Effect of the Pipe Joint on Structural Performance of a Single-span Greenhouse: A Full-scale Experimental and Numerical Study (파이프 이음부가 단동온실 구조성능에 미치는 영향: 실대형 실험적 및 해석적 연구)

  • Shin, Hyun Ho;Ryu, Hee Ryong;Yu, In Ho;Cho, Myeong Whan;Seo, Tae Cheol;Kim, Seung Yu;Choi, Man Kwon
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.410-418
    • /
    • 2021
  • This study was conducted in 8.2m wide single-span greenhouse to investigate the effect of presence or absence of rafter steel pipe joint and foundation conditions on greenhouse structural performance. Structural performance was evaluated by static loading test using the structural performance evaluation system for single-span greenhouse. The measured displacement was compared with the predicted result by numerical analysis. The displacement of each measurement location showed a significant difference regardless of the conditions of the foundation and presence or absence of rafter steel pipe joint. Compared to the hinge conditions, the difference in structural performance of the greenhouse in the fixed conditions was seen to be relatively large. The difference in structural performance according to presence or absence of rafter steel pipe joints, the lateral stiffness of the joint was 8.1% greater.

Control of Bending Behavior of Simple Beams Using CTMD (CTMD의 질량비에 따른 단순보의 휨거동 제어효과)

  • Heo, Gwang-Hee;Seo, Sang-Gu;Kim, Chung-Gil;Jeon, Seung-Gon;Kim, Min-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.12-18
    • /
    • 2021
  • The purpose of this study is to effectively mitigate the bending displacement that occurs in the bridge due to forced vibration. We developed CTMD (Combine Tuned Mass Damper) that combines the relationship between spring and mass to control the bending behavior of simple beams. The experiment was conducted to confirm the control effect according to the change in the mass ratio of the developed CTMD. The developed CTMD is designed and manufactured so that the mass ratio can be adjusted according to the characteristics of the bridge. The maximum load of the spring applied to CTMD was fixed at 33.15 N. In order to evaluate the performance of the developed CTMD, a simple beam composed of hinges and rollers as boundary conditions was fabricated. In the experimental method, a CTMD was installed in the center of a simple beam and the deflection displacement according to the mass ratio was measured. The shaking condition was shaken at 3 Hz to induce the maximum bending behavior of the simple beam. As a result of the experiment, it was confirmed that when the optimal mass ratio was 2.1, the damping rate of the bending behavior displacement was about 71.2 %, indicating the best control effect.

A Study on the Evaluation Method to Flexural-bonding Behavior of FRP-Rebar Concrete Member (FRP를 보강근으로 사용한 콘크리트 부재의 휨-부착 거동 평가방법에 관한 연구)

  • Choi, So-Yoeng;Choi, Myoung-Sung;Kim, Il-Sun;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.149-156
    • /
    • 2021
  • FRP has been proposed to replace the steel as a reinforcement in the concrete structures for addressing the corrosion issue. However, FRP-Rebar does not behave in the same manner as steel because the properties of FRP are different. For example, FRP-Rebar has a high tensile strength, low stiffness, and linear elastic behavior which results in a difference bonding mechanism to transfer the load between the reinforcement and the surrounding concrete. Therefore, bonding behavior between FRP-Rebar and concrete has to be investigated using the bonding test. So, Pull-out test has been used to estimate bond behavior because it is simple. However, the results of pull-out test have a difference with flexural-boding behavior of FRP-Rebar concrete member. So, it is needed to evaluate the real fleuxral-bonding behavior. In this study, the evaluation method to flexural-bonding behavior of FRP-Rebar concrete member was reviewed and compared. It was found that the most accurate evaluation method for the fleuxral-bonding behavior of FRP-Rebar concrete member was splice beam test, however, the size and length of specimen have to increase than other test method and the design and analysis of splice beam is complex. Meanwhile, characteristics of concrete could be reflected by using arched beam test, unlike hinged beam test which is based on the ignored change of moment arm length in equilibrium equation. However, the possibility of shear failure exists before the flexural-bonding failure occur.

A Study on the Structural Behavior of FPSO Topside Module by Support Condition (지지조건에 따른 FPSO 상부 모듈의 구조적 거동에 관한 연구)

  • Jang, Beom-Seon;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.18-23
    • /
    • 2018
  • FPSO consists of topside modularized plants for production of crude oil, and hullside structures that serve as support for the topside and storage of produced crude oil. The structural behavior of the FPSO topside module and its supporting hull depends on the interface structure that connects them, and the interface structure consists of a combination of individual unit support structures called Module Support Seat (MSS). Types of interface structures are various and, accordingly, the basic design of the FPSO topside module structure is greatly influenced, so various design methods should be considered from the initial design phase. Structural design of FPSO topside module requires consideration of the number of MSSs, connection type, and structural analysis options such as the range of finite element models, load conditions, and boundary conditions for verification of structural strength. In this study, the comparison combination cases for the above considerations were derived and the strength evaluation was performed, and the structural behavior characteristics of the topside module were compared and analyzed through a detailed review of the analysis results. The results of this study are considered to be a good reference for designing a more reliable topside module structure.

Laboratory Experiments for Evaluating Dynamic Response of Small-scaled Circular Steel Pipe (실내 실험을 통한 소형 모형 원형 강관의 동적 반응 평가)

  • Song, Jung Uk;Lee, Jong-Sub;Park, Min-Chul;Byun, Yong-Hoon;Yu, Jung-Doung
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.11
    • /
    • pp.81-92
    • /
    • 2018
  • For a marine bridge foundation construction, a large-circular-steel-pipe has been proposed for supporting vertical load and preventing water infiltration. However, a ship collision can adversely affect the structural stability. This paper presents a fundamental study on dynamic responses of the large-circular-steel-pipe by an impact load. In laboratory experiments, small-scaled steel pipe is installed in a soil tank. The soil height and water level are set to 23 cm and 25~70 cm, respectively. The upper part of the steel pipe is impacted using a hammer to simulate the ship collision. The dynamic responses are measured using accelerometers and strain gauges. Experimental results show that the strain decreases as the measured location is lowered. The higher frequency components appear in the impact load condition compared to the microtremor condition. However, the higher frequency components measured at the strain gauge located below the water level do not appear. For the accelerometer signal, the maximum frequency under the impact load is higher than that of the microtremor. The maximum frequency decreases as water level increases but it is larger than the maximum frequency of the microtremor. This study shows that strain gauge and accelerometer can be useful for evaluating the dynamic responses of large-circular-steel-pipes.

A Study on the Long-term Settlement Characteristics of Thick Clay Deposits Using Field Monitoring (대심도 연약지반의 현장계측을 이용한 장기침하거동특성 분석에 관한 연구)

  • Kwon, Hyun-Wook;Im, Jong-Chul;Chang, Ji-Gun;Kang, Sang-Kyun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.21-28
    • /
    • 2018
  • Despite a number of studies on consolidation behavior that have been carried out in the Nakdong River estuary in Busan, these are focused on the prediction of final settlement during ground improvement process, and there is almost no research on the long-term settlement occurring after that. For the practical study on the long-term settlement, the field monitored settlement data that measured over 10 years in the Busan new port facilities area were used, and the final settlement and predicted time-settlement line were constituted by hyperbolic function. As a result, the measured settlements depend on the thickness of clayey soils, and the pattern were similar to each other and good agreement with the predicted time-settlement line using hyperbolic method. Also, the settlement in the lower non-improved layer occupied 62-76% of total settlement. Information about above results would be quite helpful to understand the long-term settlement behaviors as well as the non-improved layer's settlement is more careful consideration needed at design phase.

A Study on the Performance Change of Insulation Sheath Due to Accelerated Degradation of IV and HIV Insulated Wire (IV 및 HIV 절연전선의 가속열화에 따른 절연피복의 성능변화에 관한 연구)

  • Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.114-123
    • /
    • 2019
  • The paper relates to a study on the changes in performance of insulation sheath resulting from accelerated degradation of IV and HIV insulated wire. To assume insulation degradation of IV and HIV insulated wire, accelerated life tests using Arrhenius equation were conducted among accelerated life test models, and experimental samples of 0 year, 10 years, 20 years, 30 years, and 40 years in equivalent life were produced. Whereas the maximum tensile load were increased as accelerated degradation of IV and HIV insulated wire progressed, elongation percentage, rupture time, and flexibility of insulated wires were found to be gradually reduced. According to the additional surface analysis results for the insulated wires per equivalent life using a scanning electron microscope, mechanical properties of the insulator were observed to be reduced as insulation degradation resulting from aging progressed since phenomena such as formation of crystalline structures and perforation, etc. occurred on the sample surface with progression of accelerated degradation. Consequently, institutional replacement of insulated wires and preparation of repair times considering performance degradation of the insulator installed inside buildings are considered necessary in order to prevent in advance the risks of electrical fire resulting from degradation in insulation performance.

Analysis of Instances of Characteristics Land Creep on the Mine Area in Korea (우리나라 광산지역에서의 땅밀림 사례 분석)

  • Park, Jae-Hyeon;Park, Seonggyun
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.4
    • /
    • pp.393-401
    • /
    • 2018
  • The aim of this study was to analyze the characteristics of ground subsidence and land-creeping in four mining areas in Korea. Land creeping were occurred by large-scale sinkholes and tensile cracks in the mining areas. This ares showed the shape as large-scale landslides by the collapsed stone debris pushed in the direction of gravity. The rock type in the No. 4 survey area was sandstone and shale, whereas that of other three areas was limestone. The limestone was generally vulnerable to land creeping. The ground subsidence and land creeping in four mining areas were located near the ridge of the mountain. The land creeping by ground subsidence in the mining areas showed complex shapes due to the cavity of underground tunnel and the colluvial debris by gravity in the mountain area, whereas the land creeping in Korea are in the shape of landslide. The average slope of the mining area was ranged from $30.4^{\circ}$ to $33.7^{\circ}$. The values were higher ($1.5^{\circ}{\sim}4.8^{\circ}$) than the average slopes for landslide areas.

Design and Application of Database System for Dynamic Balancing Test of Helicopter Main Rotor Blade (헬리콥터 주로터 블레이드의 동적밸런싱 시험에 대한 데이터베이스 설계 및 적용)

  • Yoon, Byung-Il;Paek, Seung-Kil;Song, Keun-Woong;Kim, Deog-Kwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.8
    • /
    • pp.582-589
    • /
    • 2019
  • The dynamic balancing test of helicopter main rotor blades is a blade rotation test conducted on the ground to make the track of each blade and the load on each pitch rod to a similar level before the flight tests. The purpose of the test is to reduce the vibration occurring on main rotor system as a result of dissimilarity of each blade. The RTB test has been performed for a long period at Whirl Tower Test Facility located in Goheung Flight Centre, accumulating its data. As the amount of the results has become increasingly enormous the needs for the development of database system has been raised to manage the data with effective method. This research aimed to describe the development of Dynamic-Balancing Database System for the RTB test results. For the design of the database system the informations of RTB test results have been categorized into properties, connecting each others according to its logical meaning, and comprised into a database system with relational elements. It has been shown in this paper that the Dynamic Balancing database system enables to effectively accumulate the RTB test data and to be utilized for the data analysis.

One-Dimensional Heat Transfer Model to Predict Temperature Distribution in Voided slabs subjected to fire (화재 시 중공슬래브의 온도분포 예측을 위한 1방향 열전달 모델)

  • Chung, Joo-Hong;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.60-67
    • /
    • 2019
  • In general, a reinforced concrete slabs are known to have a high fire resistance performance due to thermal properties of concrete materials. However, according to previous research, the thermal behavior of voided slabs is reported to be different from that of conventional RC solid slabs, and the differences seem to be caused by the air layer formed inside the voided slab. Therefore, it is difficult to estimate the temperature distribution of the voided slab under fire by using the existing methods that do not take into account the air layer inside the voided slab. In this study, a numerical analysis model was proposed to estimate the temperature distribution of voided slabs under fire, and evaluated. Heat transfer of slabs under fire is generally caused by conduction, convection and radiation, and time-dependent temperature changes of slab can be determined considering these phenomena. This study proposed a numerical method to estimate the temperature distribution of voided slabs under fire based on a finite difference method in which a cross-section of the slab is divided into a number of layers. This method is also developed to allow consideration of heat transfer through convection and radiation in air layer inside of slabs. In addition, the proposed model was also validated by comparison with the experimental results, and the results showed that the proposed model appropriately predicts the temperature distribution of voided slabs under fire.