• 제목/요약/키워드: 현휘

검색결과 17건 처리시간 0.021초

잠재적 시간 오차에 따른 현휘의 발생 방지를 위한 최적 블라인드 제어 (Optimum Blind Control to Prevent Glare Considering Potential Time Error)

  • 성윤복
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.74-86
    • /
    • 2012
  • For the improvement of environmental comfort in the buildings with the blind control, the objective of this study is to prevent the direct glare caused by the daylight inlet. During the process of solar profile prediction, time are significant factors that may cause error and glare during the blind control. This research proposes and evaluates the correction and control method to minimize prediction error. For the local areas with different longitude and local standard meridian, error occurred in the process of the time conversion from local standard time to apparent solar time. In order to correct error in time conversion, apparent solar time should be recalculated after adjusting the day of year and the equation of time. To solve the problems by the potential time errors, control method is suggested to divide the control sections using the calibrated fitting-curve and this method is verified through simulations. The proposed correction and control method, which considered potential time errors by loop lop leap years, could solve the problems about direct glare caused by daylight inlet on the work-plane according to the prediction errors of solar profile. And also these methods could maximize daylight inlet and solar heat gain, because the blocked area on windows could be minimized.

대학강의실 전면현휘 감소를 위한 주간채광유입 시뮬레이션에 관한 연구 (A Study on Simulation of Daylight for Reducing Glare of the Lecture Room's Front Side in University)

  • 정지석
    • 한국주거학회논문집
    • /
    • 제24권3호
    • /
    • pp.1-8
    • /
    • 2013
  • The University students learn their major or a general education in lecture rooms. In these days, lecturer use frequently various multimedia in lecture room. Appropriate control lighting environment in lecture room should be essential and related in efficient studying. Daylighting on front-side of lecture room will cause glare and students are hard to read contents on white-board at their seat. Therefore, in order to preventing glare we simulated daylighting of lecture room with using computer software in this study. Results from simulation and analysis as follows: The first, if students' left-side is east-oriented in lecture room, best daylighting condition about glare in lecture room. The second, architectural designers can use simulation data of daylighting or simulate data in designing university buildings with lecture rooms. Finally, if reducing size of windows (narrow and deep daylight: more closing vertically, from up to down daylighting: more closing horizontally) we will be able to reduce energy from lecture room.

빛에 의한 치료적 효과 기반의 한국형 치매요양시설의 자연채광 계획지표 개발 - 주광 가용성 최대화, 치료적 조망 최적화 및 현휘 최소화 지표 중심으로 (A Daylighting Design Indicator for Korean Dementia Nursing Homes Based on the Therapeutic Effects of Light - Focusing on maximizing daylight availability, optimizing therapeutic views, and minimizing glare)

  • 지수인
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권1호
    • /
    • pp.29-42
    • /
    • 2023
  • Purpose: This study aimed to develop a daylighting design indicator for Korean dementia nursing homes based on the therapeutic effects of light, focusing on the serious aging index facing Korea and the importance of natural light that occupies the most important position in the therapeutic environments for the elderly with dementia. Methods: A wide range of literature-oriented research methods were mobilized to develop the daylighting design indicator of Korean dementia nursing homes. Results: The daylighting design indicator of Korean dementia nursing homes was derived from three perspectives: maximizing daylight availability, optimizing therapeutic view, and minimizing glare. In addition, eighteen basic indicators were derived within seven indicator items in the range of building layout, windows, glazing, shading devices, spaces, interior finishings, and daylight factor. Implications: The daylighting design indicator of Korean dementia nursing homes revealed in this study will contribute to realizing Korean dementia nursing homes as a therapeutic environment for the elderly with dementia.

작업면 현휘 방지와 주광 및 일사 유입 최대화를 위한 제어 종료 영역에서의 최적 블라인드 제어 (Optimum Blind Control at the End of Operation Time Zone for Preventing Glare on Work-plane and Maximizing Daylight and Solar Heat Gain)

  • 성윤복;여명석;구소영;김광우
    • 한국주거학회논문집
    • /
    • 제23권1호
    • /
    • pp.27-41
    • /
    • 2012
  • The objective of this study is to develop the blind control strategy and method which reduce negative effect of incoming daylight on visual comfort of occupants, minimize psychological anxieties caused by frequent motions of a blind, and maximize positive effect of incoming daylight and solar irradiation by opening/closing of a blind. As previous researches on blind controls have limited outdoor environmental conditions to those in specific regions, orientations and dates, these resulted in problems at various conditions for general-purpose application. Major problem is that the time interval and amount of blind movement do not meet the control objective at the end of control zone and discontinuous curve. To overcome these limitations revealed in the previous researches, following tasks were performed in this study. 1) To establish the control objective to accomplish the goal of this study. 2) To develop the control methods and algorithms which prevent glare on the work-plane at any time and which control the time interval and amount of blind movement to follow the control objective at various profile angle curves. 3) To validate the general-purpose applicability and performance of the developed control methods and algorithms by simulation and its data analysis at various conditions. It was found that the proposed methods and algorithms can prevent the direct glare on the work-plane at all the time and also increase the incoming daylight and solar irradiation.

건물에너지성능 및 불쾌현휘를 고려한 고정형 블라인드의 최적 슬랫각도 도출 방법에 관한 연구 (A Elicitation Method of Optimum Slat Angle of Fixed Venetian Blind Considering Energy Performance and Discomfort Glare in Buildings)

  • 박장우;윤종호;오명환;이광호
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.107-112
    • /
    • 2012
  • The purpose of this study is to determine the optimum slat angle of the venetian blind which was applied at an outer skin of a curtain-wall system. The evaluation of the blind slat angle was performed in terms of the comfortable visual environment and decreased energy consumption. The office building prototype was considered for the analysis and simulation variables include application of blind, blind slat angle and dimming control of lighting. The annual energy consumption and incidence rate of discomfort glare were analyzed using EnergyPlus which is developed by the U. S. Department of Energy for the detailed building energy simulation. As a result, it turns out that when the blind (reflectance: 0.5) was installed, the annual energy consumption was greater than that of the base model. However, when the dimming control was applied, the maximum energy saving of 16.3% could be achieved at a slat angle of $0^{\circ}$. In addition, in case of the base model, the incidence rate of discomfort glare was 84%, while the case of the blind with the slat angle of $0^{\circ}$ showed that the incidence rate of discomfort glare was 42.4%. Consequently, the results showed that the slat angle of $55^{\circ}$ with dimming control was the optimum strategy for the comfortable visual environment and decreased energy consumption.

염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구 (A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance)

  • 오명환;심세라;이철성;진경일;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

초.중 고등학교 교실의 빛환경 실측 연구 (An Experimental Study on the Interior Visual Environment of Classrooms in the Existing School Buildings)

  • 임상훈;천원기;오정무;이남호
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.3-14
    • /
    • 1992
  • 종래 북측 복도 남측 교실 학교 건물에서는 교실내에서 칠판에서 뿐만 아니라 남측과 북측 책상 위에서의 조도 불균형 및 현휘 등이 현저하여 이로 인하여 바람직한 교수 학습에 지장을 초래하고 있다. 따라서 본고에서는 초 중 고등학교 교실에 있어서 빛 환경에 대한 제반 문제점을 검토하고, 이에 대한 개선안을 제시하였다.

  • PDF

재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략 (Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance)

  • 오명환;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF

Lightscape를 이용한 광선반의 시뮬레이션 평가 연구 (A Study on the Computer Simulation Estimate of Light Shelf Using Lightscape)

  • 조일식;김기세;윤종호;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.93-102
    • /
    • 2003
  • One of the promising optical daylighting systems is light shelf type daylighting system, Two types of lighting performance analysis methods are 1) Ray-Tracing method and 2) Radiosity method. The purpose of this paper is to compare two methods in terms of advantages and disadvantages by further looking at the detail algorithm. Also. model verification with Lightscape simulations has been conducted. Effectiveness of light penetration factor in terms of daylighting factor has been investigated and quantified. In summer time. the performance of the light shelf was twice better than the case without it.

박물관의 조명 각도와 관람객 눈높이에 따른 불쾌적 현휘 분석 (Analysis of Discomfort Glare by Visitors' Eye-level and Illumination Angles in Museum)

  • 이영웅;김상현;조성은;강유진;김수민
    • 한국가구학회지
    • /
    • 제26권4호
    • /
    • pp.328-333
    • /
    • 2015
  • The museum is a important place to inform the value of various antiquities and relics. The museum, founded in domestic, were increased 90% in 2013 compared to 2006, and total number of including private museums were increased more than three times over the past decade. There are installing a variety of illumination and air-conditioning system, such as the spot lighting of exhibition explanation. But the exhibition explanation should not happen to visual perception disabilities by lighting. According to ICOM (International Council of Museum), it is stipulating that the museum should not to occur glare. However, we confirmed some occurred the glare and it was lack of previous studies about prevention plan. In this study, we verified occurrence of the glare by illumination angles and visitor's eye-level. The luminance values were determined by using DSLR camera and illuminometer. As a result, when illumination angle is 90 degree, the glare did not occurred by the luminance value ratio of over 0.167 regardless of eye-level. By contrast, the angle 30 degree was appeared glare with all level. And this study was compared luminance values that obtained through experiment and surveying.