• Title/Summary/Keyword: 형광 X-선

Search Result 212, Processing Time 0.04 seconds

A Study on Iron Compounds of Volcanic Basalt at Hantan Riverside in Cheorwon (철원 한탄강유역 현무암의 철 화합물에 관한 연구)

  • Yoon, In Seop;Kim, Sun Bae
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.169-173
    • /
    • 2015
  • Fe compounds of volcanic basalt samples distributed at the Hantan riverside in Cheorwon were investigated by means of X-ray diffractometry (XRD), X-ray fluorescence spectroscopy (XRF) and $M{\ddot{o}}ssbauer$ spectroscopy. We found that samples were typical basic rock which consisted of augite, anorthite, albite and sanidine etc. They had the total amount of iron compounds including hematite (${\alpha}-Fe_2O_3$) varies from 6.20 w% to 12.8 w% depending on the different regions by XRF. The $M{\ddot{o}}ssbauer$ spectra of the samples were consisted of three doublets. The balance state of Fe ions of all samples were chiefly $Fe^{2+}$, and $Fe^{2+}/Fe^{3+}$ ratios were 2.27~3.42.

Characterization of Iron Oxides in Soils of Cheju Island by Mössbauer Spectroscopy and Chemical Techniques (Mössbauer 분광법(分光法)과 선택적(選擇的) 추출방법(抽出方法)에 의한 제주도(濟州道) 토양(土壤)에서의 산화철(酸化鐵)의 특성(特性) 구명(究明))

  • Kang, Dong-Woo;Kim, Doo-Chul;Ko, Jeong-Dae;Hong, Sung-Rak;Song, Kwan-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.1
    • /
    • pp.3-15
    • /
    • 1997
  • Iron oxide compounds in 8 selected Cheju Island soil samples have been analized by X-ray fluorescence spectrometer(XRF), X-ray diffractometry(XRD), selected chemical techniques, and $M{\ddot{o}}ssbauer$ spectroscopy. The result of this analysis by XRF shows that the rate of quantity of $Fe_2O_3$ in 8 soil samples was from 8.03wt.%(Daejeong paddy soil) to 18.21wt.%(Songag soils). Songag, Heugag and Gueom soils were detected to have lower peaks of intensity of hematite by XRD. In addition, these soils were not detected to have hematite and goethite peaks. Ferrihydrite, which is a short-range-order mineral commonly present in volcanic ash soil, was not detected by XRD due to low concentration and/or poor cristallinity. Ferrihydrite contents estimated from Feo values were 8.8~35.2g/kg for volcanic ash soils and 0.85g/kg for the Daejeong soil. Most of the soil samples represented by the paramagnetic $Fe^{3+}$ doublet obtained from $M{\ddot{o}}ssbauer$ spectra at room temperature and 18K were considered to arise from the presence of ferrihydrite, superparamagnetic goethite, and silicate minerals. Also the paramagnetic $Fe^{2+}$ doublets are attributable to primary minerals such as olivine, illite, chlorite, augite, biotite, and hornblende. Goethite and hematite were identified as the dominant crystalline iron oxides in these soils from $M{\ddot{o}}ssbauer$ spectra obtained at room temperature and 18K. All the soil samples exhibited strong superparamagnetic relaxation. Collapse of the $M{\ddot{o}}ssbauer$ magnetic hyperfine splitting at room temperature was due to the small size(${\sim}180{\AA}$) of the oxide particles and/or Al-subsituted goethite.

  • PDF

A Study of Physicochemical Characteristics and Adsorption properties of Cs and Sr of Natural Zeolite from Kuryongpo in Korea (한국 구룡포산 천연 제올라이트의 이화학적 특성 및 Cs과 Sr 흡착 특성 연구)

  • Bayarsaikhan Battsetseg;Hu Sik Kim;Hyeon Uk Choo;Jong Sam Park;Woo Taik Lim
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.2
    • /
    • pp.117-124
    • /
    • 2023
  • X-ray diffraction analysis, X-ray fluorescence analysis, thermal differential and thermos gravimetric analysis, cation exchange capacity analysis, and Cesium (Cs), Strontium (Sr) adsorption experiments were performed to investigate the physical and chemical properties of natural zeolite from Guryongpo in Korea. As a result of X-ray diffraction analysis, minerals such as mordenite, heulandite, clinoptilolite, and illite are contained, and as a result of X-ray fluorescence analysis, elements such as SiO2, Al2O3, CaO, K2O, MgO, Fe2O3 and Na2O are contained, and the cation exchange capacity was 148.6 meq/100 g. As a result of thermal differential and thermos gravimetric analysis, it was confirmed that the thermal stability was excellent up to 600 ℃. As a result of the adsorption equilibrium experiment over time, the equilibrium was reached within 30 min. for Cesium (Cs) and within 8 hr. for Strontium (Sr), and the adsorption rates of Cesium (Cs) and Strontium (Sr) were 80% and 18%, respectively. As a result of the single-component isothermal adsorption experiment, in conformed to the Langmuir model, and the maximum Cesium (Cs) adsorption amount was 131.5 mg/g, which was high, while the Strontium (Sr) maximum adsorption amount was 29.5 mg/g, which was low. In the case of the natural zeolite used in this study, the content of minerals including 8-rings such as clinoptilolite, heulandite, and mordenite is high, showing high selectivity for Cesium (Cs).

Scientific Analysis of Gilt-Bronze Plaquettes with Buddhist Images(Panbul) from Anapji Pond, Gyeongju (안압지 금동판불의 과학적 분석)

  • Yu, Heisun;Park, Haksoo;Shin, Yongbi
    • Conservation Science in Museum
    • /
    • v.8
    • /
    • pp.49-69
    • /
    • 2007
  • This is about the scientific analysis of the 10 items of the gilt-bronze Panbul excavated from Anapji, Gyeongju. First, the composition of the Panbul was confirmed, using X-ray fluorescence spectrometer (XRF), and the patinas covering the surface of the Panbul were analyzed, using X-ray diffractometer (XRD). And the micro structures and gilt layer of the Panbul were investigated, using microscope and scanning electron microscope with energy dispersive spectrometer (SEM/EDS), and in order to investigate the internal conditions of the Panbul, X-radiography was conducted. As the result, it is found out that the material of the Panbul excavated from Anapji was the bronze of copper (86~95%) and tin (4~12%), and coated with gold. And cuprite (Cu2O) was detected from red patina of the gilt-bronze Panbul, and chalcocite(Cu2S) also was detected from the black patina. As the result of the observation of the micro structure through microscope, it is estimated that it was manufactured, using the wax molding method, and, judging from the fact that the thickness of gilt layer was not even, and that the groove had been filled, it was presumed that the amalgam coating method had been used, but some questions still remain, because mercury was not detected. Lastly, through the X-radiography, it was observed that the tiny round spots existed, which was presumed to have been generated during the casting.

Development of TLD Algorithms by Monochromatic Fluorescence Radiations and Continuous Spectrum X-rays (단일에너지 형광 X선 및 연속 스펙트럼 X선장에 의한 TLD 알고리즘 개발)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.159-174
    • /
    • 1998
  • Personal dosimetry system is required to measure the personal dose equivalent accurately in a wide range of radiation fields, but the dose evaluation algorithms have been developed with the X-ray fields described in MOST Ordinance (equivalent to the ANSI N13.11) from which the actual fields to be monitored may be significantly different. To evaluate the dose more accurately when workers are exposed to the non-ANSI N13.11 radiation fields, two algorithms for monochromatic radiations (one algorithm was used for various ratios of TL dosimeter and the other for matrix approximation) were developed with the experimental data of the energy responses of the $CaSO_4:Dy$ TL materials irradiated by monochromatic X-ray fields recently established in KAERI, and compared with the another algorithm developed on the basis of the ANSI N13.11 continuous spectrum X-ray fields. Then it follows the discussions for some results of the algorithm testing including mixed fields irradiations and angular response conducted in IAEA/RCA intercomparison as well as ANSI and ISO continuous spectrum X-ray and monochromatic radiation fields. The developed algorithms were successfully performed the test not only in the continuous spectrum X-ray fields given by MOST Ordinance but also in the several non-MOST Ordinance radiation fields which could be encountered in the practical working environments.

  • PDF

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Synthesis of long afterglow phosphor SrAl2O4 : Eu+2,Dy+3 by skull melting method (스컬용융법에 의한 SrAl2O4 : Eu+2,Dy+3 축광성 형광체 합성)

  • Ryu, Chang-Min;Seok, Jeong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.1
    • /
    • pp.42-46
    • /
    • 2017
  • $SrAl_2O_4$ : $Eu^{2+}$,$Dy^{3+}$ phosphorescent phosphors were synthesized by skull melting method. The molar ratio of oxides in the phosphors synthesized by the skull melting technique was $SrCO_3$ : $Al(OH)_3$ : $Eu_2O_3$ : $Dy_2O_3$= 1 : 2 : 0.015 : 0.02. Crystal structure and surface morphology were investigated by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. Optical properties of the synthesized $SrAl_2O_4$ : $Eu^{2+}$,$Dy^{3+}$ were measured by photoluminescence (PL) spectrometer for in-depth study on the excitation, emission and afterglow properties. From the PL measurements, it was found that excitation occurred in the wavelength range from 300 to 420 nm with peak position at 360 nm. The emission spectrum showed a broad curve in the wavelength from 450 to 600 nm with peak position at 530 nm. $SrAl_2O_4$ : $Eu^{2+}$,$Dy^{3+}$ phosphors exhibited afterglow properties with emission that lasted for a long period.

The Role of Acid in the Synthesis of Red-Emitting Carbon Dots (장파장 형광 탄소 양자점 제조에 있어서 산의 역할에 대한 연구)

  • Yun, Sohee;Lee, Jinhee;Choi, Jin-sil
    • Applied Chemistry for Engineering
    • /
    • v.33 no.3
    • /
    • pp.309-314
    • /
    • 2022
  • Carbon dots (CDs) are few nanometer-sized carbon-based nanoparticles and emerging candidate materials in various fields such as biosensors and bioimaging due to their excellent optical properties and high biocompatibility. However, most CDs, emitting blue light, have limited their application in biomedical fields due to the low penetration of short-wavelength lights into the biological system. Therefore, there has been enormous need to develop long-wavelength emitting CDs. In this study, red-emitting CDs were successfully synthesized through the hydrothermal reaction of p-phenylenediamine with hydrochloric acid. In addition, the effect of the amount of hydrochloric acid on the formation of carbon dots, resulting in the variation of the chemical structures of CDs, were investigated, which was confirmed with the intensive structural analyses using infrared and X-ray photoelectron spectroscopy. It was found that the chemical structure of CDs governed their optical properties and quantum yield. Therefore, this study provides an insight into the role of acid in forming red-emitting CDs as the optimal probe for biomedical application.

Photoluminescence Characteristics of the ZnGa2O4 Phosphor Thin Films as a Function of Post-annealing Temperature (후열처리 온도에 따른 ZnGa2O4 형광체 박막의 발광 특성)

  • Yi, Soung-Soo;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.60-65
    • /
    • 2002
  • $ZnGa_2O_4$ thin film phosphors have been deposited using a pulsed laser deposition method on Si(100) substrates at a substrate temperature of $550^{\circ}C$ with oxygen pressures of 100mTorr, and subsequently to investigate their photoluminescence characteristics after post-annealed at $600^{\circ}C$ and $700^{\circ}C$. As a result for X-ray diffraction, $Ga_2O_3$ shape appeared with increasing annealing temperature. The luminescent spectra show a broad band extending from 350 to 600nm peaking at 460nm. A post-annealing treatment of $ZnGa_2O_4$ thin films led to the different shape of luminescent intensity and grain size.