• Title/Summary/Keyword: 홍채인식

Search Result 216, Processing Time 0.027 seconds

Comparative Performance Evaluations of Eye Detection algorithm (눈 검출 알고리즘에 대한 성능 비교 연구)

  • Gwon, Su-Yeong;Cho, Chul-Woo;Lee, Won-Oh;Lee, Hyeon-Chang;Park, Kang-Ryoung;Lee, Hee-Kyung;Cha, Ji-Hun
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.722-730
    • /
    • 2012
  • Recently, eye image information has been widely used for iris recognition or gaze detection in biometrics or human computer interaction. According as long distance camera-based system is increasing for user's convenience, the noises such as eyebrow, forehead and skin areas which can degrade the accuracy of eye detection are included in the captured image. And fast processing speed is also required in this system in addition to the high accuracy of eye detection. So, we compared the most widely used algorithms for eye detection such as AdaBoost eye detection algorithm, adaptive template matching+AdaBoost algorithm, CAMShift+AdaBoost algorithm and rapid eye detection method. And these methods were compared with images including light changes, naive eye and the cases wearing contact lens or eyeglasses in terms of accuracy and processing speed.

Design of a User authentication Protocol Using Face Information (얼굴정보를 이용한 사용자 인증 프로토콜 설계)

  • 지은미
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.1
    • /
    • pp.157-166
    • /
    • 2004
  • Consequently substantial research has been done on the development of the bio-metric recognition method as well as technical research in the field of authentication. As a method of bio-metric recognition, personal and unique information such as fingerprints, voice, face, Iris, hand-geometry and vein-pattern are used. The face image system in bio-metric recognition and information authentication reduces the denial response from the users because it is a non-contact system the face image system operates through a PC camera attached to a computer base this makes the system economically viable as well as user friendly. Conversely, the face image system is very sensitive to illumination, hair style and appearance and consequently creates recognition errors easily, therefore we must build a stable authentication system which is not too sensitive to changes in appearance and light. In this study, I proposed user authentication protocol to serve a confidentiality and integrity and to obtain a least Equal Error Rate to minimize the wrong authentication rate when it authenticates the user.

  • PDF

A Study of the Influence of Digital Media's Consumer Experience on Brand Equity and Purchasing Intention -Focused on Interactive Digital Media Consents using Iris Recognition Techniques (디지털 미디어를 통한 소비자 경험이 브랜드 자산 및 구매의도에 미치는 영향에 관한 연구 -홍채 인식 기술을 이용한 디지털 콘텐츠를 중심으로 -)

  • Kim, Shinyoup;Baek, Jee Hee
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.677-684
    • /
    • 2014
  • The purpose of this study, due to recent increase of digital outdoor media, is to analyze the consumer experience of interaction with digital media. Through this study it was found that experience factor consisting of cognitive, emotional, and interactional factors has a mediating effect on brand preference and brand reliability which in turn influence consumers' purchasing intention. On the other hand, it was verified that the consumer satisfaction of the experience does not directly influence purchasing intention, but only through the mediation of brand reliability. This research has implications on the academic field as well as in work-level practices, as a study based on an actual operating digital media, not a laboratory simulation that verifies the importance of digital media experience in forming brand equity through immediate influence on brand preference and brand reliability.

Gradual Certification Correspond with Sensual Confidence by Network Paths (본인인증의 네트워크 경로와 감성신뢰도에 연동한 점진적 인증방법)

  • Suh, Hyo-Joong
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.12
    • /
    • pp.955-963
    • /
    • 2017
  • Nowadays, fintech becomes the key technology of the mobile banking and payments. Financial market is moved to fintech-based non-face-to-face trade/payment from traditional face-to-face process in Korea. Core of this transition is the smartphones, which have several sensitive sensors for personal identifications such as fingerprint and iris recognition sensors. But it has some originated security risks by data path attacks, for instance, hacking and pharming. Multi-level certification and security systems are applied to avoid these threats effectively, while these protections can be cause of some inconvenience for non-face-to-face certifications and financing processes. In this paper, I confirmed that it have sensible differences correspond with the data connection paths such as WiFi networks and mobile communication networks of the smartphones, and I propose a gradual certification method which alleviates the inconvenience by risk-level definitions of the data-paths.

Method of Biological Information Analysis Based-on Object Contextual (대상객체 맥락 기반 생체정보 분석방법)

  • Kim, Kyung-jun;Kim, Ju-yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.41-43
    • /
    • 2022
  • In order to prevent and block infectious diseases caused by the recent COVID-19 pandemic, non-contact biometric information acquisition and analysis technology is attracting attention. The invasive and attached biometric information acquisition method accurately has the advantage of measuring biometric information, but has a risk of increasing contagious diseases due to the close contact. To solve these problems, the non-contact method of extracting biometric information such as human fingerprints, faces, iris, veins, voice, and signatures with automated devices is increasing in various industries as data processing speed increases and recognition accuracy increases. However, although the accuracy of the non-contact biometric data acquisition technology is improved, the non-contact method is greatly influenced by the surrounding environment of the object to be measured, which is resulting in distortion of measurement information and poor accuracy. In this paper, we propose a context-based bio-signal modeling technique for the interpretation of personalized information (image, signal, etc.) for bio-information analysis. Context-based biometric information modeling techniques present a model that considers contextual and user information in biometric information measurement in order to improve performance. The proposed model analyzes signal information based on the feature probability distribution through context-based signal analysis that can maximize the predicted value probability.

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.