• Title/Summary/Keyword: 한국의 방사선치료

Search Result 1,039, Processing Time 0.033 seconds

Hematological Change in Mice Injected with Radiosensitizer and Irradiated with High-dose Radiation (방사선 증감제를 투여한 마우스에 고 에너지 방사선 조사 후 혈액학적 변화에 관한 연구)

  • Ji, Yeon-Sang;Dong, Kyung-Rae;Jung, Myo-Young;Park, Yong-Soon;Dong, Cha-Bun;Ryu, Young-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.357-363
    • /
    • 2009
  • The current population of elderly is increasing and the with an extended average lifespan, the frequency of cancerous occurrences have also increased, with these increases and the increase in radiotherapy for cancer patients, recognitions of harm and importance have become known. This article was known tumor treatment of patients with hematopoietic disorder by doing a comparative study on the changes in blood cells caused by the acute effects of trace dose to high dose of radiation exposed to mice. According to the sensitizer injection may give rise to harm to the components of peripheral blood. This material needs to be considered when for treating tumor patients and the risks of hematopoietic harm and believe that radiation therapy will be reasonable.

Dose Calculation of Heterogeneous Lung Tissue on 6MV X-ray Therapy (6MV X-선에 의한 폐조직의 심부선량변화와 임상응용)

  • 이경자;장승희;추성실
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.247-257
    • /
    • 1998
  • For effective radiotherapy, it should always be considered that calculation of different dose distribution in heterogenous tissue is important particularly on lung which has low density and large volume. To take precise dose distribution of 6MV X-ray in the thoracic cage, the authors had made a tissue equivalent phantom for thorax, measured dose distribution by thermoluminescent dosimeter and mm dosimeter, and derived methmetical equation coincided with provided theoretical formula. In comparision with isodose curve on case of homogeneous soft tissue, dose of heterogeneous lung tissue had been shown increase about 4% per cm depth on one and multiportal field, less than 15% difference on rotation field for esophagus, and around 20% difference on rotation field for lung according to the degree of rotation angle that must be corrected by dose compensation.

  • PDF

Postoperative Radiation Therapy in the Management of Early Cervical Cancer (초기 자궁경부암의 수술 후 방사선치료의 효과)

  • Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.164-170
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: This study identified the result of postoperative radiation therapy and the prognostic factors to affect survival rates in cancer patients. $\underline{Materials\;and\;Methods}$: One hundred and thirty three patients with cervical cancer who were treated with postoperative radiation therapy following surgery at our institution between June 1985 and November 2002 were retrospectively analyzed. One hundred and thirteen patients had stage IB disease, and 20 patients had stage IIA disease. Histological examination revealed 118 squamous cell carcinoma patients and 15 adenocarcinoma patients. Sixty seven patients were noted to have stromal invasion greater than 10 mm, and 45 patients were noted to have stromal Invasion 10 mm or less. Positive lymphovascular invasion was found in 24 patients, and positive pelvic lymph nodes were noted in 39 patients. Positive vaginal resection margin was documented in 8 patients. All of the patients were treated with external beam radiation therapy to encompass whole pelvis and primary surgical tumor bed. Intracavitary radiation therapy was added to 19 patients who had positive or close surgical margins. $\underline{Results}$: Actuarial overall and disease-free survival rates for entire group of the patients were 88% and 84% at 5 years, respectively. Five-year disease-free survival rates for patients with stromal invasion greater than 10 mm and 10 mm or less were 76% and 97%, respectively (p<0.05). Also there was a significantly lower survival in patients with positive pelvic lymph nodes compared with patients with negative pelvic lymph nodes (p<0.05). However, lymphovascular invasion, positive vaginal resection margins were not statistically significant prognostic factors. Addition of neoadjuvant chemotherapy or type of surgery did not affect disease-free survival. $\underline{Conclusion}$: Postoperative radiation therapy appears to achieve satisfactory local control with limited morbidity in cervical cancer patients with high pathologic risk factors. Distant metastasis was a dominant failure pattern to affect survival in cervical cancer patients after radical surgery and radiation and more effective systemic treatment should be investigated in these high-risk patients.

Development of a Verification Tool in Radiation Treatment Setup (방사선치료 시 환자자세 확인을 위한 영상 분석 도구의 개발)

  • 조병철;강세권;한승희;박희철;박석원;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • In 3-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), many studies on reducing setup error have been conducted in order to focus the irradiation on the tumors while sparing normal tissues as much as possible. As one of these efforts, we developed an image enhancement and registration tool for simulators and portal images that analyze setup errors in a quantitative manner. For setup verification, we used simulator (films and EC-L films (Kodak, USA) as portal images. In addition, digital-captured images during simulation, and digitally-reconstructed radiographs (DRR) can be used as reference images in the software, which is coded using IDL5.4 (Research Systems Inc., USA). To improve the poor contrast of portal images, histogram-equalization, and adaptive histogram equalization, CLAHE (contrast limited adaptive histogram equalization) was implemented in the software. For image registration between simulator and portal images, contours drawn on the simulator image were transferred into the portal image, and then aligned onto the same anatomical structures on the portal image. In conclusion, applying CLAHE considerably improved the contrast of portal images and also enabled the analysis of setup errors in a quantitative manner.

  • PDF

Measurement of Respiratory Motion Signals for Respiratory Gating Radiation Therapy (호흡동조 방사선치료를 위한 호흡 움직임 신호 측정)

  • Chung, Jin-Beom;Chung, Won-Kyun;Kim, Yon-Lae;Lee, Jeong-Woo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.59-63
    • /
    • 2005
  • Respiration motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. Accounting for such motion during treatment, therefore, has the potential to reduce margins drawn around the clinical target volume (CTV), resulting in a lower dose to normal tissues (e.g., lung and liver) and thus a lower risk of treatment induced complications. Among the techniques that explicitly account for intrafraction motion are breath-hold, respiration gating, and 4D or tumor-tracking techniques. Respiration gating methods periodically turn the beam on when the patient's respiration signal is in a certain part of the respiratory cycle (generally end-inhale or end-exhale). These techniques require acquisition of some form of respiration motion signal (infrared reflective markers, spirometry, strain gauge, thermistor, video tracking of chest outlines and fluoroscopic tracking of implanted markers are some of the techniques employed to date), which is assumed to be correlated with internal anatomy motion. In preliminary study for the respiratory gating radiation therapy, we performed to measurement of this respiration motion signal. In order to measure the respiratory motion signals of patient, respiration measurement system (RMS) was composed with three sensor (spirometer, thermistor, and belt transducer), 4 channel data acquisition system and mobile computer. For two patients, we performed to evaluation of respiratory cycle and shape with RMS. We observed under this system that respiratory cycle is generally periodic but asymmetric, with the majority of time spent. As expected, RMS traced patient's respiration each other well and be easily handled for application.

  • PDF

Influence of Social Support for a Cancer Patient undergoing Radiation Treatment on Quality of Life (방사선치료중인 암환자의 사회적 지지가 삶의 질에 미치는 영향)

  • Kim, Sunggil;Ruy, Soyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.145-152
    • /
    • 2016
  • This study, targeting a cancer patient undergoing radiation treatment, conducted this research with the aim of looking into the relevance between family support belonging to a patient's primary environment, social support consisting of medical personnel, and the quality of life; this study set 199 patients available for investigation from Jan. 25, 2012 until April 30, 2012 as research subjects among the cancer patients undergoing radiation treatment at the Radiation Oncology Department of a university hospital located in Seoul Metropolitan City. In the analysis of collected data, this study conducted t-test using SPSS/WIN 18.0 Statistical Program, and looked into the relevancy between independent variables including social support, and the quality of life as a dependent variable using analysis of variance, correlation analysis and multi-regression analysis. Conclusively, it was found that the higher the family support perceived by a cancer patient undergoing radiation treatment, the higher the quality of his/her life; thus, this study could learn that there exists a significant relation between family support and the quality of life. Accordingly, it is thought that it's necessary to develop an intervention strategy which makes it possible to intensify family support and social support, etc. for the purpose of improving the quality of life of cancer patients undergoing radiation treatment; further, this study thinks that it's necessary to do additional research which could analyze diverse aspects by subdividing the future quality of life by area.

Conceptual Design of a Main Control System for CyberKnife (사이버 나이프 주제어 시스템 개념 설계)

  • Choi, You-Rak;Jeong, Gyoeng-Min
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1763-1764
    • /
    • 2015
  • 사이버나이프 시스템은 독특한 형태의 정위적 방사선 치료를 수행하는 로봇 팔을 이용하는 방사선 수술 시스템으로 치료 중 환자의 호흡 등에 따른 신체의 움직임에도 1mm 이내의 오차 범위에서 정확하게 방사선을 조사해야하며, 여러 병소를 동시에 치료할 수 있다. 사이버나이프 시스템은 로봇 팔, 선형 가속기, 병소 위치 추적 장치, 방사선 조사 스케줄러와 같은 다양한 모듈들이 통합된 시스템으로, 이를 통합 제어하기 위한 주제어 시스템이 필요하다. 본 논문에서는 본 연구원에서 개발하고자 하는 사이버나이프 주제어 시스템의 설계에 관하여 기술한다.

The Usability Analysis of 3D-CRT, IMRT, Tomotherpy Radiation Therapy on Nasopharyngeal Cancer (NPC의 방사선치료시 3D-CRT, IMRT, Tomotherapy의 유용성 분석)

  • Song, Jong-Nam;Kim, Young-Jae;Hong, Seung-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.365-371
    • /
    • 2012
  • The radiation therapy treatment technique is developed from 3D-CRT, IMRT to Tomotherapy. and these three technique was most widely using methods. We find out a comparison normal tissue doses and tumor dose of 3D-CRT, IMRT(Linac Based), and Tomotherapy on Head and Neck Cancer. We achieved radiological image used the Human model phantom (Anthropomorphic Phantom) and it was taken CT simulation (Slice Thickness : 3mm) and GTV was nasopharngeal region and PTV(including set-up margin) was GTV plus 2mm area. and transfer those images to the radiation planning system (3D-CRT - ADAC-Pinnacle3, Tomotherapy - Tomotherapy Hi-Art System). The prescription dose was 7020 cGy and measuring PTV's dose and nomal tissue (parotid gland, oral cavity, spinal cord). The PTV's doses was Tomotherapy, Linac Based - IMRT, 3D-CRT was 6923 cGy, 6901 cGy and 6718 cGy its dose value was meet TCP because its value was up to the 95% based on 7020 cGy, Nomal tissue (parotid gland, oral cavity, spinal cord) was 1966 cGy(Tomotherapy), 2405 cGy(IMRT), 2468 cGy(3D-CRT)[parotid gland], 2991 cGy(Tomotherapy), 3062 cGy(IMRT), 3684 cGy (3D-CRT)[oral cavity], 1768 cGy(Tomotherapy), 2151 cGy(IMRT), 4031 cGy(3D-CRT)[spinal cord] its value did not exceeded NTCP. All the treatment techniques are equated with tumor and nomal tissue doses. The 3D-CRT was worse than other techniques on dose distribution, but it is reasonable in terms of TCP and NTCP baseline Tomotherapy, IMRT -dose distribution was relatively superior- was hard to therapy to claustrophobic patients and patients with respiratory failure. Particularly, in case on Tomotherapy, it take MVCT before treatment so dose measurement will be unnecessary radiation exposure to patients. Conclusion, Tomotherapy was the best treatment technique and 2nd was IMRT, and 3rd 3D-CRT. But applicable differently depending on the the patient's condition even though dose not matter.

Evaluation of Dose Distributions Recalculated with Per-field Measurement Data under the Condition of Respiratory Motion during IMRT for Liver Cancer (간암 환자의 세기조절방사선치료 시 호흡에 의한 움직임 조건에서 측정된 조사면 별 선량결과를 기반으로 재계산한 체내 선량분포 평가)

  • Song, Ju-Young;Kim, Yong-Hyeob;Jeong, Jae-Uk;Yoon, Mee Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.79-88
    • /
    • 2014
  • The dose distributions within the real volumes of tumor targets and critical organs during internal target volume-based intensity-modulated radiation therapy (ITV-IMRT) for liver cancer were recalculated by applying the effects of actual respiratory organ motion, and the dosimetric features were analyzed through comparison with gating IMRT (Gate-IMRT) plan results. The ITV was created using MIM software, and a moving phantom was used to simulate respiratory motion. The doses were recalculated with a 3 dose-volume histogram (3DVH) program based on the per-field data measured with a MapCHECK2 2-dimensional diode detector array. Although a sufficient prescription dose covered the PTV during ITV-IMRT delivery, the dose homogeneity in the PTV was inferior to that with the Gate-IMRT plan. We confirmed that there were higher doses to the organs-at-risk (OARs) with ITV-IMRT, as expected when using an enlarged field, but the increased dose to the spinal cord was not significant and the increased doses to the liver and kidney could be considered as minor when the reinforced constraints were applied during IMRT plan optimization. Because the Gate-IMRT method also has disadvantages such as unsuspected dosimetric variations when applying the gating system and an increased treatment time, it is better to perform a prior analysis of the patient's respiratory condition and the importance and fulfillment of the IMRT plan dose constraints in order to select an optimal IMRT method with which to correct the respiratory organ motional effect.

Model Systems in Radiation Biology: Implication for Preclinical Study of Radiotherapy (방사선 생물학을 위한 모델 시스템: 방사선치료의 전임상 연구)

  • Kim, Wanyeon;Seong, Ki Moon;Yang, Hee Jung;Youn, HyeSook;Youn, BuHyun
    • Journal of Life Science
    • /
    • v.22 no.11
    • /
    • pp.1558-1570
    • /
    • 2012
  • In radiation biology, analysis of various mechanisms in response to radiation has been accomplished with the use of model organisms. These model organisms are powerful tools for providing a biologically intact in vivo environment to assess physiological and pathophysiological processes affected by radiation. Accumulated data using these models have been applied to human clinical studies (including the evaluation of radiotherapeutic efficacy) and discovery of radiotherapy reagents. However, there are few studies to provide overall integrated information about these useful model organisms. Thus, this review summarizes the results of radiation biology studies using four well-known model organisms: yeast, Caenorhabditis elegans, Drosophila melanogaster, and mice.