• Title/Summary/Keyword: 현장실험기법

Search Result 479, Processing Time 0.031 seconds

New Gain Function Based on Attenuation Characteristics of Ballast Track for GPR Analysis (GPR 분석을 위한 자갈궤도 자갈의 감쇄특성을 이용한 이득함수 개발)

  • Shin, Jihoon;Choi, Yeongtae;Jang, SeungYup
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.4
    • /
    • pp.13-21
    • /
    • 2017
  • Ballasted track has been used as track system for more than 100 years. Ballasted track has advantages of low construction cost, flexible maintenance, low noise and vibration, and so on. However, ballasted track leads to continuous settlement which causes maintenance. Recently, increase in speed, traffic volume, and weight of train requires more frequent maintenance. Fouling, well-known phenomenon of accumulation of fine materials due to intrusion of subgrade and breakage of ballast materials, expedites the settlement (i.e., irregular settlement) of track. Ground Penetrating Radar (GPR) can be one of non-destructive tools that can evaluate fouling level of ballast. In this paper, a gain function based on the attenuation characteristics of ballast material is suggested in conjunction with Hilbert transform. Lab box tests and full-scale tests indicate that the suggested method reasonably classifies clean, fouled layers, and subgrade. However, additional study to eliminate effect of sleeper and to include the scattering features of the electromagnetic wave in ballast voids should be required in order to enhance the accuracy.

Comparison of PI and PR Controller Based Current Control Schemes for Single-Phase Grid-Connected PV Inverter (단상 계통 연계형 태양광 인버터에 사용되는 PI 와 PR 전류제어기의 비교 분석)

  • Vu, Trung-Kien;Seong, Se-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2968-2974
    • /
    • 2010
  • Nowadays, the PV systems have been focused on the grid connection between the power source and the grid. The PV inverter can be considered as the core of the whole system because of an important role in the grid-interfacing operation. An important issue in the inverter control is the load current regulation. In the literature, Proportional Integral (PI) controller, which is normally used in the current-controlled Voltage Source Inverter (VSI), cannot be a satisfactory controller for an AC system because of the steady-sate error and the poor disturbance rejection, especially in high-frequency range. Compared with conventional PI controller, Proportional Resonant (PR) controller can introduce an infinite gain at the fundamental frequency of the AC source; hence it can achieve the zero steady-state error without requiring the complex transformation and the de-coupling technique. Theoretical analyses of both PI and PR controller are presented and verified by simulation and experiment. Both controller are implemented in a 32-bit fixed-point TMS320F2812 DSP processor and evaluated on a 3kW experimental prototype PV Power Conditioning System (PCS). Simulation and experimental results are shown to verify the controller performances.

Development and Validation of Inner Environment Prediction Model for Glass Greenhouse using CFD (CFD를 이용한 유리온실 내부 환경 예측 모델 개발 및 검증)

  • Jeong, In Seon;Lee, Chung Geon;Cho, La Hoon;Park, Sun Yong;Kim, Min Jun;Kim, Seok Jun;Kim, Dae Hyun
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.285-292
    • /
    • 2020
  • Because the inner environment of greenhouse has a direct impact on crop production, many studies have been performed to develop technologies for controlling the environment in the greenhouse. However, it is difficult to apply the technology developed to all greenhouses because those studies were conducted through empirical experiments in specific greenhouses. It takes a lot of time and cost to develop the models that can be applicable to all greenhouse in real situation. Therefore studies are underway to solve this problem using computer-based simulation techniques. In this study, a model was developed to predict the inner environment of glass greenhouse using CFD simulation method. The developed model was validated using primary and secondary heating experiment and daytime greenhouse inner temperature data. As a result of comparing the measured and predicted value, the mean temperature and uniformity were 2.62℃ and 2.92%p higher in the predicted value, respectively. R2 was 0.9628, confirming that the measured and the predicted values showed similar tendency. In the future, the model needs to improve by applying the shape of the greenhouse and the position of the inner heat exchanger for efficient thermal energy management of the greenhouse.

Experimental Study of Characteristics of Longitudinal Resistance Behavior of Fasteners in Concrete Track on Bridges (교량 상 콘크리트궤도 체결장치의 종저항 거동특성에 대한 실험적 연구)

  • Yun, Kyung-Min;Park, Beom-Ho;Min, Kyung-Hwan;Lim, Nam-Hyoung
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.5
    • /
    • pp.638-646
    • /
    • 2016
  • CWR (continuous welded rail) tracks on high-speed railway bridges have much more complicated axial force distributions caused by track-bridge interaction than those behaviors on embankments, and additional problems caused by track-structure interaction with the axial force of the CWR. In order to analyze and limit other physical phenomena caused by track-bridge interaction, a design guideline (KR C-08080, longitudinal track-bridge interaction analysis) is used when designing CWR track on bridges. Domestic analysis and design methods for track-bridge interaction follow the UIC 774-3R, and they suggest conservative methods and deterministic properties. Recently, many studies analyzing the methods of track-bridge interaction considering the loading history are being carried out; however, there has been insufficient studies of the variation of the resistance properties with a consideration of the actual loading history. In this study, the performances of rail fastening systems used for concrete track on bridges were tested and analyzed while considering the loading history. For this purpose, longitudinal and vertical loading combinations, applied in order to simulate the practical conditions and resistance characteristics (stiffness and elastic limit displacement), are analyzed through the experimental results. Also, a comparison study was conducted with the properties in the KR Code.

Development of Buried Type TDR Module for Leak Detection from Buried Pipe (매설관 주변부 누수 탐지를 위한 매설형 TDR 모듈 개발)

  • Hong, Wontaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.11
    • /
    • pp.31-37
    • /
    • 2021
  • To prevent accidents due to the cavities and loosened layers formed due to water leakage from the deteriorated buried pipes, evaluation of the changes in water contents around the buried pipes is required. As a method to evaluate the water contents of the soils, time domain reflectometry (TDR) system can be adopted. However, slender electrodes used in standard TDR probe may be damaged when buried in the ground. Thus, in this study, buried type TDR module was developed for the evaluation of the water contents with maintaining required shape of the electrodes in the ground. The TDR module is composed of three electrodes connected to the core conductor and outer conductor and a casing to prevent deformation and maintain alignment of the electrodes in the ground. For the verification of TDR waveforms measured using the TDR module, comparative analysis was conducted with the TDR waveforms measured using the standard TDR probe, and the relationship between the volumetric water content of the soils and the travel time of the guided electromagnetic wave was constructed. In addition, a model test was conducted to test the applicability of the buried type TDR module, and the experimental result shows that the TDR module clearly evaluates the changes in volumetric water contents due to the leakage from the modeled buried pipe. Therefore, the buried type TDR module may be effectively used for the health monitoring of the buried pipe and the evaluation of the water contents around the pipes buried in the urban pavements.

Revalidation of the Complex Trial Protocol using participant-oriented countermeasures (설문 기반 대응방안을 사용한 복합시행 프로토콜의 재평가)

  • Kim, Hyemin;Song, Inuk;Chang, Eunhee;Kim, Hyun Taek
    • Korean Journal of Forensic Psychology
    • /
    • v.11 no.1
    • /
    • pp.89-115
    • /
    • 2020
  • Traditional deception detection methods had examined the difference of one's autonomic physiological responses through asking crime-related and crime-unrelated questions. There has been a continuing controversy regarding the accuracy and validity of the test, and thus, many researchers were motivated to explore and develop alternative efficient methods of detection in which one of them is known as P300-based Complex Trial Protocol (CTP). The P300-based CTP detects deception through comparing the P300 amplitudes between probe and irrelevant stimuli and is known as a counterstrategy of countermeasures. However, many previous studies have used countermeasures created from Rosenfeld et al.'s work (2008). The present study initially conducted a survey asking open-ended questions about the countermeasure use to acquire participant-oriented countermeasures for the main experiment. Then, the study aimed to evaluate whether the CTP can accurately detect deception even in the use of survey-based countermeasures. We firstly selected a set of participant-oriented countermeasures through survey questions. Then, a total of 50 participants were divided into three groups (innocent, guilty, and countermeasures) and performed the CTP. Those assigned to the countermeasures group covertly performed mental countermeasures during the CTP. The results of P300 amplitude analysis revealed that the guilty group's P300 amplitude of probe stimuli was significantly larger than that of irrelevant stimuli. Countermeasures group also had a significantly larger P300 amplitude for probe stimuli compared to irrelevant stimuli, even in the use of countermeasures. The results of bootstrapped amplitude difference (BAD) showed a detection accuracy rate of 81.25%, 82.35%, 82.35% for the innocent, guilty, and countermeasures groups, respectively. These findings demonstrate that the CTP can obtain a high detection rate in participant-oriented countermeasures and suggest the potential use of the CTP in the field.

  • PDF

Oxidative Degradation of PCE/TCE Using $KMnO_4$ in Aqueous Solutions under Steady Flow Conditions (유동조건에서 $KMnO_4$도입에 따른 수용액중 PCE/TCE의 산화분해)

  • Kim, Heon-Ki;Kim, Tae-Yun
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.685-693
    • /
    • 2008
  • The rates of oxidative degradation of perchloroethene (PCE) and trichloroethene (TCE) using $KMnO_4$ solution were evaluated under the flow condition using a bench-scale transport experimental setup. Parameters which are considered to affect the reaction rates tested in this study were the contact time (or retention time), and the concentration of oxidizing agent. A glass column packed with coarse sand was used for simulating the aquifer condition. Contact time between reactants was controlled by changing the flow rate of the solution through the column. The inflow concentrations of PCE and TCE were controlled constant within the range of $0.11{\sim}0.21\;mM$ and $1.3{\sim}1.5\;mM$, respectively. And the contact time was $14{\sim}125$ min for PCE and $15{\sim}36$ min for TCE. The $KMnO_4$ concentration was controlled constant during experiment in the range of $0.6{\sim}2.5\;mM$. It was found that the reduction of PCE and TCE concentrations were inversely proportional to the contact time. The exact reaction order for the PCE and TCE degradation reaction could not be determined under the experimental condition used in this study. However, the estimated reaction rate constants assuming pseudo-1st order reaction agree with those reported based on batch studies. TCE degradation rate was proportional to $KMnO_4$ concentration. This was considered to be the result of using high inflow concentrations of reactant, which might be the case at the vicinity of the source zones in aquifer. The results of this study, performed using a dynamic flow system, are expected to provide useful information for designing and implementing a field scale oxidative removal process for PCE/TCE-contaminated sites.

Removal Effects of Chlorophyll-a and Cyanobacteria Using Laboratory-scale Biomanipulation Tests (실험적 생물조절 기법을 이용한 엽록소 및 남조류 제거 효과)

  • Lee, Sang-Jae;Lee, Jae-Yon;Lee, Jae-Hoon;Bae, Dae-Yeul;Lee, Eui-Hang;Han, Jung-Ho;Hwang, Soon-Jin;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.spc
    • /
    • pp.86-92
    • /
    • 2008
  • This study was conducted to determine removal effect on phytoplankton (chlorophyll-${\alpha}$ as whole algae) and cyanobacteria by a fish Pseudorasbora parva and macroinvertebrate Palaemon paucidens in September 2006. Three treatments with 25 (T1), 50 (T2) and 100 (T3) individuals along with control (C1, no input fish), and two treatments with 25 (T4) and 50 (T5) individuals along with control (C1) were made for fish and macroinvertebrate, respectively. The initial concentrations of chlorophyll-${\alpha}$ $(Chl_i)$ in each 10L test tank were set up for the levels of $95{\sim}100{\mu}g\;L^{-1}$ and the daily values were monitored in the test tank during 7 days. In the lab tests, P. parva did not show Chl-${alpha}$ removal effect; the removal rate of Chl-${alpha}$ for P. parva was -58% in T1, -56% in T2, and 61% in T3 during the test period. In contrast, P. paucidens. in the treatments of T4 and T5 removed the phytoplankton effectively and the removal effect were appeared to be 33% and 22%, respectively. Also, P. paucidens showed high feeding efficiency in the removal of cyanobacteria. The levels of cyanobacteria were greatly lowed from 6,048 to 927 cells $mL^{-1}$ in T4 and from 6,539 to 1,053 cells $mL^{-1}$ in T5, resulting in 85% and 84% in the removal effect, respectively. Our results for biomanipulation tests suggest that P. paucidens may be used as a potential candidate organism for algae control in spite of the preliminary results by laboratory tests.

GPR Development for Landmine Detection (지뢰탐지를 위한 GPR 시스템의 개발)

  • Sato, Motoyuki;Fujiwara, Jun;Feng, Xuan;Zhou, Zheng-Shu;Kobayashi, Takao
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.4
    • /
    • pp.270-279
    • /
    • 2005
  • Under the research project supported by Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT), we have conducted the development of GPR systems for landmine detection. Until 2005, we have finished development of two prototype GPR systems, namely ALIS (Advanced Landmine Imaging System) and SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar). ALIS is a novel landmine detection sensor system combined with a metal detector and GPR. This is a hand-held equipment, which has a sensor position tracking system, and can visualize the sensor output in real time. In order to achieve the sensor tracking system, ALIS needs only one CCD camera attached on the sensor handle. The CCD image is superimposed with the GPR and metal detector signal, and the detection and identification of buried targets is quite easy and reliable. Field evaluation test of ALIS was conducted in December 2004 in Afghanistan, and we demonstrated that it can detect buried antipersonnel landmines, and can also discriminate metal fragments from landmines. SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar) is a machine mounted sensor system composed of B GPR and a metal detector. The GPR employs an array antenna for advanced signal processing for better subsurface imaging. SAR-GPR combined with synthetic aperture radar algorithm, can suppress clutter and can image buried objects in strongly inhomogeneous material. SAR-GPR is a stepped frequency radar system, whose RF component is a newly developed compact vector network analyzers. The size of the system is 30cm x 30cm x 30 cm, composed from six Vivaldi antennas and three vector network analyzers. The weight of the system is 17 kg, and it can be mounted on a robotic arm on a small unmanned vehicle. The field test of this system was carried out in March 2005 in Japan.

Influences of a Sound Design of Media Contents on Communication Effects - TV-CF Sound Using a BQ-TEST (영상음향의 사운드디자인설계가 커뮤니케이션 효과에 미치는 영향 - TV광고음향을 뇌 지수 분석기법으로 -)

  • Yoo, Whoi-Jong;Suh, Hyun-Ju;Moon, Nam-Mee
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.602-611
    • /
    • 2008
  • The sound design performed in the production of media contents, such as TV, movie, and CF, have been conducted through the experienced feeling of some experts in the aspect of auditory effects that communicates stories. Also, there have been few studies of the quantitative approach and verification to apply visual and auditory effects felt by users. This study is a non-equivalent control group pretest-posttest design and investigates the difference in communication effects in which the difference in a sound design in the production of media contents that affects users. This study analyzed the brain quotient (BQ) obtained by the measurement of brain waves during the watching of an experiment image (track A) designed by using a 60-second TV CF only and an experiment image (track B) designed by sound effects and music and investigated which sound design represents differences in communication effects for users. The results of this investigation can be summarized as follows: First, in the results of the comparison of the attention quotient (ATQ), which is the BQ of recognition effects, between A and B tracks, the track A showed a higher difference in activation than the track B. It can be analyzed that the sound design based on music showed higher levels in attention and concentration than that of the sound effect design. Second, in the results of the comparison of the emotional quotient (EQ), which is emotional effects, between A and B tracks, the track A represented a higher difference than the track B. It means that the sound design based on music showed higher contribution levels in emotional effects than that of the design based on sound effects. Third, in the results of the comparison of the left and right brain equivalent quotient (ACQ), which is memory activation effects, between A and B tracks, there were no significant differences. In the results of the experiments, although there are some constraints in TV CF based on the conventional theories in which sound effects based design affects strong concentration, and music based design affects emotional feeling, the music based design may present more effects in continued concentration. In addition, it was evident that the music based design showed higher effects in emotional aspects. However, it is necessary to continue the study by increasing the number of subjects for improving the little differences in ACQ. This study is useful to investigate the communication effects of the sound based design in media contents as a quantitative manner through measuring brain waves and expect the results of this study as the basic materials in the fields of sound production.