• Title/Summary/Keyword: 화염처리장치

Search Result 12, Processing Time 0.021 seconds

Investigation of Exhaust Facility of Liquid Rocket Propulsion System (액체로켓 추진기관의 후류처리장치 고찰)

  • Cho, Nam-Kyung;Lee, Kwang-Jin;Han, Young-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.133-138
    • /
    • 2012
  • Exhaust facility has basically the role of flame deflector, and considering additional functions, it can be classified by noise/emission suppressor and altitude simulation facility. In this paper, principles of flame deflector, jet pump, emission suppression are presented for exhaust treatment facility. Principles of noise suppression caused by Mach wave mitigation, jet energy mitigation by water evaporation and condensation are shown. In addition, a concept of vertical exhaust treatment facility is presented applying basic principles aforementioned.

  • PDF

Measurement of Flame Propagation Velocity Using an Ion Current Apparatus Design (이온전류장치 설계에 의한 화염전파속도 측정)

  • 정진도;이충섭;권병철
    • Journal of Energy Engineering
    • /
    • v.3 no.1
    • /
    • pp.62-69
    • /
    • 1994
  • 화염중에 존재하는 이온 및 전자의 전기적 성질을 이용하여 연소실내의 화염전파속도를 파악하기 위해 실린더 헤드에 이온 프로브를 삽입하여 천연가스 및 가솔린의 화염전파속도를 측정하였다. 본 연구에 이용된 이온전류장치 설계에 의한 방법은 광학적 측정 장비에 비해 간단하며 쉽게 측정할 수 있고 가격도 저렴하고 응답성도 우수하였다. 이온 프로브의 제작과 신호처리에 관한 기초적인 지식을 얻었으며 천연가스 및 가솔린의 연소시 연소압력의 상승지점과 이온발생지점이 일관성있게 나타났다. 기관회전수의 증가에 따라서 연소실내의 화염전파속도가 증가했으며 같은 연소조건이라고 할 수 있는 동일 기관회전수, 당량비의 조건에서 점화시간에 대한 화염전파속도를 비교해 보면 메탄의 경우가 이론치보다 6 ms∼9 ms 정도 늦었다. 또한, 메탄가스 및 가솔린에 대해 이온 전류강도 및 화염 도달시간을 측정하였으며 연소실 벽면에서는 열전달에 의한 냉각효과로인해 화염 전파속도 및 이온농도가 감소했다.

  • PDF

Design Study on the Flow Characteristics of a Gas Management System for a Vertical Launching System (함정 수직발사대 화염처리장치 형상에 따른 유동특성 연구)

  • Yang, Young-Rok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.712-717
    • /
    • 2013
  • The gas management system for a vertical launching system must be safely managed within a ship. The plenum and uptake are capable of containing and surviving a full-burning restrained firing without loss of gas management integrity. To secure the safety, the pressure characteristics with a supersonic under-expanded jet on a gas management system are numerically investigated using computational fluid dynamics. The results of present analysis and the preliminary design of the gas management system are described in this paper.

Visualization of luminescent radicals in the flame by image processing (영상처리에 의한 화염 발광 라디칼의 가시화)

  • 김경찬;김영민;정주영;김태권
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.264-269
    • /
    • 1998
  • The Measurement of concentration patterns for $C_2$, CH and OH radicals in the premixed propane-air flame could be managed through an image processing technique. This technique was applied to the three kinds of flames on a bunsen burner-mixtures of fuel to be lean, optimum and excessive respectively. The image processing system was complished by treating single wavelength flame images around the eac radical luminescence band, which was obtained by using a set of narrow band pass filters, an image intensifier, CCD and PC. It was possible to observe and predict the reaction zone and the concentration distribution of the radicals, Spatial distribution of each radicals in the raaction zone gave us enough informations to analyze the reaction mechanisms in $C_mH_n$ combustion process. According to this informations, the image of $C_2$ radical exists at front zone, following the images of CH and OH radicals at downstream.

  • PDF

Effect of Atmospheric Pressure Flame Plasma Treatment on Surface and Adhesive Bonding Properties between Steel Plate and Rubber (대기압 화염 플라즈마 처리가 강판의 표면 및 고무와의 접착특성에 미치는 영향)

  • Ryu, Sang-Ryeoul;Lee, Dong-Joo
    • Composites Research
    • /
    • v.23 no.5
    • /
    • pp.1-7
    • /
    • 2010
  • To increase the adhesive strength of acrylonitrile butadiene rubber(NBR) and steel plate, the atmospheric pressure flame plasma(APFP) treatment device is applied. The effect of various conditions(processing velocity and distance) is experimentally investigated to ascertain the optimum conditions to yield the best adhesive properties. It is found that the optimum distance between burner port and steel plate is 40mm and the optimum processing velocity is 50m/min at given condition. When the surface is coated twice with the bonding agent, the adhesion strength of APFP treated steel plate is increased to about 20.5%. It suggests that the surface modification of steel by flame plasma treatment at atmospheric pressure is a proper and applicable method to improve the adhesion strength between steel and rubber.

Hot-firing Tests of Afterburning Device for a Gas Generator (가스발생기용 후연소 장치 시험 결과)

  • Kim, Mun-Ki;Lim, Byoung-Jik;Kang, Dong-Hyuk;Ahn, Kyu-Bok;Kim, Jong-Gyu;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.79-82
    • /
    • 2011
  • An afterburning device was developed to safely treat unburnt gases of fuel-rich condition discharged by a gas generator. Hot-firing tests for a subscale gas generator were carried out to investigate operation and safety of the afterburning device. When supplying additional liquid oxygen, the length of the afterburning flame was significantly reduced.

  • PDF

The Preparation of Glass Beads (Glass beads 제조에 관하여)

  • Jin Il Kim
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.3
    • /
    • pp.198-206
    • /
    • 1973
  • We produced the glass beads using a spherical vessel which is rotable with the mix ture of releasing agent and glass powder in a electric furnace (apparatus 1), a tubing apparatus of electric furnace which can be gravitated a cullet (apparatus 2) and a tubing apparatus which is dispersible glass powders with the flame of propane gas (apparatus 3). The substrates which are Korean sodium silicates glass 1, 2, boro silicates glass and lead silicates glass are used and the size of cullets is 60-300 mesh. In the results of experimental apparatus, the preferable temperature of apparatus 1 is 880$^{\circ}C$, apparatus 2 is 980$^{\circ}C$ and apparatus 3 is 1100$^{\circ}C$. However, the method of apparatus 3 is more effective than the methods of apparatus 1 and 2 in view of treating time and rate of adhesion.

  • PDF

LDV Measurement of Turbulent Flow Inside the Cylinder in an Engine (엔진 실린더내 유동 LDV측정)

  • 강건용;정동수
    • Journal of the KSME
    • /
    • v.33 no.12
    • /
    • pp.1063-1068
    • /
    • 1993
  • 왕복식엔진에서 연소과정은 실린더내 유체유동에 지배되므로 최적조건의 엔진설계를 위해서는 실린더내 유체유동을 효과적으로 이용하는 것이 필요하다. 연소과정에 중요한 영향을 미치는 압축말기 연소실내 난류강도는 흡입과정시 생성된 유동의 에너지가 압축과정을 거치면서 작은 스케일의 에디(eddy)로 깨지면서 발생된다. 연소과정시 이러한 에디들은 초기화염생성을 촉진 시키고 화염전파속도를 증진시키는 역할을 함으로써 실린더내 유체유동에 대한 이해증진을위해 실린더내 평균속도 및 난류유동을 측정하는 연구들이 많이 진행되고 있다. 엔진유동은 매사이 클의 유동이 엄밀히 주기적인 운동을 하지 않고, 각 사이클의 유동이 비정상유동을 하며, 유동의 생성 및 소멸이 매우 짧은 특성을 가진다. 따라서 산란입자가 측정체적을 통과할 때 속도데이 터가 발생하는 LDV(laser Doppler velocimetry) 측정에 있어서 레이저빔의 산란광노이즈 감소와 산란입자의 효율적인 공급으로 데이터 발생률을 높이는 것이 어려운 점이다. 이 글에서는 엔진 유동의 LDV측정시 고려해야 할 문제점들, 실험장치구성, 그리고 데이터처리 방법과 주요측정 결과에 대해 본 연구팀에서 지금까지 수행한 연구결과를 토대로 하여 기술하고자 한다.

  • PDF

Flame Formation of Ultrasonically-atomized Liquid-fuel Injected through a Slit-jet Nozzle (Slit-jet 노즐을 통해 분사되는 초음파 무화 액체연료 화염의 형성)

  • Kim, Min Sung;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 2017
  • An experimental study was performed for the combustion-field visualization of the burner which burns the liquid hydrocarbon fuel atomized by an ultrasonic oscillator. Configurations of the flame and temperature gradient were caught by both high-speed camera and thermo-graphic camera, and those images were analyzed in detail through a post-processing. In addition, the fuel consumption was measured using the balance during the combustion reaction. As a result, the consumption of atomized fuel increased with the increasing flow-rate of carrier-gas, but any correlation between the air/fuel ratio and carrier-gas flow-rate was not found at the low flow-rate condition. Also, the combustion-field grew and reaction-temperature rose due to the strengthening of combustion reaction with the increasing flow-rate of carrier-gas and power consumption of ultrasonic oscillator.

A Study on the Safety Improvement in Incineration System from the Case Study of Acrylic acid manufacturing process Accident (아크릴산 제조공정 사고사례를 통한 소각 시스템의 안전성 향상 방안)

  • Ma, Byung-Chol;Lee, Keun-Won;Im, Ji-Pyo;Kim, Young-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.52-58
    • /
    • 2012
  • Recently, waste gas incineration is increasing due to strong environmental regulatory system in Korea. These incinerating facilities are usually connected with the top of the storage tank through pipeline and incinerate off gas with the flame. Therefore, the flame originated from these facilities is likely to move back into pipeline and might cause an explosion of the storage tank. Accordingly, the purpose of this study is to suggest the preventive measures and the way to improve the safety of these incineration systems through the cause analysis of a major industrial accident occurred in a acrylic acid manufacturing process in Korea. As a result of the study, the preventive measures are suggested as follows. (1) Air or inert gas inflow facilities should be well designed to dilute flammable gases into air or inert gas sufficiently before the blower is restarted in order to prevent the explosion (2) It is needed for the detonation-type flame arresters to be installed on the top of the storage tanks. (3) In case of using the deflagration-type flame arresters, it is necessary to install a rupture disk before the arresters, or blow off the flame outside tanks by connecting the tank top and the incinerator with hood-type pipe. (4) TDR should be installed to be restarted automatically after the momentary power failure.