• Title/Summary/Keyword: 혈압계

Search Result 201, Processing Time 0.027 seconds

Verification of Reliable Blood Pressure Monitor in a Moving Ambulance during an Emergency (응급상황시 이송중인 구급차에서 신뢰할 수 있는 혈압계 검증)

  • Jeon, Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.91-97
    • /
    • 2022
  • The purpose of this study was to analyze the measurements of blood pressure and time using manual and automatic blood pressure monitors in various road conditions to verify reliable blood pressure monitor in a moving ambulance. First, the manual blood pressure monitor palpation on unpaved roads showed a systolic pressure deviation of 5 mmHg. However, the automatic blood pressure monitor showed two measurement failures, one reading failure, and the measured systolic pressure deviation was 35 mmHg. The measurement time was 102 seconds faster on average than the automatic blood pressure monitor. Second, the palpation of the manual blood pressure monitor while going over speed bumps remained constant at 130 mmHg. However, the automatic blood pressure monitor had a systolic pressure deviation of 52 mmHg. The measurement time was 61 seconds faster on average than the automatic blood pressure monitor. Finally, the manual blood pressure monitor palpation on the sharp curve road showed a systolic pressure deviation of 5 mmHg. The automatic blood pressure monitor had one reading failure and the measured systolic pressure deviation was 21 mmHg. The measurement time showed that the manual blood pressure monitor was 101 seconds faster than the automatic blood pressure monitor. As a result, in a moving ambulance during an emergency, the manual blood pressure monitor showed high reliability because the blood pressure measurement was constant and the measurement time was short.

Development of Electronic Circuit for Korotkoff Sounds Detecting Signal on Forearm Electronic Blood Pressure Monitor (팔뚝 전자혈압계의 코로트코프 음 신호 검출을 위한 전자 회로 개발)

  • Lee, Sangsik;Cho, Yoehan;Goo, Jihyun;Lee, Choongho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • In this study, we developed a circuit device detecting korotkoff sounds of forearm electronic blood pressure monitor by digital signal. In order to test a circuit detecting signal from korotkoff sounds, systolic and diastolic pressure were compared our developed circuit device with the existing forearm electronic blood pressure monitor (Model: SE-7000, Korea). Devices for an experiment composed of a forearm cuff, a stethoscope, an amplifier, a PC with A/D board, etc. Results of korotkoff sounds was similar to a pattern of oscilometric signals from the existing forearm electronic blood pressure monitor. We thought it is possible to measure blood pressures, if blood pressures were detected precisely using signals of korotkoff sounds.

  • PDF

Development of Blood Pressure Measurement Method Using ANFIS (ANFIS를 이용한 전자 혈압 측정 알고리즘 개발)

  • Kwon Seok-Young;Lee Dae-Jong;Chung Myung-Geun
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.219-222
    • /
    • 2006
  • 본 논문에서는 ANFIS를 이용한 전자혈압계 측정알고리즘을 제안한다. 이를 위해 본 연구에서는 우선, 기존의 팔뚝형 커프와 수동 공기주입기 방식의 전자혈압 측정시스템을 구축하여 혈압 신호를 실시간으로 취득하였다. 다음단계로 취득된 실시간 혈압신호를 이용하여 최고혈압과 최저 혈압을 측정하기 위해 MAA(Maximum Amplitude Algorithm) 기법을 이용한다. 그러나, MAA기법은 개인의 특성을 고려하지 않고 일정한 비율을 고정시키므로 정확한 혈압을 측정하는데 한계가 있다. 따라서, 본 논문에서는 MAA에 의해 측정된 최고혈압과 최저혈압을 ANFIS를 이용하여 학습시키므로서 이러한 문제점을 해결하고자 한다. 제안된 알고리즘의 효율성을 보이기 위해 다양한 혈압신호에 대해 실험한 결과 기존의 MAA에 의한 방법보다 향상된 결과를 나타냈다.

  • PDF

Design of U-healthcare System for Real-time Blood Pressure Monitoring (실시간 혈압 모니터링 u-헬스케어 시스템의 설계)

  • Cho, Byung-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.161-168
    • /
    • 2018
  • High blood pressure is main today's adult disease and existing blood pressure gauge is not possible for real-time blood pressure measurement and remote monitoring. But real-time blood pressure monitoring u-healthcare system makes effect health management. In my paper, for monitoring real-time blood pressure, an architecture of real-time blood pressure monitoring system which consisted of wrist type-blood pressure measurement, smart-phone and u-healthcare server is presented. And the analog circuit architecture which is major core function for pulse wave detection and digital hardware architecture for wrist type-blood pressure measurement is presented. Also for software development to operate this hardware system, UML analysis method and flowcharts and screen design for this software design are showed. Therefore such design method in my paper is expected to be useful for real-time blood pressure monitoring u-healthcare system implementation.

The Risk Factors of the Pre-hypertension and Hypertension of Rural Inhabitants in Chungnam-do (충남 농촌 지역 주민의 고혈압 전단계와 고혈압의 위험요인)

  • Eom, Ji-Sook;Lee, Tae-Ryong;Park, Seon-Joo;Ahn, Youn-Jin;Chung, Young-Jin
    • Journal of Nutrition and Health
    • /
    • v.41 no.8
    • /
    • pp.742-753
    • /
    • 2008
  • The purpose of this study is to investigate risk factors of pre-hypertension and hypertension in rural residents. Nine hundred and ninety four subjects aged 40-70 yrs in Chungnam-do participated in this study. The subjects (n = 824) were classified into three groups of hypertensive, pre-hypertensive, and normotensive according to the Joint National Committee (JNC)-7 criteria. The weight, body mass index (BMI), waist-hip ratio (WHR), and serum total protein, albumin, BUN, and triglyceride (TG) were positively correlated with SBP and DBP. After adjusted by age, sex and BMI, the total protein, albumin and TG were significantly correlated with SBP and DBP (p < 0.01). There was no significant difference in eating habits according to the level of blood pressure. The serum albumin, creatinine, Glu-FBS, Glu-PP l20, and triglyceride were higher in both prehypertensive and hypertensive group than in the normotensive group. However, mean serum cholesterol was not different among three blood pressure groups. In this study, the common risk factors of pre-hypertension and hyper-tension were male, age of fifties, lower education level, ex-smoking, higher drinking frequency, higher BMI, body fat %, waist circumference, WHR, serum albumin and diabetes, even though the degree of risks in these variables were higher in the hypertensive group. The higher BUN was a risk factor of prehypertension, while the family history, prediabetes, serum total protein, Glu-PP l20 and higher alcohol drinking amount were the risk factors of hypertension. This result suggests that maintaining good health habit and normal range of blood parameters as well as controlling body weight have to be paid attention in order to prevent hypertention, and further reseasch on the relationship of blood pressure and BUN are needed.

Diagnosis parameters extraction by correlativity analysis of blood pressure(BP) and head blood pressure(HBP) and Development of multi-function automatic blood pressure monitor (상완혈압과 두부혈압의 상관성 분석에 의한 진단요소 추출과 다기능 전자혈압계의 개발)

  • 이용흠;고수복;정동명
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.6
    • /
    • pp.58-67
    • /
    • 2003
  • Many adult diseases(cerebral apoplexy, athymiait, etc.) result from hypertension, blood circulation disturbance and increment of HBP. In early diagnosis of these diseases, MRI, X-ray and PET have been used rather aim for treatment than prevention of a disease. Since, cerebral apoplexy and athymiait have been caused to the regular/irregular persons, it is very important to measure HBP which has connection with cerebral blood low state. HBP has more diagnosis elements than that of BP. So, we can diagnose accurate hypertension by measuring of HBP. But, existing sphygmomanometers and automatic BP monitors can not measure HBF, and can not execute complex function(measuring of BP/HBP, blood flow improvement). The purpose of this paper is to develop the system and algorithm which can measure BP/HBP for accurate diagnosis. Also, we extracted diagnosis factors by the correlativity analysis of BP/HBP. The maximum pressure of HBP corresponds to 62% that of BP, the minimum pressure of HBP corresponds to 46% that of BP. Therefore, we developed the multi function automatic blood pressure monitor which can measure BP/HBP and improve cerebral blood flow state.

Blood Pressure control application using Android Open Accessory Development Kit (Android Open Accessory Development Kit를 이용한 혈압계 제어 application)

  • Park, Hee-Jung;Jung, Hae-In;Lee, Young-Jae;Lee, Jae-Ho;Lim, Min-Gyu;Lee, Jeong-Whan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.409-410
    • /
    • 2012
  • 본 논문에서는 스마트케어 서비스를 위해, Android 운영체제를 기반으로 하는 Device에서 ADK를 이용해 혈압계를 제어하는 방법을 제안한다. 이 방법은 소프트웨어와 하드웨어를 결합한 kit인 ADK를 사용하여 Hardware를 잘 모르는 사람들도 Android에서 Hardware의 GPIO에 좀 더 쉽게 접근하고 제어할 수 있어 보다 다양한 기능을 구현할 수 있다. 또한 이 방법으로 얻은 혈압계 데이터를 Database에 저장하여 데이터통신망을 통해 전문의에게 Feedback을 받음으로써 굳이 병원을 방문하지 않더라도 개인의 건강을 보다 편리하게 관리할 수 있어 한 단계 수준 높은 진단을 받을 수 있다.

  • PDF

당뇨병 환자의 고혈압 유병률

  • 손성표
    • The Monthly Diabetes
    • /
    • s.151
    • /
    • pp.18-19
    • /
    • 2002
  • 당뇨병 환자에서 고혈압은 미세혈관 및 대혈관 합병증을 촉반 혹은 악화시킬 수 있으므로 임상적으로 매우 중요하다. 당뇨병 환자에서 사망의 원인은 주로 대혈관 합병증인 관동맥심장질환, 심비대, 울혈성 심부전증, 뇌졸중, 말초혈관 질환 등의 심혈관계 및 뇌혈관계 질환때문이며, 당뇨병이 없는 사람에 비해 이들 질환의 빈도는 2$\~$6배나 높다. 고혈압도 심혈관계 및 뇌혈관계 독립인자로서 당뇨병 환자에서 고혈압이 동반되면 각각을 동반할 때보다 이들 질환의 발생 위험도는 훨씬 높아진다. 이들 질환에 의한 사망률 증가뿐 아니라 당뇨병의 미세혈관 합병증인 망막증과 신증의 발생률이 고혈압을 동반할 때 증가하며, 특히 기존의 신증 혹은 망막증의 진행은 고혈압이 나타나면 촉진된다. 임상적으로 더욱 중요한 사실은 이러한 고혈압을 치료함으로써 이들 합병증의 진행을 지연시키거나 막을 수 있다는 것이며, 이미 당뇨병성 신증환자에서 고혈압 치료의 효과가 밝혀져 있다. 따라서 당뇨병 환자에서 고혈압을 반드시 조기에 확인하여 적극적으로 치료하여야 한다.

  • PDF

Development of Blood Pressure Measurement Method Using ANFIS (ANFIS를 이용한 전자 혈압 측정 알고리즘 개발)

  • Chun Myung-Geun;Kwon Seok-Young;Lee Dae-Jong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.4
    • /
    • pp.493-498
    • /
    • 2006
  • In this paper, we propose a blood pressure measurement method using ANFIS. Usually, the maximum and minimum blood pressures are calculated by Maximum Amplitude Algorithm(MAA) method. However, the MAA method has some drawbacks to measure exact blood pressure since it uses a fixed ratio to set the measuring points for everyone without considering individual's special conditions. To solve this problem, the pressures measured by the MMA are trained by ANFIS having self-learning ability. From various experiments, we confirm that the proposed method shows better performance than conventional method.

Normal blood pressure values and percentile curves measured by oscillometric method in children under 6 years of age (진동식 자동 혈압계로 측정한 6세 이하 아동의 정상 혈압치와 백분위수 곡선)

  • Sohn, Jin A;Lee, Hee Sook;Lim, Kyoung Aha;Yoon, So Young;Jung, Jo Won;Kim, Nam Su;Noh, Chung Il;Lee, Soon Young;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.998-1006
    • /
    • 2008
  • Purpose : Hypertension is defined as average systolic blood pressure and/or diastolic blood pressure that is ${\geq}95^{th}$ percentile for gender, age, and height on ${\geq}three$ occasions. Knowing that blood pressure values increase in children as they grow older, the purposes of this study were to measure blood pressure by an oscillometric device and to determine normal values and percentile curves for children. Methods : Systolic and diastolic blood pressures were measured twice with an oscillometric device in 3,545 boys and 3,145 girls under six years of age, in Seoul. Using this data, we determined average blood pressure values and percentile curves based on gender and age; we subdivided these values into blood pressures of $50^{th}$, $90^{th}$, $95^{th}$, and $99^{th}$ percentiles, by percentile of height. The regression coefficients and standard deviations of the systolic and diastolic blood pressure values were obtained from linear regression models. Results : Older boys and girls had higher systolic and diastolic blood pressure values. Older boys and girls in the same percentile of height for age had higher systolic and diastolic blood pressure values. Taller boys and girls within the same age group had higher systolic and diastolic blood pressure values. Conclusion : Blood pressure standards based on gender, age, and height were obtained via an oscillometric method. Llimitation of this study is that the study population was not from the whole country, but exclusively from Seoul. Nonetheless, the data from this study will be helpful in diagnosing and managing hypertension in Korean children.