• Title/Summary/Keyword: 헬륨네온 레이저

Search Result 27, Processing Time 0.021 seconds

Offset Frequency Stabilization of He-Ne Lasers Using Phase Locked Loop (PLL을 이용한 헬륨-네온 레이저의 옵셋 주파수 안정화)

  • Yun Dong Hyun;Suh Ho Sung;Lyou Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.6
    • /
    • pp.496-501
    • /
    • 2005
  • This paper presents experimental results of the frequency offset locking of He-Ne lasers and the stability analysis. The master laser is free running, and the slave laser is a single-mode operating laser. The frequency difference of two lasers is stabilized to 200 MHz which can be synchronized using PLL servo. The measured beat frequency between two lasers was 200.004 MHz ${\pm}$ 0.15 MHz. The square root of Allan variance as a measure of stability in time domain is also measured. The long-term stability of the beat was worse than sort-term stability. With a gate time $\tau=1000\;s$, the square root of Allan variance was about 1 GHz. The results of the square root of Allan variance of the stabilized beat signal was a gate time of $\tau=1000\;s$, the square root of Allan variance was about 1.5 kHz. The long-term stability was improved by more than several hundred times compared with that without the stabilization.

Synthesis of an On-Line 5 Degrees of Freedom Error Measurement System for Translational Motion Rigid Bodies (병진운동 강체의 온라인 5자유도 운동오차 측정시스템 설계 및 해석)

  • 김진상;정성종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.93-99
    • /
    • 1998
  • Although laser interferometer measurement system has advantages of measurement range and accuracy, it has some disadvantages when measurement of multi degrees of freedom of motion are required. Because the traditional error measurement methods for geometric errors (two straightness and three angular errors) of a slide of machine tools measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric errors of a moving rigid body in real time processes, an on-line error measurement system for simultaneous detection of the five error components of a moving object is required. Using laser alignment technique and some optoelectronic components, an on-line measurement system with 5 degrees of freedom was developed for the geometric error detection in this study Performance verification of the system has been performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a slide of machine tools.

  • PDF

Naloxone Reversal of He-Ne Laser Stimulation Induced Analgesia in Rat (헬륨 -네온 레이저자극으로 유발된 흰쥐 진통작용의 날록손 반전)

  • Lee Jae-Hyoung;Song In-Yong;Choi Eun-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.8 no.1
    • /
    • pp.15-20
    • /
    • 1996
  • The purpose of this study were to 1) determine the analgesic effect of 632.8 nm of helium-neon (He-Ne) laser stimulation on acupuncture point in rat and 2) determine the reversal of analgesic effect by naloxone injection. Eighteen Sprague-Dawley rats were devided into three groups : control (n=6) : laser (n=6), laser stimulation at $3.58\;J/cm^2$ ; and naloxone (n=6), 1 mg/kg of naloxone chloride inject into peritoneum before laser stimulation at $3.63J/cm^2$. Tail-flick latency were measured pretreat and posttreat with hot plate $(55^{\circ}C)$. Data were analyzed using one-way ANOVA and paired t-teat for tail-flick latency. No significant change was noted in the tail-flick latency in either control or naloxone groups. But significant increased in tail-flick latency in taller group. The results suggest that He-Ne laser induced analgesic effect, and endogenous opioids may be involved in He-Ne laser induced analgesia.

  • PDF

A study of the hologram which records the interference of light with computer (컴퓨터로 빛의 간섭을 기록하는 홀로그램(CGH)의 특성 연구)

  • Lee, Jeong-Yeong;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.305-312
    • /
    • 2005
  • In this thesis, Lohmann's algorithm and FFT (fast Fourier transform) are used to synthesize binary-phase holograms. FFT computing is carried out for the calculation of complex wavefronts of $128{\times}128$ sampling points of an object that is numerically specified. Then using the Lohmann's algorithm, the amplitude and the phase of complex wavefronts are encoded in binary holograms on each sampling points. PC (personal computer) and laser printer are used to plot binary-phase holograms and CGH (computer generated holograms) films are obtained from this plot by photographic reduction. Holographic images of numerically specified objects are reconstructed from the He-Ne laser and the inverse Fourier optics system. We estimate the quality of holographic images according to the sampling number, application of random phase, amplitude clipping and bleaching the CGH film. We derive optimized conditions to reconstruct better holographic images and to reduce the speckle noise. FFT and Lohmann's algorithm are implemented with MS Visual BASIC 6.0 for the programming of binary-phase hologram.

  • PDF

An Undergraduate Level Polarimeter and Specific Rotation at 543 nm of Sucrose (학부용 편광계와 543 nm에서 설탕의 비회전 측정)

  • Jung, Semin
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.6
    • /
    • pp.241-245
    • /
    • 2012
  • Measurements of the optical activity become very important issues in fields related to polymers, optical communications, astronomy, physics and many more. Hence it need to introduce this subject in our regular curriculum. In this experiment, an inexpensive, reliable, motorized polarimeter system which is suitable for undergraduate courses is constructed with PASCO's well-known Science Workshop 750 and a rotational motion sensor and light sensor, and the system is presented along with its experimental formulas. After responsivity of this system was checked by a half wave plate, and some repetitive experiments with 30% sucrose solution at 543.8 nm were performed. Comparing the experimental result with two calculated values from CRC data[1] showed that the specific rotation of the sucrose sample could be strongly suggested to be around +76 deg.cc/g.dm and it was an amply acceptable result for most undergraduate level courses.

Effect of the Incident Optical Spot Size Upon the Quadrant Photodetector on the Optical Displacement Detection Sensitivity (4분할 광 검출기 상의 광점 크기가 변위 측정감도에 미치는 영향)

  • Lee, Eun-Joong;Lee, Jin-Woo;Kouh, Tae-Joon
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.2
    • /
    • pp.71-74
    • /
    • 2008
  • In this paper, we have measured the effect of the optical spot size, incident upon the quadrant photodetector, on the optical displacement sensitivity of the optical beam deflection technique. We have built an optical displacement detection system based on the optical beam deflection method using 3 mW He-Ne laser and measured the displacement sensitivity with changing the optical spot size on the quadrant photodetector. We have also calculated the changes in the optical displacement sensitivity as a function of the incident laser spot size by modeling a circular optical spot with constant laser intensity. Our experimental and theoretical studies show that the optical displacement sensitivity increases with the decrease in the optical spot size. This suggests that in the design of the optical motion detection systems with sub-nanometer sensitivity, the displacement sensitivity can be optimized by reducing the size of the incident optical spot on the detector.

Effects of Intravenous He-Ne Laser Irradi on Meridian-Heart·Circulation CMP and Hyperlipidemia (정맥혈관내(靜脈血管內) 헬륨-네온 레이저 조사(照射)가 메리디안 심(心)·순환(循環) 대표점(代表點)과 고지혈증(高脂血症)에 미치는 영향(影響))

  • Ahn, Soo-gi;Lee, Sam-ro;Hwang, Woo-jun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.269-284
    • /
    • 1998
  • The purpose of this study was to investigate the effect of ILIB(Intravenous Laser Irradiation of blood) on Meridian-Heart Circulation CMP and Hyperlipidemia. Circulatory symptom of 20 patients was treated with ILIB. After 10 times' treatment, changes of total cholesterol, HDL-cholesterol, triglyceride and Meridian-Heart Circulation CMP value were observed. The results were as follows : 1. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both pre-ID generation and post-ID generation. So, distinctive observation between pre-ID generation and post-ID generation became not relatively significant. 2. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both left and right. So, distinctive observation between left and right became not relatively significant. 3. In observation of Meridian-Heart CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 4. In observation of Meridian-Circulation CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 5. In concentration of plasma total cholesterol and plasma triglyceride, significant decrease was not observed in control group, but significant increase was observed in treatment group after treatment of Intravenous He-Ne laser Irradiation. 6. Significant concentration change of plasma HDL-cholesterol was not observed in both control group and treatment group. From above results, it was thought that Intravenous He-Ne Laser Irradiation was significant effect on heart circulatory system in human body.

  • PDF