Fe compounds of volcanic basalt samples distributed at the Hantan riverside in Cheorwon were investigated by means of X-ray diffractometry (XRD), X-ray fluorescence spectroscopy (XRF) and $M{\ddot{o}}ssbauer$ spectroscopy. We found that samples were typical basic rock which consisted of augite, anorthite, albite and sanidine etc. They had the total amount of iron compounds including hematite (${\alpha}-Fe_2O_3$) varies from 6.20 w% to 12.8 w% depending on the different regions by XRF. The $M{\ddot{o}}ssbauer$ spectra of the samples were consisted of three doublets. The balance state of Fe ions of all samples were chiefly $Fe^{2+}$, and $Fe^{2+}/Fe^{3+}$ ratios were 2.27~3.42.
Iron oxide compounds in 8 selected Cheju Island soil samples have been analized by X-ray fluorescence spectrometer(XRF), X-ray diffractometry(XRD), selected chemical techniques, and $M{\ddot{o}}ssbauer$ spectroscopy. The result of this analysis by XRF shows that the rate of quantity of $Fe_2O_3$ in 8 soil samples was from 8.03wt.%(Daejeong paddy soil) to 18.21wt.%(Songag soils). Songag, Heugag and Gueom soils were detected to have lower peaks of intensity of hematite by XRD. In addition, these soils were not detected to have hematite and goethite peaks. Ferrihydrite, which is a short-range-order mineral commonly present in volcanic ash soil, was not detected by XRD due to low concentration and/or poor cristallinity. Ferrihydrite contents estimated from Feo values were 8.8~35.2g/kg for volcanic ash soils and 0.85g/kg for the Daejeong soil. Most of the soil samples represented by the paramagnetic $Fe^{3+}$ doublet obtained from $M{\ddot{o}}ssbauer$ spectra at room temperature and 18K were considered to arise from the presence of ferrihydrite, superparamagnetic goethite, and silicate minerals. Also the paramagnetic $Fe^{2+}$ doublets are attributable to primary minerals such as olivine, illite, chlorite, augite, biotite, and hornblende. Goethite and hematite were identified as the dominant crystalline iron oxides in these soils from $M{\ddot{o}}ssbauer$ spectra obtained at room temperature and 18K. All the soil samples exhibited strong superparamagnetic relaxation. Collapse of the $M{\ddot{o}}ssbauer$ magnetic hyperfine splitting at room temperature was due to the small size(${\sim}180{\AA}$) of the oxide particles and/or Al-subsituted goethite.
Bayarsaikhan Battsetseg;Hu Sik Kim;Hyeon Uk Choo;Jong Sam Park;Woo Taik Lim
Korean Journal of Mineralogy and Petrology
/
v.36
no.2
/
pp.117-124
/
2023
X-ray diffraction analysis, X-ray fluorescence analysis, thermal differential and thermos gravimetric analysis, cation exchange capacity analysis, and Cesium (Cs), Strontium (Sr) adsorption experiments were performed to investigate the physical and chemical properties of natural zeolite from Guryongpo in Korea. As a result of X-ray diffraction analysis, minerals such as mordenite, heulandite, clinoptilolite, and illite are contained, and as a result of X-ray fluorescence analysis, elements such as SiO2, Al2O3, CaO, K2O, MgO, Fe2O3 and Na2O are contained, and the cation exchange capacity was 148.6 meq/100 g. As a result of thermal differential and thermos gravimetric analysis, it was confirmed that the thermal stability was excellent up to 600 ℃. As a result of the adsorption equilibrium experiment over time, the equilibrium was reached within 30 min. for Cesium (Cs) and within 8 hr. for Strontium (Sr), and the adsorption rates of Cesium (Cs) and Strontium (Sr) were 80% and 18%, respectively. As a result of the single-component isothermal adsorption experiment, in conformed to the Langmuir model, and the maximum Cesium (Cs) adsorption amount was 131.5 mg/g, which was high, while the Strontium (Sr) maximum adsorption amount was 29.5 mg/g, which was low. In the case of the natural zeolite used in this study, the content of minerals including 8-rings such as clinoptilolite, heulandite, and mordenite is high, showing high selectivity for Cesium (Cs).
This is about the scientific analysis of the 10 items of the gilt-bronze Panbul excavated from Anapji, Gyeongju. First, the composition of the Panbul was confirmed, using X-ray fluorescence spectrometer (XRF), and the patinas covering the surface of the Panbul were analyzed, using X-ray diffractometer (XRD). And the micro structures and gilt layer of the Panbul were investigated, using microscope and scanning electron microscope with energy dispersive spectrometer (SEM/EDS), and in order to investigate the internal conditions of the Panbul, X-radiography was conducted. As the result, it is found out that the material of the Panbul excavated from Anapji was the bronze of copper (86~95%) and tin (4~12%), and coated with gold. And cuprite (Cu2O) was detected from red patina of the gilt-bronze Panbul, and chalcocite(Cu2S) also was detected from the black patina. As the result of the observation of the micro structure through microscope, it is estimated that it was manufactured, using the wax molding method, and, judging from the fact that the thickness of gilt layer was not even, and that the groove had been filled, it was presumed that the amalgam coating method had been used, but some questions still remain, because mercury was not detected. Lastly, through the X-radiography, it was observed that the tiny round spots existed, which was presumed to have been generated during the casting.
Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jai-Ki
Journal of Radiation Protection and Research
/
v.23
no.3
/
pp.159-174
/
1998
Personal dosimetry system is required to measure the personal dose equivalent accurately in a wide range of radiation fields, but the dose evaluation algorithms have been developed with the X-ray fields described in MOST Ordinance (equivalent to the ANSI N13.11) from which the actual fields to be monitored may be significantly different. To evaluate the dose more accurately when workers are exposed to the non-ANSI N13.11 radiation fields, two algorithms for monochromatic radiations (one algorithm was used for various ratios of TL dosimeter and the other for matrix approximation) were developed with the experimental data of the energy responses of the $CaSO_4:Dy$ TL materials irradiated by monochromatic X-ray fields recently established in KAERI, and compared with the another algorithm developed on the basis of the ANSI N13.11 continuous spectrum X-ray fields. Then it follows the discussions for some results of the algorithm testing including mixed fields irradiations and angular response conducted in IAEA/RCA intercomparison as well as ANSI and ISO continuous spectrum X-ray and monochromatic radiation fields. The developed algorithms were successfully performed the test not only in the continuous spectrum X-ray fields given by MOST Ordinance but also in the several non-MOST Ordinance radiation fields which could be encountered in the practical working environments.
The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.
The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.
Journal of the Korean Crystal Growth and Crystal Technology
/
v.27
no.1
/
pp.42-46
/
2017
$SrAl_2O_4$ : $Eu^{2+}$,$Dy^{3+}$ phosphorescent phosphors were synthesized by skull melting method. The molar ratio of oxides in the phosphors synthesized by the skull melting technique was $SrCO_3$ : $Al(OH)_3$ : $Eu_2O_3$ : $Dy_2O_3$= 1 : 2 : 0.015 : 0.02. Crystal structure and surface morphology were investigated by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. Optical properties of the synthesized $SrAl_2O_4$ : $Eu^{2+}$,$Dy^{3+}$ were measured by photoluminescence (PL) spectrometer for in-depth study on the excitation, emission and afterglow properties. From the PL measurements, it was found that excitation occurred in the wavelength range from 300 to 420 nm with peak position at 360 nm. The emission spectrum showed a broad curve in the wavelength from 450 to 600 nm with peak position at 530 nm. $SrAl_2O_4$ : $Eu^{2+}$,$Dy^{3+}$ phosphors exhibited afterglow properties with emission that lasted for a long period.
Carbon dots (CDs) are few nanometer-sized carbon-based nanoparticles and emerging candidate materials in various fields such as biosensors and bioimaging due to their excellent optical properties and high biocompatibility. However, most CDs, emitting blue light, have limited their application in biomedical fields due to the low penetration of short-wavelength lights into the biological system. Therefore, there has been enormous need to develop long-wavelength emitting CDs. In this study, red-emitting CDs were successfully synthesized through the hydrothermal reaction of p-phenylenediamine with hydrochloric acid. In addition, the effect of the amount of hydrochloric acid on the formation of carbon dots, resulting in the variation of the chemical structures of CDs, were investigated, which was confirmed with the intensive structural analyses using infrared and X-ray photoelectron spectroscopy. It was found that the chemical structure of CDs governed their optical properties and quantum yield. Therefore, this study provides an insight into the role of acid in forming red-emitting CDs as the optimal probe for biomedical application.
$ZnGa_2O_4$ thin film phosphors have been deposited using a pulsed laser deposition method on Si(100) substrates at a substrate temperature of $550^{\circ}C$ with oxygen pressures of 100mTorr, and subsequently to investigate their photoluminescence characteristics after post-annealed at $600^{\circ}C$ and $700^{\circ}C$. As a result for X-ray diffraction, $Ga_2O_3$ shape appeared with increasing annealing temperature. The luminescent spectra show a broad band extending from 350 to 600nm peaking at 460nm. A post-annealing treatment of $ZnGa_2O_4$ thin films led to the different shape of luminescent intensity and grain size.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.