• Title/Summary/Keyword: 형광 X-선

Search Result 212, Processing Time 0.027 seconds

X-Ray Spectrometric Determination of $Ta_2O_5,\;Nb_2O_5$ and $ZrO_2$in Tin-Slag Samples by Double Dilution Technique (주석-슬랙중 $Ta_2O_5,\;Nb_2O_5$$ZrO_2$의 이중희석법을 이용한 X-선 분광분석)

  • Young-Sang Kim;Kee-Chae Park
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.302-308
    • /
    • 1984
  • X-ray spectrometric determination of $Ta_2O_54, $Nb_2O_5$ and $ZrO_2$ in tin-slag samples using the double dilution technique was conducted. Tin-slag samples and one synthesized standard sample having similar composition to the samples were diluted with anhydrous $Li_2B_4O_7$ at the level of 1.00, 2.00 and 3.00% of the sample content, respectively. The diluted samples were fused at $1,150^{\circ}C$ for 30 minutes, and these glass beads were finely ground and pelletized. With the X-ray intensities measured, analytical results were calculated by the double dilution equation. The results agreed to the reference values obtained by the standard calibration method and the simple dilution technique within allowable error range and were reproducible.

  • PDF

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF

Evaluation of Depth Dose and Surface Dose According to Treatment Room Wall Distance (방사선 치료실 벽면 거리에 따른 심부선량과 표층선량 평가)

  • Je, Jae-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.121-125
    • /
    • 2011
  • This study was intended to evaluate the surface dose and depth dose of according to the distance of the treatment room wall. High energy photon beams from linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. The scattered radiation measured by thermoluminescence dosimeter(TLD). Linear accelerators rotation center of the four walls(X) distance was measured to be 236, 272, 303, and 337 cm. The result of 100 cGy and 200 cGy of 6 MV photon irradiation, surface dose was 0.49, 0.83 mSv at 236 cm of the shortest distance to the wall, In 272 cm 0.41, 0.53 mSv, 303 cm in the 0.28, 0.57 mSv, and 337 cm distance from the wall in the 0.33, 0.76 mSv surface dose respectively. There was remarkable difference in the surface dose among the treatment room wall distance. The results of useful data in relation to stochastic effect for radiation therapy patients.

사파이어 기판에 증착한 MgMoO4:Eu3+ 박막의 광학 특성

  • Gang, Dong-Gyun;Kim, Jin-Dae;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.185.1-185.1
    • /
    • 2015
  • 본 연구에서는 라디오파 마그네트론 스퍼터링 방법을 사용하여 증착 온도를 변화시켜면서 Eu 이온이 도핑된 MgMoO4 적색 형광체 박막을 사파이어 기판 상부에 성장하였다. 타겟은 고상반응법을 사용하여 직접 제작하였다. 형광체 박막의 구조, 표면, 광학적 특성은 X-선 회절장치, 주사전자현미경, 투과도 및 광여기발광 측정장치를 사용하여 측정하였다, 증착 온도는 100, 200, 300, $400^{\circ}C$이었으며, 증착 후 $870^{\circ}C$에서 열처리 공정을 실행하였다. 이와 더불어, $400^{\circ}C$에서 증착한 박막을 다양한 온도 $770-920^{\circ}C$에서 열처리를 수행하여 각각의 특성을 분석하였다. 증착 온도 $200^{\circ}C$에서 성장한 박막의 경우에 614 nm에 피크를 갖는 주 적색 발광 피크가 관측되었으며, 열처리 온도를 달리한 박막의 경우에는 $920^{\circ}C$에서 가장 강한 발광 피크가 나타났다. UV-VIS 분광광도계를 사용하여 박막의 투과도와 흡광도를 측정하였으며, Tauc의 모델을 사용하여 밴드갭 에너지를 계산하였다. 증착 온도 변화에 따라 성장된 박막의 투과도는 평균 82% 이상 이었으며 밴드갭 에너지는 4.1 eV이었다. 박막의 결정 구조는 단사정계임을 확인하였다. 특히, 결정 입자, 발광 피크의 세기와 투과도의 상관 관계를 조사하였다.

  • PDF

A Study on Characteristics of Temperature and Radicals in Laminar Non-premixed H2/N2 Flame Using LIPF and LRS (레이저 유도 선해리 형광법과 래일레이 산란법에 의한 층류 비예혼합 수소/질소 화염의 온도 및 라디칼 특성에 관한 연구)

  • Jin, Seong Ho;Park, Kyoung Suk;Kim, Gun Hong;Kim, Gyung Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.3
    • /
    • pp.169-180
    • /
    • 2002
  • Rayleigh scattering and laser induced predissociative fluorescence are used to obtain two-dimensional images of temperature and species concentration in a laminar non-premixed flame of a diluted hydrogen jet. Rayleigh scattering cross-sections are experimentally obtained at 248nm. Planar images of OH and $O_2$ with tunable KrF excimer laser which has a) $0.5cm^{-1}$ linewidth, b) 0.5nm tuning range, c) 150mJ pulse energy, and d) 20ns pulse width are obtained to determine spatial distributions of OH and $O_2$. The technique is based on planar laser induced predissociative fluorescence (PLIPF) in which collisional quenching is almost avoided because of the fast predissociation. Dispersed LIPF spectra of OH and $O_2$ are also measured in a flame in order to confirm the excitation of single vibronic state of OH and $O_2$. OH and $O_2$ are excited on the $P_2$(8) and $Q_1$(11) line of the $A^2{\Sigma}^{+}({\nu}^{'}=3)-X^{2}{\Pi}({\nu}^{''}=o)$ band and R(17) line of the Schumann-Runge band $B^{3}{\Sigma}_{u}{^-}(\nu^{'}=0)-X^{3}{\Sigma}_{g}{^-}({\nu}^{''}=6)$, respectively. Fluorescence spectra of OH and Hot $O_2$ are captured and two-dimensional images of the hydrogen flame field are successfully visualized.

Evaluation the absorbed dose in brain of dental radiography (치과방사선 검사에서 두부(brain)의 흡수선량 평가)

  • Jeon, Woon-Sun;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.343-349
    • /
    • 2011
  • This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.

TLD dose variation of Magnetic Resonance Imaging Equipment (자기공명영상장비에서 열형광선량계의 선량 변화)

  • Je, Jaeyong;Kang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.473-476
    • /
    • 2012
  • The PET-MRI which has been installed and being managed recently uses both magnetic field and radiation. Most radiation workers wear a thermoluminescenct dosimeter (TLD) as a personal radiation dosimeter, and the TLD is affected both by a magnetic field and radiation. In this research, the same amount of X-ray was applied to 36 TLDs, and the changes in the dose of the 32 TLDs exposed to magnetic field at the location where its intensity of the magnetic resonance imaging (MRI) was about 5000 Gauss for eight hours with one-hour unit and that of the four TLDs not exposed to magnetic field were compared and checked. The measurement result showed that exposure dose of the TLD attached to the MRI changed irregularly depending on the amount of exposure time. Therefore, the TLD whose amount of changes little in the environment of a MRI is demanded to be developed.

Hydrogen Production from Splitting of Methanol/Water Solution Using Perovskite Structured NbxSrTi1-xO3 Photocatalyts (Perovskite NbxSrTi1-xO3 광 촉매를 이용한 메탄올/물 분해로부터 수소제조)

  • Kim, Dongjin;Han, Gi Bo;Park, No-Kuk;Lee, Tae Jin;Kang, Misook
    • Korean Chemical Engineering Research
    • /
    • v.51 no.4
    • /
    • pp.513-517
    • /
    • 2013
  • This study focused on the synthesis of $Nb_xSrTi_{1-x}O_3$ photocatalysts which partially inserted Nb ions with excellent ability of fluorescence into the perovskite structured $SrTiO_3$ frameworks and their photocatalytic hydrogen productions from methanol/water splitting corresponding to the molar ratios of Ti and Nb. The characteristics of the synthesized $SrTiO_3$ and $Nb_xSrTi_{1-x}O_3$ powders were analyzed by X-ray diffraction (XRD), energy dispersive X-ray spectrometer (EDS), and UV-Visible spectrometer. The hydrogen evolution from methanol/water photo-splitting was enhanced over $Nb_{0.05}SrTi_{0.95}O_3$ compared to those over $SrTiO_3$ and another $Nb_xSrTi_{1-x}O_3$; 4.9 mL of hydrogen gases was collected after 8 h when 0.5g of $Nb_{0.05}SrTi_{0.95}O_3$ catalyst was used in pH 10.

A Study on X-Ray Fluorescence Analysis of Ta$_2O_5,\;Nb_2O_5,\;SnO_2$ and ZrO$_2$ in Tin-slag Samples (희석 파라미터법에 의한 주석슬랙중 Ta$_2O_5,\;Nb_2O_5,\;SnO_2$ 및 ZrO$_2$의 X-선형광분석에 관한 연구)

  • Young Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.265-270
    • /
    • 1985
  • Ta$_2$O$_5$, Nb$_2$O$_5$, SnO$_2$ and ZrO$_2$ in tin-slag samples were determined by X-ray fluorescence spectrometry using the dilution parameter method and the analytical results were compared with the data obtained by standard calibration curve method. Tin-slag samples and one standard sample having very similar composition to the tin-slags were diluted with a proper diluent (La$_2$O$_3$) to the ratio of 1: 1, 1 : 2, 1 : 3 and 1 : 4. After measuring the X-ray intensities of original and diluted samples, the values of dilution parameters were calculated by using the dilution parameter equation. Without any calibration curve, the analytical results were calculated from the equation including the dilution parameter term. The results were in good agreement with the reference data by the standard calibration curve method.

  • PDF

A Study on Test Method of Flame Retardant EPS using XRF (X-선 형광분석기를 활용한 난연EPS 성능확인방법 연구)

  • Cho, Nam-Wook;Chun, Ji-Hong;Choi, Jae-Bum;Rie, Dong-Ho;Shin, Hyun-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.352-356
    • /
    • 2011
  • 주로 탄화수소화합물로 구성된 EPS(Expended poly styrene)는 뛰어난 단열성능, 경제성, 건식공법의 시공편리성으로 단열재로 많이 사용되지만 화재에 취약한 단점이 있다. 최근 EPS패널의 다양한 난연화를 통해 난연EPS패널제품이 개발되고 있고 시장에서의 사용이 증가되고 있다. 그러나 가짜 난연EPS제품의 사용이 사회적 문제가 되고 있는 것도 현실이다. 본 연구에서는 난연EPS와 일반EPS가 성분이 다른점을 이용하여, 현장에서 시공되고 있는 시료의 진위여부 판단을 위해 X-선형광분석기(XRF)를 사용한 원소분석을 시도하였다. 분석결과 매우 간단한 방법으로 시료의 진위여부를 확인할 수 있었으며, 따라서 현장에서 사용될 수 있는 분석법으로 적용가능성에 대하여 고찰하였다.

  • PDF