• Title/Summary/Keyword: 한계조건

Search Result 2,140, Processing Time 0.033 seconds

Experimental Study on the Pore Clogging Phenomenon of Porous Concrete (투수콘크리트의 공극막힘현상에 대한 실험적 연구)

  • Nam, Jung-Man;Yun, Jung-Mann;Kim, Seung-Hyun;Song, Young-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4D
    • /
    • pp.577-584
    • /
    • 2011
  • A series of field and laboratory permeability tests were performed to investigate the pore-clogging phenomenon of porous concrete used for pavement materials of a road. The field permeability tests were conducted for 37 study points in Jeju city, using the porous concretes with 13mm of maximum coarse aggregate ($G_{max}$). The results show that the service life of porous concrete is about 22 months when the permeability of the porous concrete is designed for 0.01 cm/sec. Some specimens were made with the purpose of recreating pore-clogging phenomenon. Tests were done for injected concentration of pore-clogging materials or size of maximum coarse aggregates ($G_{max}$). The test results demonstrated that relatively long in service life experienced with small amount of injected concentration of pore-clogging materials, whereas relatively short in service life experienced with a reduction in size of maximum coarse aggregates ($G_{max}$). In conclusion, the service life of porous concrete is in proportion to the concentration of pore-clogging material but it is in inverse proportion to the size of maximum coarse aggregate ($G_{max}$). Thus, the persisting period of porous concrete can be determined with respect to concentration of pore-clogging materials or size of maximum coarse aggregates ($G_{max}$).

A Study on the Optimal Design of Reinforced Concrete Frames Using SUMT (SUMT 법(法)을 이용(利用)한 철근(鐵筋)콘크리트 뼈대구조물(構造物)의 최적설계(最適設計)에 관한 연구(研究))

  • Jung, Young Chae;Lee, Qyu Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.27-48
    • /
    • 1984
  • This study is conserned with the optimization of reinforced concrete frames using limit state design theory. Formulations of the optimal design for reinforced concrete frame based on the limit state theory turn out to be the nonlinear programming problems which have to deal with the required steel area, the width and effective height of the beam and column section and the moment reduction factor as the design variables. The objective function is formulated as the total construction cost which considers the costs of steel, concrete and forming for the reinforced concrete frames, and the basic constraints are imposed upon both ultimate and serviciability limit state concepts. Also, the stress blocks assumpted in CP110 and Hognestad et al. theory are applied to analysis an ultimate resistant section force for the ultimate limit state and only the criteria of CP110 are used for serviciability limit state. The optimized technique which is applied to solve the nonlinear programming problems for the optimization of reinforced concrete frames is SUMT utilizing the modified Newton-Raphson method. This algorithm is used to test for the two reinforced concrete frames, and then is compared and analysized with the numerical results of reference(10) to examine its convergence, applicability and stability under the same conditions. The results of this study are discussed about the economy comparision of the optimal values for CP110 and Hognestad et al., and the applicability, stability, convergence and validity of this algorithm used herein through the numerical analyses.

  • PDF

Determination of Fe(II) ion and Fe(III) ion by Chemiluminescence Method (화학발광법을 이용한 Fe(Ⅱ)이온과 Fe(Ⅲ)이온의 정량)

  • Lee, Sang Hak;Nam, Myeong Sik
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.6
    • /
    • pp.509-514
    • /
    • 2002
  • A method to determin Fe(II) and Fe(III) ion in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of Fe(III) ion to a solution of lucigenin and hydrogen peroxide. The effects of KOH concentration, flow rate of reagents, $H_2O_2$ concentration and citric acid concentration used for the masking of Fe(II) ion on the chemilu-minescence intensity have been investigated. The calibration curve for total Fe was linear over the range from 1.0${\times}$$10^{-6}$ M to 1.0${\times}$$10^{-4}$M, coefficient of correlation was 0.996 and the detection limit was 1.0${\times}$$10^{-7}$M under the optimal exper-imental conditions of 4.0 M, 2.0 M, 3.5 mL/min for the concentration of $H_2O_2,$ KOH and flow rate of reagents, respec-tively. The calibration curve for Fe(Ⅲ) was linear over the range from 1.0${\times}$$10^{-6}$M to 1.0${\times}10^{-4}$ M, the coefficient of correlation was 0.997 and the detection limit was 5.0${\times}$$10^{-7}$M under the optimal experimental conditions.

Consideration on Limitations of Square and Cube Root Scaled Distances in Controled Blast Design (제어발파설계에서 자승근 및 삼승근 환산거리 기법의 적용한계에 대한 고찰)

  • Choi, Byung-Hee;Ryu, Chang-Ha;Jeong, Ju-Hwan
    • Explosives and Blasting
    • /
    • v.28 no.1
    • /
    • pp.27-39
    • /
    • 2010
  • Blast design equations based on the concept of scaled distances can be obtained from the statistical analysis on measured peak particle velocity data of ground vibrations. These equations represents the minimum scale distance of various recommendations for safe blasting. Two types of scaled distance widely used in Korea are the square root scaled distance (SRSD) and cube root scaled distance (CRSD). Thus, the design equations have the forms of $D/\sqrt{W}{\geq}30m/kg^{1/2}$ and $D/\sqrt[3]{W}{\geq}60m/kg^{1/3}$ in the cases of SRSD and CRSD, respectively. With these equations and known distance, we can calculate the maximum charge weight per delay that can assure the safety of nearby structures against ground vibrations. The maximum charge weights per delay, however, are in the orders of $W=O(D^2)$ and $W=O(D^3)$ for SRSD and CRSD, respectively. So, compared with SRSD, the maximum charge for CRSD increases without bound especially after the intersection point of these two charge functions despite of the similar goodness of fits. To prevent structural damage that may be caused by the excessive charge in the case of CRSD, we suggest that CRSD be used within a specified distance slightly beyond the intersection point. The exact limit is up to the point, beyond which the charge difference of SRSD and CRSD begins to exceed the maximum difference between the two within the intersection point.

Estimation of Equivalent Friction Angle and Cohesion of Near-Surface Rock Mass Using the Upper-Bound Solution for Bearing Capacity of Strip Footing (줄기초 지지력 상계해를 활용한 천부 암반의 등가마찰각과 등가점착력 산정)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.25 no.3
    • /
    • pp.284-292
    • /
    • 2015
  • The generalized Hoek-Brown failure criterion, the strength parameters of which are determined by using the GSI index, is an empirical nonlinear failure criterion of rock mass and has been widely employed in various rock engineering practices. Many rock engineering practitioners, however, are still familiar with the description of the strength of rock mass in terms of friction angle and cohesion. In addition, almost all rock mechanics softwares incorporate the simple linear Mohr-Coulomb function. Therefore, it is necessary to provide a tool to implement the Hoek-Brown function in the framework of the Mohr-Coulomb criterion. In this study, the use of upper-bound solution of limit analysis for bearing capacity of a strip footing resting on the ground surface is proposed for the estimation of the equivalent friction angle and cohesion of rock mass incorporating the generalized Hoek-Brown failure criterion. The upper-bound bearing capacity is expressed in terms of friction angle by use of the relationship between tangential friction angle and tangential cohesion implied in the generalized Hoek-Brown function. The friction angle minimizing the upper-bound bearing capacity is taken as the equivalent friction angle. Through the illustrative implementations of the proposed method, the influences of GSI, $m_i$ and D on the equivalent friction angle and cohesion are investigated.

Migration Measurement of Volatile Organic Compounds (VOCs) from Polystyrene-made Food Containers into Distilled Water (폴리스티렌 식품용기로부터 증류수로 용출되는 휘발성유기화합물의 분석)

  • Kim, Nam-Hoon;Kim, Ae-Kyeong;Cho, Tae-Hee;Park, Kyung-Ai;Kwak, Jae-Eun;Kim, Ji-Young;Kim, Il-Young;Chae, Young-Joo;Kim, Min-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.203-208
    • /
    • 2010
  • In this study, the level of migration of 5 kinds of volatile organic compounds (VOCs) (toluene, styrene, ethylbenzene, isopropylbenzene and n-propylbenzene) into distilled water from polystyrene-made food containers was measured using Purge&Trap combined with GC/FID. The contents of the VOCs which have regulatory limits in Korea food code only for material specification were determined under three exposure conditions which were 30 min at $60^{\circ}C$, 30 min at $95^{\circ}C$ and actual situation of instant noodle intake. The calibration curve of 5 compounds showed good linearity ($^r2$ = 0.9976~0.9995) within the concentration range of 1~50 ng/mL. The limit of detection (LOD) and limit of quantification (LOQ) were validated at range of 0.041~0.092 and 0.135~0.304 ng/mL, respectively. The average migration contents of 5 compounds were below 5 ng/mL except for styrene. The average contents of styrene were highly detected at $95^{\circ}C$ for 30 min exposure (52.71 ng/mL). Under actual condition at instant noodle intake, the average contents of styrene was 17.23 ng/mL. The results demonstrated that the migration rate of VOCs was related to storage temperature and time.

A study on the way to improve strength of LTV's FRP structures by optimizing laminated structure (전술차량 FRP 구조물 적층 구조 최적화를 통한 강도개선 방안 연구)

  • Kim, Seon-Jin;Park, Jin-Won;Kim, Sung-Gon;Kang, Tae-Woo;Shin, Cheol-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.468-476
    • /
    • 2019
  • This paper presents the means of improving the strength of LTV's FRP structure for resolve and prevent quality problems. LTV secures enough kerb weight by applying FRP materials at hood and rear van assembly. However, because of FRP's inherent limitations, many initial quality problems such as crack at connections have occurred. Moreover, hood assy' is concerned about fall of endurance, because hood assy' have operated in abnormal condition. Therefore, this study executes lamination structure optimizations of FRP structure for improving bending strength. As a results, hood and rear van's bending strength at connections is improved 8.1 times and 1.5 times, respectively. Also hood assy's plate secures endurance life and improve 1.7 times of critical load about abnormal operating conditions through 1.4 times improvement of bending strength.

Analysis of Hydraulic Characteristics in River Using 3D Geospatial Information (3차원 지형공간정보를 이용한 하천수리특성 분석)

  • Kim, Si-Chul;Lee, Jong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.33-33
    • /
    • 2021
  • 예측하기 어려운 복잡한 기후 변화로 인해 수자원 관리측면에서 다양한 방법을 도입하여 해결할 수 있는 방안이 국가적 주요 관심사로 다루어지고 있다. 따라서 투입인력과 소요시간 절감, 장비와 인력진입 불가지역에 대한 정보획득, 높은 공간해상도, 항공측량 대비 높은 경제성 등 다양한 장점의 드론을 이용한 하천지형 특성별 수리특성 분석방안이 필요하다. 본 연구에서는 성연천 하류부지역을 대상으로 위성항법시스템(Global Navigation Satellite System, GNSS) 측량 지형성과와 드론측량(Drone) 지형성과를 지상에 설치된 CHP(Check Point) 좌표 값을 확인하여 두 지형의 정확도를 비교하였으며 HEC-RAS 모형을 이용하여 빈도별 수리특성을 비교 산정하였다. 본 연구는 성연천 하류 480m구간을 선정하고 GNSS를 이용한 실측지형자료와 GCP(Ground Control Point)를 얻기 위해 정확도 검증을 실시하였으며 위성항법시스템(GNSS) 측량과 DRONE RGB측량의 CHP(Check Point) 오차를 비교하여 정확도를 검증하였다. 오차 값이 확인된 위성항법시스템(GNSS)을 이용하여 가상기준점을 선정하고 RTK 모바일스테이션을 설치하여 DRONE LIDAR측량을 통해 지형자료를 취득하였으며 얻어진 지형자료를 HEC-RAS를 통해 입력 후 성연천 하천기본계획에 제시되어진 조도계수와 빈도별 홍수위를 적용하여 연구구간 480m에 대해 100년 빈도의 결과 값을 비교 검토하였다. 100년 빈도 계획 홍수량 조건의 하상과 한계수위의 차에서 위성항법시스템(GNSS) 측량 지형자료를 기준으로 평균수위 측정오차는 드론 RGB 측량 지형자료 0.460m, 드론 LIDAR 측량 지형자료 0.260m의 결과를 얻었으며 동일 조건 흐름하의 평균유속에서 위성항법시스템(GNSS) 측량 지형자료를 기준으로 평균유속 측정오차는 드론 RGB 측량 지형자료 0.40m/s, 드론 LIDAR 측량 지형자료 0.36m/s의 결과를 얻었다. 통수 단면적의 비교 결과는 위성항법시스템(GNSS) 측량 지형자료를 기준으로 드론 RGB 측량 지형자료 전체 단면의 평균오차는 20.20m2, 드론 LIDAR 측량 지형자료 전체 단면의 평균오차는 21.682의 결과를 얻었으며 이상에서와 같이 홍수위와 평균유속, 통수 단면적의 측정오차 비교 결과를 종합할 때 통수 단면적 측정결과는 위성항법시스템(GNSS) 측량과 드론 RGB 측량의 차이가 적었으나 계획 홍수량 조건의 하상과 한계수위 차이와 동일조건 흐름하의 평균유속에서 위성항법시스템(GNSS) 측량과 드론 LIDAR 측량의 차이가 적은 것으로 나타났다. 그리고 통수용량(capacity)(m3) 비교에서는 위성항법시스템(GNSS) 측량을 기준으로 드론 RGB 측량은 약 7644m3, 드론 LIDAR 측량은 약 7547m3의 차이를 보여 드론 LIDAR를 이용한 결과가 가장 정확한 측정방법으로 추천할 수 있음을 확인하였다.

  • PDF

A Study on the optimum drying condition of sewage sludge cake using continuous microwave full scale dryer (연속적 마이크로파 Full Scale 건조장치를 이용한 하수슬러지 케익의 최적 건조조건 연구)

  • Ha, Sang-An;Jung, Wang-Seok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.2
    • /
    • pp.47-56
    • /
    • 2008
  • The objective of this research is to evaluate the optimum recycling methods for the sewage sludge cakes at different microwave power-settings and for different periods of time. The dehydrated sewage sludge cakes used in this study was obtained from N wastewater treatment plan in the P City. The beginning drying processes were carried out in a microwave oven with 2,450 MHz frequency and power ranges of 1kW to 4 kW. The continuous conveyer drying system was also operated with 2,450 MHz frequency and power setting, ranging from of 1 kW to 6 kW. Initial moisture content of the sewage cake is 78~80%, and the moisture content decreased rapidly up to 0.2~2(wt%) within short periods due to breaking the cell walls. This study is also conducted to evaluate the characteristics of sewage sludge cakes with respect to important physical parameters effect on the thermal kinetics for evaporation water in the sludge which are operation times, moisture contents, drying rates, input amounts, flow rates and calorific values. It takes 60 minutes and 120 minutes to reach the critical moisture contents with power setting of 4 kW for 3kg/min and 6kg/min of the flow rates respectively. It takes 120 minutes and 110 minutes to reach the critical moisture contents with flow rates of 2.5 cm/min and sludge input of 6kg/min for the power settings of 4 kW and 6 kW respectively. The most effective value of the power for drying the sludge is 4 kW. Operation with 6kg/min and 4kW on 2cm of the sludge thickness can be effectively and inexpensively to reach the critical moisture contents, when you compare 2cm of the sludge thickness with 1cm and 3cm of the sludge thickness.

  • PDF

Validation of a Method and Evaluation of Antioxidant Activity for the Simultaneous Determination of Riboflavin and Coixol in Coix lacryma-jobi var. ma-yuen Stapf Sprouts (율무 새싹 추출물의 Riboflavin과 Coixol의 동시 분석법 검증 및 항산화 활성)

  • Lee, Ji Yeon;Park, Jung Yong;Park, Chun-Geon;Kim, Dong Hwi;Ji, Yun-Jeong;Choi, Su Ji;Oh, MyeongWon;Hwang, Hosop;Lee, Yunji;Jeong, Jintae;Lee, Jeong Hoon;Seo, Kyung Hye
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.4
    • /
    • pp.452-458
    • /
    • 2019
  • Coix lacryma-jobi var. ma-yuen (Rom. Caill.) Stapf (CL), which contains riboflavin and coixol, has traditionally been used to treat cancer and arthritis. However, no method for the simultaneous determination of riboflavin and coixol in CL sprouts has been established. In this study, we established and validated a high-performance liquid chromatography-diode array detection (HPLC-DAD) method for the identification and quantification of two reference markers, riboflavin and coixol, in CL sprout extracts. CL sprouts (whole sprouts and leaves) were subjected to extraction with 70% ethanol at room temperature and at 80 ℃ under reflux conditions. The two extractions were validated with respect to specificity, accuracy, precision, and linearity. The content of the two reference markers was highest in leaves extracted under reflux conditions (riboflavin, 8.23 ± 0.32 mg/g; coixol, 5.95 ± 0.04 mg/g). We also investigated the antioxidant activity of the extracts via 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS+) scavenging assays. The results indicated that extracts obtained from sprouts under reflux conditions had the strongest antioxidative effects (DPPH half maximal inhibitory concentration [IC50], 68.9 ± 4.1 g/mL; and ABTS, IC50, 34.9 ± 0.1 g/mL). These results can serve as baseline data for the simultaneous determination of the two reference marker compounds, riboflavin and coixol, and development of functional food materials using CL sprouts.