• Title/Summary/Keyword: 허용 기준

Search Result 1,694, Processing Time 0.03 seconds

Reliability-Based Design Optimization of 130m Class Fixed-Type Offshore Platform (신뢰성 기반 최적설계를 이용한 130m급 고정식 해양구조물 최적설계 개발)

  • Kim, Hyun-Seok;Kim, Hyun-Sung;Park, Byoungjae;Lee, Kangsu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.263-270
    • /
    • 2021
  • In this study, a reliability-based design optimization of a 130-m class fixed-type offshore platform, to be installed in the North Sea, was carried out, while considering environmental, material, and manufacturing uncertainties to enhance its structural safety and economic aspects. For the reliability analysis, and reliability-based design optimization of the structural integrity, unity check values (defined as the ratio between working and allowable stress, for axial, bending, and shear stresses), of the members of the offshore platform were considered as constraints. Weight of the supporting jacket structure was minimized to reduce the manufacturing cost of the offshore platform. Statistical characteristics of uncertainties were defined based on observed and measured data references. Reliability analysis and reliability-based design optimization of a jacket-type offshore structure were computationally burdensome due to the large number of members; therefore, we suggested a method for variable screening, based on the importance of their output responses, to reduce the dimension of the problem. Furthermore, a deterministic design optimization was carried out prior to the reliability-based design optimization, to improve overall computational efficiency. Finally, the optimal design obtained was compared with the conventional rule-based offshore platform design in terms of safety and cost.

Accuracy of Automatic Cephalometric Analysis Programs on Lateral Cephalograms of Preadolescent Children (소아 환자 대상의 자동 계측점 식별 프로그램의 정확성 평가)

  • Song, Min Sun;Kim, Seong-Oh;Kim, Ik-Hwan;Kang, Chung-min;Song, Je Seon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.3
    • /
    • pp.245-254
    • /
    • 2021
  • The aim of this study was to evaluate the accuracy of 3 different automatic landmark identification programs on lateral cephalgrams and the clinical acceptability in pediatric dentistry. Sixty digital cephalometric radiographs of 7 to 12 years old healthy children were randomly selected. Fourteen landmarks were chosen for assessment and the mean of 3 measurements of each landmark by a single examiner was defined as the baseline landmarks. The mean difference between an automatically identified landmark and the baseline landmark was measured for each landmark on each image. The total mean difference of 3 automatic programs compared to the baseline landmarks were 2.53 ± 1.63 mm. Errors among 3 programs were not significantly different for 12 of 14 landmarks except Orbitale and Gonion. The automatic landmark identification programs showed significant higher mean detection errors than the manual method. The programs couldn't be used as the 1st tool to replace human examiners. But considering short consuming time, these results indicate that all 3 programs have sufficient validity to be used in pediatric dental clinic.

A Critical Evaluation of the Moon Jae-In Administration's Policies on Non-standard Employment in the Public Sector of Korea (문재인 정부 1년 공공부문 비정규직 정책 평가: 정책 패러다임의 전환?)

  • Hwang, Sun-Oong
    • Korean Journal of Labor Studies
    • /
    • v.24 no.2
    • /
    • pp.29-59
    • /
    • 2018
  • This paper examines the achievements and limitations of the Moon Jae-In administration's first-year policies on non-standard employment in the public sector of Korea. The most remarkable achievement was that the transition rate of non-standard to standard positions reached the highest historical level of 42.1 percent, mainly by including for the first time temporary agency workers as a target of those policies. There also have been many steps taken to relax the qualification for transition, reduce the number of exception clauses, and expand union participation. In contrast, policy measures to address problems of low wages and inequality were very limited and not significantly different from those of previous administrations. As a result, the success of the policy paradigm shift pursued by Moon's administration will be determined by how aggressive measures are being taken in the next policy steps to improve such problems of low wages and inequality.

A New F1 Hybrid Variety of Rapeseed (Brassica napus L.), 'Jomang' with Early Maturation, High Yield and High Oleic Acid (조숙, 다수성, 올레인산 고함유 유채 신품종 '조망')

  • Kim, Kwang-Soo;Jang, Young-Seok;Lee, Yong-Hwa;Cho, Hyun-Jun;Bang, Jin-Ki;Suh, Sae-Jung
    • Korean Journal of Breeding Science
    • /
    • v.42 no.3
    • /
    • pp.236-240
    • /
    • 2010
  • 'Jomang' is a new $F_1$ hybrid variety of rapeseed (Brassica napus L.) with early maturation, high yield and high oleic acid. This hybrid variety was developed from the cross between Mokpo-CGMS (male sterile line) and 8516-B-5-6-5-3 (restore line) for the production of edible oil and biodiesel in 2006. Yield trials were conducted from 2007 to 2008, and regional adaptation trials were examined at four locations in 2008. 'Jomang' has green and parted leaf, yellowish flower and black seed coat. The ripening date of 'Jomang' is 1~4 days earlier than 'Sunmang' and 'Tammiyuchae'. The average seed yield of the regional adaptation trials was 406 kg/10a, which was 7% and 42% higher than those of 'Sunmang' and 'Tammiyuchae,' respectively. Total oil content of 'Jomang' was 44.5%. 'Jomang' has no erucic acid in fatty acid composition. However, oleic acid content is 68.2%, which is 3.4% and 5.1% higher than 'Tammiyuchae' and 'Sunmang,' respectively. Total glucosinolate content was 2.31 mg/g. Therefore, this variety is recommended as a leading variety at southwestern area including Jeonnam, Jeonbuk and Kyongnam provinces and Cheju island of Korea.

Ecotoxicity Assessment of 1,4-Dioxane and Dichloromethane in Industrial Effluent Using Daphnia magna (물벼룩을 이용한 산업방류수 중 1,4-다이옥산 및 디클로로메탄의 생태독성평가)

  • Choi, Jae Won;Lee, Sun Hee;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.466-471
    • /
    • 2019
  • 1,4-dioxane and dichloromethane are classified as carcinogenic groups in the International Agency for Research on Cancer (IARC). They are frequently released at high concentrations in an industrial wastewater effluent. The acute toxicity (24 h) of Daphnia magna for 7.53 mg/L of 1,4-dioxane in the industrial effluent was evaluated as 1.1 TU (toxic unit) and showed TU close to the effluent quality standard. Mixed substances of 1,4-dioxane and dichloromethane in the industrial effluent showed relatively high TU as compared to that of a single substance. Half maximal effective concentration (24 h $EC_{50}$) values of 1,4-dioxane and dichloromethane for the synthetic wastewater prepared in laboratory were 1,744 (0.06 TU) and 170 mg/L (0.6 TU), respectively and the toxicity was low. Nevertheless the toxicological evaluation of the mixture showed that TU values increased to 0.02, 0.04 and 0.10, respectively as 1, 5 and 10 ppm of dichloromethane was added to 100 ppm of 1,4-dioxane. And the synergistic effect was observed between two substances. But the TU value of synthetic wastewater was below 5%, lower than that of industrial effluent at the similar concentration.

Design and Performance Evaluation of Integral-type Hot BoP for Recovering High-temperature Exhaust Gas in 2 kW Class SOFC (2 kW급 고체산화물연료전지의 고온배기가스 폐열회수를 위한 일체형 Hot BoP의 설계 및 성능 평가)

  • Kim, Young Bae;Kim, Eun Ju;Yoon, Jonghyuk;Song, Hyoungwoon
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.62-67
    • /
    • 2019
  • This study was focused on the design and the performance analysis of integral Hot BoP for recovering waste heat from high-temperature exhaust gas in 2 kW class solid oxide fuel cell (SOFC). The hot BoP system was consisted of a catalytic combustor, air preheater and steam generator for burning the stack exhaust gas and for recovering waste heat. In the design of the system, the maximum possible heat transfer was calculated to analyze the heat distribution processes. The detail design of the air preheater and steam generator was carried out by solving the heat transfer equation. The hot BoP was fabricated as a single unit to reduce the heat loss. The simulated stack exhaust gas which considered SOFC operation was used to the performance test. In the hot BoP performance test, the heat transfer rate and system efficiency were measured under various heat loads. The combustibility with the equivalent ratio was analyzed by measuring CO emission of the exhaust gas. As a result, the thermal efficiency of the hot BoP was about 60% based on the standard heat load of 2 kW SOFC. CO emission of the exhaust gas rapidly decreased at an equivalent ratio of 0.25 or more.

Evaluation on In-plane Shear Strength of Lightweight Composite Panels (경량 복합패널의 면내 전단 성능 평가)

  • Hwang, Moon-Young;Kang, Su-Min;Lee, Byung-yun;Kim, Sung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.9-20
    • /
    • 2019
  • The number of natural disasters in Korea, such as earthquakes, is increasing. As a result, there is growing need for temporary residences or shelters for disaster conditions. The aim of this study was to produce post-disaster refugees housing differentiated from existing shelters using lightweight composite panels. To accomplish this, the structural performance of lightweight composite panels was validated, and an in-plane shear strength test was conducted according to the ASTM E72 criteria among the performance test methods for panels. As a result of the experiment, the maximum load for each specimen under an in-plane shear load was determined. All the experiments ended with the tear of the panel's skin section. The initial stiffness of the specimens was consistent with that predicted by the calculations. On the other hand, local crushing and tearing, as well as the characteristics of the panel, resulted in a decrease in stiffness and final failure. Specimens with an opening showed a difference in stiffness and strength from the basic experiment. The maximum load and the effective area were found to be proportional. Through this process, the allowable shear stress of the specimens was calculated and the average allowable shear stress was determined. The average ultimate shear stress of the lightweight composite panels was found to be $0.047N/mm^2$, which provides a criterion of judgement that could be used to expect the allowable load of lightweight composite panels.

Estimation of Permanent Displacement of Gravity Quay Wall Considering Failure Surface under Seismic Loading (지진 시 파괴면을 고려한 중력식 안벽의 영구변위 평가)

  • Han, Insuk;Ahn, Jae-Kwang;Park, Duhee;Kwon, Osoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.4
    • /
    • pp.15-26
    • /
    • 2019
  • The stability of the gravity quay wall against earthquakes is evaluated on the basis of the allowable displacement of the wall. To estimate the displacement caused by external forces, empirical equations based on the Newmark sliding block method or numerical analysis are widely used. In numerical analysis, it is possible to analyze precisely a complicated site and structure, but difficult to set the appropriate parameters and environments; there are limitations in obtaining reliable results, depending on one's level of expertise. The Newmark method, with only seismic motions, is widely used because it is simpler than numerical simulations when estimating permanent displacement. However, the empirical equations do not have any parameters for the response characteristics and sliding block of the structure, and sliding blocks being assumed as rigid bodies does not consider the nonlinear behavior of the soil and interaction with the structure. Therefore, in order to evaluate the seismic stability of the gravity quay wall, a newly-developed empirical equation is needed to overcome the above-mentioned limitations. In this study, numerical simulations are performed to analyze the response characteristics of the backfill of the structure, and to propose an optimal method of calculating the active area. For this purpose, finite element analyses were performed to analyze the response characteristics, and stress-strain relationships for various seismic motions. As a result, the response characteristics, sliding block, and failure surface of the backfill vary depending on the input seismic motions.

A Study on the Long-term Settlement Characteristics of Thick Clay Deposits Using Field Monitoring (대심도 연약지반의 현장계측을 이용한 장기침하거동특성 분석에 관한 연구)

  • Kwon, Hyun-Wook;Im, Jong-Chul;Chang, Ji-Gun;Kang, Sang-Kyun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.21-28
    • /
    • 2018
  • Despite a number of studies on consolidation behavior that have been carried out in the Nakdong River estuary in Busan, these are focused on the prediction of final settlement during ground improvement process, and there is almost no research on the long-term settlement occurring after that. For the practical study on the long-term settlement, the field monitored settlement data that measured over 10 years in the Busan new port facilities area were used, and the final settlement and predicted time-settlement line were constituted by hyperbolic function. As a result, the measured settlements depend on the thickness of clayey soils, and the pattern were similar to each other and good agreement with the predicted time-settlement line using hyperbolic method. Also, the settlement in the lower non-improved layer occupied 62-76% of total settlement. Information about above results would be quite helpful to understand the long-term settlement behaviors as well as the non-improved layer's settlement is more careful consideration needed at design phase.

Smoke Generation by Burning Test of Cypress Plates Treated with Boron Compounds (붕소 화합물로 처리된 편백목재의 연소시험에 의한 연기발생)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.670-676
    • /
    • 2018
  • Experiments on combustion gases generation of untreated cypress specimens or treated with boric acid, ammonium pentaborate, and boric acid/ammonium pentaborate additive were carried out. Test specimens were painted three times with 15 wt% boron compound aqueous solutions. After drying, the generation of combustion gas was analyzed using a cone calorimeter (ISO 5660-1). As a result, comparing to untreated specimen, the smoke performance index (SPI) of the specimens treated with the boron compound increased by 1.37 to 2.68 times and the smoke growth index (SGI) decreased by 29.4 to 52.9%. The smoke intensity (SI) of the specimens treated with boron compounds is expected to be 1.16 to 3.92 times lower than that of untreated specimens, resulting in lower smoke and fire hazards. Also, the maximum carbon monoxide ($CO_{peak}$) concentration of specimens treated with boron compounds was 12.7 to 30.9% lower than that of untreated specimens. However, it was measured to produce fatal toxicities from 1.52 to 1.92 times higher than that of permissible exposure limits (PEL) by Occupational Safety and Health Administration (OSHA). The boron compounds played a role in reducing carbon monoxide, but it did not meet the expectation of reduction effect because of the high concentration of carbon monoxide in cypress itself.