• Title/Summary/Keyword: 혼합영상분리

Search Result 89, Processing Time 0.03 seconds

Study on Electrochemical Hydrogen Separation of Hydrogen and Nitrogen Mixture Gas (수소와 질소 혼합 가스의 전기화학적 수소 분리에 관한 연구)

  • DONGYUN KIM;TEAHEON KIM;DONGKEUN LEE;YOUNGSANG KIM;KOOKYOUNG AHN;YONGGYUN BAE;JINYOUNG PARK;YOUNG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.149-154
    • /
    • 2023
  • In the Fourth Industrial Revolution, hydrogen energy is in the spotlight. There is a difficulty in commercialization due to the lack of hydrogen infrastructure. Therefore, a lot of hydrogen should be imported and a method using ammonia is the most useful. In this study, using the mixed gas of hydrogen and nitrogen generated when ammonia is decomposed, the hydrogen separation performance is to be tested. Hydrogen was separated using an electrochemical hydrogen compressor based on a fuel cell and the experiment was conducted by changing the ratio of hydrogen and nitrogen. In addition, the performance was also compared by the difference both the pressure and the membrane.

Design of Fluorescence Multi-cancer Diagnostic Sensor Platform based on Microfluidics (미세 유체 기반의 형광 다중 암 진단 센서 플랫폼 설계)

  • Lee, B.K.;Khaliq, A.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.55-61
    • /
    • 2022
  • There is a major interest in diagnostic technology for multiple cancers worldwide. In order to reduce the difficulty of cancer diagnosis, a liquid biopsy technology based on a microfluidic device using trace amounts of biofluids such as blood is being studied. And optical biosensing, which measures the concentration of analytes through fluorescence imaging using biofluids, requires various strategies to improve sensitivity, and specialists and equipment are needed to carry out these strategies. This leads to an increase in diagnostic and production costs, and it is necessary to develop a technology to solve this problem. In this paper, we design and propose a fluorescent multi-cancer diagnostic sensing platform structure that implements passive self-separation technology and molecular recognition activation functions by fluid mixing, only with the geometry and microfluidic phenomena of microchannels based on self-driven flow by capillary force. In order to check the parameters affecting the performance of the plasma separation part of the designed sensor, the hydrodynamic diameter of the channel and the viscosity of the fluid were set as variables to confirm the formation of plasma separation flow through simulation. And finally, we propose an optimal sensor platform structure.

Synthesis of d- and l-Form of $^{99m}Tc$-HMPAO, and Comparison of Brain Uptake ($^{99m}Tc$-HMPAO의 광학이성체 d-, l-Form의 합성과 뇌섭취율 비교)

  • Kang, Chan-Soon;Chang, Young-Soo;Jeong, Jae-Min;Lee, Dong-Soo;Chung, June-Key;Lee, Kang-Choon;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.69-74
    • /
    • 2001
  • Purpose: $^{99m}Tc$-HMPAO is a radiopharmaceutical for imaging cerebral blood flow. HMPAO (RR, SS)-4.8-diaza-3,6,6,9-tetramethylundecan-2,10- dione bisoxime) has three stereoismers such as, meso-. d-, and l-HMPAO. Techentium complexes of meso-HMPAO and d,l-HMPAO are known to have different in vivo brain uptakes. In this study, enantiomers of HMPAO (d-HMPAO and l-HMPAO) were separated from d,l-HMPAO. These enantiomers were labeled with $^{99m}Tc$ and the biodistribution studies were performed in mice. Materials and Methods: An intermediate imine product was produced from 2,3-butanedione monooxime and 2,2-dimethyl-1,3-propanediamine (54% yield) and was reduced into a mixture of three isomers (35% yield). The meso-isomer was separated from d,l-mixture by repeated fractional crystallization (11 % yield). The d- and l-enantiomers were subsequently separated by co-crystallization with optical isomers of tartaric acid (25% and 5% yield. respectively). Each enantiomeric HMPAO was labeled with $^{99m}Tc$ by reacting with $SnCI_2{\cdot}2H_2O\;and\;^{99m}Tc$-pertechnetate. Biodistribution study was performed 1 hr after tail vein injection to ICR mice. Results: Radiochemical purities of each compound were over 80%. In biodistribution study. the brain uptakes of d,l- d- and l-form were 1.34, 1.12 and 1.67% ID/g, respectively. In case of l-lsomer the brain uptake was higher (1.5 fold) than d-isomer. Conclusion: We successfully purified each enantiomeric HMPAO. In biodistribution study of stereoismers of $^{99m}Tc$-HMPAO in mice, l-HMPAO may show better brain image than d,l-HMPAO which was supplied in a commercial kit.

  • PDF

Design of a Distributed Mixer Using Dual-Gate MESFET's (Dual-Gate MESFET를 이용한 분포형 주파수 혼합기의 설계)

  • Oh, Yang-Hyun;An, Jeong-Sig;Kim, Han-Suk;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.2 no.1 s.2
    • /
    • pp.15-23
    • /
    • 1998
  • In this paper, distributed mixer is studied at microwave frequency. The circuit of distributed mixer composed of gate 1,2, drain transmission lines, matching circuits in input and output terminal, DGFET's. For impedance matching of input and output port at higher frequency, image impedance concept is introduced. In distributed mixer, a DGFET's impedances are absorbed by artificial transmission line, this type of mixer can get a very broadband characteristics compared to that of current systems. A RF/LO signal is applied to each gate input port, and are excited the drain transmission line through transcondutance of the DGFET's. The output signals from each drain port of DGFET's added in same phases. We designed and frabricated the distributed mixer, and a conversion gain, noise figure, bandwidth, LO/RF isolation of the mixer are shown through computer simulation and experimentation.

  • PDF

Real Time Abandoned and Removed Objects Detection System (실시간 방치 및 제거 객체 검출 시스템)

  • Jeong, Cheol-Jun;Ahn, Tae-Ki;Park, Jong-Hwa;Park, Goo-Man
    • Journal of Broadcast Engineering
    • /
    • v.16 no.3
    • /
    • pp.462-470
    • /
    • 2011
  • We proposed a realtime object tracking system that detects the abandoned or disappeared objects. Because these events are caused by human, we used the tracking based algorithm. After the background subtraction by Gaussian mixture model, the shadow removal is applied for accurate object detection. The static object is classified as either of abandoned objects or disappeared object. We assigned monitoring time to the static object to overcome a situation that it is being overlapped by other object. We obtained more accurate detection by using region growing method. We implemented our algorithm by DSP processor and obtained an excellent result throughout the experiment.

Loitering Behavior Detection Using Shadow Removal and Chromaticity Histogram Matching (그림자 제거와 색도 히스토그램 비교를 이용한 배회행위 검출)

  • Park, Eun-Soo;Lee, Hyung-Ho;Yun, Myoung-Kyu;Kim, Min-Gyu;Kwak, Jong-Hoon;Kim, Hak-Il
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.6
    • /
    • pp.171-181
    • /
    • 2011
  • Proposed in this paper is the intelligent video surveillance system to effectively detect multiple loitering objects even that disappear from the out of camera's field of view and later return to a target zone. After the background and foreground are segmented using Gaussian mixture model and shadows are removed, the objects returning to the target zone is recognized using the chromaticity histogram and the duration of loitering is preserved. For more accurate measurement of the loitering behavior, the camera calibration is also applied to map the image plane to the real-world ground. Hence, the loitering behavior can be detected by considering the time duration of the object's existence in the real-world space. The experiment was performed using loitering video and all of the loitering behaviors are accurately detected.

Development of Quantification Methods for the Myocardial Blood Flow Using Ensemble Independent Component Analysis for Dynamic $H_2^{15}O$ PET (동적 $H_2^{15}O$ PET에서 앙상블 독립성분분석법을 이용한 심근 혈류 정량화 방법 개발)

  • Lee, Byeong-Il;Lee, Jae-Sung;Lee, Dong-Soo;Kang, Won-Jun;Lee, Jong-Jin;Kim, Soo-Jin;Choi, Seung-Jin;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.486-491
    • /
    • 2004
  • Purpose: factor analysis and independent component analysis (ICA) has been used for handling dynamic image sequences. Theoretical advantages of a newly suggested ICA method, ensemble ICA, leaded us to consider applying this method to the analysis of dynamic myocardial $H_2^{15}O$ PET data. In this study, we quantified patients' blood flow using the ensemble ICA method. Materials and Methods: Twenty subjects underwent $H_2^{15}O$ PET scans using ECAT EXACT 47 scanner and myocardial perfusion SPECT using Vertex scanner. After transmission scanning, dynamic emission scans were initiated simultaneously with the injection of $555{\sim}740$ MBq $H_2^{15}O$. Hidden independent components can be extracted from the observed mixed data (PET image) by means of ICA algorithms. Ensemble learning is a variational Bayesian method that provides an analytical approximation to the parameter posterior using a tractable distribution. Variational approximation forms a lower bound on the ensemble likelihood and the maximization of the lower bound is achieved through minimizing the Kullback-Leibler divergence between the true posterior and the variational posterior. In this study, posterior pdf was approximated by a rectified Gaussian distribution to incorporate non-negativity constraint, which is suitable to dynamic images in nuclear medicine. Blood flow was measured in 9 regions - apex, four areas in mid wall, and four areas in base wall. Myocardial perfusion SPECT score and angiography results were compared with the regional blood flow. Results: Major cardiac components were separated successfully by the ensemble ICA method and blood flow could be estimated in 15 among 20 patients. Mean myocardial blood flow was $1.2{\pm}0.40$ ml/min/g in rest, $1.85{\pm}1.12$ ml/min/g in stress state. Blood flow values obtained by an operator in two different occasion were highly correlated (r=0.99). In myocardium component image, the image contrast between left ventricle and myocardium was 1:2.7 in average. Perfusion reserve was significantly different between the regions with and without stenosis detected by the coronary angiography (P<0.01). In 66 segment with stenosis confirmed by angiography, the segments with reversible perfusion decrease in perfusion SPECT showed lower perfusion reserve values in $H_2^{15}O$ PET. Conclusions: Myocardial blood flow could be estimated using an ICA method with ensemble learning. We suggest that the ensemble ICA incorporating non-negative constraint is a feasible method to handle dynamic image sequence obtained by the nuclear medicine techniques.

Analysis of fMRI Signal Using Independent Component Analysis (Independent Component Analysis를 이용한 fMRI신호 분석)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.188-195
    • /
    • 1999
  • The fMRI signals are composed of many various signals. It is very difficult to find the accurate parameter for the model of fMRI signal containing only neural activity, though we may estimating the signal patterns by the modeling of several signal components. Besides the nose by the physiologic motion, the motion of object and noise of MR instruments make it more difficult to analyze signals of fMRI. Therefore, it is not easy to select an accurate reference data that can accurately reflect neural activity, and the method of an analysis of various signal patterns containing the information of neural activity is an issue of the post-processing methods for fMRI. In the present study, fMRI data was analyzed with the Independent Component Analysis(ICA) method that doesn't need a priori-knowledge or reference data. ICA can be more effective over the analytic method using cross-correlation analysis and can separate the signal patterns of the signals with delayed response or motion related components. The Principal component Analysis (PCA) threshold, wavelet spatial filtering and analysis of a part of whole images can be used for the reduction of the freedom of data before ICA analysis, and these preceding analyses may be useful for a more effective analysis. As a result, ICA method will be effective for the degree of freedom of the data.

  • PDF

Application of Precipitate Flotation Technique to Separative Preconcentration and Determination of Arsenic in Water Samples (물시료 중 비소의 분리 정량을 위한 침전 부선기술의 응용)

  • Park Sang-Wan;Choi Hee-Seon;Kim Young-Man;Kim Young-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.389-396
    • /
    • 1991
  • The pre-concentration and determination of ultratrace arsenic in water samples was studied by the precipitate flotation technique. The arsenic in 1.0l of water sample, in which all suspended materials were filtered out, was coprecipitated together with La(OH)$_3$ precipitates at pH 8.5${\pm}$0.1. After the precipitate was made to be hydrophobic by adding mixed surfactant of 1 : 8 mole ratio of sodium oleate and sodium dodecyl sulfate, it was floated with the aid of tiny bubbles of nitrogen gas in a flotation cell. The floated precipitate was quantitatively collected on a micropore glass filter by the suction, dissolved with small volume of 1.0M sulfuric acid, and accurately diluted to 25.00ml with a de-ionized water. Total arsenic was spectrophotometrically determinated by forming silver diethyldithiocarbamate complex of arsine generated from arsenic in the concentrated solution. The calibration curve was linear up to 20ng/ml in the original solution. Analytical results showed that contents of arsenic in a campus wastewater and a river water were 8.2ng/ml and l.0ng/ml, respectively, and their recoveries were 93${\%}$ and 90${\%}$ in water samples which a given amount of arsenic was added into. From above result, it could be concluded that this method was applicable to the determination of arsenic in various kinds of water at low ng/ml levels.

  • PDF

Laver(Kim) Thickness Measurement and Control System Design (해태(김)두께측정 및 조절 장치 설계)

  • Lee, Bae-Kyu;Choi, Young-Il;Kim, Jung-Hwa
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.226-233
    • /
    • 2013
  • In this study, In Laver's automatic drying device, laver thickness measurement and control devices that are associated with. Disconnect the water and steam, after put a certain amount of the mixture(water and laver) in the mold. In process, Laver of the size and thickness (weight) to determine, constant light source to detect and image LED Lamp occur Vision Sensor (Camera) prepare, then the values of these state of the image is transmitted in real time embedded computers. Built-in measurement and control with the purpose of the application of each of the channels separately provided measurements are displayed on a monitor, And servo signals sent to each of the channels and it become so set function should be. In this paper, the laver drying device, prior to the laver thickness measurement and control devices that rely on the experience of existing workers directly laver manually adjust the thickness of the lever, but the lever by each channel relative to the actuator by installing was to improve the quality. In addition, The effect of productivity gains and labor savings are.