• Title/Summary/Keyword: 하중감소계수

Search Result 304, Processing Time 0.042 seconds

Stress Distribution in Concrete Pavements under Multi-Axle Vehicle Loads Obtained Using Transformed Field Domain Analysis (변환영역 해석법을 통한 콘크리트 도로 포장의 다축 차량 하중에 대한 응력 분포 분석)

  • Kim, Seong-Min;Shim, Jae-Soo;Park, Hee-Beom
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.695-702
    • /
    • 2006
  • The stress distribution and the critical stresses in concrete pavements were analyzed using formulations in the transformed field domains when dual-wheel single-, tandem-, and tridem-axle loads were applied. First the accuracy of the transformed field domain analysis results was verified by comparing with the finite element analysis results. Then, the stress distribution along the longitudinal and transverse directions was investigated, and the effects of slab thickness, concrete elastic modulus, and foundation stiffness on the stress distribution were studied. The effect of the tire contact pressure related to the tire print area was also studied, and the location of the critical stress occurrence in concrete pavements was finally investigated. From this study, it was found that the critical concrete stress due to multi-axle loads became larger as the concrete elastic modulus increased, the slab thickness increased, and the foundation stiffness decreased. The number of axles did not tend to affect the critical stress ratio except for a small foundation stiffness value with which the critical stress ratio became significantly larger as the number of axles increased. The critical stress location in the transverse direction tended to move into the interior as the tire contact pressure increased, the concrete elastic modulus increased, the slab thickness increased, and the foundation stiffness decreased. The critical stress location in the longitudinal direction was under the axle for single- and tandem-axle loads, but for tridem-axle loads, it tended to move under the middle axle from the outer axles as the concrete elastic modulus and/or slab thickness increased and the foundation stiffness decreased.

Stress Distribution of Concrete Pavements under Multi-Axle Vehicle Loads Applied at Pavement Edges (모서리부 차량 다축하중에 의한 콘크리트 도로 포장의 응력 분포 특성)

  • Kim, Seong-Min;Cho, Byoung-Hooi;Lee, Sang-Hoon
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.13-24
    • /
    • 2006
  • The stresses in concrete pavement systems are larger when vehicle loads are applied at pavement edges, and these large stresses significantly affect the behavior and performance of pavements. Therefore, in this study, the stress distribution and the critical stresses in concrete pavements were investigated using a finite element model when dual-wheel single-, tandem-, and tridem-axle loads were applied at pavement edges. First, the stress distribution along the longitudinal and transverse directions was analyzed, and then the effects of slab thickness, concrete elastic modulus, and foundation stiffness on the stress distribution were investigated. The effect of the tire contact pressure related to the tire print area was also studied. The location of the critical stress occurrence in concrete pavements was finally investigated. From this study, it was found that the critical concrete stress due to edge loads became larger as the concrete elastic modulus increased, the slab thickness increased, and the foundation stiffness decreased. The effect of the tire contact pressure on the critical stress was clear as the slab thickness became smaller. The critical stress location in the transverse direction was independent of the concrete elastic modulus and the foundation stiffness; however, it moved into the interior as the slab thickness increased. The critical stress location in the longitudinal direction was under the axle for single- and tandem-axle loads, but for tridem-axle loads, it tended to move under the middle axle from the outer axles as the concrete elastic modulus and/or slab thickness increased and the foundation stiffness decreased.

  • PDF

Parametric Study on Lateral Vibration Model of Steel Sheet Pile (강널말뚝의 횡방향 진동모델에 대한 매개변수 연구)

  • Lee, Seung-Hyun;Kim, Byung-Il;Kim, Zu-Cheol;Kim, Jeong-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1047-1052
    • /
    • 2010
  • Influence of lateral spring constant on energy dissipation and load reduction factor with erespect to lateral vibration of steel sheet pile installed by vibratory pile driver. Energy dissipation and load reduction factor varying with free length of steel sheet pile are more affected by eccentricity than flexural rigidity of steel sheet pile regardless of the magnitudes of lateral spring constants. Load reduction factors were converged when lateral spring constant was equal or larger than 10000N/m.

Calibration of Load and Resistance Factors in KCI Code Based on Domestic Data (국내 통계자료를 이용한 설계기준의 하중저항계수 검증)

  • Kim, Jee-Sang;Kim, Jong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.495-501
    • /
    • 2011
  • The load combinations in current KCI Design Code are determined with reference to those in ACI 318-05, which adopts the LRFD (load and resistance factor design) format. The load and resistance factors in LRFD format should be determined to meet the required levels of reliability index or probability of failure for various predetermined failure modes, which are also based on the statistical data reflecting locality and contemporary situation. However, the current KCI Design Code has been written utilizing foreign data, because of insufficiency in accrued data in Korea. This study considered the current safety levels of KCI Code based on published domestic data to evaluate appropriateness of the current KCI regulations. Based on the calibrated reliability index of the existing Code, the new resistance factors are suggested. The results presented in this paper can be considered as a basic research for establishment of unique design format for future Korean Codes.

A Study on the Fatigue Strength Reduction Factor under the High Cycle Bending Fatigue (고사이클 굽힘 피로에서의 피로강도 감소계수에 관한 연구)

  • Pyo, Dong-Keun
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 1992
  • 기구나 구조물의 피로수명은 노치에서의 피로균열 방생수명에 의하여 지배되기때문에 노치로 인한 피로강도감소계수 $K_f$는 피로설계상 대단히 중요한 인자이다. 노치 선단(Notch root)에서의 피로균열발생명수 N$_c$를 기준으로하면 탄성응력집중계수 $K_t$가 10 정도까지 $K_f$$K_t$간에는 거의 직선적인 관계가 있음이 이다- 고에 의하여 명석해졌으나 이는 인장,압축의 축력이 작용하였을 때이며 따라서 기구나 구조부재는 축력외에도 굽힘 피로 하중이 작용하였을때도 많으므로 본 연구에서는 굽힘 피로 하중을 받았을때도 있다. -고의 결론이 적용되는지는 검시코져 본 연구를 실시하였다.

  • PDF

A Study on the Effect of Lateral Vibration of Sheet Pile on Vibratory Driving Force (널말뚝의 횡방향진동이 진동타입력에 미치는 영향에 대한 연구)

  • Lee, Seung-Hyun;Kim, Byoung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.848-852
    • /
    • 2007
  • Many numerical analysis tools for predicting penetration speed of sheet pile are thought to be unreliable because they overestimate penetration speed for shallow depth of penetration. In order to overcome the defects of numerical analysis, lateral vibration model of sheet pile was suggested and energy consumption due to lateral vibration of sheet pile was estimated. Also, load reduction factor which explains reduction of vibratory driving force due to lateral vibration was introduced.

  • PDF

A Study on the Evaluation of the Loads Acting on the Pillar in Two-Arch Tunnel (2-Arch 터널 중앙벽체 작용하중 산정에 관한 연구)

  • Oh, Gyoo-Chul;Chun, Byung-Sik;Do, Jong-Nam
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.11
    • /
    • pp.5-14
    • /
    • 2007
  • In this study, Matsuda formula used to evaluate the loads acting on the pillar was investigated and load reduction factor(${\alpha}$) was evaluated by numerical analysis to better apply for the design. From the results, normal stress was concentrated to one side due to excavation of preceding tunnel after construction of pillar. And 86.5% of maximum normal stress was revealed partly unequally when the ground was poor. By numerical analysis, $14{\sim}83%$ of total loads calculated by Matsuda formula decreased and then, from these results, load reduction factor(${\alpha}$) was estimated. From now on, stability and economic aspects could be guaranteed by applying the load reduction factor(${\alpha}$).

Analysis of dynamic downpull force on underflow type floating gate (부력식 수문의 동적 하향력 분석)

  • Lee, Ji Haeng;Han, Il Yeong;Choi, Heung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.78-78
    • /
    • 2018
  • 자동수문이란 설정된 관리수위 이하에서는 수문이 개방되지 않고, 유량이 증가하여 관리수위 이상이 되면 수문이 개방되어 관리수위까지 방류하게 되면 다시 수문이 닫히게 되어 자동으로 관리수위를 유지한다는 것을 의미한다. 이러한 연직 자동수문의 방류특성이 수동식 연직수문과 다른 점은 유량에 따라서 수문 개방고의 증감과 수문개폐가 자동으로 이루어진다는 것이다. 따라서 자동수문의 운영 중 수문개방고의 거동과 자동개폐 시점을 예측하는 것은 정밀한 수문설계를 위해 매우 중요하다. 수문 개방 시 흐름이 정지되어있다고 가정하면, 정수압 상태의 부력이론에 의한 부력수문의 개방고는 어렵지 않게 계산할 수 있다. 그러나, 흐름이 정지되어 있다가 수문의 하단으로 방류가 시작되면 수문 선단을 포함한 주변에 압력 차이로 인해 동수압 하중이 발생하게 되어 수문에 진동을 유발하고, 수문개방을 억제하는 힘이 발생하여 수문 운영에 큰 영향을 미친다. 본 연구에서는 부력식 수문의 모형실험을 통하여 정수압 상태의 부력이론에 의한 수문 개방율과 측정에 의한 수문 개방율을 비교하였으며, 압력계수를 이용하여 이론과 측정 수문 개방고의 차이는 동적하중에 의한 효과임을 확인하였다. 모형실험에서 측정된 자료와 수치모형 ANSYS - Fluent의 사용성을 검증하였고, 부력식 수문의 형상에 따른 동적하중을 분석하였다. 수문 형상비는 0.24~1.09로 설정하였고, 분석결과 부력식 수문은 수문 개방율이 커짐에 따라 압력계수는 감소하는 경향을 보였으며, 동적하중은 증가하는 경향을 보였다. 또한, 부력식 수문의 형상비에 따라서는 형상비가 증가함에 따라 동적하중이 감소하는 관계를 확인하였다.

  • PDF

Probabilistic Analysis of Lifetime Extreme Live toads of Multi-Story Columns (고층기둥 축하중의 사용기간 최대값 분석)

  • 김상효;조형근;배규웅;박홍석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1990.10a
    • /
    • pp.69-72
    • /
    • 1990
  • The live loads acting on structures are generally computed in terms of equivalent uniformly distributed loads for the simplicity in design process. The loads, therefore, tend to decrease with increasing influence area in both load intensity and variance. Since multi-story column loads result from accumulation of loadings acting on several different floors, its influence area becomes wider and lifetime maximum decreases. In the design codes proposing the design loads for types of structural members (i.e., slabs, beams, columns), not for tile change of influence area, some proper reduction factors are given for columns which support more than one floor. Using the live load models developed for colons supporting single floor, in this study, the probabilistic characteristics of multi-story column loads are analyzed. In addition reduction factors given for multi-story columns in current practice are calibrated.

  • PDF