• 제목/요약/키워드: 호명

검색결과 184건 처리시간 0.022초

고체 질소를 이용한 극저온 냉동의 해석 및 실험 (Analysis and Experiment on Cryogenic Refrigeration Using Solid Nitrogen)

  • 변정주;이윤숙;장호명
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.77-83
    • /
    • 2001
  • The thermal characteristics of solid nitrogen are investigated by experiment and analysis for the purpose of evaluating its feasibility as a cooling medium for HTS (high T$_{c}$ superconductor) magnets. A cryostat to refrigerate a liquid-nitrogen container well below its freezing temperature with a 2-stage GM cryocooler is designed and constructed. The spatial distribution of temperature is measure as a function of time during the freezing and melting processes. from which the thermal diffusivity of solid nitrogen can be approximately calculated. the freezing process is formulated and solved by the integral method with an assumption of phase equilibrium at the solid-liquid interface and experimental observation. It may be concluded that the thermal diffusion in solid phase is much slower than in liquid and the degree of super-saturation is quite severe in the solidification of nitrogen.n.

  • PDF

전도냉각형 저온용기에서 중간냉각의 최적화 (Optimization of intermediate cooling in conduction-cooled cryostat)

  • 장호명;박정수;김성래;김형진;진홍범;이봉근
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.155-158
    • /
    • 2001
  • An intermediate cooling is indispensible to reduce the refrigeration power at superconducting system that is cooled conductively by a cryocooler without liquid cryogens. The cooling load at the intermediate stage is caused by the mechanical supports, the radiation shield and the current lead. From the cooling load calculation, a thermodynamic analysis that take into account the temperature-dependent properties of the materials and the actual performance of the cryocooler is developed. For any given physical dimensions of the various components, it is shown that there exist a unique optimum for the intermediate temperature to minimize the overall refrigeration power. The results of this study can be usefully applied to the selection of the cryocooler as well as the design of the conduction-cooled cryostat.

  • PDF

2단 GM냉동기를 이용한 수소액화 시스템의 운전조건 (Operating Conditions of Hydrogen Liquefaction Systems using Two-Stage GM Refrigerator)

  • 박대종;장호명;강병하
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.194-197
    • /
    • 1999
  • Thermodynamic cycle analysis has been performed to maximize the liquid amount for two hydrogen liquefaction systems using two-stage GM(Gifford-McMahon) refrigerator. the optimal operating conditions have been analytically sought with real properties of normal hydrogen for the two-stage GM direct contact system and the two-stage GM precooled L-H (Linde-Hampson) system. In the precooled system, there existed optimal values for compressed mass flow and compressed pressure to maximize the liquefied mass. It was recommended to use a cryocooler, which had a large precooling capacity between 70 and 100K.

  • PDF

고집적화된 1TC SONOS 플래시 메모리에 관한 연구 (A study on the High Integrated 1TC SONOS Flash Memory)

  • 김주연;이상배;한태현;안호명;서광열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.26-31
    • /
    • 2002
  • To realize a high integrated Flash memory utilizing SONOS memory devices, the NOR type 1TC(one Transistor Cell) SONOS Flash arrays are fabricated and characterized. This SONOS Flash arrays with common source lines are designed and fabricated by conventional 0.35$\mu\textrm{m}$ CMOS process. The thickness of ONO for memory cell is tunnel oxide of 34${\AA}$, nitride of 73${\AA}$ and blocking oxide of 34${\AA}$. To investigate operating characteristics, CHEI(Channel Hot Electron Injection) method and Bit line erase method are selected as the write operation and the erase method, respectively. The disturbance characteristics according to the write/erase/read cycling are also examined. The degradation characteristics are investigated and then the reliability of SONOS flash memory is guaranteed.

  • PDF

2 단계 펄스 주입을 이용한 프로그램 방법에서 백바이어스 효과 (Back bias effects in the programming using two-step pulse injection)

  • 안호명;장영걸;김희동;서유정;김태근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.258-258
    • /
    • 2010
  • In this work, back bias effects in the program of the silicon-oxide-nitride-oxide-silicon (SONOS) cell using two-step pulse sequence, are investigated. Two-step pulse sequence is composed of the forward biases for collecting the electrons at the substrate terminal and back bias for injecting the hot electrons into the nitride layer. With an aid of the back bias for electron injection, we obtain a program time as short as 600 ns and an ultra low-voltage operation with a substrate voltage of -3 V.

  • PDF

도계장 도계의 Campylobacter 균 오염에 관한 연구 (Studies on Campylobacter jejuni and Campylobacter coli contamination on broiler carcasses in slaughterhouse)

  • 나호명;고바라다;박성도;김용환
    • 한국동물위생학회지
    • /
    • 제30권1호
    • /
    • pp.77-84
    • /
    • 2007
  • The present study was carried out to investigate the incidence of Campylobacter spp. from the chicken carcasses in slaughterhouse. A total of 9 strains were primarily isolated from enrichment culture and selective culture of the sample with candle and microaerophilic chamber method. Nine of Gram-negative, catalase-positive and oxidase-positive strains were further isolated by the determination of biochemical characteristics and finally identified as Campylobacter jejuni with HIP 400F and HIP l134R primers. Therefore, this PCR method proved to be useful as a routine diagnostic test for the Campylobacter detection and confirmation of C. jejuni and C. coli in naturally contaminated poultry samples.

상용 극저온 냉동기를 예냉기로 채택한 수소액화 시스템의 성능 해석 (Performance Analysis of a Hydrogen Liquefaction System using Commercial Cryogenic Refrigerators for Precooling)

  • 김승현;장호명;강병하
    • 한국수소및신에너지학회논문집
    • /
    • 제9권2호
    • /
    • pp.53-64
    • /
    • 1998
  • Thermal analysis on a Linde-Hampson hydrogen liquefaction system using cryogenic refrigerators as precooling has been carried out. Three commercially available models of cryogenic refrigerators, such as CTI l020CP, CVI CGR009 and CVI CGR011, are considered in the performance analysis. The effect of ortho-para conversion process during hydrogen liquefaction is also studied in detail. The results obtained indicate that the optimal hydrogen mass flow rate and the optimal compressed pressure exist for the maximum hydrogen liquefaction rate. The optimal compressed pressure is increased in the range of 80 - 120 bar with an increase in the hydrogen mass flow rate. It is also found that better performance could be obtained with a cryogenic refrigerator, which produces high cooling capacity at precooling temperature in the range of 80 - 100 K.

  • PDF

2단 냉동기의 냉각시간 단축을 위한 기체-간극 열스위치 설계 (Design of gas-gap thermal switch for reducing cooldown time of 2-stage cryocooler)

  • 김형진;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2000
  • A preliminary design of gas-gp thermal switch is presented to reduce the cooldown time of superconducting system conduction-cooled by a two-stage refrigerator without liquid cryogens. The switch connects thermally the first and the second stages (ON) to take advantage of the larger refrigeration capacity at the first stage during the beginning period. After the cryogenic temperature is reached, the switch should isolate thermally the two stages (OFF) in order to reduce the heat leak to the cold end. In this paper, a new concept for the performance index is introduced to evaluate the reduction of the cooldown time and the increase of the cooling load at the same time. In addition, the design of a gas-gap switch is discussed as a closed container of several staggered concentric tubes filled with gas, which is frozen at low temperatures for the shut-off of heat without any mechanical actuation. Some of the detailed features in the design is quantitative investigated by the gas convection model in the continuum or the rarefied gas region.

  • PDF

마이크로파 응용을 위한 Interdigital capacitor의 간단한 모델 (Simple model of interdigital capacitors for microwave applications)

  • 유희욱;이명식;김동호;안호명;고중혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.198-199
    • /
    • 2005
  • Conformal mapping based models are given for interdigital capacitors on substrates with a thin superstrate and covering dielectric thin film. This model is useful for a wide range of dielectric constant and layer thickness. Interdigital capacitors with finger numbers n>3 are discussed.

  • PDF

SONOS two-bit 메모리의 측면확산에 영향을 주는 programming 조건 연구 (A study on the programming conditions suppressing the lateral diffusion of charges for the SONOS two-bit memory)

  • 이명식;안호명;서광열;고중혁;김병철;김주연
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.117-120
    • /
    • 2005
  • The SONOS devices have been fabricated by the conventional $0.35{\mu}m$ complementary metal-oxide-semiconductor (CMOS) process with NOR array. Two-bit operation using conventional process achieve the high density memory compare with other two-bit memory. Lateral diffusion phenomenon in the two-bit operation cause soft error in the memory. In this study, the programming conditions arc investigated in order to reduce lateral diffusion for two-bit operation of CSL-NOR type SONOS flash cell.

  • PDF