하이브리드 강제환기장치의 작동기준 및 설치위치에 관한 고찰

  • Kim, Nam-Gyu
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.38 no.9
    • /
    • pp.10-16
    • /
    • 2009
  • 하이브리드 환기설비 중 강제환기팬은 일반 강제환기방식처럼 팬의 용량은 [강 중 약]의 3단계로 운전이 가능하도록 규정하고 있다. 수동 및 자동환기를 위해 일부 환기업체를 중심으로 $CO_2$ 센서를 설치하여 공동주택의 실내환경 기준 농도인 1,000 ppm을 기준으로 자동으로 작동이 가능하도록 하고 있으며 $CO_2$ 센서는 controller에 내장하고 있다. 이때 환기팬이 자동으로 작동하기 위한 적절한 $CO_2$ 농도 및 $CO_2$ 센서의 적정위치에 대해 검토하고자 한다.

  • PDF

A Study on the Performance of the Hybrid Ventilation System for Apartment Houses (공동주택의 하이브리드 환기시스템 성능평가 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sang-Hee
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study was to evaluate the applicability of hybrid ventilation system in apartment housings and present a design method to improve the performance of hybrid ventilation system using the CFD simulation. As the object of CFD simulation, a small apartment houses with area of $51m^2$ and $81m^2$ were selected and evaluated. The test hybrid ventilation system are window frame natural air supply & duct exhaust hybrid system(Hybrid 1) and window frame natural air supply & bathroom and livingroom exhaust hybrid ventilation system(Hybrid 2). To evaluate the ventilation efficiency, we used the locations of diffuser installed for each system as the variables through the CFD simulation. In the case of Hybrid 1, the ventilation efficiency of the exhaust duct diffuser located on the inside room was higher rather than the exhaust duct diffuser located on the entrance. In the case of Hybrid 2, the most efficient system was the system that the diffuser connecting the bathroom static pressure fan is installed on the center of the living room. The ventilation efficiency of the Hybrid 2 in the case of $51m^2$ type was more than 20% of the Hybrid 1. But, The ventilation efficiency of the Hybrid 2 in the case of $84m^2$ type was more than 14% of the Hybrid 1. Therefore, to apply the Hybrid ventilation, a study that considers various variable should be conducted.

A Study of Hybrid Ventilation System applying to an Apartment House (공동주택용 하이브리드 환기설비에 관한 연구)

  • Yi, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1137-1143
    • /
    • 2006
  • The purpose of this research lays on examining the adequacy of the hybrid ventilation system. The hybrid ventilation system must satisfy the next to be used. Firstly, the cold-draft phenomenon must not exist in the occupied zone. Secondly, the condensation must not happen on the surfaces of vents. Thirdly, the flow of make-up air must be happened in an each space by exhausted air of a rest room and living room. We used an examination and CFD method to verify these. Trough the examination of air-vents, We confirmed that the cold-draft to be induced by make-up air does not happen and could not find the condensation in the limits of outdoor temperature higher than 265K. Through CFD simulation, We confirmed that the rapid temperature change existed only within 0.5m the occupied zone and the flow of air was happened in an each space by only exhausted air in the rest room and living room. Consequently, the hybrid system is possible method to an apartment house.