• Title/Summary/Keyword: 하중이력

Search Result 463, Processing Time 0.023 seconds

A Study on the Stress History and Secondary Compression of Saturated Clays Subjected to Precompression (사전압밀된 포화점토의 응력이력과 2차압밀에 관한 연구)

  • 김형주
    • Geotechnical Engineering
    • /
    • v.10 no.4
    • /
    • pp.167-180
    • /
    • 1994
  • A series of long term consolidation tests were conducted under loading -unloading and loading(pc) -unloading(p.) -reloading(p,) conditions using reconstituted clay in order to investigate the effect of stress history on secondary consolidation characteristics and the applicability of the secondary consolidation model suggested by Bjerrum to overconsolidated clays. According to the test results, the secondary compression settlement affected by the stress history in the first half of experimental period and the coefficient of secondary compression, C‥‥ is dependent on overconsolidation ratio, OCR(p,1 p.), maBium OCR (p./p.), and unloading duration time. Moreover the coefficient of secondary consolidation in the latter half of experimental period Cn is mainly affected by OCR and it gradually reduces with OCR increment. Finally the comparison of the experimental results with the Bjerrum model indicates that the Bjerrum model can be applied beyond certain range of stress history in the overconsolidated clay.

  • PDF

Impact sound analysis on damaged composite laminate (손상이 있는 복합 적층판의 충격음 해석)

  • Kim, Sung-Joon;Jang, Moon-Ho;Sin, Jeong-U;Ahn, Seok-Min;Yeom, Chan-Hong;Hong, Chang-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.465-475
    • /
    • 2010
  • 구조물의 손상을 평가하기 위한 적용되는 태핑 테스트를 효과적이고, 정확하게 사용하기 위하여 적층판의 충격 시 발생하는 현상을 수치적인 방법을 이용하여 해석하였다. 구조물의 진동에 의해 방사되는 음은 구조물의 거동과 직접적으로 연관되므로 충격응답해석이 수행되어야 한다. 본 논문에서는 층간분리가 존재하는 적층판의 해석을 위하여 층간분리 모델을 사용하였으며, 해머 형상의 충격체를 모사할 수 있는 효과적인 스프링-질량모델을 제시하였다. 또한 태핑 테스트 시 방사되는 음압을 Rayleigh 적분식을 이용하여 해석하였다. 예측된 음압이력과 시험결과와 비교하였으며, 음압이력과 충격하중이력에 손상이 주는 영향을 검토하였다. 방사되는 음압과 충격하중이력은 적층판에 존재하는 손상에 영향을 받는 것을 보였다. 결과적으로 제안된 음을 이용한 태핑실험은 복합재에 존재하는 손상을 검출하는데 신뢰성 있는 방법임을 알 수 있었다.

  • PDF

Hysteretic Characteristics of Wooden Frames of Three-Bay-Straw-Roof House under Lateral Cyclic Load (수평 교번하중에 대한 초가삼간 목조 프레임의 이력특성 평가)

  • 서정문;최인길;전영선;이종림;신재철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.3
    • /
    • pp.21-27
    • /
    • 1997
  • In this paper, the hysteretic characteristics of traditional wooden house frame,which is fabricated by Sagaemachum, under cyclic lateral load are presented. Full scale frame models are used in the tests. The skeleton curves of traditional wooden frame are quite different from those of wooden frames which are fabricated using nails or bracings. The equivalent viscous damping ratios of the frame system are about 27% and 13% for ordinary and high-column frames, respectively. The nonlinear hysteretic characteristics of the frame is modeled by the so called Modified Double Target model.

  • PDF

Finite Element Simulation of Hysteretic Behavior of Structural Stainless Steel under Cyclic Loading (반복하중을 받는 스테인리스강의 이력거동 해석모델 개발)

  • Jeon, Jun-Tai
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.2
    • /
    • pp.186-197
    • /
    • 2019
  • Purpose: This study intends to develop a nonlinear cyclic plasticity damage model in the framework of finite element formulation, which is capable of taking large deformation effects into account, in order to accurately predict the hysteretic behavior of stainless steel structures. Method: The new cyclic constitutive equations that utilize the combined isotropic-kinematic hardening rule for plastic deformation is incorporated into the damage mechanic model in conjunction with the large strain formulation. The damage growth law is based on the experimental observations that the evolution of microvoids yields nonlinear damage accumulation with plastic deformation. The damage model parameters and the procedure for their identification are presented. Results and Conclusion: The proposed nonlinear damage model has been verified by simulating uniaxial strain-controlled monotonic and cyclic loading tests, and successfully applied to a thin-walled stainless steel pipe subjected to constant and alternating strain-controlled cyclic loadings.

A Study on the Fatigue Crack Evaluation Method of Railway Bogie Frame (철도차량 대차를 피로균열 평가법 연구)

  • Jun, Hyun-Kyu;Seo, Jung-Won;Lee, Dong-Hyong;Kim, Hyeong-Jin
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.16-24
    • /
    • 2009
  • In this study, fatigue crack growth rate of a cracked railway bogie frame under variable amplitude loading is predicted by applying linear elastic fracture mechanics. For this purpose, we find the critical points by reference surveying on cracked railway bogie frames. And we make an effective load history by synthesizing the dynamic load measured from the critical points of railway bogie frame during commercial line operation and the static load calculated from structural analysis. Crack growth analyses are performed at the 3 critical points under the commercial operation loading condition by assuming an initial crack size as 40 mm. and the results are compared with the experimental results from Japanese railway bogie frame crack growth case. From the analysis results, we find that around 500,000 km operating distance is necessary to bring crack growth from the initial crack to unstable crack. And it takes around 3.8 normal operating years. We conclude that it is enough time to detect the crack between normal maintenance period.

Hysteretic Behavior Characteristics of SM490-TMC Steel Column (SM490-TMC 강재를 적용한 기둥부재 이력거동의 특성)

  • Chang, Kyong Ho;Jang, Gab Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.833-840
    • /
    • 2006
  • In design of steel column member using TMCP steels, hysteretic behavior characteristics of steel column must be clarified. To predict hysteretic behavior of steel column using TMCP steels, a cyclic plasticity model is necessary which can consider the mechanical characteristics and stress-strain relationship of TMCP steels. In this paper, a cyclic plasticity model of SM490-TMC was formulated based on monotonic and cyclic loading tests. The formulated cyclic plasticity model was applied to 3-dimensional finite element analysis. Hysteretic behavior characteristics of steel circular column and H-section column using SM490-TMC was presented by carrying out numerical analysis. Also, influence of SM490-TMC on hysteretic behavior of steel column was presented by comparing analysis results both SM490 and SM490-TMC steel column.

Hysterisis Rules of RC member by Shaking Table Test (진동대 실험에 의한 RC부재의 이력거동)

  • Lee, Dae-Hyoung;Yang, Dong-Wook;Baek, Min-Chul;Hong, Hyun-Ki;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.9-10
    • /
    • 2009
  • The object of this research is to investigate the hysteresis rules of RC members by shaking table test. These hysteresis rules are essential to verify of safety under earthquake excitation. The effect of mass was investigated in stiffness of hysteresis rules.

  • PDF

The Estimation of the Floor Vibration in Structure for Application of Response Spectrum Analysis Method (응답스펙트럼 해석법을 이용한 건축 구조물의 바닥진동해석)

  • 이동근;김태호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.169-178
    • /
    • 1998
  • In general, the response spectrum analysis method is widely used for seismic analysis of building structures, and the time history analysis is applied for computation of structural vibration caused by equipments, machines and moving loads, etc. However, compared with the response spectrum analysis method, the time history method is very complex, difficult and time consuming. In this study, the maximum responses for the vertical vibration are calculated conveniently by the response spectrum method. At first, Response spectrum and time history analysis for some earthquake excitations are carried out, and the accuracy of maximum displacements obtained from response spectrum analysis is investigated. Secondly, the process for the response spectrum analysis in excitation is calculated, and the maximum modal responses are combined by CQC method. Finally, results of the proposed method are compared with those of the time history analysis.

  • PDF

Dynamic Response Analysis of Superstructures on Very Large Floating Structures (초대형 부유식 구조물의 상부구조체에 대한 동적응답해석)

  • Kwak, Myung-Ha;Song, Hwa-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.26 no.4
    • /
    • pp.441-447
    • /
    • 2002
  • The importance of utilization of ocean space is increased due to high population and narrow land space. The development of a new technology for future use of ocean space, such as a design technology of Very Large Floating Structures(VLFS) is needed. This paper introduces the rime history analysis of superstructures on very large floating structures and proposes the estimation method of time displacement history considering wave loads. The dynamic responses of superstructure according to variation of period and amplitude are analysed using an example frame structure and the dynamic structural safety of VLFS pilot superstructure is evaluated.

Experimental Study of Characteristics of Longitudinal Resistance Behavior of Fasteners in Concrete Track on Bridges (교량 상 콘크리트궤도 체결장치의 종저항 거동특성에 대한 실험적 연구)

  • Yun, Kyung-Min;Park, Beom-Ho;Min, Kyung-Hwan;Lim, Nam-Hyoung
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.5
    • /
    • pp.638-646
    • /
    • 2016
  • CWR (continuous welded rail) tracks on high-speed railway bridges have much more complicated axial force distributions caused by track-bridge interaction than those behaviors on embankments, and additional problems caused by track-structure interaction with the axial force of the CWR. In order to analyze and limit other physical phenomena caused by track-bridge interaction, a design guideline (KR C-08080, longitudinal track-bridge interaction analysis) is used when designing CWR track on bridges. Domestic analysis and design methods for track-bridge interaction follow the UIC 774-3R, and they suggest conservative methods and deterministic properties. Recently, many studies analyzing the methods of track-bridge interaction considering the loading history are being carried out; however, there has been insufficient studies of the variation of the resistance properties with a consideration of the actual loading history. In this study, the performances of rail fastening systems used for concrete track on bridges were tested and analyzed while considering the loading history. For this purpose, longitudinal and vertical loading combinations, applied in order to simulate the practical conditions and resistance characteristics (stiffness and elastic limit displacement), are analyzed through the experimental results. Also, a comparison study was conducted with the properties in the KR Code.