• 제목/요약/키워드: 하수 재이용

검색결과 287건 처리시간 0.028초

제주지역 하수처리수의 농업용수 재이용 안전성 평가 (Safety Evaluation of a Wastewater Reuse for the Farmland Irrigation in Jeju Island)

  • 손영권;이한필;김해도;최선화;김정대
    • 한국농공학회논문집
    • /
    • 제57권4호
    • /
    • pp.21-29
    • /
    • 2015
  • Safety of reclaimed wastewater irrigation needs to be evaluated to promote public health. Quantitative microbial and toxic risk assessment was conducted to identify the level of risk for farmland workers who use reclaimed wastewater and groundwater in Jeju island. Microbial risk through inhalation and ingestion exposure was below acceptable level (less than $10^{-3}$) of $7.07{\times}10^{-6}$ for reclaimed wastewater and $9.99{\times}10^{-8}$ for groundwater irrigation worker. Aggregate exposure risk of Ni, As and Cu was most contributable to overall risk in both reclaimed wastewater and groundwater irrigation plot. High cumulative exposure risk was estimated through non-dietary soil ingestion and dermal contact of soil, due to the high concentration of As, Cu and Ni in farmland soil. Overall toxic risk was $2.68{\times}10^{-4}$ for reclaimed water and $2.39{\times}10^{-4}$ for groundwater irrigation, which could not meet acceptable toxic risk level of $10^{-6}$. Further efforts, such as provide personal protective equipments or public health education, need to be implicated to reduce adverse health risk.

유역차원의 하수처리수 재이용 대안평가와 우선순위 결정과정에 관한 연구 (A Study on Evaluation and Prioritization Process of Wastewater Reuse Alternative in Watershed Level)

  • 정은성;전상묵;이진희;안종호
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.259-269
    • /
    • 2013
  • This study aims to show the feasibility of wastewater reuse through hydrological analysis and propose a framework for planning using multi-criteria decision making technique. Ten alternatives of wastewater reuse (BOD: 3.0 mg/L & 4.7 mg/L) and two references in the urban watershed were considered and analyzed by using Hydrological Simulation Program in Fortran (HSPF). Though wastewater reuse has a positive effect on water quantity, it may degrade the water quality due to the high discharge concentration. This study showed that wastewater reuse can be a great alternative for the rehabilitation of distorted water cycle, if the quality is improved up to the natural streamflow and the quantity is increased up to the instreamflow requirement. In addition, to determine the project priority, three criteria were compared: 1) impacts on water quantity and water quality, respectively, 2) consideration of present hydrologic vulnerabilities on water quantity and quality and not, and 3) social and economic considerations and not. From the performance values to all criteria, the specific ranking can be derived and the feasibility of each wastewater reuse project can be checked with the comparison of the existing facilities. As a result, DJ and DR were derived to become effective in any evaluation conditions while SS and WG were improper alternatives if various criteria were considered. The decision making for project prioritization must be careful with the consideration of various impacts of wastewater reuse because the evaluation of wastewater reuse alternative showed very different priorities for each criteria.

농업적 용수재이용을 위한 간헐분사 완속모래여과 하수재처리 효율 평가 (Feasibility Study of Intermittent Slow Sand Filtration for Agricultural Reuse of Reclaimed Water)

  • 윤춘경;정광욱;함종화;황하선
    • 한국농공학회지
    • /
    • 제45권5호
    • /
    • pp.160-170
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of intermittent slow sand filtration for agricultural reuse of reclaimed water. The effluent of biofilter for 16-unit apartment was used as influent to the slow sand filtration system at 0.6 $m^3$/day loading rate using 15 seconds spray in every 10 minutes on the about 1 $m^2$ surface area and 0.5 m depth. The influent concentrations of total coliform (TC), fecal coliform (FC) and E. coli were in the range of 10.000 MPN/100 mL. and they were reduced to less than 1,000 MPN/100 mL after filtration with average of 320, 270, and 154 MPN/100 mL, respectively, showing over 95 % removal. Turbidity and SS were improved effectively and their average concentration was reduced to 0.8 NTU and 1.7 mg/L, respectively, and removal rate was about 50 %. Average BOD and COD concentrations were also reduced substantially to 2.6 and 25.8 mg/L with about 55 and 21 % removal rate, respectively. Nutrients removal was relatively low and removal rate for T-N and T-P was low however, remaining nutrients might be beneficial and less concerned in case of agricultural reuse. The concentration of biofilter effluent used in this experiment was in the range of secondary treatment effluent but slightly stronger than the one from existing wastewater treatment plants (WWTPs). Therefore, intermittent slow sand filtration might be also applicable to the effluent from WWTPs as long as its agricultural reuse is available. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, the intermittent slow sand filtration was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper is a preliminary result from pilot study and further investigations are recommended on the optimum design parameters before full scale application.

자동차 연료탱크 모듈의 재활용성 평가 (Recyclability Estimation of Fuel Tank Module in Vechicle)

  • 이철민;이은옥;김하수;이준수;강희용;양성모
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.127-135
    • /
    • 2006
  • We analyzed recyclability of the fuel tanks made from steel or aluminum alloy. For a comparison of the fuel tank recyclability, first we had analyzed the process of disassembly in a vehicle and evaluated its disassemblability. Then we evaluated the recyclability for reuse and withdrawal. The processes were more or less same owing to the similarity of fastening method of fuel tank and components. However, the fuel tank of the aluminum alloy was easier (about 5%) to disassembly than the fuel tank of steel. This could be attributed to the differences in weight of steel and aluminium. On light of the withdrawal and reuse, the fuel tank made up of steel needed to plate with zinc or lead due to its anti-corrosiveness. Hence, it required additional processes. In this paper, we were explaining the results of our on going research on the recyclability of fuel tanks made of steel and aluminum alloys. The differences that we found between the fuel tank made up of the aluminum alloy and steel were in their weight, recyclability, disassemblability, anticorrosive property, cost and productivity.

소규모 하수 재이용을 위한 디스크필터의 처리 효율 증진에 관한 연구 (Enhancement of Discfilter Removal Efficiency for Small-scale Wastewater Reclamation)

  • 최낙철;김봉주;박성용;박형우;이성재;박천영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권4호
    • /
    • pp.66-72
    • /
    • 2015
  • The aim of this study was to enhance of the Discfilter process (maximum treatment capacity - 500 ton/day) removal efficiency for small-scale wastewater reclamation under various influent wastewater conditions (with / without coagulation process, coagulant content and temperature). The result of chemical resistance test for fiber filter in the Discfilter that weight loss was obtained with 0.535% under pH 3, 0.092% under pH 9 and 0.028% under 10% NaClO. The removal efficiency test of Discfilter process on the with / without coagulation process showed that with coagulation process condition was occurred CODMn of 42.26 ± 0.61, BOD5 of 88.72 ± 0.44, T-P of 84.67 ± 0.72 and SS of 90.58 ± 0.61. The removal efficiency of Discfilter process on the coagulant content (4.5, 5.0 and 5.0 mL/min) and temperature (< 10℃, 10℃~ 20℃ and > 20℃) conditions were increased as coagulant content and temperature increased. This study demonstrated the potential application of Discfilter process for small-scale wastewater reclamation.

생물학적 처리수 재이용을 위한 전기화학 기술의 적용 (Application of Electrochemical Technology for Reusing Biologically Treated Water)

  • 강구영
    • 대한환경공학회지
    • /
    • 제30권4호
    • /
    • pp.453-458
    • /
    • 2008
  • 본 연구는 생활하수 최종처리수의 색도, 잔류 유기물질 제거 및 소독에 관한 연구를 Nb/Pt Anode 전극으로 구성된 전기분해장치를 이용하여 수행하였다. RNO는 OH$\cdot$에 의하여 빠르게 탈색시키며, 전류세기 5 A, 10 A, 15 A에서 RNO의 2차 분해속도는 각각 $\frac{0.223l}{mg{\cdot}min}$, $\frac{1.679l}{mg{\cdot}min}$, $\frac{2.322l}{mg{\cdot}min}$로 96% 이상의 r$^2$ 조사되었다. 회분식 전기분해장치에서 전류세기 15 A와 초기 pH 5, 7.5, 9일 때 15분 후 COD$_{Mn}$ 농도는 4 mg/L 미만, 색도는 5도 미만, 일반세균은 불검출로 먹는물 수질 기준값으로 조사되었다. 전기분해 연속 시스템의 HRT 3.7$\sim$49.2분에서 유리염소는 0.2$\sim$0.7 mg/L, 일반세균은 불검출, 색도는 5도 미만과 THMs는 0.017 mg/L이다. 그러므로 Nb/Pt anode 전기분해 공정은 소독뿐만 아니라 생물학적 처리수의 재이용 기술로 적용될 수 있다.

무기성 폐기물 첨가제 혼합에 따른 하수슬러지의 용융특성 (Characteristics of Melting Slag Using Sewage Sludge by Inorganic Additives)

  • 배정석;이상원;차재환;김효수;김창원
    • 대한환경공학회지
    • /
    • 제30권11호
    • /
    • pp.1116-1122
    • /
    • 2008
  • 기존의 하수슬러지 소각재를 용융하여 경량 골재로 재활용하는 기술은 물성이 일정하지 않으며, 또한 하수슬러지만 소각 용융한 경우에는 물성이 경량골재 기준을 만족하지 못해 사용이 제한적인 실정이다. 따라서 본 연구에서는 30%의 함수율을 가진 건조 하수슬러지를 대상으로 굴 패각, 폐 주물사, 쇠의 녹과 같은 무기성 폐기물 첨가제를 이용해 CaO/SiO$_2$, SiO$_2$/Al$_2$O$_3$, Fe$_2$O$_3$/SiO$_2$비를 조절하여 낮은 용융온도에서도 균일한 품질의 골재용 슬래그를 생산하고자 하였다. 1,400$^{\circ}C$에서 20분간 용융하였을 때, 굴패각 첨가실험에서는 CaO/SiO$_2$ 비 1.00, 폐 주물사 첨가 실험에서는 SiO$_2$/Al$_2$O$_3$ 비 3.0 그리고 쇠의 녹 첨가 실험에서는 Fe$_2$O$_3$/SiO$_2$비 0.6에서 밀도가 각각 2.24 g/cm$^3$, 2.45 g/cm$^3$, 2.73 g/cm$^3$였으며, 24시간 수 흡수성은 각각 4.72%, 1.44%, 0.37%로 가장 우수한 슬래그 생산이 가능한 것으로 판단되었다. 폐기물 첨가제를 첨가한 용융슬래그를 생산함으로써 자원순환 및 환경오염 방지 효과가 기대된다.

지하수댐 활용방안에 관한 연구 (A Study on the Application of Groundwater Dam)

  • 이규민;김진수
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.489-489
    • /
    • 2018
  • 최근 기후변화의 영향으로 가뭄의 발생빈도 및 규모가 증가하고 있다. 이에 지자체를 중심으로 대체 수자원 확보를 목적으로 지하수의 개발이 늘어나고 있는 추세이다. 국내에서는 지하수 개발 이용시설로 관정(管井)을 활용하는 것이 일반적이나, 최근에는 낙도를 중심으로 대규모 지하수자원 확보를 위한 지하수댐 건설이 논의되고 있다. 현재 우리나라에는 6개의 지하수댐이 설치 운영되고 있는데, 가장 최근에 건설된 지하수댐도 20여 년이 지난 1998년에 건설되었다. 게다가 국내에 건설된 지하수댐은 지하수맥을 이용하기 보다는, 건천화된 시기에도 하천수를 이용하기 위해 하천의 지하에 건설되어 있어 일반적인 개념의 지하수댐이라고 보기 어렵다. 지하수댐의 활용을 통해 지하수자원을 효율적으로 확보하기 위해서는 첫째, 지하수에 대한 기초자료의 확보가 필요하다. 현재 지하수법 제5조에 따라 전국 지하수에 대한 기초조사를 실시하고 10년마다 보완조사를 실시하여야 한다. 그러나 1997년부터 실시되고 있는 기초조사는 예산 및 인력 부족 등으로 아직까지 전국 전체에 대한 자료가 마련되지 못하고 있으며, 보완조사는 아직까지 실시된 바가 없는 실정이다. 조속히 지하수 기초조사를 완료하여 전국에 대한 수문지질도(水文地質圖)를 작성하고, 이를 바탕으로 체계적인 지하수댐 조성계획을 수립할 필요가 있다. 둘째, 지하수댐 건설기술에 대한 체계적인 연구가 필요하다. 현재 조성된 하천 지하에 건설된 지하수댐이 아닌, 지하수맥을 이용하는 본래의 용도에 적합한 지하수댐을 건설하기 위한 세부기술의 확보가 필요해 보인다. 셋째, 현행 지하 충전수에 대한 수질기준을 확대할 필요가 있다. 현재 하수 폐수 및 온배수 재처리수로 지하수를 함양할 경우의 수질기준은 시 도지사가 관할 구역에 대하여 수립하는 '지역지하수관리계획'에 포함된 경우로만 되어 있어, 국가 또는 개인이 지하수를 함양할 경우에 적용되는 수질기준이 부재한 상태다. 또한 지하수 충전 깊이에 따라 토양에서 발생하는 정화능력에 차이가 있으므로, 수질기준에 차등을 두어 합리적으로 적용할 필요가 있다.

  • PDF

조건부가치평가법을 활용한 공공사업의 경제적 타당성 분석 (An Economic Feasibility Analysis of A Public Project Using Contingent Valuation Method)

  • 김종대;조문기
    • 자원ㆍ환경경제연구
    • /
    • 제14권1호
    • /
    • pp.101-134
    • /
    • 2005
  • 정부가 시행하는 환경정책등의 공공사업에 대한 경제적 타당성 분석은 그 성격이 영리 조직과는 질적으로 다르다. 공공사업의 경제적 타당성 분석에서 고려되어야 할 편익(benefit)으로는 계량적으로 측정할 수 있는 경제적 편익뿐만 아니라 시장에서 평가할 수 없는 공익적 편익까지도 고려되어야만 사업시행 여부에 대한 정확한 타당성 분석이 이루어질 수 있다. 그러나 시장가격이 존재하지 않는 공익적 편익의 추정은 매우 어렵다. 본 연구의 목적은 구미시의 하수관거정비 사업의 경제적 타당성 분석의 사례를 통해 보다 정확하고 엄밀한 타당성 분석 모델을 제시함에 있다. 이를 위해 시장에서 평가할 수 없는 환경보전이나 생활환경개선 등과 같은 공익적 편익을 경제학 분야에서 널리 이용되고 있는 조건부가치평가법(Contigent Valuation Method : CVM)을 이용하여 추정하였다. 조건부가치평가법(CVM)에 의해 추정된 구미시 하수관거정비 사업에 대한 주민들의 가구당 월평균 지불의사액(willing-to-pay : WTP)은 2,865원으로 추정되었다. 추정된 생활환경개선 편익을 경제적 타당성 분석에 포함시켜 분석한 결과, 구미시 전체의 편익/비용 비율(B/C Ratio)은 0.97로 1보다 작은 것으로 나타났다. 본 연구는 조건부가치평가법(CVM)을 활용하여 공공사업에 대한 경제적 타당성 분석의 전형적인 모형을 처음으로 제시하였다는 점에서 향후 공공사업의 시행여부에 대한 정책적 의사결정과 학문발전에 크게 기여할 것으로 기대된다.

  • PDF

전기화학적 방법을 이용한 Spent Granular Activated Carbon (GAC)의 재생 연구 (A Study of the Regeneration of Spent GAC using an Electrochemical Method)

  • 이상민;주수빈;조영수;오예지;김형준;심인태
    • 대한토목학회논문집
    • /
    • 제42권4호
    • /
    • pp.481-491
    • /
    • 2022
  • 본 연구는 CSOs의 고도처리를 목적으로 다단 횡류식 여과와 GAC 흡착조의 융합공정의 운영에서 GAC 흡착조의 유기물 처리 특성을 조사하고 설계 파과점에 도달한 GAC를 전기화학적 방법을 통한 재생효율을 평가하는 것이다. 여과공정은 부유물질은 용이하게 제거되지만 용존 유기물이 제거되지 않아 CSOs의 고도처리를 위해서는 용존유기물질의 제거능이 추가로 필요하다. 일반적으로 GAC 흡착은 정수처리 공정이나 하수의 3차 처리공정과 같은 저농도 유기물 조건에서 적용되어왔고 하수나 CSOs와 같이 유기물 농도가 높은 조건에서는 거의 적용이 되지 않았기에 본 연구에서 GAC를 이용한 CSOs 처리는 흥미로운 경험을 제공할 것이다. 본 연구는 유입 유기물 강도에 따른 GAC의 연속 운전 및 파과 특성을 조사하고 사용된 GAC를 전기화학적 재생을 적용하였으며, 이때 전압강도 및 전해액이 종류에 따른 흡착 유기물의 탈착 특성을 조사하였고 재생 후 GAC의 재흡착실험을 통해서 재생효율을 평가하였다. GAC 연속 운전결과 파과기간은 고농도 조건에서 21일, 중농도에서 28일 그리고 저농도에서 32일을 나타내었다. 전기분해를 통한 흡착 유기물의 탈착은 전기 분해 조건에 따라 188~609 mgCOD/L까지 발생하였고 전해액 종류의 영향은 NaOH가 H2O2보다 조금 우수한 탈착 특성을 나타냈다.