• Title/Summary/Keyword: 호흡 알코올 농도

Search Result 9, Processing Time 0.025 seconds

Changes in Visual Acuity and Values of Objective Refraction with Breath Alcohol Concentration (호흡 알코올 농도에 따른 시력과 타각적 굴절검사 값의 변화)

  • Jung, Su A;Nam, Soo-Kyung;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.187-193
    • /
    • 2015
  • Purpose: This study was aimed to investigate effects of increased breath alcohol concentration (BrAC) which is the standard measurement of alcohol consumption in sobriety test under current laws on visual acuity and values of objective refraction. Methods: For twenty three males in 20s (average age $21.17{\pm}2.19$ years, body mass index (BMI) $22.09{\pm}2.16$) were selected. Distance and near visual test was performed at BrAC of 0%, 0.05% and 0.08%, and objective refraction with open-field auto-refractometer was also performed at different BrAC. Results: As breath alcohol concentration is increased, distance visual acuity was decreased, which was statistically significant, but near visual acuity was not changed. Also, values of objective refraction tended to be increased towards minus as breath alcohol concentration is increased. Conclusions: As breath alcohol concentration is increased, corrected visual acuity is decreased and refractive power is towards minus, it is necessary that visual acuity test and refraction measurement should be conducted under sober condition.

A Study on the Change of Contrast Sensitivity with Breath Alcohol Concentration in Various Luminance (다양한 휘도에서 호흡 알코올 농도에 따른 대비감도 변화 연구)

  • Nam, Soo-Kyung;Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.505-511
    • /
    • 2014
  • Purpose: This study was to investigate the effect of breath alcohol concentration (BrAC) increase with drinking alcohol on contrast sensitivity in the conditions of restricted BrAC. Methods: 23 males in 20s (average age $21.17{\pm}2.19$ years, body mass index (BMI) $22.09{\pm}2.16$) were selected and administered the amount of alcohol to reach 0.05% and 0.08% BrAC calculated by BAC (blood alcohol concentration) Dosing Software program, which was developed as basis of Watson's formula. Then, the contrast sensitivity in various luminance conditions (photopic, mesopic, and mesopic with glare) was measured and compared between these conditions. Results: The contrast sensitivity in all spatial frequency was decreased with BrAC increase. Although BrAC was increased, the peak of contrast sensitivity didn't change as 6 cycle per degree (cpd) in the photopic condition and 3 cpd in the mesopic condition, respectively. But, in the mesopic condition with glare, the peak of contrast sensitivity was shifted from 6 cpd at 0% and 0.05% BrAC to 3 cpd at 0.08% BrAC with increase of alcohol concentration. Conclusions: The increase of BrAC by drinking alcohol induces the decrease of contrast sensitivity in all spatial frequency and the shift of peak of contrast sensitivity, which can cause safety accidents, and may have an effect on various visual tasks.

The Effects of Breath Alcohol Concentration Increase on Visual Field and Readable Visual Field (호흡 알코올 농도 증가가 시야 및 가독시야에 미치는 영향)

  • Jung, Su A;Nam, Soo-Kyung;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.153-158
    • /
    • 2016
  • Purpose: This study was aimed to investigate effects of breath alcohol concentration (BrAC) increase on visual field and readable visual field. Methods: 23 males in 20s (average age $21.17{\pm}2.19years$, body mass index (BMI) $22.09{\pm}2.16$) were selected and administered the amount of alcohol to reach 0.05% and 0.08% BrAC calculated by BAC (blood alcohol concentration) Dosing Software program. Then, visual field and readable visual field test with Vision Disk were conducted. Results: Visual field are measured as $74.41{\pm}15.97^{\circ}$, $64.98{\pm}17.93^{\circ}$, and $58.33{\pm}19.01^{\circ}$ (p=0.000) and readable visual field as $21.93{\pm}12.71^{\circ}$, $17.41{\pm}11.36^{\circ}$, $14.26{\pm}9.93^{\circ}$ (p=0.006) in 0.00%, 0.05% and 0.08% BrAC respectively. As breath alcohol concentration increased, both visual field and readable visual field decreased. Conclusions: BrAC increase with drinking could be the cause of safety accident by decreasing visual field and readable visual field, it is necessary to raise awareness.

Analysis about the reliability of sobriety testing (focused on the Blood-Breath Ratios) (음주 측정의 신뢰도에 대한 분석 (혈액호흡 분배비율을 중심으로))

  • Lee, Won-Young;Ko, Myoung-Soo
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.6
    • /
    • pp.49-60
    • /
    • 2008
  • The aim of this study was to evaluate the variability of the blood.breath ratio (BBR) value and to rationalize the determination of ethanol in breath for evidential sobriety testing. In the experiment forty eight healthy persons, 24 men and 24 women, took part. The experiment included the experimental condition such as sex(2),the type of alcoholic beverage(2; soju, whisky), the type of food(2;kimchi stew, pork belly) and the amount of ethanol consumed(2; 0.35g/kg, 0.70g/kg, based on body weight ) according to 24 factorial design by orthogonal arrays. Breath and blood sample were taken each 8 times and 5 times after the end of drinking. The blood and breath alcohol measurements were highly correlated (r = 0.973). The Results of four way analyses of variance revealed a significant 'the type of food' effect for maximum BrAC (F (1, 43) =5.1, pp<.029), but no significant effect in the type of alcoholic beverage and sex. The overall blood/breath ratio (${\pm}$ SD) was 2295${\pm}$403 and the 95% confidence interval were 1489 and 3101. In spite of these variations, at this time, it seems to be reasonable that apply 2100:1 conversion factor to breathalyzers, because most of the subjects showed the blood.breath ratio of over 2100:1 at least 30 minutes or more passed from the time of drinking as shown in this study.

Relationship between Blood Alcohol Concentrations and Breath Alcohol Concentrations of Healthy Korean Males (혈중 알코올 농도와 호흡기 알코올 농도 상관성: 한국인 남성)

  • Yi, SeungHwan;Nam, BeomWoo;Seo, JeongSeok
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.4
    • /
    • pp.9-15
    • /
    • 2015
  • The relationship between BAC(Blood Alcohol Concentrations) and BrACs(Breath Alcohol Concentrations) and also partition ratio of healthy Korean adult males (96 males) are researched in this paper and its dependency is described according to TBW (total body water), BMI (body mass index), BFM (body fat mass), and PBF (percentage of body fat). Among the above four variables, TBW affects significantly to the partition ratio compared to the other variables. The partition ratio of Korean healthy males showed 1,913 (95 % Confidence Interval (C.I.) from 1,889 to 1,937) for the whole time intervals. However, when Q was averaged after 60 minutes later, its values was 2,011 (95 % C.I. from 1,982 to 2,040). Bland-Altman plots showed the compatibility of measurement methods of multi-gas analyzer, and the biases according to the partition ratios (Q=2,100 and Q=1,913) gave -0.0052 % (95 % CI from -0.0059 to -0.0045%) and -0.0004 % (95 % CI from -0.0011 to +0.0003%), respectively.

Anatophysiological Changes Related to Myopization Induced by Alcohol Ingestion on Eyes (알코올 섭취 후 발생한 근시화와 관련된 눈의 해부생리학적 변화)

  • Lee, Jung-Ouk;Moon, Byeong-Yeon;Cho, Hyun-Gug
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.890-893
    • /
    • 2010
  • 알코올 섭취 후 발생하는 해부생리학적 변화가 눈의 일시적인 근시화에 미치는 영향을 알아보고자 하였다. 평균 24.5${\pm}$1.5세의 남자 8명(16 안)을 대상으로 0.42 g/kg의 알코올을 30분 간에 걸쳐 섭취토록 한 다음, 알코올 섭취 1시간, 4시간, 24시간 후의 교정굴절력, 각막곡률반경과 두께, 동공직경, 안압, 그리고 안구축의 길이변화를 측정하여 알코올 섭취 전과 비교하였다. 알코올 섭취 1시간 후에 알코올 섭취 전과 비교하여 호흡 중 알코올 농도가 가장 높았고(p<0.001), 교정굴절력의 구면 (-)굴절력 증가(p<0.05), 동공 크기의 감소(p<0.05), 안압의 하강(p<0.001), 그리고 안구축의 길이 증가가 나타났다. 알코올 섭취 4시간 후에도 모든 측정값들이 섭취 1시간 후와 동일한 경향이었다. 그러나 알코올 섭취 24시간 후에는 알코올 섭취 전과 비교하여 의의있는 변화를 보이지 않았다. 알코올 섭취로 인한 일시적인 근시화는 안압하강과 안구축의 길이변화와 관련성이 있을 것으로 판단된다.

  • PDF

The Changes of The Eye and a Correlation Depending on Watching a Smartphone and taking in Alcohol (스마트폰 시청과 알코올 섭취에 따른 눈의 변화와 상관관계)

  • Lee, Jeong-Yun;Yun, Eon-Jeong;Kim, Sung-Min;Hwang, Hye-Kyung;Park, Gyeung-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.473-479
    • /
    • 2013
  • Purpose: This article tried to find the changes of the eye and a correlation depending on watching a smartphone and taking in alcohol. Methods: This paper conducted the refraction inspection, the radius of corneal curvature, tonometry and the corneal thickness measurement and analysis for 31 persons (18 males and 13 females) who have healthy drinking habit, not having the medical history of taking medicine related with disorders of the eye, a mental disease, systemic disease and alcohol metabolism. Results: Of respirations depending on watching a smartphone, the alcohol concentration was significantly decreased in 15 minutes, 30 minutes, 45 minutes, 60 minutes and the convalescent stage. (p<0.01, p<0.001) As the result of comparing the refraction inspection after and before watching a smartphone when drinking alcohol, there was a significant difference in the cylindrical power and the axis. (p=0.005, p=0.001) The change of intraocular pressure depending on watching a smartphone after drinking alcohol was decreased significantly from 30 minutes (p<0.001), and watching a smartphone didn't have any significant effect on the corneal thickness depending on the elapsed time from when drinking alcohol. Conclusions: Watching a smartphone and taking in alcohol had a significant effect on the cylindrical power and the axis. Watching a smartphone and taking in alcohol which may cause the visual function-strain are the factors that need to consider before the refraction inspection.

Relationship of Refractive and Anatomical Changes on Eyes after Alcohol Ingestion (알코올 섭취에 의한 눈의 굴절변화와 해부학적 변화와의 관계)

  • Kim, Jung-Ouk;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • Purpose: This study was to investigate the relevance between refractive and anatomical changes temporarily on the eyes after alcohol ingestion. Methods: Eight subjects (16 eyes) which were $24.5{\pm}1.5$ aged males drunk the alcohol of 0.42 g per kg of body weight within 30 minutes. Refractive errors, the radius of corneal curvature, corneal thickness, pupillary size, intraocular pressure, and the length of the ocular axis at 1 h, 4 h, and 24 h after alcohol ingestion were compared with them of non-alcoholic state. Results: At 1 h after alcohol ingestion, breath alcohol concentration was the highest (p<0.001), more negative spherical power was needed (p<0.05) for correction, pupillary diameter was decreased (p<0.05), intraocular pressure was decreased (p<0.001), and the length of the ocular axis was increased compared with each one of non-alcoholic state. At 4 h after alcohol ingestion, all anatomical changes were the same tendency as at 1 h after alcohol ingestion. But at 24 h after alcohol ingestion, both refractive changes and anatomical changes were not significant compared with them of non-alcoholic state. Conclusions: Temporary changes of refractive error after alcohol ingestion may be related with decrease of intraocular pressure and increase of the length of ocular axis.

Effects of Film Treatment on Sprouting Ability and Growth Properties of Ginseng Seedlings (묘삼의 필름포장 처리가 저온저장 중 생장과 품질에 미치는 영향)

  • Eun Ha Chang;Ji-Weon Choi;Ji Hyun Lee;Sooyeon Lim;Haejo Yang;Il Sheob Shin
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.08a
    • /
    • pp.81-81
    • /
    • 2020
  • 본 연구는 새싹인삼(Panax ginseng sprout) 재배용으로 이용하기 위한 묘삼(종삼)의 장기 저온저장 시 사용되는 필름의 종류가 묘삼의 출아율이나 생육에 영향을 미치는 지 조사하기 위해 수행되었다. 포장에 사용된 필름은 다공성물질인 제올라이트와 페그마타이트가 5% 함유된 50㎛ low density polyethylene(기능성 LDPE) 필름과 nylon/polyethylene 80 ㎛(Ny/PE) 필름에 묘삼을 100g씩 포장한 후 골판지 상자에 담아 -2℃의 저장고에서 10개월 동안 저장하면서 8개월째부터 2개월마다 시료를 꺼내어 5℃에서 5일 동안 온도 순화를 시킨 후 1차 조사에서는 육안조사로 실험실에서 건전한 묘삼과 부패 묘삼을 조사하였고, 건전한 묘삼만 새싹인삼 수경재배 농가에 재식한 후 2차 조사로 묘삼의 출아율과 출아된 묘삼이 새싹인삼으로 건전하게 생육한 비율을 조사하였다. 조사결과 Ny/PE 필름에 8개월 저장된 묘삼의 경우 1차 육안검사 시 뇌두부위가 검게 변하여 묘삼이 대부분 고사된 것으로 조사되었다. 필름 개봉 전 필름 내부의 O2 및 CO2 가스농도를 측정한 결과 O2 농도는 1.91%, CO2 농도는 38.9%로 측정되었고, 필름 개봉 시 알코올 냄새의 이취가 나는 것으로 보아 Ny/PE 필름으로 포장 된 묘삼이 -2℃의 저온저장기간 동안에도 호흡을 하면서 필름 내 산소를 완전히 소모하고 혐기적인 환경으로 변화시켜 대사활동이 불가능하였기 때문에 뇌두의 싹이 고사된 것으로 조사되었다. 반면 기능성 필름으로 포장한 묘삼은 저장 8개월에 정식 후 74.3%의 출아율을 보였고, 건전한 새싹인삼의 비율은 67.2%로 조사되었다. 정식 전·후 묘삼의 개체수 대비 건전 출아율의 비율은 56.7%를 나타내어 Ny/PE 필름으로 포장한 묘삼의 결과와 큰 차이를 보였다. 기능성필름의 개봉 전 필름 내부의 O2 및 CO2 가스농도를 측정한 결과 O2 농도는 12.9%, CO2 농도는 4.6%로 측정되어 묘삼의 저온저장 시 필름을 적용할 경우 공기의 유동이 원활이 이루어져 내부 O2 농도를 일정 수준 이상 유지해주는 필름을 사용하는 것이 묘삼의 출아와 생육에 좋은 것으로 조사되었다.

  • PDF