• 제목/요약/키워드: 합성 PC부재

검색결과 16건 처리시간 0.024초

합성 PC 부재 현장생산배치에 관한 기초 연구 (A Basic Study on the Arrangement of In-situ Production Module of the Composite PC Members)

  • 이군재;주진규;이성호;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2011
  • A Green Frame is a composite Rahmen precast concrete structure that utilizes the advantages of the steel frame and the reinforced concrete. Compared to bearing wall structure, the precast concrete structure may raise construction cost If the precast concrete members are produced in plant. Thus, if the precast concrete members can be produced in site, the cost-effectiveness and quality shall be increased. Various site conditions must be considered and reviewed to ensure a space for the in-situ production. Therefore, this study focuses on the basic study on the arrangement of in-situ production module of composite precast concrete members.

  • PDF

U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel)

  • 하수경;손국원;유승룡;주호성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.18-28
    • /
    • 2015
  • 이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는데 있다. 1개의 무 보강 보-기둥 실험체와 U형 PC 패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커 접합부 실험체는 전단 파괴될 것으로 해석되었고 철판 용접 접합부 실험체는 휨 파괴할 것으로 예측되었다. 실험체의 종국 내력은 상부 접합부의 전단 내력과 PC 패널 절곡 부 휨 위험단면에서 휨 내력 중 약한 것으로 결정되었다. 이 실험체에서, 한쪽 RC기둥이 가 하중(미는 실험 하중)을 받아 PC 패널 부재를 밀게 된다면, 다른 쪽 내부 수직부재는 상부 전단 접합부로부터 부 하중(당기는 실험 하중)을 받게 되어있었다. 가 하중을 받는 2개의 부재는 합성 휨 거동이 지배적이므로 합성단면의 휨 내력이 실험체의 최종 내력을 결정하게 되지만, 이 경우 최종 내력에 대하여 상부 전단 접합부 강도의 직접적인 영향은 없다고 볼 수 있다. 그러나 부 하중(당기는 하중)을 받는 RC 기둥과 PC 패널 부재는 비합성 거동이 지배적이고 실험체의 최종 내력은 상부 전단 접합부 전단내력의 크기에서 직접 영향을 받는 것으로 파악되었다. ACI 318M-11 Appendix-D 앵커 전단설계에 기초한 전단내력 그리고 실험에서 얻은 최대하중을 적용하여 마이다스 젠 탄성설계에 의하여 계산한 전단 외력에 대한 비교 해석결과는 실험결과와 일치하는 해석결과를 보여주었다.

합성 PC부재의 Steel-joint Connection Method 개발 기초연구 (A basic study of steel-joint connection method of composite precast concrete members)

  • 김근호;이동훈;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2013
  • Green Frame is a column-beam system formed by composite precast concrete column and beam connected with steel buried in both members. During the installation of Green columns, the columns of Green Frame, covering 3 floors per each piece and beams, the eccentricity can be observed due to the construction error and the weight of beam itself. Such eccentricity may have a little influence on a single frame, yet, it can develop critical issues to the installation of subsequent beams or beams on the upper floors in the context of a building as a whole that has multiple frames. These issues lead to delay in frame installation, decrease of productivity and increase of cost, etc. Therefore, this study presents a steel-joint connection method in order to solve the issues. The steel-joint connection method exists on slope plane and reinforcing plate in steel frame buried in composite PC members. Through this method, the issues can be resolved without requiring additional equipment or manpower.

  • PDF

합성 PC 부재의 철골 물량산출 알고리즘 기초연구 (Basic study of algorithm for steel quantity analysis of composite precast concrete members)

  • 김경주;임채연;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.96-97
    • /
    • 2014
  • Green Frame is a column-beam structure built by steel frame joints embedded in the columns and beams. Here, the steel frame embedded in the columns and beams is not a standardized product, instead it needs to be order-produced. The quantity for each steel frame size should be calculated to estimate the quantity of steel frames to be manufactured. However, it is highly time-consuming and requires a lot of effort in calculating the quantity of steel frames, for there are a wide range of steel frame types that are embedded in the columns and beams. To solve this problem, the study proposes an algorithm for calculation of the amount of steel frames with ease and promptness. When a program is developed using the algorithm proposed in the study in connection to the information on precast concrete members prepared in the design phase, it is anticipated that the manpower required as well as the manufacturing time will be decreased.

  • PDF

중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동 (Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio)

  • 이승준;서수연;배문용;김강수
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.441-448
    • /
    • 2014
  • 최근 일련의 연구로부터, 중공이 있는 프리캐스트 콘크리트(hollewed precast concrete, HPC) 기둥를 사용할 경우, 일반적인 PC기둥에 비하여 접합부 콘크리트를 충실하게 채울수 있으며 이에 따라, 접합부의 고정도는 일체식 철근콘크리트(RC)와 같이 향상될 수 있음이 확인되었다. 그러나 충전콘크리트로 중공부가 채워진 후, HPC부재와 충전콘크리트의 강도가 서로 다르고 이 두 부재 사이에는 접촉면이 있음에 따라 합성구조와 같은 거동을 보이게 되며 이는 합성된 기둥의 구조적 거동과 강도에 영향을 미치게 된다. 이 논문에서는 HPC 기둥에서 중공의 크기와 중공부분 콘크리트의 채움 유무에 따른 기둥의 압축강도 시험을 실시하였다. 중공의 비율은 35, 50 그리고 59%이며 실험체의 양단을 단순지지 형태로서 지지한 뒤 중심압축력을 기둥의 상단에 작용시켰다. 또한 압축에 대한 HPC 기둥의 파괴거동을 묘사하기 위하여 유한요소 해석을 실시하였다. 실험 결과, 중공내부가 충전콘크리트로 채워진 기둥에서, PC와 충전콘크리트의 강도차이와 상관없이 중공률은 기둥의 초기강성에 영향을 미치지 않는 것으로 나타났다. 그러나 기둥의 압축강도는 중공률에 반비례하는 것으로 나타났다. 충전콘크리트가 채워지지 않은 HPC기둥의 구조성능은 중공의 직경에 밀접하게 관련이 있는 것으로 나타났으며, 특히, HPC의 두께가 지나치게 얇은 경우에는 국부적인 파괴가 전체 파괴를 지배하는 것으로 나타났다. 이러한 영향을 고려하여 HPC기둥의 압축내력을 산정할 수 있는 식을 제시하였다. 유한요소해석에서는, HPC와 충전콘크리트 사이의 접촉면을 고려할 경우, 해석 결과가 실험 결과와 좋은 대응을 보이는 것으로 나타났다.

비부착 압축 프리스트레싱을 도입한 중공박스 거더의 거동 (Behavior of Hollow Box Girder Using Unbonded Compressive Pre-stressing)

  • 김성배;김장호;김태균;어철수
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.201-209
    • /
    • 2010
  • 일반적으로 PSC 거더 교량은 철근 콘크리트 부재와 달리 전단면을 사용하여 외부하중을 저항한다. 또한 설계와 시공의 용이성, 구조적 안전성, 경제성, 유지관리의 편리성 등의 장점 때문에 30 m 이하의 중/소 경간 교량에 많이 적용되고 있다. 그러나, 최근 전세계적으로 환경, 미관 등에 관심이 높아짐에 따라, 교량의 경간은 점점 길어지는 추세이다. 이러한 추세는 케이블 교량뿐만 아니라 PSC 교량에서도 나타난다. 본 연구는 시대적 흐름에 맞춰 PSC 거더를 50 m 이상의 장경간에 적용하기 위한 연구의 일환으로 상부에 H형 강재가 도입된 중공 박스 합성거더를 개발하였다. 개발된 거더는 타설 전 상부에 H형 강재에 미리 비부착 압축 프리스트레스를 주어 거더의 성능저하 시 프리스트레스력을 제거하여 성능을 회복시키는 방법이다. 개발된 거더는 실제 교량에 사용하기위한 필수적인 정적실험을 3점 재하로 4단계로 구분하여 수행하였다. 1차 하중은 균열발생시점까지로 하였으며, 하중 제거 후 미리 상부강재에 도입된 프리스트레스력을 제거하여 거더의 성능회복력을 확인하였다. 그 후, 거더가 파괴될 때까지 하중을 재하하였다. 실험 결과, 18.7 mm의 잔류변형이 발생하였으나, 상부 강재의 PS 제거에 의해 7.7 mm로 회복되었다. 즉, 상부 H형 강재에 도입된 비부착 압축프리스트레스의 제거에 의한 거더 하연의 추가 압축응력으로 하중 증가에 따른 잔류변형을 약 60%가량 회복시키는 성능향상을 보였다. 상부에 H형 강재를 시공함으로써 추후 보수보강을 용이하게 할 수 있고, 비용도 절감할 수 있다.