• 제목/요약/키워드: 하수월류수

검색결과 48건 처리시간 0.022초

합류식 하수관거 월류수 처리를 위한 섬유사 여과 장치의 처리특성 (Performance of fiber media filter device for combined sewer overflows treatment)

  • 손상미;주티담롱판;박기영;박철휘
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.231-236
    • /
    • 2010
  • A compressible media filtration process with synthetic fiber media was studied for combined sewer overflows (CSOs) treatment. Since the operation performance of fiber media filtration was dependent on the pattern of CSOs, the flow rate of CSOs was investigated and it was characterized by a big fluctuation. Thus, in this study, the fiber media filtration process was tested with wide range of filtration velocity. The removal efficiency was proportion to the increase in compressibility. As the filtration velocity was increased, the treatment efficiency was decreased and consequently leveled off when the velocity exceeded 750 $m^3/m^2$/d. An exponential equation was introduced to express the relationship between the removal efficiency and up-flow velocity. At columm test, six repetition of filtration and backwash cycle did not after the filtering velocity under the constant pressure condition.

입경분포 분석을 활용한 합류식 하수관거 월류수(CSO) 오염물질 침강성 예측 (Application of Particle Size Analysis to Predict the Settleability of CSO Pollutants)

  • 윤현식;이두진;박영숙
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.295-302
    • /
    • 2006
  • Over the past decades, a flocculation and/or sedimentation process have been adopted to remove pollutants from CSOs. It has been learned that major factors affecting settlement of pollutants are the particle size distribution, their settling velocities and their specific gravity. It is, therefore, a good idea to analyze the particle size distribution and settleability of CSOs pollutants in order to develop details in designing a process. Discussed in this study are pollutant characteristics of CSOs such as particle size distribution and settleability of pollutants. The power law function is applied and is found to be an effective and reliable index for expressing the particle size distribution of pollutants in CSOs. Based on the regression analysis it is observed that the derived constants of curves representing settling velocity profile are proportional to the initial concentration of particles and to the ${\beta}$-values of power law distributions.

분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어 (Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO)

  • 백현욱;류재나;김태형;오재일
    • 한국지능시스템학회논문지
    • /
    • 제22권6호
    • /
    • pp.722-728
    • /
    • 2012
  • 도심지역의 하수관거 시스템은 우수 수용능력 및 하수 월류 발생 등의 시스템의 한계점을 가지고 있어, 강우시 우수 유출수로 인한 침수저감과 더불어 도시비점오염원의 저감에 모두 대응할 수 있는 저류시설의 도입이 주목받고 시작하였다. 최근 환경부에서는 방재적 우수관리와 더불어 합류식 하수관거 월류수, 분류식 우수관거 유출수 처리를 포함하는 다기능 저류시설을 "하수저류시설"이라 통칭하고, 이의 도입을 적극 추진하고 있는 실정이다. 반면 대규모 단일 저류시설 설치의 경우에는 공간 확보의 문제가 발생할 수 있으며, 이에 대안으로는 중 소규모의 분산형 저류시설 설치 및 운영을 들 수 있다. 본 연구에서는 분산형 저류시설-하수관망 네트워크 시스템의 최적 운용을 위한 모델 예측 제어기법을 제안한다. 이를 위해 첫째로 네트워크 시스템의 각 구성 요소의 수리모델을 제시함으로써 보다 정밀한 하수관망 네트워크의 거동을 모사하고자 한다. 둘째로 제안된 모델을 기반으로 현재의 강우 유입량을 고려하여 각 저류조의 수위, 하수관로의 유입/유출량을 예측하여, 입자군집 최적화 알고리즘을 이용한 모델 예측 제어기법을 바탕으로 주어진 제약조건을 만족하며 상황을 바탕으로 제안된 제어기법의 사용여부에 따른 효과를 비교 분석하고, 이의 타당성을 검증하고자 한다.

합류식 하수관거 월류수 유입 기간 동안에 나타나는 청계천 수질 변화 모델 연구 (A Water Quality Modeling Study of Chunggye Stream during Combined Sewer OverFlow Period)

  • 이혜숙;박석순
    • 대한환경공학회지
    • /
    • 제27권12호
    • /
    • pp.1340-1346
    • /
    • 2005
  • 소수계 물관리 진단시스템, CREEK-1을 이용하여 합류식 하수관거 월류수 발생시 청계천에서 나타나는 수질변화에 관한 모델 연구를 수행하였다. CREEK-1은 지리정보시스템, 데이터베이스, 경관생태모델(FRAGSTATS), 유역모델(SWMM), 수질모델(WASP5), 그리고 컴퓨터 그래픽으로 구성되어있다. 본 연구에서는 강우시 청계천의 수질변화를 시뮬레이션하기 위해 유역모델과 수질모델이 주로 사용되었다. 유역모델에서 청계천 전체 유역이 18개의 소유역으로, 수질모델에서 대상 하천 구간은 11개의 구획으로 나누어져 모델이 구성되었다. 유역모델은 강우시 현장에서 관측된 BOD, 총질소, 총인 그리고 유량 자료로 타당성이 검토되었으며, 그 결과 모든 항목에서 모델 예측같은 관측값과 비교적 적절한 일치를 보였다. 연구 결과는 하천의 수질이 강우량과 강우 시작 후 경과 시간에 따라 변화가 일어나고 있음을 보여주었다. 강우 초기에는 유역의 초기 세척수와 CSO에서 차지하는 하수 비율이 높기 때문에 수질이 크게 악화되었으나 유출 수량이 증가함에 따라 희석효과에 의해 수질이 개선되는 것으로 나타났다.

합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석 (Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system)

  • 박진규;이남훈;김해룡;이웅;이채영
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.

목감천 유역의 CSOs를 포함한 물순환 모의 (Hydrologic Cycle Simulation of Mokgam Watershed including CSOs)

  • 이길성;홍원표;정은성;김경태
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.1459-1463
    • /
    • 2007
  • 도시 유역의 하수관거는 대부분 합류식 하수관거로 되어 있기 때문에 도시하천의 물순환을 모의하기 위해 수량적인 측면이나 수질적인 측면에서 강우시의 합류식 하수관거 월류수 즉, CSOs를 고려한다면 보다 정확한 모의가 가능할 것이다. 목감천 유역은 중 상류 지역의 대부분은 농경 또는 임야로 이용되고 있지만, 하구부에는 밀집된 시가지가 전체유역 면적의 약 35.2 %인 $18.66\;km^2$를 형성하고 있고, 이중 대부분이 합류식 하수관거로 되어 있다. 따라서 목감천 유역을 PCSWMM의 TRANSPORT 블럭내의 flow divider를 이용하여 모형을 구성하여 1996년부터 2005년까지 10년 동안의 연속유출모의를 실시하여 물순환 분석을 하였다. 결과를 보면 10년 평균 강수량은 1537.9 mm이며, 직접유출량 비율은 1,263.0 mm, 침투량은 335.7 mm, 증발량은 415.7 mm이다. 또한 10년 평균 상수량은 909.10 mm, 하수량은 736.3 mm(CSOs 355.0 mm), 하천유입하수량은 170.3 mm, 서남 및 역곡하수처리장 이송량은 211.0 mm이다. 부하량 결과를 살펴보면 발생부하량은 10,108,554 kg/year이며 배출부하량은 834,533 kg/year으로, 이는 곧 점오염원을 의미한다. 유역 총 배출량은 1,575,200 kg/year, 비점오염원은 740,667 kg/year, 하수처리장 이송부하량은 1,220,000 kg/year, 목감천 출구지점에서는 355,200 kg/year(CSOs 62,531 kg/year)임을 알 수 있었다.

  • PDF

소독제 농도, pH, 온도, 암모니아 농도, 부유물질이 강우 월류수 염소 소독에 미치는 영향 (Effects of Disinfectant Concentration, pH, Temperature, Ammonia, and Suspended Solids on the Chlorine Disinfection of Combined Sewer Overflow)

  • 김상현
    • 대한환경공학회지
    • /
    • 제36권10호
    • /
    • pp.685-690
    • /
    • 2014
  • 하수처리시설 초과유량에 대한 처리 규제 입법 예고로 인해 강우 월류수 처리에 대한 관심이 증가하고 있다. 본 연구에서는 강우 월류수 염소(차아염소산나트륨) 소독 시 소독제 농도(0.11-4.0 mg $Cl_2/L$), pH (6.5-8.0), 온도($15-25^{\circ}C$), 암모니아 농도(10-41 mg N/L), 부유물질(91-271 mg SS/L)이 대장균군수 감소 속도에 미치는 영향을 고찰하였다. 차아염소산나트륨 농도 효과는 반속도 상수가 1.212mg $Cl_2/L$인 saturation-type model로 잘 모사되었다. 소독 반응 속도는 SS와 pH 증가에 따라 감소되는 반면, 온도에 따라서는 증가하였고, 암모니아 농도에는 영향을 받지 않았다. 월류수 유입 조건을 $1{\times}10^5MPN/mL$, 271 mg SS/L, $15^{\circ}C$, pH 8.0로 가정할 때, 염소 주입 농도 1 mg/L, 수리학적 체류시간 1.25 분인 염소 소독조를 통해 입법예고 된 수질 기준의 1/3 수준인 대장균군수 1,000개/mL를 달성할 수 있을 것으로 계산되어, 염소 소독이 강우 월류수 소독에 유효하게 사용될 수 있을 것으로 판단된다.

합류식 하수관거내 우오수분리벽 설치에 따른 부유물질 제어효과 (Effect of separation walls on reduction of suspended solids loading in a combined sewer system)

  • 권충진;임봉수
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.787-796
    • /
    • 2012
  • The purpose of this study is to investigate CSOs(combined sewer overflows) control in the combined sewer with/without separation wall. There is the high correlation between sewage velocity and suspended solid(SS) loading in the sewer without it. The SS/BOD ratio was about 3 times in the area with it, while it was about 5 times in the area without it. Therefore, the accumulated deposit within the sewer has influenced high SS loading in the sewer without it. This study showed that the separation wall installed acquired an acceptable efficiency in controlling the accumulated deposit in the combined sewer. According to this study, the BOD control effect was about 38 % in the sewer with the separation wall, whereas it showed about 24 % in the sewer without it. In this case, it was anticipated that the high pollutant control effect would be expected if the separation wall was installed in the combined sewer.