• Title/Summary/Keyword: 화염시험

Search Result 200, Processing Time 0.026 seconds

Fire Characteristics of Flaming and Smoldering Combustion of Wood Combustibles Considering Thickness (목재 가연물의 두께에 따른 화염연소와 훈소상태에서의 화재특성)

  • Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.67-72
    • /
    • 2015
  • A series of fire tests was conducted to examine the fire characteristics of flaming and smoldering combustion of engineered wood products, which have been widely used for furniture and finishing materials in buildings. The engineered wood products of MDF, plywood, and chipboard were ignited by a radiant cone heater with incident heat flux of $50kW/m^2$. During the fire test, key parameters representing the fire characteristics such as the heat release rate, yield rate of combustion product, and effective heat of combustion were quantified in terms of thickness. The tests show two peak points of HRRPUA due to lateral fire propagation in the initial stage, followed by later fire penetration through the specimen thickness. The mass loss rate of flaming combustion was 5 times higher than that of smoldering combustion, while the CO yield rate of smoldering combustion was 10 times higher than that of flaming combustion. This study can contribute to the understanding of fire behavior of wood combustibles and provide useful data for fire analysis.

Hydration Heat and Crack-Reducing Properties of Cement Mortar Added Fluosilicate Salt Based Hydration Heat Reducer (규불화염계 수화열 저감제가 첨가된 시멘트 모르타르의 수화열 변화 및 균열저감 특성)

  • Kim, Jin-Yong;Lee, Hyo-Song;Rhee, Young-Woo;Kim, Do-Su;Lee, Byoung-Ky;Khil, Bae-Su;Han, Seung-Gu
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.3 s.274
    • /
    • pp.198-204
    • /
    • 2005
  • Fluosilicate salts based hydration heat reducer(SWP-HR), used in this study, is composed of fluosilicate salts, soluble silica, aromatic polymer condensate and nitrate salt based inorganic compound with latent heat property. Effects of SWP-HR addition on the hydration heat and anti-crack property of cement mortar were investigated. Adiabatic hydration temperature and drying shrinkage length of SWP-HR added cement mortar had a tendency to decrease compared to those of cement mortar without SWP-HR addition. Also, it was confirmed through crack pattern experiment of plate-form specimen for elucidating crack-reducing characteristic that anti-crack property of SWP-HR added cement mortar was improved.

Effect of Powder Condition on the Fire and Explosion Characteristics of Suspended and Deposited Dusts (부유 및 퇴적의 분체 조건이 화재폭발 특성에 미치는 영향)

  • Han, Ou-Sup;Seo, Dong-Hyun;Choi, Yi-Rac;Lim, Jin-Ho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.229-236
    • /
    • 2022
  • An experimental investigation was conducted on the influences of median size, dust concentration, dust condition (cloud and layer) for the fire and explosion hazard assessment of dusts with the same powder property. For this purpose, tests have been performed in accordance with 20 L explosion sphere, thermogravi- metric analyze, combustion rate tester (UN method). We investigated the explosion characteristics and flame propagation velocity (FPV) in dust cloud and the flame spread velocity(FSV) over dust layer on 8 dust samples with different particle sizes of 4 types of dusts (Sugar, Mg, Al, Zr). An explosion hazard increased with decreasing particle size in Mg and Al dust clouds, but sugar did not show the effect of explosion hazard due to particle size change in dust clouds. The flame propagation velocity (FPV) of suspended dusts increased significantly when the particle size decreased from micro to nano than the variation of particle size in micro range. The flame spread velocity (FSV) over dust layer showed a tendency to increase over the inclined dust layers (30° slope) rather than the horizontal dust layers (0° slope). The flame spread rate (FSV) over dust layers increased on the inclined dust layer (30° slope) rather than the horizontal dust layer (0° slope) and was higher upward flame than the downward flame in condition of inclined dust layers(30° slope).

A Study on Flash Over Delay Effects on Applied Plate-Fire Spread Prevention Method at Sandwich Panels Structure (샌드위치패널 건축물 플래시오버 지연을 위한 화재확산방지플레이트 시공방법 연구)

  • Kim, Do-hyun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.79-87
    • /
    • 2017
  • Sandwich panels which are having the both sides are bonded with a heat insulating material with an iron plate are used as factories, warehouse structures as advantages of convenience in construction at economic efficiency of material cost. However, in a panel structure constructed by continuous joining of sandwich panels, a joint portion where a panel and a panel are connected is generated. The joint part is a part which is easily vulnerable to fire because flames easily flow into the melting and deformation of the iron plate during fire. The flames flowing into the panel induce diffusion of fire by rapid burning, causing damage of human life and property. In this research, we developed a flame spread prevention plate to prevent spreading of sandwich panel. This is an improvement of the workability by the anti-spreading construction method of the existing previous research, it can be applied independently to the connecting part where the panel and the panel are coupled, designed to prevent inflow and spreading of flame did. The actual fire test of the test method of KS F ISO 13784-1 of the sandwich panel specimen was conducted and the burning behavior corresponding to the presence or absence of application of the flame spread prevention plate was grasped at the panel connection part and its effect was measured. Inserting a fire spreading plate into the test result panel connecting part is measured by delaying the flashover, prevention of collapse of the specimen, and temperature rise of the opening, effectively improving the fire safety of the panel structure It was confirmed as a method that can be secured. It is judged that panel structure will contribute to ensuring fire safety by applying the fire spread prevention construction method of various methods ensuring the workability and economy of panel connection vulnerable to fire.

Improvement of Fire Resistance for Timber Framed Walls by Reinforcement of Heavy Timber Frame

  • Park, Joo-Saeng;Hwang, Kweon-Hwan;Kim, Kwang-Mo
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.6
    • /
    • pp.469-478
    • /
    • 2010
  • Fire resistance of new hybrid timber framed wall systems was evaluated in this study. These wall systems are composed of two major structural parts. One part is a heavy timber frame part designed to take charge of whole vertical load using heavy timber post and beam, and the other is an infill wall structure, designed to take charge of whole horizontal load and to provide an established level of fire resistance. A basic concept of this hybrid wall is adopted from a typical furniture structure with frame. A timber post and beam frame is constructed with Japanese Larch solid timber post(180mm by 180mm) and beam(180mm by 240mm). As infill wall systems, two types of walls are applied. One is a typical light timber framed wall with solid blocking and another is a structural insulated panel wall, in which polystyrene insulation is filled between two structural panels to make single structure. For all tested walls, two layers of 12.5mm thick type-X gypsum boards are used on fire exposed side. Prior to tests for hybrid walls, only infill walls are tested without heavy timber frame. All fire resistance tests are carried out in accordance with KS F 2257, and temperatures on several points within wall structure and unexposed wall surface are measured during fire tests. It is considered that the reinforcement of heavy timber frame is significantly efficient for improving the fire resistance of timber framed walls.

  • PDF

Comparison on the fire performance of additional insulation materials for improving the fire retardancy in engine-room of FRP vessel (FRP 선박 기관실 난연성 향상을 위한 추가 방열재의 화재성능비교)

  • Choi, Jung-Min;Um, Han-Chan;Jin, Young-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1150-1155
    • /
    • 2014
  • To prevent the flame spread in FRP vessel in fire, the engine-room of the vessel should be constructed additionally with laminated fire-retardant resin over 3 times or equivalent insulation materials to former according to the relevant standard for FRP vessel structure. It is surveyed that insulation materials called 'Gel coat' are widely used in FRP fishing vessel, however, test method and its criteria for Gel coat are not clearly establish and have not been evaluated yet, while test method and criteria for fire-retardant resin and fire-retardant polyurethane composite are described in test standard for type-approval. In this study, 3 fire-retardant resins, 4 gel coats, 1 flame-retardant paint and 1 polyurethane composite were selected based on the survey and were evaluated according to both IMO FTP Code part 5 and flame-retardant test. When comparing based on CFE values from flame-spread test, average value for 4 gel coats were lower than that of 3 fire-retardant resins. As for flame-retardant test, there were no significant differences between fire-retardant resin and gel coat, based on charred area.

Mechanical Deterioration Characteristics of ACSR due to a Flame (화염으로 인한 ACSR의 기계적 열화 특성)

  • 박창기;이광식;강지원;김영달
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.160-168
    • /
    • 2003
  • In Korea, a large portion of aerial power-transmission cables is installed in the mountains. In the case of a fire in the mountains, steel wires coated with zinc and aluminum wires of those power cables exposed to the fire or near around will be deteriorated by the blaze and the high temperature. Deterioration proceeds by interactions of a variety of factors like quality, manufacturing process, the condition of installation and exposure environment of a wire, and so on. Generally, the characteristic of a conductor affect by a forest fire can not be analyzed without the effect through simulating a forest fire. However, there are little research accomplishments of that kind of simulation about it, and there's been no analysis of a sample exposed to an actual forest fire. This thesis shows the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include the intensity of extension and wrench for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR 480[$\textrm{mm}^2$] which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

An Experimental Study on Development of a Window Sprinkler for Fire Spread Prevention along Building External Walls (건물 외벽 화재확산 방지용 윈도우 헤드의 개발을 위한 실험적 연구)

  • Kwark, Jihyun;Kim, Dong-Jun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • In case of fire in a high-rise building fire can be easily spread along the building external walls dramatically if the flame comes out through broken windows. There are a few effective methods to prevent the fire spread at the moment. One is using a fire resistance window, and the other is using a window sprinkler that discharges water to resist flame in case of fire. In this study a window sprinkler which is installed on top of windows and prevents fire by discharging water when its heat-responsive element opens was tested using a large scale furnace in accordance with the standard temperature-time graph. Test result showed that one window sprinkler was able to protect a 2,400 mm wide window from fire for 2 hours and the window backside's temperature locally increased up to $126^{\circ}C$ but kept stable around $100^{\circ}C$ for the test duration.

Method of Test for Combustion Instability and Control at Model Combustor of Supersonic Engine (초음속 엔진 모델 연소기에서의 연소불안정 및 제어 시험 기법)

  • Choi, Ho-Jin;Hwang, Yong-Seok;Jin, You-In;Park, Ik-Soo;Yoon, Hyun-Gull;Kang, Sang-Hun;Lee, Yang-Ji
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.111-115
    • /
    • 2009
  • The method of test for observing the combustion instability and controling the instability actively by using secondary injection of fuel through flame stabilizer was studied by constructing model combustor of supersonic engine. The frequency of combustion instability was detected by measuring the pressure of combustor using pressure sensor and by optical sensing of flame intensity. Electro-magnetic valve was adopted as actuator for active control and the characteristics of modulated fuel was studied by measured pressure of valve outlet and scattering signal of spray at secondary fuel injection.

  • PDF

Combustion Characteristics Based on Injector Shape of Supersonic Combustor (초음속 연소기의 인젝터 형상에 따른 연소특성)

  • Jin, Sangwook;Choi, Hojin;Lee, Hyung Ju;Byun, Jong-Ryul;Bae, Juhyun;Park, Dongchang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.3
    • /
    • pp.76-87
    • /
    • 2019
  • A direct connected test was conducted for a supersonic combustor with a cavity-type flame holder. Liquid hydro-carbon fuel was injected in different types of injectors: inclined and aeroramp injectors, for the flow condition of Mach 4 at an altitude of 20 km. The static pressure on the combustor wall along the axis and the total pressure at the exit of combustor were measured to analyze the combustion characteristics at various fuel flow rates.