is a positive correlation between the level of fire prevention and both the fire safety manager's ability to inspect firefighting facilities and the degree to which the inspection is conducted to meet national fire safety standards.

A study on the optimized design of the alarm valve with strength safety (강도 안전성을 고려한 알람 밸브의 최적설계에 관한 연구)

  • Kim, Tae-Hwan;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.332-336
    • /
    • 2010
  • 알람밸브는 습식 스프링쿨러 시스템에 필수적으로 사용되는 밸브로써 알람밸브의 오작동 및 고장 등은 치명적인 인명 및 재산의 손실을 가져 올 수 있으므로 소방밸브의 안전성 기준은 매우 높다. 이에 현재 제작되고 있는 알람 밸브는 강도 안전성 측면에서 매우 안전하게 설계가 되어있으며 주철 재질로 주물을 통해 제작된다. 하지만 이러한 과도한 안전설계는 오히려 과도한 무게의 부담으로 시스템에 무게 부담을 주기도 한다. 그러므로 본 논문에서는 밸브의 무게를 경감시키면서 충분한 강도안전성을 가지는 밸브의 설계안을 제시하고 유한요소 해석을 통하여 그 결과를 살펴보았다.

  • PDF

탐방 - 한미은행 인천본부

  • Lee, Mi-Suk
    • 방재와보험
    • /
    • s.91
    • /
    • pp.70-72
    • /
    • 2001
  • 최고 경영진의 전폭적인 지지와 방화관리자의 투철한 사명감이 합쳐져 최고의 안전성, 편리성, 쾌적함을 추구하고 있는 한미은행 인천본부 시설관리팀은 화재 및 기타 재해로부터 인명과 재산을 보호하는 것을 목적으로 건물 내에서 일어나는 사소한 일까지도 세심하게 관리하여 "고객만족 만점"을 추구하고 있다.

  • PDF

아트륨 빌딩에서의 사무실과 아트륨간의 화재확산에 관한 연구

  • 이수경;김종훈;고한목
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.85-90
    • /
    • 1997
  • 최근 시대적 사회적 요구에 의해 다양한 통신써비스기능, 오피스 오토메이션 기능, 빌딩 오토메이션 기능 및 건축환경이 고려된 인텔리젼트 빌딩이 국내에서도 대기업의 자사 빌딩을 중심으로 도입되고 있다. 인텔리젼트빌딩은 사무근로자의 쾌적한 근무환경을 제공하기 위한 건축설비적 배려 외에도 아트륨이라는 대공간이 제공되는 데, 그 특성상 방화적 측면에서 볼 때 불리한 점을 가지고 있다. 이러한 아트륨의 안전성을 확보하기 위해 선진국에서는 아트륨을 통한 화재확산에 관한 많은 연구가 있었고, 최근에는 아트륨과 사무실간에는 방화구획을 하지 않고 설비적 보완으로 가능하도록 하고 있다. 본 논문에서는 건축 및 설비적 대응을 통해 설계 모델을 설정하고 그것이 안전성을 가지고 있다는 것을 소프트웨어를 이용한 화재 시뮬레이션을 통해서 입증하여 국내 건축법령에서의 방화관련 규정의 보완이 필요함을 제시하고자 한다. (중략)

  • PDF

Study on the effective response method to reduce combustible metal fire (금속화재 위험감소 방안에 관한 이론적 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.600-606
    • /
    • 2018
  • A class D fire or combustible metal fire is characterized by the presence of burning metals. Only certain metals or metal compounds are flammable, including sodium and lithium. General fire extinguishing agents, such as dry chemical powder, water-based fire extinguish agents, and carbon dioxide, cannot be used in class D fires. This is because these agents cause adverse reactions or are ineffective. In addition, the amount of usage of combustible metals is increasing due to continuous development of the semiconductor and fuel cell industries. Despite this, Korea does not have standards and laws related to combustible metal fires. This paper suggests directions of the class D fire management policies to reduce the class D fire risk and impact by analyzing the standards and laws related to class D fires and combustible metal fire cases. The factors to make laws on class D fire prevention and response systems, and management system of dry sand were determined. These results may be used to help reduce the risk of class D fires and improve the response abilities.