• Title/Summary/Keyword: 하이브리드 환기

Search Result 38, Processing Time 0.6 seconds

A Prediction of Hybrid Ventilation System Performance in Apartment House (공동주택 하이브리드(Hybrid) 환기시스템의 성능예측)

  • Hwang, Ji-Hyeon;Oh, Chang-Yong;Choi, Hung-Won;Kim, Moo-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.33-38
    • /
    • 2005
  • A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, 120 $m^3/h$. As the results, residents feel comfortable thermally and in air flow conditions for 60 $m^3/h$. But the case of 30 $m^3/h$ shows 1100ppm of $CO_2$ concentration due to the deficient of air flow rate. In the case of 120 $m^3/h$, however, residents feel uncomfortable thermally and in air currents. In this study the energy saving for space heating is also an important factor. A detailed prediction for more complicated whole apartment space will be investigated in the future.

  • PDF

An Application Study on a Strategy to Promote Natural Ventilation at an Atrium Building (아트리움을 이용한 자연환기 활성화 방안에 관한 사례 연구)

  • Shin, Seon-Joon;Lee, Seung-Yeon;Jo, Jin-Kyun;Han, Soo-Gon;Hong, Min-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.540-545
    • /
    • 2008
  • An atrium has great potential in natural ventilation aided by buoyance effect. Architectural design of an atrium is very critical to maximize the effect. However, it is not easy of an atrium to have optimum shape for natural ventilation, from the aesthetic and economic point of view. Admitting this condition, we suggested a strategy to promote natural ventilation, which can be adopted only with small design change. At first, we installed BIPV on the top of an atrium to strengthen buoyancy effect, and combine forced ventilation by low pressure fan. To evaluate the performance of the measure, CFD simulation and Energy-Airflow analysis were achieved.

  • PDF

An experimental study on performance evaluation for development of compact steam unit applied with hybrid plate heat exchanger (하이브리드 판형 열교환기 적용 컴팩트 스팀 유닛 개발을 위한 성능 평가에 관한 실험적 연구)

  • Park, Jae-Hong;Cho, Sung-Youl;Lee, Jun-Seok;Lee, Sang-Rae;Kim, Seung-Hyun;Lim, Gye-Hun;Seo, Jung-Wan;Kim, Jeung-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.296-301
    • /
    • 2017
  • In various industrial places such as power generation plants, petrochemical and unit factories, the demands of systems that produce hot water by utilizing wasted or surplus steam have been increased. Compact steam unit(CSU) is a system that can meet these demands and produce hot water by using surplus or wasted steam, and it is also one of the good solutions in view of energy reuse. The new CSU with a capacity of 1,600 kW was developed with a hybrid plate heat exchanger of which thermal performances are better than a conventional plate heat exchanger, an improved temperature control valve, a user-friendly control system, and other components in this study. The purpose of this study was to obtain performance data of the new CSU through various experiments and utilize them for the CSU commercialization. The experimental results show that heat balances between the hot side(steam) and the cold side(cold water) were within ${\pm}0.77%$, and the fluctuations of outlet temperature of the secondary side which are one of the most important evaluation factors in the CSU were $(0{\sim}0.3)^{\circ}C$.

A Proposal of Hybrid Cooling System Coupled with Radiation Panel Cooling and Natural Ventilation (자연환기와 복사냉방을 병용한 하이브리드 시스템의 제안)

  • 송두삼
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.543-550
    • /
    • 2003
  • In order to saving the energy for HVAC system of buildings, utilization of wind-induced cross ventilation is thought to be promising. However, utilization of natural ventilation alone is not sufficient for maintaining the human thermal-comfort such as in hot and humid regions. A hybrid air conditioning system with a controlled natural ventilation system, or combination of natural ventilation with mechanical air conditioning is thought to overcome the deficiency of wind-driven cross ventilation and to have significant effects on energy reduction. This paper describes a concept of hybrid system and propose a new type of hybrid system using radiational cooling with wind-induced cross ventilation. Moreover, a radiational cooling system is compared with an all-air cooling system. The characteristics of the indoor environment will be examined through CFD (Computational Fluid Dynamics) simulation, which is coupled with a radiation heat transfer simulation and with HVAC control in which the PMV value for the human model in the center of the room is controlled to attain the target value.

Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer (하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가)

  • Kim, Sang-Jin;Kim, Eun-Soo;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

A Study on the Risk Assessment and Mitigation Plan about Fire Explosion of n-Pentane in EPS Process (EPS공정에서 발생하는 n-Pentane의 화재폭발에 대한 위험성평가 및 위험성 완화 대책에 관한 연구)

  • Seo, Min Su;Kim, Ki Sug;Kim, Bo Min;Kang, Dong Cheon;Kang, Kil Jae;Chon, Young Woo
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.39-46
    • /
    • 2018
  • 최근 전자제품 생산업체에서 EPS를 직접생산하게 되면서 EPS 공정이 증가하고 있다. EPS에는 펜탄이 포함되어 있으며, 펜탄은 하이브리드 혼합물로 구분할 수 있어 높은 화재폭발의 위험성을 가지고 있다. 각 공정별 펜탄의 누출률은 발포기, 사일로실, 저장실 순이나 발포기의 경우 일반적으로 밀폐되어 있으므로 사일로 실이 가장 화재폭발 위험성이 높다고 판단하였다. 사일로실의 누출률 중 70%는 사일로 상단을 통해 누출되며, 사일로 상단을 통해 누출되는 펜탄의 거동을 분석하여 사일로실 위험성 완화대책을 수립하였다. 1. 폭발위험구역 2종으로 관리, 2. 사일로상단 50cm이내 환기설비 설치 또는 Push-Pull 구조의 환기설비설치, 3. 사일로 하단 1.4m이내에 가스감지기 설치, 4. 60%이상의 습도유지

Design and Implementation of a Hybrid-Type Mass Flow Controller (하이브리드형 질량 유량 제어기의 설계 및 실현)

  • 이명의;정원철
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.2
    • /
    • pp.63-70
    • /
    • 2003
  • In this paper, an MFC (Mass Flow Controller) which is widely used in many semiconductor manufacturing processes for controlling the mass flow rate of a gas is designed and implemented using the PIC 16F876 of Microchip, Inc. The MFC implemented in this thesis has the form of hybrid-type, i.e., the mixed-type of the analog-type MFC, which has many problems such as low accurary, and digital-type MFC, which use an expensive DSP (Digital Signal Processor) and an ADC (Analog to Digital Convertor) with high precision. The MFC is consists of the sensor unit, the control unit and the actuator unit, and it has used the automatic calibration algorithm and the reference table method for the improvement of the performance.

  • PDF

Performance Evaluation of the Hybrid Defrost Process in the Fin-Tube Evaporators of Refrigerators (하이브리드 제상 방식을 적용한 냉장고용 핀-관 열교환기의 제상 성능 평가)

  • Lee, Su-Won;Park, Yong-Joo;Kweon, Lae-Un;Jeong, Young-Man;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.38-46
    • /
    • 2011
  • The hybrid defrost process combined with hot-gas bypass defrost and electric heater defrost was experimentally evaluated about its defrost performance in the fin-tube evaporators of household refrigerators. Also the hybrid defrost process was compared with only electric heater defrost process. The defrost efficiency of the hybrid defrost process was shown two times higher than electric heater defrost process. The defrost time of the hybrid defrost process was shorten about 10%~50% than electric heater defrost process. Thermal shock after defrost process was decreased about 50% for the case of the hybrid defrost. It was found that energy consumption ratio of defrost process was reduced up to 7.4% compared with 22.4% of electric heater defrost at the condition of $25^{\circ}C$ ambient temperature.