• Title/Summary/Keyword: 현장압축강도

Search Result 535, Processing Time 0.027 seconds

Long-Term Compressive Strength and Durability Properties of "CSG" Materials by Freezing-Thawing Test (동결융해시험에 의한 "CSG" 재료의 장기강도 및 내구 특성)

  • Jin, Guangri;Kim, Kiyoung;Moon, Hongduk;Quan, Hechun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.12
    • /
    • pp.35-43
    • /
    • 2016
  • With the development of construction technology, constructions of dam and levee (dike) as well as the environmental problems are becoming issues. Recently, many countries have tried to develop and used CSG (Cemented Sand and Gravel), which needs fewer requirements than others in aggregates, constructability and ground condition during the dam construction. Mixing up with small amount of cement, CSG is able to increase the strength and proceed accelerated construction without artificial gradation adjustment of riverbed aggregate and crushed rock on construction site. Thus, CSG can minimize environmental damage resulted from quarries mining and reduce cost of construction. Unlike heat of hydration condition that regular concrete usually met, CSG exposes to repeated dry-wet and freezing and thawing environment. Thus, consider the importance of structure of dam or levee, intensive study on the durability of CSG is needed. In this study, freezing and thawing experiment was carried out to evaluate the durability of CSG. In results, the durability factor of CSG is 30~40 or >40 when the amount of cement is $0.4{\sim}0.6kN/m^3$ or $0.8{\sim}1.0kN/m^3$, respectively. The unconfined compressive strength is reduced to 30~50% or 40~70% when the amount of cement is $0.4{\sim}0.6kN/m^3$ or $0.8{\sim}1.0kN/m^3$, respectively. Taken together, the strength and durability of CSG is reliable when the amount of cement is over $0.8kN/m^3$.

Estimation of Soft Ground Piezocone Factors at Gwangyang, Jeonnam (전남 광양지역 연약지반의 피에조콘계수 산정)

  • Oh, Dongchoon;Kim, Kibeom;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.2
    • /
    • pp.59-67
    • /
    • 2019
  • Using the results from laboratory soil test, field vane test and piezocone penetration test, the engineering characteristics of the soft ground at east side of Gwangyang Port, which is located at south coast of Jeollanam-do, were investigated and optimal piezocone penetration test depth was derived to calculate piezocone factor. In this paper, the results of 61 laboratory soil tests, 226 times of field vane tests and 26 piezocone penetration tests were used. The result of laboratory soil test suggested that some physical properties such as specific gravity, moisture content, liquid limit and plastic index and others are higher than other south coast regions, meanwhile uniaxial compression strength, undrained shear strength, defined as mechanical property, appeared to be relatively small, distributed widely. According to the plastic chart, the ground was classified as high compressibility clay and low compressibility clay, mostly represent to Type 3 clay by Robertson (1990)'s classification chart. Piezocone factor was calculated by empirical method, based on the undrained shear strength which was obtained by the field vane test. According to the analysis with 3 different depth range, to set the appropriate measured depth range of piezocone penetration for comparation, using average value of the range of 5 times the vane length showed the highest correlation.

Empirical Rock Strength Logging in Boreholes Penetrating Sedimentary Formations (퇴적암에 대한 경험적 암석강도 추정에 대한 고찰)

  • Chang, Chan-Dong
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.174-183
    • /
    • 2004
  • The knowledge of rock strength is important in assessing wellbore stability problems, effective sanding, and the estimation of in situ stress field. Numerous empirical equations that relate unconfined compressive strength of sedimentary rocks (sandstone, shale, and limestone, and dolomite) to physical properties (such as velocity, elastic modulus, and porosity) are collected and reviewed. These equations can be used to estimate rock strength from parameters measurable with geophysical well logs. Their ability to fit laboratory-measured strength and physical property data that were compiled from the literature is reviewed. While some equations work reasonably well (for example, some strength-porosity relationships for sandstone and shale), rock strength variations with individual physical property measurements scatter considerably, indicating that most of the empirical equations are not sufficiently generic to fit all the data published on rock strength and physical properties. This emphasizes the importance of local calibration before one utilizes any of the empirical relationships presented. Nonetheless, some reasonable correlations can be found between geophysical properties and rock strength that can be useful for applications related to wellhole stability where haying a lower bound estimate of in situ rock strength is especially useful.

Suggestion of Charts and Equations Estimating the Strength Parameters of Rock Mass Using the Rock Mass Classification Value (RMC 값을 이용한 암반의 강도정수 값 추정도표 및 추정식의 제안)

  • Kim, Min-Kwon;Lee, Yeong-Saeng
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.3
    • /
    • pp.73-85
    • /
    • 2014
  • The strength parameters used in rock mass design are mainly estimated by equations using Hoek-Brown failure criterion because the tests to obtain the values are limited and expensive. To estimate the strength parameters, the Hoek-Brown failure criterion should be transformed to the Mohr-Coulomb failure criterion. But the processes are more or less cumbersome due to the several stages including the computation and the analyzing steps. In this study, several rock states of various conditions were modeled and then the strength parameters were estimated using the Hoek-Brown failure criterion. Thereafter by analyzing the results, some charts and equations estimating the strength parameters through only one step or easily in the field using the values of RMC, the uniaxial compressive strength and the rock constant ($m_i$), were suggested. And then the suggested method was compared and discussed with the existing method.

A study for the performance evaluation of concrete block assembly wall without using mortar (무모르타르로 건식조립된 콘크리트블록 벽체의 성능평가 연구)

  • Lee, Joong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.203-210
    • /
    • 2019
  • A recent earthquake on the Korean Peninsula caused much damage to masonry buildings, and research on performance evaluation has been underway. A masonry building is generally constructed using wet construction and is affected by temperature, which reduces the efficiency of the construction. In this study, we propose a dry construction technique for assembling concrete blocks without using mortar and evaluated its performance through experimental and analytical research. To evaluate the performance, experiments were carried out for the prismatic compressive strength, direct terminal strength, and diagonal tensile strength of the dry construction wall. The adequacy of the cross section shape was also reviewed through FEM analysis. The results show that the compressive strength and diagonal tensile strength could exert a certain intensity or higher. Furthermore, the H-type module of a key block acted as a shear key for the entire concrete block, which resulted in excellent shear strength performance. In addition, the shape and thickness of the main block have a major effect on the strength performance of each block. Therefore, an optimal shape and the proposed dry construction method could be applied to replace the wet method by studying the construction or seismic performance of the proposed method.

Interface Shear Strength in Half Precast Concrete Slab (반두께 P.C. 슬래브의 면내전단내력에 관한 연구)

  • 이광수;김대근;최종수;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.4
    • /
    • pp.161-168
    • /
    • 1994
  • Half-P.C. slab system is the composite structural system which utilizes precast concrete for lower portion and cast in situ concrete for upper portion slab. When the composite slab using Half P.C. slab is deformed by flexural moment, horizontal shear happened at the interface between Half P.C. slab and topping concrete. To resist horizontal shear strength a scratch method has tried. To determine ultimate interface shear strength, shear stress, and shear coefficient, high and normal strength concrete are used for topping concrete. Major variables are compressive strength of topping concrete with or without shear reinforcement, quantitative roughness of the P.C. :surface and tie or untie of the stud with welded deformed wire fabric in the P.C. member. The Icross sectional area on joints is 3,200 $cm^2$ in all specimens. Test results showed that shear stress increased, as the depth of the quantitative roughness increased. The horizontal shear strength could be resisted with safe by the quantitative roughness without shear tie. A shear coefficient determinant equation is proposed such that K = 0.025918 + 0.0068894$\cdot$R – 0.000182354${\cdot}R^2$

Modeling on Ultrasonic Velocity in Concrete Considering Micro Pore Structure and Loading Conditions (공극구조 및 하중조건에 따른 콘크리트의 초음파 속도 모델링)

  • Kim, Yun Yong;Oh, Kwang-Chin;Park, Ki-Tae;Kwon, Seung-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.415-426
    • /
    • 2015
  • For a long time, evaluation of soundness and strength in concrete has been performed through ultrasonic velocity(UV), which is essential work in field assessment. Porosity in concrete is a major parameter indicating durability and strength, and UV passing concrete depends on porosity variation. In this paper, a modeling on UV through concrete is carried out considering porosity and the results are verified with those from test. Additionally UV in concrete under compression/tension loading condition is measured and UV modeling with loading condition is performed. Up to 50% of loading ratio, UV slightly increases and greatly drops at peak load in compression region, however it fluctuates in tensile region due to micro cracking in matrix. The proposed model shows a reasonable agreement with test results in control and compression region, and needs modification for tensile region considering micro cracks and local aggregate interlocking.

Development of Torsional Shear Testing System to Measure P-wave Velocity, S-wave Velocity and Pore Water Pressure Buildup on Fully and Partially Saturated Sands (포화 및 부분 포화 사질토의 Vp와 Vs 속도 및 과잉간극수압 측정을 위한 비틂전단 시험기의 개발)

  • Kim, Dong-Soo;Lee, Sei-Hyun;Choo, Yun-Wook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.1
    • /
    • pp.55-66
    • /
    • 2006
  • Laboratory tests have revealed that the liquefaction resistance of sands depends strongly upon the degree of saturation, which is expressed in terms of the pore pressure coefficient, B. The velocity of compression waves(i.e. P-waves), which have been known to be influenced largely by the degree of saturation and can be measured conveniently in the field, appears as an indicator of saturation. In this paper, the Stokoe type torsional shear(TS) testing equipment is modified to saturate the specimen and measure the velocities of P-wave and S-wave and pore pressure buildup. The velocities of P-wave and S-wave for Toyoura sand from Japan is measured and compared at the various B-value (degree of saturation) which are partially saturated to fully saturated conditions. Additionally, the variation of the pore water pressure induced during undrained TS tests at the various B-value is measured and analyzed.

  • PDF

The Physical Properties Variation of Grout Materials and Improvement of Grouting Effects on Application of High Performance Injection Equipment (고성능 주입장비의 적용에 따른 주입재의 물성변화 및 주입효과 증진에 관한 연구)

  • 천병식;김진춘;김백영
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.179-190
    • /
    • 2003
  • The grout based on solution type makes it difficult to get the improvement of ground strength and the effefct of water curtain because it has lower strength and durability than suspension type. Nowadays, the technology of particle acceleration, that enhance the material permeability, such as grout based on solution type, and inexpensive grout, is being required. For these reasons, in this study, using wet milling system, we evaluated physical properties of manufactured factors such as water-cement ratio of particles before being milled, optimum milling capacity by controlling milling time and rpm, viscosity of materials, permeation coefficient, and unconfined compressive strength. Also, using micro wet milling apparatus which could manufacture ordinary Portland cement and high speed shear mix which could forcefully separate conglomerate particles in situ, we performed electrical resistivity investigation and falling head permeability tests to analyze differences of grouting effects. From these results, we found that the permeability of the applied equipment was much superior, and in the case of using high speed shear mixer, particles of grout material were well separated.

Properties and Field Application of Non-shrinkage High Strength Concrete (무수축 고강도 콘크리트의 특성 및 현장적용)

  • 조일호;성찬용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.6
    • /
    • pp.115-121
    • /
    • 2000
  • The purpose of this research is to investigate properties and field application of non-shrinkage high strength concrete containing expansive additive. Before the field applications, several basic laboratory test are performed to evaluate the characteristics of air content, workability and strength of the concrete using calcium sulfa aluminate(CSA) expansive additive. As a result, high strength concrete using CSA expansive additive show similar workability and compressive strength to that normal concrete, and the optimum replacement ratio of them is obtained by 10% CSA expansive additive. Accordingly, it can be concluded that the use of CSA expansive additive is effective to prevent shrinkage crack and to achieve volume stability of concrete structure.

  • PDF