• Title/Summary/Keyword: 하이드로싸이클론

Search Result 9, Processing Time 0.031 seconds

Classification of Lake Sediment by Hydrocyclone (Hydrocyclone을 이용한 호소 퇴적물의 분급특성)

  • No, Seong-Hyeok;Jo, Yeong-Min;O, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.3
    • /
    • pp.265-273
    • /
    • 2001
  • In this study, a hydrocyclone operated by centrifugal force was examined as a part of dredge system of lake sediments. It does not help dehydration of the sediments, but also enables the classification of fine particles in the stable and sanitary treatment. Several experiments were performed focusing on the separation efficiency under the condition of room temperature with virtual sediment samples and simulated particles. As a result of the experiment, it was found that the apex size of the cyclone greatly affected the cut diameter(d$_{50}$), and high density particles were separated more effectively.y.

  • PDF

A Study on the Solid-Liquid Separation of Cooling Water in Ships (선박용 냉각수의 고.액분리에 관한 연구)

  • Choi, M.S.;Kim, J.H.;Jo, D.H.;Han, W.H.;Kim, B.G.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.25-30
    • /
    • 2003
  • Hydrocyclone has been widely used for the solid-Liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range panicle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested solid methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the seperating performance of the Hydrocyclone were investigated. The results from the study are summarized as follows: 1) In proportion to the increase of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in ships, and eventually prevent unexpected accidents in engine systems.

  • PDF

Recovery of Valuable Materials from Gold Mine Tailings (금(金) 광산(鑛山) 광미(鑛尾)로부터 유가자원(有價資源) 회수(回收)에 관한 연구(硏究))

  • Oh, Won;Cho, Hee-Chan;Lee, Jin-Soo
    • Resources Recycling
    • /
    • v.19 no.6
    • /
    • pp.77-85
    • /
    • 2010
  • This study was carried out to develop a process flow sheet for recovering valuables (gold and high purity silica) from the gold mine tailings containing 1.7 g/ton of gold and 79.48 wt.% $SiO_2$. Float-sink tests using heavy liquids was conducted to explore the possibility of recovering gold by gravity separation. Hydrocyclone, froth flotation, and triboelectrostatic separatoin tests were conducted to recover high purity silica from the gold mine tailings. The results of float-sink tests showed that particles containing 5.58 g/ton of gold could be obtained at 2.72 specific gravity, but with very low yields around 3%. Meanwhile, all tests with hydrocyclone, froth flotation, and triboelectrostatic separation showed that high purity silica with $SiO_2$ content over 90% could be obtained. The purity could be improved further up to about 94% by employing several recleaning steps in the froth flotation and triboelectrostatic process.

The Recycling of Sludge from Granite Stone Cutting and Polishing (화강암 석재 가공 슬러지의 재활용)

  • 이성오;국남표;임영빈;신방섭
    • Resources Recycling
    • /
    • v.4 no.1
    • /
    • pp.12-19
    • /
    • 1995
  • This study was carried out to remove the iron and impurities usmg hydrocyclone and HGMS for recycling of sludge from the granite stone cutting and polishing industrγ in the basic of chemi떠1 analysis and minerallogical investigation. This sludge consist of 70.9% $SiO_2$ 13.6% $Al_2O_3$ and It also contained 2.52% of $Fe_2O_7$ and 0.29% of $TiO_2$, as a main impurities to decrease the whiteness. As the result of hydrocyclone experiment, It was very good condition that are 100~150 g/l of sludge amount, 2.0~ 2.5 mm of underflow nozzle size, and 1.2~1.6 kg/$\textrm{cm}^2$ of pressure for 85% sludge product with the $-37{\mu}\textrm{m}$ size. $Fe_2O_3$ and $TiO_2$, contents by treatment of HGMS were decreased with 0.65% and 0.07% each at 10,000 gauss of magnetic field strength, and addih$\upsilon$n of Sodium tripolyphosphate as a dispersant was effected to get low grade F Fe,Ol and TiO, concentrate. PhYSIcal properties of this stone sludge product were showed 58.5% of whiteness, 1 13.4% of firing shrinkage and 3.0812 $\textrm{m}^2$/g of specific surface area.

  • PDF

Removal Efficiency of Settleable Solids in Seawater Aquaculture Farm Wastewater (하이드로싸이클론을 이용한 해수 양식장 침전 고형물의 제거 효율 평가)

  • Junhyuk Seo;Pyongkih Kim;Jeonghwan Park
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.1
    • /
    • pp.116-123
    • /
    • 2023
  • Flow-through aquaculture systems generate large amounts of wastewater containing compounds such as solids that can settle near aquafarms and cause eutrophication. The settled solids are often reintroduced into flow-through systems, and aquatic animals can be affected by the solids and pathogens associated with these solids. For a sustainable aquaculture operation, adequate wastewater treatment is required. Hydrocyclones are one of the most promising technologies for the removal of solids in aquaculture wastewater. In this study, a model for performance prediction of hydrocyclones was investigated under three different operating conditions: water temperature, solids concentration, and water inlet velocity. The synthetic solids solution was prepared using settled solids from abalone aquaculture farms. The daily solids removal rates of the tested hydrocyclones ranged from 0.18 to 26.0 g solids-m-3-day-1, and removal efficiency ranged from 5.1 to 34.4%. The inlet water velocity had the greatest effect on solids removal and hydrocyclone efficiencies. The following multiregression model equation was derived from the daily solids removal rate (g solids-m-3-day-1) results for water temperature (T, ℃), solids concentration (SS, mg-L-1), and tangential inlet water velocity (TIV, m-sec-1): daily solids removal rate: f(z)=4.465+0.809TIV-0.375T+0.217SS (r2=0.976).

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

Treatment of Dredging Suspended Solids Using Chitosan Coagulant (Chitosan 응집제를 이용한 준설토 부유물질 처리)

  • Lee, Jun-Ho;Yang, Seung-Ho;Shin, Yiung-Kyewn;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.834-846
    • /
    • 2011
  • The objective of this study is to development of IDFIS system, that are consisted of hydrocyclone, rapid flocculation and inclined settler with chitosan coagulant. As the results of Jar test, a chitosan optimum dosage of 40 mg/L for river sediment, and 5 mg/L for tunnelling wastewater sediment, which these conditions leaves of residual turbidity of less than 5 NTU. Because of the effectiveness of chitosan in removing turbidity was independent on pH, the operation of IDFIS system would be simple. The synthesized turbidity was made with clay particles, river sediment, river suspended sediment, and tunnelling wastewater sediment. Results indicate that the mean overall removal efficiency of turbidity, SS, COD and TP were 98%, 99%, 85% and 95%, respectively. Chitosan is very efficient in removing turbidity in the entire turbidity range examined. IDFIS system would have possibility with compact design, because of the increase of floc size favours the floc settling speed and reduces the settling time.