• Title/Summary/Keyword: 하수월류수

Search Result 48, Processing Time 0.023 seconds

Performance of fiber media filter device for combined sewer overflows treatment (합류식 하수관거 월류수 처리를 위한 섬유사 여과 장치의 처리특성)

  • Son, Sang-Mi;Warangkana, Jutidamrongphan;Park, Ki-Young;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.231-236
    • /
    • 2010
  • A compressible media filtration process with synthetic fiber media was studied for combined sewer overflows (CSOs) treatment. Since the operation performance of fiber media filtration was dependent on the pattern of CSOs, the flow rate of CSOs was investigated and it was characterized by a big fluctuation. Thus, in this study, the fiber media filtration process was tested with wide range of filtration velocity. The removal efficiency was proportion to the increase in compressibility. As the filtration velocity was increased, the treatment efficiency was decreased and consequently leveled off when the velocity exceeded 750 $m^3/m^2$/d. An exponential equation was introduced to express the relationship between the removal efficiency and up-flow velocity. At columm test, six repetition of filtration and backwash cycle did not after the filtering velocity under the constant pressure condition.

Application of Particle Size Analysis to Predict the Settleability of CSO Pollutants (입경분포 분석을 활용한 합류식 하수관거 월류수(CSO) 오염물질 침강성 예측)

  • Yoon, Hyun Sik;Lee, Doojin;Park, Young Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.295-302
    • /
    • 2006
  • Over the past decades, a flocculation and/or sedimentation process have been adopted to remove pollutants from CSOs. It has been learned that major factors affecting settlement of pollutants are the particle size distribution, their settling velocities and their specific gravity. It is, therefore, a good idea to analyze the particle size distribution and settleability of CSOs pollutants in order to develop details in designing a process. Discussed in this study are pollutant characteristics of CSOs such as particle size distribution and settleability of pollutants. The power law function is applied and is found to be an effective and reliable index for expressing the particle size distribution of pollutants in CSOs. Based on the regression analysis it is observed that the derived constants of curves representing settling velocity profile are proportional to the initial concentration of particles and to the ${\beta}$-values of power law distributions.

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.

A Water Quality Modeling Study of Chunggye Stream during Combined Sewer OverFlow Period (합류식 하수관거 월류수 유입 기간 동안에 나타나는 청계천 수질 변화 모델 연구)

  • Yi, Hye-Suk;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1340-1346
    • /
    • 2005
  • A water quality modeling study was performed for Chunggye stream during combined sewer overflow(CSO) period, utilizing the diagnostic system for water management in small watershed, CREEK-1(Cyber River for Environment and Economy in Korea). This system integrated geogaphic information system, data base, landscape ecological model(FRAGSTATS), watershed model(SWMM), water quality model (WASP5), and computer graphic. In this study, the watershed model and water quality model were extensively utilized so as to simulate water qualities and flow in Chunggye stream during wet periods. The Chunggye stream watershed was divided into 18 sub-basins in the watershed model and the stream reach into 11 segments in the water quality model. The watershed model was validated against field measurements of BOD, TN, TP, and flow at the downstream location, where the model results showed a reasonable agreement with the field measurements at all parameters. From this study, it was shown that the stream water quality would change along with elapsed time from rainfall start as well as rainfall intensity. The model results indicated that the water quality would significantly upgrade due to the first flush and high sewage ratio of CSO at the beginning of rainfall event, but become degraded along with the runoff increase due to dilution effect.

Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system (합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석)

  • Park, Jin-Kyu;Lee, Nam-Hoon;Kim, Hae-Ryong;Lee, Woong;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.

Hydrologic Cycle Simulation of Mokgam Watershed including CSOs (목감천 유역의 CSOs를 포함한 물순환 모의)

  • Lee, Kil-Sung;Hong, Won-Pyo;Chung, Eun-Sung;Kim, Kyung-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1459-1463
    • /
    • 2007
  • 도시 유역의 하수관거는 대부분 합류식 하수관거로 되어 있기 때문에 도시하천의 물순환을 모의하기 위해 수량적인 측면이나 수질적인 측면에서 강우시의 합류식 하수관거 월류수 즉, CSOs를 고려한다면 보다 정확한 모의가 가능할 것이다. 목감천 유역은 중 상류 지역의 대부분은 농경 또는 임야로 이용되고 있지만, 하구부에는 밀집된 시가지가 전체유역 면적의 약 35.2 %인 $18.66\;km^2$를 형성하고 있고, 이중 대부분이 합류식 하수관거로 되어 있다. 따라서 목감천 유역을 PCSWMM의 TRANSPORT 블럭내의 flow divider를 이용하여 모형을 구성하여 1996년부터 2005년까지 10년 동안의 연속유출모의를 실시하여 물순환 분석을 하였다. 결과를 보면 10년 평균 강수량은 1537.9 mm이며, 직접유출량 비율은 1,263.0 mm, 침투량은 335.7 mm, 증발량은 415.7 mm이다. 또한 10년 평균 상수량은 909.10 mm, 하수량은 736.3 mm(CSOs 355.0 mm), 하천유입하수량은 170.3 mm, 서남 및 역곡하수처리장 이송량은 211.0 mm이다. 부하량 결과를 살펴보면 발생부하량은 10,108,554 kg/year이며 배출부하량은 834,533 kg/year으로, 이는 곧 점오염원을 의미한다. 유역 총 배출량은 1,575,200 kg/year, 비점오염원은 740,667 kg/year, 하수처리장 이송부하량은 1,220,000 kg/year, 목감천 출구지점에서는 355,200 kg/year(CSOs 62,531 kg/year)임을 알 수 있었다.

  • PDF

Effects of Disinfectant Concentration, pH, Temperature, Ammonia, and Suspended Solids on the Chlorine Disinfection of Combined Sewer Overflow (소독제 농도, pH, 온도, 암모니아 농도, 부유물질이 강우 월류수 염소 소독에 미치는 영향)

  • Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.685-690
    • /
    • 2014
  • The treatment of combined sewer overflow (CSO) is one of potential concerns in domestic wastewater treatment in Korea due to the pre-announce of CSO regulations. This work investigated the effects of disinfectant (NaOCl) concentration (0.11 to 4.0 mg $Cl_2/L$), pH (6.5 to 8.0), temperature (15 to $25^{\circ}C$), ammonia (10 to 41 mg N/L), and suspended solids (91 to 271 mg SS/L) on the chlorine disinfection of CSO. The effect of NaOCl concentration on the pseudo-$1^{st}$ order reaction rate for total coliform inactivation was described well with a saturation-type model with the half-velocity constant of 1.212 mg/L. The total coliform inactivation reaction rate decreased with SS and pH, and increased with temperature. Ammonia in the examined range did not affect the disinfection kinetics. A chlorine contact tank with the injection chlorine level of 1 mg $Cl_2/L$ and the hydraulic retention time of 1.25 min is estimated to reduce total coliform from $1{\times}10^5MPN/mL$ to 1,000 MPN/mL at 271 mg SS/L, $15^{\circ}C$, and pH 8.0. Chlorine would be a proper option for the disinfection of CSO.

Effect of separation walls on reduction of suspended solids loading in a combined sewer system (합류식 하수관거내 우오수분리벽 설치에 따른 부유물질 제어효과)

  • Kwon, Chungjin;Lim, Bongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.787-796
    • /
    • 2012
  • The purpose of this study is to investigate CSOs(combined sewer overflows) control in the combined sewer with/without separation wall. There is the high correlation between sewage velocity and suspended solid(SS) loading in the sewer without it. The SS/BOD ratio was about 3 times in the area with it, while it was about 5 times in the area without it. Therefore, the accumulated deposit within the sewer has influenced high SS loading in the sewer without it. This study showed that the separation wall installed acquired an acceptable efficiency in controlling the accumulated deposit in the combined sewer. According to this study, the BOD control effect was about 38 % in the sewer with the separation wall, whereas it showed about 24 % in the sewer without it. In this case, it was anticipated that the high pollutant control effect would be expected if the separation wall was installed in the combined sewer.