• 제목/요약/키워드: 화재시나리오

Search Result 283, Processing Time 0.023 seconds

A Study on ASET(available safe egress time) for Subway Station of Light Weight Railcar Using FDS (FDS를 이용한 경량철도 지하역사의 피난허용시간 연구)

  • Kim, Chi-Hun;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.361-366
    • /
    • 2011
  • 본 연구에서는 무인운영이 예정되어 있는 경량철도 지하역사 화재 시 안전대책을 강구하기 위하여 다양한 시나리오의 화재상황을 모사하여 FDS 사용코드를 이용해 화재유동현상을 분석하였다. 해석경계조건은 전동차 내부공간을 포함한 지하 3개 층과 설계에 반영된 환기설비를 적용하였으며, 약 500만 개의 격자를 34개 블록으로 나누어 계산하였다. 비상탈출 동선을 파악하여 주요 위치에서 피난경로상의 각 층 바닥으로 부터 1 m 높이의 한계온도와 연기층의 도달시간을 시나리오 별로 분석하여 보았다.

  • PDF

A Study on the Analysis of Fire Risk according to the Operation Scenario of Fire Safety Equipment (화재안전설비 작동 시나리오에 따른 화재위험분석에 관한 연구)

  • Jin, Seung-Hyeon;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.139-140
    • /
    • 2022
  • This study aims to present basic data for fire risk assessment. In the existing fire risk assessment, the operation of fire safety facilities is not considered. In addition, there is a lack of data on the fire growth rate to predict the spread of fire. Therefore, this study intends to build a fire scenario using fire statistics data. In addition, the fire growth rate is to be derived in consideration of the floor area of burnout and the cause of fire.

  • PDF

Uncertainty Evaluation of Fire Modeling Analysis Results (화재모델링의 불확실도 평가방안)

  • Park, Jong-Seuk;Lee, Chang-Ju
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.239-242
    • /
    • 2011
  • NFPA-805 불확실도 분석 요건에 따른 경수형 원전 스위치기어실 모터제어반의 화재시나리오에 대한 입력변수 불확실도 평가를 수행하였고 이를 통해 화재모델링의 불확실도 평가방안을 제시하였다. 화재모델링은 FDS5를, 불확실도분석은 MOSAIQUE를 사용하였고 Wilks 방법에 근거하여 93회의 latin hypercupe 샘플링을 수행하였다. 스위치기어실 케이블의 최소 평균손상시간은 212초로 예측되어 화재발생시 스위치기어실의 화재진압은 약 4분 이내에 이루어져야 하는 것으로 확인되었다.

  • PDF

Analyses of Scenarios Based on a Leakage of Highly Compressed Air and Fire Anticipated in CAES (Compressed Air Energy Storage) Facility (압축공기에너지저장 시설에서 발생 가능한 압축공기 유출 및 화재 시나리오 분석)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.568-576
    • /
    • 2015
  • In this study, scenarios based on the leakage of highly compressed air and fire occurrence turned out to be high risks in an operation stage of CAES facility were constructed and estimated. By combining Bernoulli equation with momentum equation, an expression to calculate an impact force of a jet flow of compressed air was derived. An impact force was found to be proportional to the square of diameter of fracture and the pressure of compressed air. Four types of fire scenarios were composed to evaluate an effects that seasonal change and location of fire source have on the spread behavior of smoke. Smoke from the fire ignited in the vicinity of CAES opening descended more quickly below the limit line of breathing than one from the fire occurred 10 m away from CAES opening, which is expected to occur due to a propagation of wave front of smoke. It was shown that a rate of smoke spread of the winter fire is faster than one of the summer fire and smoke from the winter fire spreads farther than one of the summer fire, which are dependent on the direction of air flow into access opening. Evacuation simulation indicated that the required safe evacuation time(RSET) of the summer and winter fires are 262, 670 s each.

A study on the evaluation of fire safety according to the ventilation mode in a train fire at the subway platform (지하철 승강장에서 열차 화재시 제연모드에 따른 화재 안전성 평가 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.293-310
    • /
    • 2020
  • The purpose of this study is to present the most effective smoke exhaust mode by comparing the quantitatively evaluated risks according to the smoke exhaust mode when a train fire occurs in a subway platform. Therefore, applying the typical subway platform as a model, train fire scenarios are developed with the evacuation start time and location of the fire train for each exhaust mode. The fire accident rates (F) are calculated and the number of fatalities (N) was quantitatively estimated by fire analysis and evacuation analysis for each scenario. In addition, the F/N curve compared with the social risk assessment criteria and the following conclusions were obtained. In the event of a train fire at the subway station platform, the evacuation must start up within 600 s in maximum to ensure the evacuees' safety. To secure evacuation safety, it is advantageous to operate the HVAC system of the platform in the air-supply mode at station without TVF. Comparing the F/N curve for each exhaust mode with the social risk criteria, it turned out that the risk significantly exceeds the social risk criteria in case of no mechanical ventilation. As a result, this paper shows that the ventilation mode in which TVF are exhausted and HVAC system is operated in the pressurized mode are the most effective smoke exhaust mode for ensuring evacuation safety.

화재모델링의 PIRT 적용성 검토

  • Ji, Mun-Hak;Kim, Yun-Jung;Kim, Hyeong-Taek
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.42-43
    • /
    • 2013
  • 원전 방화지역의 화재리스크는 존모델 또는 필드모델을 사용하지만 화재 시나리오 또는 현상의 고찰 없이 사용되어온 측면이 있다. 한편 PIRT 기법은 전산코드의 적합성을 평가하고 최신기술과 입력자료의 타당성을 분석하여 우선순위 등급을 선정한다. 따라서 PIRT 기법을 화재모델링 분석에 적용할 경우 화재모델링 분석방법의 개선과 결과 값의 신뢰성을 높일 수 있는 기술로 활용할 수 있다.

  • PDF

구획 화재시 창유리 파괴 현상에 관한 실험적 연구

  • 김종훈;이수경;최종운;이정훈
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.101-106
    • /
    • 1998
  • 현대사회가 급속한 발전을 이룩하면서 화재의 발생은 증가추세에 있다. 화재의 예방과 진압장비의 개발을 위해서는 실내화재현상에 대한 연구와 이해가 필요하다. 대부분의 실내화재 관련 현상에 대하여서는 많은 연구가 이루어졌고, 이러한 연구를 바탕으로 컴퓨터 시뮬레이션과 같은 화재 현상의 예측기법을 발전 시켜왔으며, 거의 실제에 가깝게 발전하고 있으나, 아직까지도 규명이 확연히 되지 않고 있는 부분은 창유리의 파괴현상이다. 본 연구는 구획화재시 창유리의 파괴현상을 실제에 근접한 시나리오를 설정한 후 실험을 통해 고찰하고자한다. 또한 파괴시간 예측 프로그램인 BREAKl의 분석 결과와 실험치의 비교도 아울러 실시하여 그 적용성을 판단해보자 한다. (중략)

  • PDF

An Availability Assessment of Protection Wall Installed in LPG Filling Station (LPG 충전소 내 설치된 방호벽의 효용성 평가)

  • Lee, Jin-Han;Jo, Young-Do;Moon, Jong-Sam;Kim, Lae Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.38-45
    • /
    • 2018
  • Jet fire, pool fire, and vapor cloud explosion are major accident scenarios in LPG filling station. The protection wall would mitigate radiation effect in a jet fire. In case of a pool fire, the protection wall would restrict expanding the pool area. The protection wall might both obstruct the dispersion of released vapor and protect blast overpressure in a vapor cloud explosion scenario. In this paper, An availability assessment method of the protection wall how much reduce damage to receptors is proposed. Additionally application cases are presented for the effectiveness of protection wall in the LPG filling station. The study shows that the protection wall can effectively reduce the death probabilities of receptors located behind the wall in cases of the jet fires and the vapor cloud explosions.

Hazard analysis by fire simulation in an apartment fire (화재 시뮬레이션을 이용한 아파트 화재 위험성 분석)

  • Kim, Tae Kwon;Cha, Woo Sub
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.383-388
    • /
    • 2014
  • This study predicts damaging risk factors in apartment fire situation by using CFAST. The software was developed by Building and Fire Research Lab, that is government affiliated organization of the National Institute of Standards Technology. This analysis scenarios werec well verified by experimental results. Situation of the living room and the second room as well as the bedroom tends to be qualitatively the same with the experimental data. In case of apartment fire, it is predicted that they have been got into trouble with dizziness, badly vomiting and paralysis symptoms due to short oxygen and excessive carbon dioxide when persons were left out in the living room or second room.

A Study on Distribution of Smoke Temperature in a Road Tunnel with Scenarios (시나리오에 따른 터널 내 연기 온도 분포 특성에 관한 연구)

  • Ju, Eun-Hye;Yoon, Yong-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.160-161
    • /
    • 2013
  • 환기구의 유무, 환기구 설치 대수, 환기구 용량 등을 변수로 한 5개의 시나리오를 가정하여 터널내 연기 온도 분포의 특성을 분석하였다. 해석 결과 환기구의 설치 대수를 증가시킴에 따라 연기 온도는 감소하였으며, 환기구가 2대에서 3대로 증가하는 경우 온도 감소 효과는 크지 않은 것으로 나타났다. 환기구의 용량을 증가시키는 경우 환기구를 설치하는 것과 유사한 온도 감소 효과를 나타내었다.

  • PDF