Evaluation on Fire Available Safe Egress Time of Commercial Buildings based on Artificial Neural Network (인공신경망 기반 상업용 건축물의 화재 피난허용시간 평가)

  • Darkhanbat, Khaliunaa;Heo, Inwook;Choi, Seung-Ho;Kim, Jae-Hyun;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.111-120
    • /
    • 2021
  • When a fire occurs in a commercial building, the evacuation route is complicated and the direction of smoke and flame is similar to that of the egress route of occupants, resulting in many casualties. Performance-based evacuation design for buildings is essential to minimize human casualties. In order to apply the performance-based evacuation design to buildings, it requires a complex fire simulation for each building, demanding a large amount of time and manpower. In order to supplement this, it would be very useful to develop an Available Safe Egress Time (ASET) prediction model that can rationally derive the ASET without performing a fire simulation. In this study, the correlations between fire temperature with visibility and toxic gas concentration were investigated through a fire simulation on a commercial building, from which databases for the training of artificial neural networks (ANN) were created. Based on this, an ANN model that can predict the available safe egress time was developed. In order to examine whether the proposed ANN model can be applied to other commercial buildings, it was applied to another commercial building, and the proposed model was found to estimate the available safe egress time of the commercial building very accurately.

Transient Heat Transfer Analysis and Fire Test for Evaluation on Fire Resistance Performance of A60 Class Deck Penetration Piece (A60급 갑판 관통 관의 방화성능 평가를 위한 과도 열전달 해석과 화재시험)

  • Park, Woo Chang;Song, Chang Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2021
  • A60 class deck penetration piece is a fire-resistance apparatus installed on the deck compartment to protect lives and prevent flame diffusion in fire accidents. In case that the A60 piece is newly developed or its initial design is revised, it is important to verify the fire resistance performance using a fire test procedure (FTP) code. In this paper, transient heat transfer analysis was carried out to evaluate the fire resistance design compatibility of the newly devised A60 piece. The analysis results were verified via a fire test. The heat transfer characteristics were also investigated by comparing design specifications, such as diameter, internal configuration, and material type. The analysis was performed using ABAQUS/Implicit, and the fire test was performed according to the FTP code. The fire resistance performance of the A60 pieces satisfied the safety of life at sea convention regulation. The material type was the most important design specification for the A60 piece. Based on the maximum test temperature, the measured temperature of SUS316L material was 25% lower than that of S45C on average. The differences between thermal conductivity and specific heat of each material were 17% and 58%, respectively.

Study on the Shortening Effect of the Egress Travel Time Based on an Escape Scenarios by Using Shuttle Elevators for Lotte Tall Building's Evacuation Plan (초고층건물 피난계획시 피난용 엘리베이터 이용에 의한 피난소요시간의 단축효과 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.46-54
    • /
    • 2018
  • A total of 19 elevators for evacuation were installed in the Lotte World Tower and it is planned to operate the shuttle using the manual key from five refuge floors to the 1st floor in an emergency. In the event of a fire or other disaster, it is necessary to conduct intensive analysis to determine how much RSET reduction could be achieved using the evacuation elevator compared to the existing evacuation plans. When the optimal transportation sharing ratio by the evacuation elevators was 40% at the Lotte World Tower, the RSET of the evacuation scenario in parallel with the elevators in the entire building was calculated to be 1 hour and 2 minutes. The RSET of a conventional evacuation scenario (Walking along the stairs without using the elevators) was calculated to be 1 hour 29 minutes, therefore, the former evacuation scenario were found to have a shortening effect of approximately 27 minutes compared to the latter. On the other hand, to maintain this effect, each part of the evacuation route using the elevator must have the capability to protect the evacuee from any hazards caused by fires, such as smoke, flame, and radiant heat during the evacuation. Moreover, the evacuation route should be continuous from the residence position of the elevator user to the final evacuation site, and be recognized easily.

The Bacterial Colonization of Burn Wound and the Changes of Antibiotic Susceptibility in Childhood Burn (January, 1999~December, 2002) (소아 화상의 화상부위 세균 집락화와 항균제 감수성 변화(1999년 1월~2002년 12월))

  • Kim, Jin-Man;Lee, So-Yeon;Kim, Young-Ho;Shin, Eon-Woo;Oh, Phil-Soo;Kim, Kwang-Nam;Lee, Kyu-Man;Oh, Suk-Joon
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.157-165
    • /
    • 2005
  • Purpose : Children occupy a large proportion of burn victims. So we want to aid to pediatric burn care through the understanding of the bacterial distribution in burn wounds and antibiotic susceptibility against isolated microorganisms from burn wounds. Methods : We analysed the medical records of 213 pediatric burn patients(0~15 years), 406 samples that grew bacteria in burn wound sites. Results : Of the total 213 patients, male were 59.6% and female were 40.4%. Scalding burn was the most common(78.4%), flame burn was the second(16.4%). Pathogens were isolated in 406 samples. The most common was Pseudomonas aeruginosa(58.1%). Next were Enterococcus species, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus species, Acinetobacter species. P. aeruginosa was resistant to trimethoprim-sulfamethoxazole in 100%, cephalothin in 98.1%, ampicillin-sulbactam in 96.2%, ampicillin in 95.3%, ceftriaxone in 95.2%, tobramycin in 93.7%, cefoperazone in 68.9%, ceftazidime in 67.7%. Enterococcus species were resistant to tetracycline in 63.9%, streptomycin in 45.5%, gentamicin in 36.1%, penicillin G in 13.7%. S. aureus was resistant to gentamicin in 89.7%, tetracycline in 86.2%, ciprofloxacin in 86.2%, penicillin G in 84.3%, oxacillin in 78.4%, erythromycin in 76.5%. Acinetobacter species were resistant to ampicillin-sulbactam in 100%, gentamicin in 85.7%, ampicillin in 83.3%, piperacillin in 61.5%. Conclusion : P. aeruginosa was highly resistant to drugs like cefoperazone in 68.9%, ceftazidime 67.7%. S. aureus was highly resistant to penicillin G in 84.3%, oxacillin in 25.9 %, but none to vancomycin in 0%, teicoplanin in 2.2%. According to the study, Acinetobacter species turned out to be multi-resistant strains, so careful attention must be paid to the choice of antibiotics.

  • PDF

Antimicrobial Effects of Chlorine Dioxide Gas on Pathogenic Escherichia coli and Salmonella spp. Colonizing on Strawberries for Export (수출 딸기 중 이산화염소 가스 처리를 통한 병원성 Escherichia coli와 Salmonella spp. 저감화 효과)

  • Lee, Hyo-Sub;Shim, Won-Bo;An, Hyun Mi;Ha, Ji-Hyoung;Lee, Eun-Seon;Kim, Won-Il;Kim, Hwang-Yong;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.6
    • /
    • pp.451-457
    • /
    • 2016
  • The purpose of this study was to determine the antimicrobial effects of $ClO_2$ gas on pathogenic E. coli and Salmonella spp. colonizing on the fruit surface of strawberries for export. Factorial design was employed to treat strawberries inoculated with pathogenic E. coli or Salmonella spp. with a combination of $ClO_2$ gas concentrations (10, 20, 30, 40, and 50 ppmv), RH (50, 70, and 90%), and treatment time (0, 5, 10, 20, and 30 min). Interaction between the factors was observed to note that the reduced levels of microbial population were the highest when RH is set at 90% with gas concentration- and treatment time-dependent manner. With RH and gas concentration fixed at 90% and 50 ppmv, the populations of E. coli and Salmonella spp. decreased by 2.07 and 2.28 log CFU/g when treated for 20 min whereas population reduction by 0.5 and 0.7 log CFU/g were observed when treated for 5 min, respectively. The results help establish most effective conditions for $ClO_2$ gas treatment to enhance microbial safety of strawberries for export.

Four Heavenly Kings Statues of Hoeamsa in the Early Joseon Dynasty: Seen Through Clay-Fragments Excavated From the Yangju Hoeamsa Site (양주 회암사지(楊州 檜巖寺址) 4단지 문지 출토 소조편(塑造片)을 통해 본 회암사 사천왕상)

  • SHIM, Yeoungshin
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.3
    • /
    • pp.168-191
    • /
    • 2021
  • This article examines the shape, iconography, and creation date of the Four Buddhist Heavenly Kings (Sacheonwang 四天王) enshrined in the Heavenly Kings' Gate (Cheonwangmun 天王門) of Hoeamsa in Yangju, Gyeonggi Province during the early Joseon Dynasty. First, small fragments of clay decoration excavated from a fourth-platform gate site of the Hoeamsa Temple Site in Yangju Gyeonggi Province were analyzed and compared to other Four Heavenly Kings enshrined in the (Cheonwangmun gates) during the Joseon Dynasty. In addition, the size and shape of the gate were compared to other Cheonwangmun gates constructed during the Joseon Dynasty. Results revealed that the excavated fragments were part of the armor of Sacheonwang, and the clay-standing statues enshrined in the fourth-platform gate of Hoeamsa Temple would be proportional in size to those of Beopjusa Temple in Boeum, South Chungcheong Province. The flame-type pieces, which decorated the Heavenly King's crown in the Joseon Dynasty, and the rectangular-type pieces were not found in artifacts from the Goryeo Dynasty. Therefore, the Sacheonwang sculptures of the Hoeamsa Temple were likely made in the late 15th century in the early Joseon Dynasty. A detailed iconography of the Sacheonwang of Hoeamsa is presumedly based on the Buddhist paintings and illustrations of Buddhist scriptures (Gyeongbyeonsangdo 經變相圖)from the late Goryeo and early Joseon. During the late Goryeo Dynasty and early Joseon Dynasty, Traditional iconography from Goryeo and new iconography from Ming coexisted. However, in the late 15th century, the Sacheonwang statues of the early Joseon Dynasty had many different elements from those of the Goryeo Dynasty and were similar to those enshrined in Cheonwangmun Gate during the Joseon Dynasty. The Four Heavenly Kings of Hoeamsa Temple, believed to have been produced in the late 15th century, has historical significance in the following points. They were the first Joseon Sacheonwang statues example enshrined in the Cheonwangmun gate. In addition, they were established as a new tradition that influenced the iconography of the Four Heavenly Kings during the Joseon Dynasty.