• Title/Summary/Keyword: 호흡대역

Search Result 20, Processing Time 0.024 seconds

THE NITROUS OXIDE CONCENTRATION IN BREATHING ZONE ACCORDING TO SCAVENGING METHODS DURING DEEP SEDATION OF PEDIATRIC DENTAL PATIENTS (소아치과 환자의 깊은 진정시 호기가스 제거 방법에 따른 호흡대역에서 Nitrous Oxide 농도 변화)

  • Lee, Chung-Won;Yoon, Hyung-Bae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.124-131
    • /
    • 2003
  • The concentration of nitrous oxide in dental environment has increased especially in pediatric department. In pediatric department frequently met the behavior disordered patients who need the deep sedation. As the deeply sedated patients could not respond well to verbal command, the amount of mouth breathing would be increased especially with mouth prop which backward transposition of mandible. Inhalation of low concentration of nitrous oxide for a long duration has caused various side effects such as spontaneous abortion and inhibition of methionine synthetase activity which is harmful to DNA synthesis. For evaluation of factors of mouth breathing during deep sedation. The author measured the concentration of nitrous oxide in breathing zone by the change of the scavenging methods. One is drain the gas through the tail part of reservoir bag of Jackson Ree's system naturally. Another is scavenge from tail portion of reservoir bag with negative pressure. Last one is scavenge from nasal mask with negative pressure. The nitrous oxide concentration in breathing zone was the lowest in nasal part drainage but high above the recommended concentration of NIOSH. The order of nitrous concentration in breathing zone was: natural drainage, tail part with negative pressure, nasal part with negative pressure. This would reflect the order of resistance of nasal airway and showed the amount of mouth breathing. From the above experiment, the resistance of nasal airway by the increment of gas flow in corrugating tube and reservoir bag would be one of the causative factors of mouth breathing in deeply sedated patients.

  • PDF

Noncontact Respiration and Heartbeat Monitoring System using the Doppler Radar System (2.4GHz 도플러 레이더를 이용한 비접촉 방식의 심박 및 호흡 모니터링 시스템)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Kyoung-Joung
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.478-479
    • /
    • 2008
  • 본 연구에서는 비접촉 방식으로 심박과 호흡을 측정하기 위해 2.4GHz 대역에서 동작하는 도플러 레이더 센서와 베이스밴드 모듈로 구성된 도플러 레이더 시스템을 설계하고 그 성능을 평가하였다. 설계된 도플러 레이더 시스템은 심폐활동에 의한 흉부 표면의 움직임에 의해 반사되는 레이더의 위상변화를 이용하여 심폐 활동을 측정한다. 도플러 레이더 센서의 출력은 베이스 밴드 모듈의 전처리 필터부, 증폭부, 오프셋 조정부를 통과하여 호흡과 심박 신호로 분리된다. 분리된 생체신호는 기존의 생체신호와 상관성을 확인하기 위해 기준신호로 호흡과 심전도를 동시에 측정하여 그 결과를 비교 및 분석하였다. 설계된 도플러 레이더 시스템에서 분리된 호흡 및 심박 신호는 측정 대상의 움직임이 없는 상태에서는 높은 검출률을 보였으며, 도플러 레이더에서 심박과 호흡 신호를 검출한 결과 거리, 호흡과 심박의 변이량, 호흡과 심박대역에 따라 검출률이 영향을 받는다는 것을 알 수 있었다.

  • PDF

Development of Respiration Detection Technique for the Human Body Using Doppler Radar Principle (도플러 레이다 원리를 이용한 인체 호흡수 측정기술 개발에 관한 연구)

  • 김기남;김인석
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.315-318
    • /
    • 2002
  • 본 논문은 도플러 레이다의 원리를 이용하여 인체 호흡수 측정기술에 관하여 기술하였다. 주파수 1.59㎓ 대역의 전자파를 이용한 인체 호흡수 측정의 역사적 배경과 함께 자세한 측정원리 및 방법을 제시하였다. 인체의 흉곽 운동에 의해 반사된 신호의 도플러 주파수 차이만큼의 변이량을 오실로스코프 상에서 단위시간 당 호흡수를 나타내었다. 헤테로다인 방식의 시스템으로 측정하였으며, 폴디드 슬롯 안테나를 자체 제작하여 사용하였다. 이와 같은 인체 호흡수 측정기는 생명체 탐지 장치나 수면 무호흡증 측정기로 사용될 수 있으며 동작 감지 레벨을 높이면 그 적용 범위는 더욱더 늘어날 것으로 예상된다.

  • PDF

A Study of Noncontact Heartbeat and Respiration Detection Using the Doppler Radar (도플러 레이더를 이용한 비접촉 방식의 심박 및 호흡 검출에 관한 연구)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • In this paper, a 2.4 GHz doppler radar system consisting of a doppler radar sensor and a baseband module were designed to detect heart beat and respiration signal without direct skin contact. The doppler radar system emits RF signal of 2.4 GHz toward human chest, and then detects phase modulation of the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from I/Q channels of the doppler radar system are applied to the pre-processing circuit, the amplification circuit, and the offset circuit of the baseband module. The designed system was tested on mouse, rabbit and mankind, which have different range of heart rates and respiration signals, to evaluate detection accuracy of the system. ECG acquisition system and respiration transducer were used to generate the reference signal. In our experiments, a performance of detection were found to be high in the case that the subject stays still. In this paper, we confirmed that non-contact heart beat and respiration detection using the doppler radar has the possibility and limitation according to distance, cardiopulmonary activities, range of heart rates and respiration.

Apnea Detection and Respiration Rate Estimation Using IR-UWB Radar Signals (IR-UWB 레이다 기반의 무호흡 검출 및 호흡수 측정)

  • Ko, Inchang;Park, Hyung Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.10
    • /
    • pp.802-809
    • /
    • 2017
  • This paper presents a novel apnea detection and respiration rate estimation method using impulse-radio ultra-wideband (IR-UWB) radar. The proposed method utilizes amplitude, time of arrival, and power in the selected band. The experimental results show that respiration rate can be estimated accurately using proposed method. And, it is shown that the selectivity between apnea and respiration can be improved more than 50 dB using the proposed method.

EEG Study for the Effects of Mouth Breathing on Brain Functions (구강 호흡이 뇌기능에 미치는 영향에 관한 EEG 연구)

  • Lee, Kyung-Jin;Lee, Song-Yi;Park, So-Young;Jang, So-Ra;Kang, Chang-Ki
    • Science of Emotion and Sensibility
    • /
    • v.19 no.4
    • /
    • pp.119-126
    • /
    • 2016
  • In this study, we investigated the effects of mouth breathing on brain activity through electroencephalogram (EEG). EEG was performed on 12 healthy volunteers of age ranging from 21 to 27 years (male: female = 6:6, non-smoker). Brain waves on resting state (Rest_N/Rest_M) and auditory-language stimuli state (Eng_N/Eng_M) were recorded during mouth and nose breathing. Four different regions (R1~R4) were classified based on the brain functionality. And each channel (e.g., Pf1 and Pf2) and frequency (${\alpha}$, ${\beta}$, ${\gamma}$, and ${\theta}$) were analyzed using their absolute power ratios of fast Fourier transform (FFT). The results showed that there was no significant difference between Rest_N and Rest_M. Eng_N had significantly higher brain activity than Rest_N; on the other hand, there was no significant difference between Rest_M and Eng_M. These results demonstrate that mouth-breathing on resting state does not induce any significant effects on brain activity and/or functionality, even though it causes subtle temporary inconvenience. In addition to the uncomfort, the brain activity can be adversely influenced by mouth-breathing, which could lower the cognitive skills under certain circumstances.

Respiration and Heartbeat detection algorithm using UWB radar (UWB 레이더를 사용한 호흡 및 심박 감지 알고리즘)

  • Le, Minhhuy;Hwang, Lan-mi;Fedotov, Dmitry
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.70-76
    • /
    • 2019
  • Ultra Wideband (UWB) Radar is a high-resolution radar for short distance detection which uses signals transmitted and received by each antennas in order to detect a target. It is possible to detect the respiration and heartbeat of a person without contact It is getting more and more often utilized since it is not affected by physical environment. In this paper, we implement an algorithm to detect human respiration and heartbeat rate using UWB radar signal. We process radar signals reflected from human body using Median filter, Kalman filter, Band Pass filter and so on. We also use CZT to extract breathing and heart rate. ECG (Electrocardiogram) was used for comparison of heartbeat data and we confirm that each data of ECG and UWB Radar were more than 98% identical each other.

Emotion Recognition Method Using Heart-Respiration Connectivity (심장과 호흡의 연결성을 이용한 감성인식 방법)

  • Lee, Dong Won;Park, Sangin;Whang, Mincheol
    • Science of Emotion and Sensibility
    • /
    • v.20 no.3
    • /
    • pp.61-70
    • /
    • 2017
  • Physiological responses have been measured to recognize emotion. Although physiological responses have been interrelated between organs, their connectivities have been less considered for emotion recognizing. The connectivities have been assumed to enhance emotion recognition. Specially, autonomic nervous system is physiologically modulated by the interrelated functioning. Therefore, this study has been tried to analyze connectivities between heart and respiration and to find the significantly connected variables for emotion recognition. The eighteen subjects(10 male, age $24.72{\pm}2.47$) participated in the experiment. The participants were asked to listen to predetermined sound stimuli (arousal, relaxation, negative, positive) for evoking emotion. The bio-signals of heart and respiration were measured according to sound stimuli. HRV (heart rate variability) and BRV (breathing rate variability) spectrum were obtained from spectrum analysis of ECG (electrocardiogram) and RSP (respiration). The synchronization of HRV and BRV spectrum was analyzed according to each emotion. Statistical significance of relationship between them was tested by one-way ANOVA. There were significant relation of synchronization between HRV and BRV spectrum (synchronization of HF: F(3, 68) = 3.605, p = 0.018, ${\eta}^2_p=0.1372$, synchronization of LF: F(3, 68) = 5.075, p = 0.003, ${\eta}^2_p=0.1823$). HF difference of synchronization between ECG and RSP has been able to classify arousal from relaxation (p = 0.008, d = 1.4274) and LF's has negative from positive (p = 0.002, d = 1.7377). Therefore, it was confirmed that the heart and respiration to recognize the dimensional emotion by connectivity.

The implementation of modular respiratory system for patient monitoring (환자감시를 위한 모듈형 호흡 시스템의 구현)

  • 박종억;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.503-506
    • /
    • 2001
  • There are four factors for patient monitoring : electrocardiography, blood pressure, temperature and respiration. While there are a lot of studies of E.C.C (electro-cardiography) monitoring system in the world, the studies of Respiratory system are not enough and leave much to be desired in the country. In this paper, we developed a respiratory system with the electrical impedance change of the lungs depending on the breath. Using the same electrode, we can monitor E.C.C and Respiration simultaneously, so we can monitor a patient's no-breathing state due to the central nerve paralysis in the emergency room easily. In this monitoring system, the analog part was made separated from the digital part for reducing power source noise and protecting patient from electric shock. The analog part consists of the several parts a high-frequency sine-wave generator, all amplifier for amplifying any impedance change signal, an analog processing part for rectifying and filtering. And the digital parts consists of three parts an AD convertor for converting analog signal to digital signal, digital filter, and a digital part for digital signal processing. This system's merits are using the same electrode with E.C.C and developing the multiple patient monitoring system easily.

  • PDF

Non-Contact Vital Signal Sensor Based on Impedance Variation of Resonator (공진기의 임피던스 변화에 근거한 비접촉 생체 신호 센서)

  • Kim, Kee-Yun;Kim, Sang-Gyu;Hong, Yunseog;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.813-821
    • /
    • 2013
  • In this paper, a vital signal sensor based on impedance variation of resonator is presented. Proposed vital signal sensor can detect the vital signal, such as respiration and heart-beat signal. System is composed of resonator, oscillator, surface acoustic wave (SAW) filter, and power detector. The cyclical movement of a dielectric such as a human body, causes the impedance variation of resonator within the near-field range. So oscillator's oscillation frequency variation is effected on resonator's resonant frequency. SAW filter's skirt characteristic of frequency response can be transformed a small amount of frequency deviation to a large variation. Aim to enhance the existing sensor detection range, proposed sensor operates in 870 MHz ISM band, and detect respiration and heart-beat signal at distance of 120 mm.