• Title/Summary/Keyword: 핵의학 검사

Search Result 664, Processing Time 0.02 seconds

Evaluation of Peptide Nucleic Acid Probe-Based Fluorescence In Situ Hybridization for the Detection of Mycobacterium tuberculosis Complex and Nontuberculous Mycobacteria in Clinical Respiratory Specimens (임상 객담검체에서 Peptide Nucleic Acid Probe를 이용한 결핵과 비결핵 항산균의 구분)

  • Lee, Seung Hee;Kim, Shine Young;Kim, Hyung Hoi;Lee, Eun Yup;Chang, Chulhun L.
    • Annals of Clinical Microbiology
    • /
    • v.18 no.2
    • /
    • pp.37-43
    • /
    • 2015
  • Background: Tuberculosis is globally the most important cause of death from single pathogen. Rapid and accurate identification of mycobacteria is essential for the control of tuberculosis. We evaluated a fluorescence in situ hybridization (FISH) method using peptide nucleic acid (PNA) probes for the differentiation of Mycobacterium tuberculosis complex (MTB) and nontuberculous mycobacteria (NTM) in direct smears of sputum specimens. Methods: The cross-reactivity of MTB- and NTM-specific PNA probes was examined with reference strains of M. tuberculosis ATCC 13950, Mycobacterium kansasii ATCC 12479, Mycobacterium fortuitum ATCC 6841, several clinical isolates of mycobacteria (Mycobacterium abscessus, Mycobacterium avium, Mycobacterium intracellulare, Mycobacterium gordonae and Mycobacterium chelonae), and 11 frequently isolated respiratory bacterial species other than mycobacteria. A series of 128 sputa (89 MTB culture positive, 29 NTM culture positive, and 10 under treatment culture negative) with grades of trace to 4+ were used to evaluate the performance of the method. Results: The MTB- and NTM-specific PNA probes showed specific reactions with the reference strains of MTB and M. kansasii and clinical isolates of mycobacteria except M. fortuitum ATCC 6841, and no cross-reactivity with other tested bacteria. The PNA probe-based FISH assay for detection of MTB had a sensitivity and specificity of 100%, respectively. The sensitivity and specificity of the NTM-specific PNA probe was 100%. The smear grades of the PNA FISH test were same as with those of the fluorescence AFB stain in 2+ or higher grade. Conclusion: Detection and differentiation based on PNA FISH is sensitive and accurate for detecting mycobacteria and for differentiating MTB from NTM in clinical sputum smears.

The Reduction ways of Medicine Material Costs of Nuclear Medicine In Vitro (핵의학 체외검사의 진료재료비용 절감 방안)

  • Song, Hun-Kang;Seo, Jung-Mi;Yang, Joon-Ho;Kim, Eun-Jung;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.111-115
    • /
    • 2011
  • Purpose: In vitro uses dose response curve with 6 to 7 standard concentrations in every examination to analyze examination results and this use of dose response curve comprises a large portion of the consumption of medicine material. At this present, some ones of in-hospital examination items have shown mostly low result of distribution in the analyzed features and these examinations have been judged that it would be unnecessary to use the last standard concentration. Hence, this study selects those examination items showing low result of distribution and reviews the cases contributed to less consumption of medicine material and revenue growth of hospital by reduction of medicine material used in the place of the last standard concentration. Materials and Methods: The study was made targeting 11 examination items out of total 43 items of the in-hospital examination and since these examination items were mostly low in the features as the examination results of patients or the examination results were distributed to show lower concentration than the previous last standard concentration, it carried out the examination without using the last standard concentration, which could generate the effect to reduce medicine material (examination tube) used in the last standard concentration as many as the number of examination carried out. For this, it examined the number of medicine material reduction by month during the period from July, 2009 to February, 2011 and estimated the reduction amount of medicine material calculated the number of reduction by the unit cost of medicine material as well as the profit generated by the reduced medicine material to use for the medicine material of patient examination. Results: The total number of medicine material reduced during the period from July, 2009 to February, 2011 was 3,131 pieces, which had the effect to reduce the medicine material equivalent to about 31 kits of reagent. To calculate this by the unit cost of the medicine material, it analyzed to reduce about 6.4 million won of medicine material cost. Also the reduced medicine materials were used for medicine materials of patient examination and this was analyzed to generate about 13.75 million won of profit based on the ABC cost accounting. Conclusion: It showed no problem in the analysis of examination result even without using the last standard concentration regarding those examination items with low distribution of the patient examination result. For these examination items, it was able to reduce medicine material used for the last standard as many as the number of examination carried out. Also, the adjustment of concentration range was found to have no problem in the reliability of examination result. Therefore, this case will be applicable in those occasions of when the analysis of patient examination result is mostly distributed at the lower level or when an examination with the distribution of patient results in the range of lower concentration than the previous last standard concentration is carried out and this is considered to increase the efficiency in the use of medicine material in vitro as well as contribute to the profit of hospitals.

  • PDF

Examination Techniques and Imaging Findings of Hepatic Hemangioma (간혈관종의 검사기법과 영상소견)

  • Chang-Hoe Koo;Jong-Wan Keum;Ji-Eun Seok;Dong-Chul Choi;Yun-Ho Choi;Man-Seok Han;Min-Cheol Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.375-384
    • /
    • 2023
  • Most Hepatic hemangiomas are asymptomatic and small in size, making them difficult to find by pathological examination. Therefore, radiological diagnosis is essential for the early finding and diagnosis of Hepatic hemangioma. Three-phase method using contrast medium in computed tomography, T1, T2-weighted imaging in magnetic resonance imaging, dynamic magnetic resonance imaging using contrast medium, echo planar imaging method, diffusion-weighted imaging method, blood pool scan using 99mTc-labeled red blood cells in nuclear medicine, we looked at the color doppler method In ultrasound, and it is important to accurately understand the imaging findings of hepatic hemangioma and perform the examination in order to make an accurate diagnosis. most hepatic hemangioma are benign tumors, care should be taken not to confuse them with malignant tumors such as hepatocellular carcinoma to prevent unnecessary procedures. Therefore, in order to make an accurate diagnosis, it is important to accurately understand the imaging findings of hemangioma and perform the examination.

Verification of the upper limit of results through dilution tests for RIA test (RIA 검사별 희석실험을 통한 결과의 상한치 검증)

  • LEE, Geun Ui;CHOI, Jin Ju;LEE, Young Ji;YOO, Seon Hee;LEE, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.42-46
    • /
    • 2022
  • Purpose In the meantime, there have been not many samples that require dilution, and it has been difficult for the examiner to set an appropriate dilution multiple for RIA test item and report the results. Accordingly, it was judged that it was necessary to set the maximum dilution multiple for each test and to verify the upper limit of the clinical reportable range. Therefore, in this study, the maximum dilution multiple for each RIA test was set and the upper limit of the clinical reportable range was verified accordingly Materials and Methods Among all RIA tests conducted at Asan Medical Center, the study treated on 30 types of tests which also conduct the dilution test. Data from March to July 2021 were collected and analyzed. The study was conducted on samples subjected to serial dilutions such as X2, X4 or X10, X102, X103, X104, X105. Results Among a total of 30 test types, 18 test types have more than 5 N values in the tolerance range of 80~120%. As a result of the verification of maximum dilution multiples, the test set to 104 is 𝛼-fetoprotein and thyroglobulin, and the test set to 103 is CA-125, CEA, and 𝛽-hCG, and the test set to 102 is Free PSA, PSA, CA15-3, SCC, Ferritin, PTH, Cortisol, and Calcitonin. Tests set to 10 include three categories: 𝛽2-Microglobulin, C-peptide, and Testosterone. Conclusion It is expected that it will contribute to improving the quality of nuclear medicine blood tests as the results of dilution experiments can be reported quickly and accurately through the verification of the clinical reportable range.

A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay (핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰)

  • Young Ji, LEE;So Young, LEE;Sun Ho, LEE
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.43-47
    • /
    • 2022
  • Purpose Radioimmunoassay implement quality control by systematizing the internal quality control system for quality assurance of test results. This study aims to contribute to the quality assurance of radioimmunoassay results and to implement systematic quality control by measuring the average CV of internal quality control and external quality control by plenty of institutions for reference when setting the laboratory's own acceptable range. Materials and Methods We measured the average CV of internal quality control and the bounce rate of more than 10.0% for a total of 42 items from October 2020 to December 2021. According to the CV result, we classified and compared the upper group (5.0% or less), the middle group (5.0~10.0%) and the lower group (10.0% or more). The bounce rate of 10.0% or more was compared by classifying the item of five or more institutions into tumor markers, thyroid hormones and other hormones. The average CV was measured by the overall average and standard deviation of the external quality control results for 28 items from the first quarter to the fourth quarter of 2021. In addition, the average CV was measured by the overall average and standard deviation of the proficiency results between institutions for 13 items in the first half and the second half of 2021. The average CV of internal quality control and external quality control was compared by item so we compared and analyzed the items that implement well to quality control and the items that require attention to quality control. Results As a result of measuring the precision average of internal quality control for 42 items of six institutions, the top group (5.0% or less) are Ferritin, HGH, SHBG, and 25-OH-VitD, while the bottom group (≤10.0%) are cortisol, ATA, AMA, renin, and estradiol. When comparing more than 10.0% bounce rate of CV for tumor markers, CA-125 (6.7%), CA-19-9 (9.8%) implemented well, while SCC-Ag (24.3%), CA-15-3 (26.7%) were among the items that require attention to control. As a result of comparing the bounce rate of more than 10.0% of CV for thyroid hormones examination, free T4 (2.1%), T3 (9.3%) showed excellent performance and AMA (39.6%), ATA (51.6%) required attention to control. When comparing the bounce rate of 10.0% or more of CV for other hormones, IGF-1 (8.8%), FSH (9.1%), prolactin (9.2%) showed excellent performance, however estradiol (37.3%), testosterone (37.7%), cortisol (44.4%) required attention to control. As a result of measuring the average CV of the whole institutions participating at external quality control for 28 items, HGH and SCC-Ag were included in the top group (≤10.0%), however ATA, estradiol, TSI, and thyroglobulin included in bottom group (≥30.0%). Conclusion As a result of evaluating 42 items of six institutions, the average CV was 3.7~12.2% showing a 3.3 times difference between the upper group and the lower group. Cortisol, ATA, AMA, Renin and estradiol tests with high CV will require continuous improvement activities to improve precision. In addition, we measured and compared the overall average CV of the internal quality control, the external quality control and the proficiency between institutions participating of six institutions for 41 items excluding HBs-Ab. As a result, ATA, AMA, Renin and estradiol belong to the same subgroup so we require attention to control and consider setting a higher acceptable range. It is recommended to set and control the acceptable range standard of internal quality control CV in consideration of many things in the laboratory due to the different reagents and instruments, and the results vary depending on the test's proficiency and quality control materials. It is thought that the accuracy and reliability of radioimmunoassay results can be improved if systematic quality control is implemented based on the set acceptable range.

Reducing error rates in general nuclear medicine imaging to increase patient satisfaction (핵의학 일반영상 검사업무 오류개선 활동에 따른 환자 만족도)

  • Kim, Ho-Sung;Im, In-Chul;Park, Cheol-Woo;Lim, Jong-Duek;Kim, Sun-Geun;Lee, Jae-Seung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.295-302
    • /
    • 2011
  • To n the field of nuclear medicine, with regard to checking regular patients, from the moment they register up to the doctor's diagnosis, the person in charge of the checks can find errors in the diagnosis, reexamine, reanalyze the results or save images to PACS. Through this process, the results obtained from the readings are delayed due to checks and additional tests which occur in hospitals, causing patient satisfaction and affected reliability. Accordingly, the purpose is to include visual inspection of the results to minimize error, improve efficiency and increase patient satisfaction. Nuclear medicine and imaging tests from examines at Asan Medical Center, Seoul, from March 2008 to December 2008, were analyzed for errors. The first stage, from January 2009 to December 2009, established procedures and know-how. The second stage from January 2010 until June 2010 conducted Pre-and Post-filtering assessment, and the third stage from July 2010 until October 2010 consisted of cross-checks and attaching stickers and comparing error cases. Of 92 errors, the 1st, 2nd and 3rd stage had 32 cases, and there were 46 cases after the 4th stage, with the overall errors reduced by 74.3% from 94.6%. In the field of general nuclear medicine, where various kinds of checks are performed according to the patient's needs, analysis, image composition, differing images in PACS, etc, all have the potential for mistakes to be made. In order to decrease error rates, the image can continuously Cross-Check and Confirm diagnosis.

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

Scintigraphic Evaluation of Gastrointestinal Motility Disorders (기능성 위장관 질환에서 핵의학 검사의 역할)

  • Choe, Jae-Gol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2001
  • Current scintigraphic tests of gastrointestinal motor function provides relevant pathophysiologic information, but their clinical utility is controversial. Many scintigraphic methods are developed to investigate gastrointestinal motility from oral cavity to colon. These are esophageal transit scintigraphy, oropharyngeal transit study, gastric emptying test, small bowel transit time measurement, colon transit study and gastroesopahgeal reflux scintigraphy. Scintigraphy of gastrointestinal tract is the most physiologic and noninvasive method to evaluate gastrointestinal motility disorders. Stomach emptying test is regarded as a gold standard in motility study. Gastrointestinal transit scintigraphy also has a certain role in assessment of drug effect to GI motility and changes alter therapy of motility disorders. Scintigraphy provides noninvasive and quantitative assessment of physiological transit throughout the gastrointestinal tract, and it is extremely useful for diagnosing gastrointestinal motor dysfunction. This article reviews the current procedures, indications, significance and guidelines for gastrointestinal motility measurements by scintigraphy.

  • PDF

Comparison of Estradiol Results according to Manufacturer (제조회사에 따른 Estradiol 결과값의 비교)

  • Kim, Dae-Woon;Shin, Hee-Jung;You, Tae-Min;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.101-105
    • /
    • 2011
  • Purpose: Estradiol in the menstrual cycle and ovulation induction as an important test of currently national nuclear medicine laboratory in the normal patients and patients with infertility tests are being performed. For the diagnosis of menopause is an important test with follicle stimulating hormone (FSH) and Luteinizing hormone (LH). Currently participating in external quality control of the nation's hospitals that is 54 percent of 37 hospitals, 20 hospitals have been using A's reagent. The kit's test results are highly different from other kit comes with the test results of specimens have been found. And for the phenomenon is to study the problem. Materials and Methods: Estraiol test were referred to our hospital which results of samples as more than 100pg/ml 75 specimens measured by radioimmunoassay(RIA) test with company A company B company C company D Kit, Chemiluminescent assay (CMIA) to examine and compare to the results from april to August in 2010. Results: Kit for each manufacturing company as measured by the results obtained using the average value of the correlation coefficient (R2) and A company 0.8906 B 0.9527 C 0.9547 and D company correlation coefficient of 0.873 showed a good correlation that measuring the results of A company high concentrations when Company B Company C Company D with CMIA test concentrations measured low results that the two cases were discovered specimens. Conclusion: Most of the test results of 75 samples came up with a similar trend, but two cases were reported in the patients very differently. A company result reported higher than 700 pg/ml, while the rest of other test results report was approximately 10 pg/ml. The common point of two samples more than 50 years patients are estimated to be diagnosed with cancer in postmenopausal patients receiving treatment and levels of FSH were found to be greater than 50 mIU/ml. Did not identify the exact cause. I suggest if you are using A company kit that need to again check when Estradiol result and follicle stimulating hormone results is higher.

  • PDF

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF