• Title/Summary/Keyword: 해양발전소

Search Result 183, Processing Time 0.023 seconds

A Study on the Towing Force of Heavy Loaded Barge against Strong Current (강조류에서 중량물 운반 부선의 예인력에 관한 연구)

  • Kim, Chol-Seong;Rim, Geug-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.2
    • /
    • pp.179-185
    • /
    • 2011
  • A marine collision accident occurred at the Jin-do water way. A barge loaded with heavy equipment of Power Generation Plant was being towed at its side by two tugs "A" and "B" from Byeg-pa harbour to the designated position to be used for power generation plant near Jin-do bridge. The Power Generation Plant was 40-meters high loaded atop the barge. When the "tugs and tow" were approaching the Jin-do the bridge, the two towing tugs lost maneuvering control of the barge and it went off-course, hit first the waterway embankment and finally struck the lower part of bridge's span and post musing the barge to capsize and sunk its cargo into the sea. The bridge also suffered damages where the top of the Plant struck At the time of the accident, there was a strong tidal current at the waterway. This paper calculates the safe towing force of barges with heavy loads when traversing in a strong tidal current situation in narrow waterway.

Marine Pollution in Korean Seas: An Emerging Environmental Issue (우리 나라 주변해역의 오염현황과 오오원)

  • 이동수
    • 한국해양학회지
    • /
    • v.28 no.2
    • /
    • pp.132-136
    • /
    • 1993
  • Attempt was made to identify potential pollutants in Korean Sean and to assess their environmental qualities. Existing pollution data for these Seas so scarce that environmental quality assessment was not possible. However, numerous pollutants were identified. Among them, heat and radioactivity from electric power plants, organic wastes from ocean dumping and land based sources, and accidentally spilled oils are suspected to be of most concern.

  • PDF

Application of Geostatistical Analysis Method to Detect the Direction of Sea Surface Warm Flows (해수면 난류수 유동방향 탐지를 위한 지구통계학적 분석기법 적용)

  • Choi, Hyun-Woo;Kim, Hyun-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.1
    • /
    • pp.168-178
    • /
    • 2006
  • In recent years, an ingress of mass jellyfish into cooling water intake system causes interruption of electric power production at the Uljin nuclear power plant. Therefore, monitering and forecast on the mass ingress of marine organisms are demanded as one of the early preventing measurements. Sea water movement is a major factor on the ingress of marine organisms like Moon jellyfish which has weak self-mobile ability. When sea surface flow direction adjacent to the Uljin is the northwest, the jellyfish on the Tsushima warm currents move to the Uljin power plant. To detect the direction of sea surface warm flows, the spatial range with $25km{\times}25km$ is set up and NOAA sea surface temperature(SST) data are collected in this area. For the statistical analysis, the SST data are made as GIS point data and geostatistical analysis of ArcGIS is used. Analyzing directional semivariogram, the anisotropy of the SST point data are calculated and warm flow direction is detected. This experimental results are expected to use as an element technology for the early warning system development of mass jellyfish ingress in power plant.

  • PDF

Preventing marine organisms adhesion by oil-infused PDMS (오일이 주입된 PDMS를 이용한 해양생물의 부착방지 방법에 대한 고찰)

  • Kim, Su-Yeong;Yun, Yeong-Cheol;Im, Chae-Gang;Jeong, Yong-Chan;Lee, Su-Yeol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.45-45
    • /
    • 2018
  • 홍합, 따개비 등의 접착성 해양생물은 선박의 하부나 발전소 해수 공급용 튜브에 부착하여 운영 효율을 저하 시키고, 냉각기기 고장을 유발하는 파울링(Fouling) 문제를 야기시킨다. 일반적으로 이러한 문제에 대응하기 위해서 초접착성 해양생물이 주로 부착하는 부위에 $Cu_2O$, ZnO 등을 포함한 유기화합물로 표면처리를 하여 부착방지를 하고 있지만, 이 소재들을 장시간 사용 시 해양 오염 및 부식을 가속화하는 문제를 초례하기 때문에 최근에는 사용을 금지하고 있다. 이러한 유해성 소재 문제를 해결하고자 친환경적이고 부작용이 없는 초접착성 해양생물 부착방지 소재를 개발하고자 하였다. 본 연구에서는 낮은 표면장력을 갖는 PDMS(Polydimethylsiloxane) 소재를 기반으로 소수성 oil을 침투시킨 I-PDMS(Oil-Polydimethylsiloxane) 표면처리법을 고안하였고, 이 방법을 활용하여 초접착성 해양생물에 대한 부착방지 성능을 향상시키고자 하였다. 기존의 개발품들 보다 성능이 향상된 I-PDMS 제조하고자, Nano-indentation을 이용한 기계적 특성 평가, X컷 및 cross-cut을 이용한 부착력 평가, 실제 바다환경에서 해양생물의 부착력 시험, 바다 환경을 모사한 수조에서의 I-PDMS와 비교군 기판에서의 홍합 거동, 홍합과 기판의 접착강도 시험, 해양 미생물 평가를 실시하였으며, 이를 통해서 I-PDMS 성능 및 내구성을 입증하고자 하였다.

  • PDF

Process Design of Carbon Dioxide Storage in the Marine Geological Structure: II. Effect of Thermodynamic Equations of State on Compression and Transport Process (이산화탄소 해양지중저장 처리를 위한 공정 설계: II. 열역학 상태방정식이 압축 및 수송 공정에 미치는 영향 평가)

  • Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.4
    • /
    • pp.191-198
    • /
    • 2008
  • To design a reliable $CO_2$ marine geological storage system, it is necessary to perform numerical process simulation using thermodynamic equation of state. $CO_2$ capture process from the major point sources such as power plants, transport process from the capture sites to storage sites and storage process to inject $CO_2$ into the deep marine geological structure can be simulate with numerical modeling. The purpose of this paper is to compare and analyse the relevant equations of state including ideal, BWRS, PR, PRBM and SRK equation of state. We also studied the effect of thermodynamic equation of state in designing the compression and transport process. As a results of comparison of numerical calculations, all relevant equation of state excluding ideal equation of state showed similar compression behavior in pure $CO_2$. On the other hand, calculation results of BWRS, PR and PRBM showed totally different behavior in compression and transport process of captured $CO_2$ mixture from the oxy-fuel combustion coal-fired plants. It is recommended to use PR or PRBM in designing of compression and transport process of $CO_2$ mixture containing NO, Ar and $O_2$.

  • PDF

Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Ultrasonic Frequency Analysis Spectrum Method (초음파 주파수분석법에 의한 발전소 고온배관재료의 크리프손상 평가)

  • Chung, Min-Hwa;Lee, Sang-Guk
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.90-98
    • /
    • 1999
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operationg conditions like high temperature and high pressure for an extended period time. Such material degradation lead to various component faliures causing serious accidents at the plant. Conventional measurement techniques such as replica method, electric resistance method, and hardness test method have such disadvantages as complex preparation and measurement procedures, too many control parameters, and therefore, low practicality and they were applied only to component surfaces with good accessibility. In this study, both artificial creep degradation test using life prediction formula and frequency analysis by ultrasonic tests for their preparing creep degraded specimens have been carried out for the purpose of nondestructive evaluation for creep damage which can occur in high-temperature pipelline of fossil power plant. As a result of ultrasonic tests for crept specimens, we confirmed that the high frequency side spectra decrease and central frequency components shift to low frequency bans, and bandwiths decrease as increasing creep damage in backwall echoes.

  • PDF

Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Ultrasonic Test Method (초음파에 의한 발전소 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk;Chung, Min-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.99-107
    • /
    • 1999
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operationg conditions which are high temperature and high pressure for an extended period time. Such material degradation leads to various component failures causing serious accidents at the plants. Conventional measurement techniques such as replica method, electric resistance method, and hardness test method have such disadvantages as complex preparation and measurement procedures, too many control parameters, and therefore, low practicality and they were applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens have been carried out for the purpose of evaluation for creep damage which can occur in high-temperature pipeline of fossil power plant. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradationtests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens, we confirmed that the sound velocity decreased and the attenuation coefficient linearly increased in proportion to the increase of creep fractiin(${\phi}$c).

  • PDF

A Study on Regenerative OTEC System using the Condenser Effluent of Uljin Nuclear Power Plant (울진 원자력발전소 온배수를 이용한 재생식 해양온도차발전에 대한 연구)

  • Kang, Yun-Young;Park, Sung-Seek;Park, Yun-Beom;Kim, Nam-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.591-597
    • /
    • 2012
  • For the past few years, the concern for clean energy has been greatly increased. Ocean thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this study, we examined the thermodynamic performance of the OTEC power system for the production of electric power. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regenerative cycle, Kalina cycle, open cycle, and hybrid cycle. The results show that the regenerative cycle showed the best system efficiency. And then we examined the thermodynamic performance of regenerative cycle OTEC power system using the condenser effluent from Uljin nuclear power plant instead of the surface water. The highest system efficiency of the condition was 4.55% and the highest net power was 181 MW.

Revaluation of Tsunami Risk at the Site of Ulchin Nuclear Power Plant (울진 원자력발전소 부지에 대한 지진해일 위험도 재평가)

  • 이해균;이대수
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • In the past, safety assessment on the site of Ulchin Nuclear Power Plants against tsunamis was carried out with probable maximum earthquake magnitude and related tsunamigenic fault parameters. Recently, however, based on the seismic gap theory, some seismologists warned about earthquakes of larger magnitudes than had been expected. In this study, we revaluated tsunami risk with a finite difference model based on linear and nonlinear shallow water equations. Firstly, we simulated the\`83 tsunami and compared the calculated water surface profile with the observed wave heights. Secondly, we evaluated the rise and drop of sea water level at the site of Ulchin Nuclear Power Plant with fault parameters of the past '83, '93 tsunamis and some dangerous faults. Finally, we showed that the cooling water intake facility of Ulchin Nuclear Power Plants would be safely operated in disastrous tsunamis.