• Title/Summary/Keyword: 형광 센서

Search Result 139, Processing Time 0.036 seconds

Radiation Resistance of BGO:Eu Scintillator (BGO:Eu 섬광체의 방사선 저항)

  • Kim, Jong-Il;Jeong, Jung-Hyun;Doh, Sih-Hong;Hwang, Hae-Sun;Kim, Sung-Chuel;Kim, Jung-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.16-23
    • /
    • 1997
  • Bismuth germanate crystals well known as scintillator were grown by Czochralski method. In order to understand a mechanism of radiation resistance in Eu-doped BGO, we measured radiation induced-absorption spectra, excitation spectra, emission spectra and luminescence lifetimes of BGO crystals. We found that the charge transfer state of $Eu^{3+}$ ion is to play a key role to enhance the radiation resistance in BGO crystal. The $^{5}D_{0}$ emission of $Eu^{3+}$ ions that is not suitable for the radiation detectors due to a long decay time was found to be increased with increasing europium concentration. In the BGO crystal doped with 0.1 mole%, the density of radiation induced color centers was reduced about twenty times and the light output of $^{5}D_{0}$ was negligible by comparing to that of BGO.

  • PDF

Thermoluminescence and Photostimulated Luminescence of BaFBr:BaFBr:Eu2+ Phosphor (BaFBr:Eu2+ 형광체의 열발광 및 광자극발광 특성)

  • Doh, Sih-Hong;Seo, Hyo-Jin;Kang, Kab-Jung;Kim, Young-Kook;Kim, Do-Sung;Kim, Sung-Hwan;Kim, Chan-Jung;Lee, Byung-Hwa;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.301-308
    • /
    • 2002
  • BaFBr:$Eu^{2+}$ phosphors were prepared, and the thermoluminescence(TL) and photostimulated luminescence(PSL) of the prepared phosphors were measured. Two glow peaks around 352 and 448 K are observed for x-ray irradiated BaFBr:$Eu^{2+}$ phosphors, and the activation energy of the main glow peak(352 K) was about 0.96 eV. The spectral range of the PSL was $350{\sim}450\;nm$, and the activation energy of the trap giving rise to PSL was about 0.98 eV. The activation energy of the traps giving rise to TL is agreed to those giving rise to PSL within experimental error.

Thermally Stimulated Exoelectron Emission from LiF(Mg,Cu,Na,Si) Phosphor (LiF(Mg,Cu,Na,Si)형광체의 열자극엑소전자방출)

  • Doh, Sih-Hong;Jeong, Jung-Hyun;Aoki, M.;Nishikawa, T.;Tamagawa, Y.;Isobe, M.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.11-15
    • /
    • 1994
  • The TSEE characteristics of LiF(Mg,Cu,Na,Si)phosphor for gamma and beta rays are described. The TSEE glow curve of this phosphor showed 5 peaks in the range from $20^{\circ}C$ to $400^{\circ}C$ and its main peak appeared at $240^{\circ}C$. The sensitivity of the phospor for $^{60}Co$ gamma rays was about 450counts/mR. TSEE energy dependence for various beta radiation was nearly constant (${\pm}10%$) in the mean beta particle energy range from 0.02MeV to 0.8MeV. The efficiency of TSEE of the phosphor for beta radiation was $(2{\sim}15){\times}10^{-3}$.

  • PDF

Thermal Annealing and Fading Characteristics of LiF:Mg,Cu,P TLD (LiF:Mg,Cu,P TLD의 잠상퇴행과 열처리 특성)

  • Doh, Sih-Hong;Lee, Woo-Gyo;Yoo, Myung-Jin;Kang, Hee-Dong;Kim, Do-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.313-318
    • /
    • 1998
  • The thermal annealing, reusability and fading characteristics of the highly sensitive LiF:Mg,Cu,P TLDs are investigated. Thermoluminescent sensitivity of the fabricated LiF:Mg,Cu,P TLD is 25.3 times higher than the commercial dosimeter TLD-700(Harshaw Chemical Co.). The main dosimetric peak shows no fading for 1 month at room temperature and 50% for 7 days at $100^{\circ}C$. The thermal annealing characteristics is examined in the temperature range from $260^{\circ}C$ to $320^{\circ}C$. For annealing the TLD at $280^{\circ}C$ for 10 minutes, TLDs can be reusable by recovering the initial sensitivity.

  • PDF

A study on algal concentration analysis using a fluorescent sensor (형광센서를 활용한 조류 농도 분석에 대한 연구)

  • Lim, Jae Yeon;Kim, Gwang-Su;Nam, Su Han;Kim, Young Do
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.261-261
    • /
    • 2022
  • 최근 국내 녹조현상의 빈도가 잦아지고, 지속기간이 증가하였다. 이러한 녹조현상은 이상기후로 인한 일사량, 수온, 체류시간 증가로 인한 환경적인 영향이 있으며, 산업단지 및 농지 등에서 유출되는 질소나 인의 부영양화로 인한 인위적 영향이 있다. 조류종 중 특히 남조류가 생장하는 과정에서 발생하는 독성물질(간독소, 신경독소), 이취미 물질(Geosmin, 2-MIB 등)은 수질을 악화시키고 있어 생태계에 큰 영향을 미친다. 조류는 하천에서 넓은 분포로 발생하게 되는데 현재 조류 조사 방법은 현장에 발생한 조류를 직접 채취하여 연구실에서 현미경으로 직접 검경하기 때문에 많은 인력과 시간, 비용이 소비되고 있는 실정이다. 국내에서는 인력과 시간을 줄이기 위해 센서를 활용한 조류분석 및 원격탐사 기법을 이용한 조류 모니터링에 대한 연구가 많이 진행되고 있다. 하지만 하천에서는 녹조류와 남조류 모두 혼합되어 존재하며 센서를 이용하여 조류를 분석할 시 녹조류는 Chl-a, 남조류는 Phycocyanin을 대체하여 분석하고 있다. 하지만 모든 조류는 광합성을 하기 때문에 Chl-a를 모두 함유하고 있어 Chl-a만으로 남조류를 추정하는 데에는 한계가 있다. 따라서 본 연구에서는 조류 계측장비인 LISST-HAB를 통하여 조류시료의 농도를 측정하여 Chl-a, Phycocyanin 농도를 측정하여 조류종 분류에 대한 분석을 진행하였다.

  • PDF

Pre-processing Algorithm for Analysis from Microarray Image Sequence by Surface Plasmon Resonance Biosensor (SPR 센서로 촬영된 마이크로어레이 영상 분석을 위한 전처리 알고리즘)

  • 황지운;김재학;한준희
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04b
    • /
    • pp.250-252
    • /
    • 2004
  • 나노 기술의 개발과 마이크로어레이(microarray)의 등장으로 생물학자동을 한번에 보다 라르고 신속하게, 대량의 실험을 처리할 수 있게 되었다. 이와 발 맞추어 마이크로어레이를 이용한 다양한 실험 방법들이 개발되었다. 형광 염료(fluorescence dye)를 이 용한 관찰 방법 이 널리 이용되고 있으나, 관찰되는 형광 염료의 밝기가 실험 환경(pH, 온도)에 매우 민감하게 반응하며, 단백질을 포함한 많은 분자 물질들이 형광을 내지 않기 때문에 마이크로어레이를 이용한 분석 대상 물질들의 개수가 제한을 받는다. 본 논문에서는 직접적인 형광 염료의 사용 없이, SPR(Surface Plasmon Resonance)을 이용한 마이크로어레이 분석 시스템에서 스팟(spot)의 밝기(intensity)를 측정하기 위한 효율적인 전처리 과정을 제안하고자 한다. 전처리 과정은 크게 프로젝티브 왜곡 효과 제거, 스팟의 위치 추적, 스팟의 영역 추출, 정규화 된 스팟의 밝기 측정으로 나누어진다. 특히, 이러한 과정을 거쳐서 측정된 밝기는 반응 유무의 관찰뿐만이 아니라, 실험 물질의 양적인 측정에도 이용되기 때문에 정확한 스팟의 밝기 측정에 중점을 두고자 한다.

  • PDF

Design of Illumination Control System Using Microwave Sensors and Dimming Control (마이크로웨이브센서와 디밍제어를 활용한 조명제어시스템 설계 및 구현)

  • Song, Eun-Seong;Min, Byoung-Won;Oh, Yong-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.19-26
    • /
    • 2013
  • In this paper, we present a novel illumination system for parking lots constructed underground. We design and implement this system using microwave sensors and dimming control of LED fluorescent lamps so that we can obtain lighting efficiency of the illumination scheme. We construct an effective illumination system in the aspects of performance and cost, resulting in energy-saving and electricity reduction. Recently conventional energy-saving method applied to old underground parking lots mainly relies upon turning off the half of total number of lamps installed in the parking lot. Sometimes there are some lots that have infrared sensor to be used to turn on/off the fluorescent lamps to realize these operations smoothing. The other schemes utilize timer to control lighting time of the fluorescent lamps. These conventional schemes are forcing to turn off a part of lamps installed so that we cannot apply them in a systematic way. Moreover they will be most inefficient when we leave them alone to be continuous consumers. The lighting control system proposed in this paper can recognize objects through microwave sensors and inform the appropriate lighting time, furthermore we can adjust brightness of LED lamps following the surroundings using dimming control scheme so that we can epochally improve the illumination system for underground parking lots. According to our sophisticated test experiments, we can maximally obtain 81.9% of energy-saving effectiveness using the system proposed in this paper.

Signal Analysis of Optical Biosensor to Detect Peroxide Using Electrically Controlled Release System (전기적 방출 조절 시스템을 이용한 광 페록사이드센서의 개발)

  • Min, Jun-Hong;Lim, In-Hee;Kim, Hyo-Han;Lee, Sang-Beak;Choi, Jeong-Woo;Lee, Won-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.35-42
    • /
    • 1997
  • The optical biosensor using the electrically controlled release of reactive reagent is developed for the detection of peroxide. Rapid degradation of polymer complex of PEOx and PMAA occurs as the applied current increases and thus released amount of HPA increases. The degradation velocity of polymer and the amount of HPA released are linearly proportional to the applied current. Peroxide is reacted with the released reagent by peroxidase and then the product, a fluorescent dimer DBDA, is formed. The monochromic light from light source (150W Xe arc ramp) excites the DBDA and the excited light is transmitted through an optical fiber to be detected by a photodiode array. The change of fluorescence intensity is related to the change of peroxide concentration. The peroxidase is entrapped in Ca-alginate get on the inner surface. The biosensor has the linear signal range of 0.025mM-10.mM peroxide. By applying the step function of peroxide, reproducibility of biosensor has been investigated. The mathematical model is constructed by the combination of enzyme kinetics with reactor flow model. Good agreement is obtained between the experimental result and model prediction in the sensor signal.

  • PDF

Implementation of paper-based Ion concentration polarization phenomenon and Bio-sensor of commercialization concept (페이퍼기반 이온 농도 분극 현상 구현 및 상용화 컨셉의 바이오 센서)

  • Han, Sung Il;Kwak, Rhokyun;Lee, Jeong Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1219-1220
    • /
    • 2015
  • 마이크로, 나노유체 (micro-, nanofluidics)을 이용한 종이 기반 분석 소자 (paper-based analytical devices, micro-PADs)에 대한 관심이 증가하고 있다. 종이 기반의 분석 소자는 초저가의 비용과 간단한 공정 방법으로 인하여 상용화 컨셉의 바이오센서로 각광받고 있다. 하지만, 종이 기반의 분석 소자는 낮은 검출 한계 (limit of detection, LOD)와 민감도 (sensitivity)의 제한이 있다. 그로 인해 우리는 이온 선택적 투과층 (ion permselective membrane, i.e. Nafion)을 종이 기반의 분석 소자와 결합하여 이온 농도 분극 (ion concentration polarization, ICP) 현상을 구현하여 낮은 검출한계와 민감도를 개선할 수 있었다. 접착력이 있는 테이프 표면에 이온 선택적 투과층을 패터닝 (patterning)하여 종이 기반 분석 소자와 결합하여 매우 간단하게 소자를 제작할 수 있었다. 따라서 종이 기반의 채널 양단에 직류 전압을 인가했을 때 발생하는 ICP 현상으로 인하여 형광 물질 (fluorescence dye)이 농축(preconcentration)되는 것을 확인할 수 있었다. 구체적으로, 초기 농도가 1.55 nM인 형광 물질을 이용하여 200 V의 외부전압을 인가했을 때, 500 초 이내에 1000 배 이상의 농축비를 얻을 수 있었다. 따라서, 외부 전압을 상용화된 건전지 출력값으로 낮출 수 있다면 다양한 종이 기반 분석 소자와 간단한 결합 방법을 통해 상용화 컨셉의 바이오센서로도 구현이 가능할 것이다.

  • PDF

Microfluidic Fabrication of Conjugated Polymer Sensor Fibers (미세유동을 이용한 공액 고분자 센서 섬유 제작)

  • Yoo, Imsung;Song, Simon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.853-858
    • /
    • 2014
  • We propose a fabrication method for polydiacetylene (PDA)-embedded hydrogel microfibers on a microfluidic chip. These fibers can be applied to the detection of cyclodextrines (CDs), which are a family of sugar and aluminum ions. PDA, a family of conjugated polymers, has unique characteristics when used for a sensor, because it undergoes a blue-to-red color transition and nonfluorescence-to-fluorescence transition in response to environmental stimulation. PDAs have different sensing characteristics depending on the head group of PCDA. By taking advantage of ionic crosslinking-induced hydrogel formation and the 3D hydrodynamic focusing effect on a microfluidic chip, PCDA-EDEA-derived diacetylene (DA) monomer-embedded microfibers were successfully fabricated. UV irradiation of the fibers afforded blue-colored PDA, and the resulting blue PDA fibers underwent a phase transition to red and emitted red fluorescence upon exposure to CDs and aluminum ions. Their fluorescence intensity varied depending on the CDs and aluminum ion concentrations. This phase transition was also observed when the fibers were dried.