• Title/Summary/Keyword: 화재손상분석

Search Result 106, Processing Time 0.024 seconds

Evaluation of Material Properties of Fire-damaged Concrete Under Post-fire Curing Regimes Using Impact Resonance Vibration Method (충격 공진 기법을 이용한 화재 손상 콘크리트의 재양생 조건별 재료물성 평가)

  • Park, Sun-Jong;Yim, Hong Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.42-48
    • /
    • 2017
  • When concrete structures expose to fire, the structures were damaged accompanied with degradation of material properties of concrete. In order to determine the reuse of fire-damaged concrete structures, it is needed a careful determination considering conditions of fire damage, such as exposure temperature and exposure time, and also potential to restore fire damage. This study investigates on the evaluation of residual material properties of fire-damaged concrete under different post-fire curing regimes. An experimental study was performed on concrete samples to measure the dynamic elastic modulus by the impact resonance vibration method. Upon the experimental results, the evidence of restoration of material properties was confirmed on specific post-fire curing regimes, higher humidity conditions. Additionally, a correlation analysis was performed on the dynamic elastic modulus with the tensile strength for identifying the effects of post-fire curing regimes on both material properties of fire-damaged concrete.

자율운항선박 손상 및 화재 대응 시스템 전시 모듈 개발

  • 이상만;이대학;최정웅;이민규;김승태
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.276-278
    • /
    • 2022
  • 자율운한선박에 설치되는 침수 및 화재 센서들의 정보를 활용하면 위기대응 상황 판단 및 안전성 분석이 가능하다. 본 연구에서는 대상 선박에 설치된 센서 정보와 대상 선박의 시뮬레이션 해석정보를 활용하여 손상 및 화재로 인한 위기 상황을 자동으로 인지하고 승조원에게 대응과 안전에 관한 정보를 전시하여 제공하는 모듈을 개발하였다.

  • PDF

Analysis of Factors Influencing Fire Damage to Concrete Using Nonlinear Resonance Vibration Method (비선형 공진기법을 이용한 콘크리트의 화재 손상 영향인자 분석)

  • Park, Gang-Kyu;Park, Sun-Jong;Yim, Hong Jae;Kwak, Hyo-Gyoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.150-156
    • /
    • 2015
  • In this study, the effects of different mix proportions and fire scenarios (exposure temperatures and post-fire-curing periods) on fire-damaged concrete were analyzed using a nonlinear resonance vibration method based on nonlinear acoustics. The hysteretic nonlinearity parameter was obtained, which can sensitively reflect the damage level of fire-damaged concrete. In addition, a splitting tensile strength test was performed on each fire-damaged specimen to evaluate the residual property. Using the results, a prediction model for estimating the residual strength of fire-damaged concrete was proposed on the basis of the correlation between the hysteretic nonlinearity parameter and the ratio of splitting tensile strength.

An Experimental Analysis on Damage patterns of a Mobile Phone Caused by Artificial Manipulation (휴대전화의 인위적 손상 형태에 대한 실험적 분석)

  • Song, Jae-Yong;Nam, Jung-Woo;Sa, Seung-Hun;Kim, Jin-Pyo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.306-309
    • /
    • 2011
  • 본 연구에서는 정확한 화재원인 분석 및 사기범죄 여부 확인을 위하여 극초단파를 직접 휴대전화에 조사하고, 이때 발생되는 휴대전화의 손상형태를 분석하였다. 극초단파 조사를 위하여 전자레인지를 이용하였으며, 전자레인지의 마그네트론에서 발생되는 2.45 GHz의 극초단파가 휴대전화에 인가될 때 휴대전화의 손상형태를 분석하였다. 실험 결과, 휴대전화에 극초단파를 조사하는 경우, 조사 시간이 길어짐에 따라 심하게 손상되는 경향을 나타내었으며, 특히, 폴더의 힌지 부분 및 인테나 부분과 같이 금속이 설치되는 부분이 심하게 열변형되는 결과를 나타내었다. 휴대전화의 배터리 부분은 외함이 열변형되는 것 이외에 배터리의 손상이나 폭발 등은 발생되지 않는 것으로 평가되었다.

  • PDF

Uncertainty Analysis of Fire Modeling Input Parameters for Switchgear Room of Nuclear Power Plants (원자력발전소의 스위치기어실 화재모델링 입력모수 불확실성 분석)

  • Kang, Dae-Il;Park, Jong-Seuk;Han, Sang-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.53-60
    • /
    • 2011
  • 본 논문에서는 원자력발전소의 스위치기어실 화재로 인한 케이블 손상시간과 케이블 온도를 평가하기 위해 화재모델링 입력모수 불확실성 분석을 수행하였다. 화재모델링은 FDS 5.5를 사용하였으며 입력모수 샘플링은 Wilks 식에 따라 93회를 수행하였다. 단순히 입력모수 평균 값을 사용한 화재모델링 분석결과는 화재모델링 불확실성 분석결과보다, 케이블 손상시간은 최대 1.6배 늦게, 케이블 온도는 최대 0.45배 낮게 평가될 수 있는 것으로 나타났다.

  • PDF

A Study on MDA Analysis & blood chemical test for Mouse which were exposed HF Gases from Fire (화재로 인한 불화수소(HF)가스에 노출된 마우스의 혈액생화학분석 및 MDA분석을 통한 세포손상에 관한 연구)

  • Cho, Nam-Wook;Oh, Eun-Ha
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.58-66
    • /
    • 2013
  • Among the risks which can be faced with fire, combustion toxicity is a significant influence on the survival. Fire toxicity researches have been limited generally on the lethal aspects. In this study, HF gas which can be generated from fire, and also found in general industrial site was used for analysis. Blood analysis and biochemistry analysis performed to find internal demage of experimental animals which were used for measuring average activity stopping time from Animal test(KS F2271: Gas hazard test). In addition, Using the malondialdehyde analysis, indicators of oxidative damage, we had quantitative analysis to target lymphocyte for measuring the oxidative damage caused by toxic substances.

CCDP Evaluation of the Eire Areas in NPP Applying CEAST Model (II) (화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가(II))

  • Lee Yoon-Hwan;Yang Joon-Eon;Kim Jong-Hoon;Kim Woon-Byung
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.20-27
    • /
    • 2005
  • This paper evaluates the fire safety level of eight pump rooms in the nuclear power plant using a fire model, CFAST We estimate the Conditional Core Damage Probability (CCDP) of each room based on the analyzed results of CFAST Eight rooms located on the primary auxiliary building of the nuclear power plant are high pressure safety injection pump room A/B, low pressure safety injection pump room Am. containment sprdy pump room A/B, and motor-driven auxiliary feed water pump room A/B. The upper layer gas temperature of each room is estimated and the integrity of cable is reviewed. Based on the results, the integrity of the cable located at the upper part of compartment is maintained without thermal damage. The Conditional Core Damage Probability Is reduced to half of the old values. Accordingly, the fire safety assessment for eight pump rooms using the fire model will be capable of reducing the uncertainty and to develop a more realistic model.

Uncertainty Evaluation of Fire Modeling Analysis Results (화재모델링의 불확실도 평가방안)

  • Park, Jong-Seuk;Lee, Chang-Ju
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.239-242
    • /
    • 2011
  • NFPA-805 불확실도 분석 요건에 따른 경수형 원전 스위치기어실 모터제어반의 화재시나리오에 대한 입력변수 불확실도 평가를 수행하였고 이를 통해 화재모델링의 불확실도 평가방안을 제시하였다. 화재모델링은 FDS5를, 불확실도분석은 MOSAIQUE를 사용하였고 Wilks 방법에 근거하여 93회의 latin hypercupe 샘플링을 수행하였다. 스위치기어실 케이블의 최소 평균손상시간은 212초로 예측되어 화재발생시 스위치기어실의 화재진압은 약 4분 이내에 이루어져야 하는 것으로 확인되었다.

  • PDF

Analysis on Vehicle Fires Caused by Damage of Diesel Particulate Filter (DPF) (매연저감장치 손상에 기인한 차량화재 사고사례 분석)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.70-76
    • /
    • 2012
  • This paper deal with vehicle fire caused by damage of diesel particulate filter (DPF) on diesel passenger vehicles. In order to reduce particulate matters included exhaust gases, a DPF in the exhaust system were installed diesel vehicles. A DPF was broken by excessively trapped particulate matters, regeneration error with a malfunction of ECU and defect of suction system such as swirl valve. If the DPF was broken, hot exhaust gases was released to the bottom of vehicle and released hot exhaust gases lead to occur the fire through combustible materials around the exhaust system. When a fire happened in the diesel vehicle caused by damage of DPF, silicate inorganic compounds were attached to the exhaust ventilation pipe and muffler. The silicate inorganic compounds were created by DPF combustion consisting of raw material ceramics. If the silicate inorganic compounds attached to the tail pipe in the diesel passenger vehicles, its fire cause will be assumed damage of DPF.