The Impact of a Basic Environmental Facility Siting on Land Prices : A Case of Sewage Disposal Plant (환경기초시설의 입지가 지가에 미치는 영향 : 하수처리장을 사례로)

  • JUN, Byong-Woon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.3
    • /
    • pp.170-180
    • /
    • 2017
  • This research analyzed the effect of a basic environmental facility siting on the difference in land prices using a case study of Jisan sewage disposal plant in Daegu metropolitan city. To do so, two buffer zones were generated around Jisan sewage disposal plant to 400m at an interval of 200m as a setback distance and 822 officially announced individual land prices were acquired from Korea Ministry of Land, Infrastructure and Transport(MOLIT). Paired samples t-test was performed to compare the mean difference in land prices before and after Jisan sewage disposal plant siting. Results show that the mean land price from each buffer zone was slightly increased after the siting and the difference was statistically significant. Also, the results indicate that the mean land price within 200m was lower than that between 200m and 400m before the siting while there was not different in the mean land price for both buffer zones after the siting. Because Jisan sewage disposal plant did not have a stench and a larger capacity and its surrounding areas were blended by commercial and residential uses, a sewage disposal plant siting had little effect on the fall in land prices unlike previous studies. The findings from this research will provide new reference data for local government and local people with conflicting views on the siting of a basic environmental facility.

A Study on Odor Emission Characteristics of Domestic Sewage Treatment Facilities Using Composite Odor Concentration and Hydrogen Sulfide Concentration (복합악취 농도와 황화수소 농도를 이용한 국내 하수처리시설의 악취발생 특성에 대한 연구)

  • Ko, Byung-Churl;Lee, Jong-Kuk;Lee, Yoon-Su;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1379-1388
    • /
    • 2012
  • Odor from sewage treatment plants have the potential to cause significant annoyance and to impact the amenity. In this study, odor emission characteristics at unit process of 48 sewage treatment facilities in 39 plants were evaluated using composite odor concentration and hydrogen sulfide ($H_2S$) concentration. The values of composite odor concentration (geometry mean) and $H_2S$ concentration (median) for sludge treatment processes are higher than those for the other treatment processes. The composite odor concentration and $H_2S$ concentration are distributed over a wide area in each process. Composite odor concentration (dilution ratio) was found to have the significant correlation with $H_2S$ concentration (p=0.000<0.05). The $H_2S$ concentration accounted for 67.1% of composite odor concentration.

A study on the Optimization of Sewage Sludge-based Adsorbent Carbonization Condition for Improving Adsorption Capacity of Hydrogen Sulfide (H2S) (황화수소(H2S) 흡착성능 증진을 위한 하수슬러지 기반 흡착제 탄화조건 최적화 연구)

  • Choi, Sung Yeol;Jang, Young Hee;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.765-771
    • /
    • 2018
  • In this study, the optimization of carbonization conditions in manufacturing processes was performed to improve the absorption performance of sewage sludge based sorbent used for treating $H_2S$ out of all odorous substances generated by various environmental facilities. Adsorbents applied were manufactured from the sewage treatment plant under different carbonization conditions, such as temperature and heating rate, and the correlation between the adsorption performance and physical properties of the adsorbents was verified. As a result, the adsorption performance of sludge at $900^{\circ}C$ with a heating rate of $10^{\circ}C/min$ was the best, and the SEM and BET analysis revealed that specific surface area and characteristics of pore (size, volume) were major parameters for the adsorption. In addition, the effect of K ions used for improving the adsorption performance of the optimum carbonization condition sorbent was insignificant for the sewage sludge based sorbent.

A Study on the Distribution of Atmospheric Concentrations of Sulfur Compounds by GC/FPD (GC/FPD에 의한 대기 중 황화합물 농도분포에 관한 연구)

  • Yang, Sung Bong;Yu, Mee Seon;Hwang, Hee Chan
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.240-248
    • /
    • 2003
  • Sulfur compounds which are well-known odor-active compounds in industrial area have very low detection threshold values. Trace amounts of volatile sulfur compounds in enviroment air around several odor sources were concentrated in liquid argon bath and determined by gas chromatograph with flame photometric detector (FPD) which exhibits very good selectivity and sensitivity. 25% ${\beta}$,${\beta}$-Oxydipropionitrile on 60/80 Chromosorb W was used as adsorbent for the preconcentration of sulfur compounds in air sample and also as packing material for a packed glass column. Concentration volume of air sample was different from place to place in the range of 0.1~3.0L. Atmospheric concentrations of sulfur compounds in air of residential districts and boundaries of business establishments, and also those in the exhausted gases of emission points such as a sewage disposal plant in industrial area were measured.

Odorous Gas Removal in Biofilter with Powdered Activated Carbon and Zeolite Coated Polyurethane Foam (분말활성탄 및 제올라이트 담지 폴리우레탄 담체를 이용한 바이오필터에서의 악취가스 제거)

  • Lee, Soo-Chul;Kim, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.209-215
    • /
    • 2012
  • The performance and removal efficiencies of a pilot scale biofilter were estimated by using ammonia and hydrogen sulfide as the odorous gases. Expanded polyurethane foam coated with powdered activated carbon and zeolite was used as a biofilm supporting medium in the biofilter. Odorous gases from the sludge thickener of a municipal wastewater treatment plant were treated in the biofilter for 10 months and the inlet ammonia and hydrogen sulfide concentrations were 0.1-1.5 and 2-20 ppmv, respectively. The removal efficiencies reached about 100% at the empty bed retention time (EBRT) of 3.6-5 seconds except for the adaptation periods. The pressure drop of the biofilter caused by the gas flow was also low that the maximum attained was 31 mm $H_2O$ during the operation. Its stability was confirmed in the long term due to the fact that the biofilter and the polyurethane medium had a minimum plugging and compression. The microbial community on the medium is critical for the performance of the biofilter especially the distribution of ammonia oxidizing bacteria (AOB) and sulfur oxidizing bacteria (SOB). The distribution of Nitrosomonas sp. (AOB) and Thiobacillus ferroxidans (SOB) was confirmed by FISH (fluorescence in situ hybridization) analysis. The longer the operation time, the more microbial population observed. Also, the medium close to the gas inlet had more microbial population than the medium at the gas outlet of the biofilter.

Development and Performance of Cutting and Crushing Instrument of Hair to Prevent Blocking U-trap in Home Drainage System (하수구 막힘 방지를 위한 모발 절단 분쇄 장치 개발 및 성능평가)

  • Kim, Donhue
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.394-399
    • /
    • 2013
  • The recalcitrant hairs which are accumulated in the U-trap equipped to prevent the stench from the drainage produce the phenomenon of blocking the flow of water through the home drainage pathway. The chemical dissolution solutions commercially manufactured are excessively poured into U-trap to solve this blocking problem. In this study, the specially designed instrument was developed for the experiments to cut and crush the hairs of which main component are the recalcitrant keratin proteins. The performance of the instrument for cutting and crushing hairs was investigated using experimental methods. The cutting and weighing method was used in order to obtain the average length of a large amount of hairs cut by instrument. This method is relatively simple to measure the weight of cutting hairs to obtain the average length of the fibers, the values of average length showed not greater tolerances. Also the average cutting number was defined to evaluate the performance of the cutting and crushing instruments designed for this study. We were able to apply these evaluation methods to provide the criteria to obtain the optimal structure of instrument and proper operation time in the given experimental conditions. These experimental methods and results will provide the good example to design and to analyze the various device that can be used for cutting the fibers. The cutting and crushing instrument developed in this study showed the effective abilities to cutting the hairs. The general using the cuttting and crushing instrument at every home would be helpful to prevent water environmental pollution.

Characterization of Repairing Polyurethane for Trenchless Sewer Pipeline (비굴착 하수관로용 폴리우레탄 보수재 특성 평가)

  • Park, Jun-Ha;Jeon, Sang-Ryeol;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3542-3547
    • /
    • 2015
  • There is commonly used the full depth excavation method of sewer pipeline maintenance in Korea. This induces couple of technical and social problems like increase of construction cost and time for excavation and backfill, increase of public complains and delay of traffic, and so force. In order to overcome these problems, lots of laboratory tests were carried out for sewer pipeline of maintenance materials with trenchless methods. The testing materials are liquid and hardened polyurethane, and polyurethane CIPP. The lab tests were followed by Korean Standard. There are no side effects, like harmless to the human body and air pollution with stink. Judging from the limited test results, all the items tested were satisfied the KS criteria.

The Effect of Water Quality Improvement by Supply of Reused Water in Urban Stream (도시하천 내 재이용수 공급에 따른 수질 개선 효과)

  • AN, SONG HEE;JANG, DONG WOO;KIM, DAE WOONG;CHOI, YE JI
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.212-212
    • /
    • 2020
  • 도시하천의 경우 비 강우시 하천의 유지용수가 부족하고, 도시지역에서 유입되는 오염물질로 인하여 수질악화, 악취 등의 문제가 발생하고 있다. 최근 생태하천 및 친수 공간에 대한 관심이 증가하고 있고, 이에 정부는 도시하천 복원사업을 적극적으로 추진하여 수환경개선을 위한 많은 노력을 기울이고 있다. 굴포천은 인천 부평구에서 경기도 김포시로 이어져 있는 국가하천으로서 수질 향상 및 유지용수 확대를 위한 굴포 하수처리수의 재이용수 활용 계획이 수립되었다. 이에 2019년 3월 자연생태하천 조성사업이 준공되었고, 굴포하수처리수에 오존처리과정을 거친 유지용수가 굴포천 상류부에 공급되고 있다. 본 연구에서는 굴포천 내 오존처리 재이용수 공급 전·후의 수질 개선 효과를 분석하기 위하여 하천수 수질기준을 활용하여 계절 별 주요 수질인자의 농도를 정량적으로 비교하였다. 유지용수 방류지점과 굴포하수처리수 방류 위치를 기준으로 굴포천 내 해석구간을 나누고, 재이용수 공급전·후 각 1년에 대하여 주요 수질을 분석하였다. 하천수 수질환경기준에 사용되는 DO, BOD, COD, TOC, SS, T-P를 중심으로 분기별 수질 분석을 한 결과, 굴포천 모든 지점에서 DO 농도는 평균적으로 증가하였고, 다른 주요 수질 인자의 농도는 감소되어 수질 개선 효과가 높은 것으로 나타났다. 분기별 하천수 수질등급 비교 결과 재이용수 공급 전 '매우 좋음(1a)'였던 수질인자는 재이용수 공급 후에도 동일 등급을 유지하였고, 모든 수질 항목에서 계절에 따른 편차가 있었지만 재이용수 공급 이후 모든 수질등급이 향상된 것으로 나타났다.

  • PDF

The Study on the Odor Removal of Digested sludge using BIO-CLOD (BIO-CLOD를 이용한 소화슬러지의 악취저감에 대한 연구)

  • Sung, Il-Wha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8665-8672
    • /
    • 2015
  • In this study, to investigate the feasibility of malodorous substance and organic matter removal by digest sludge in sewage treatment plants, ammonia, methyl mercaptan(MMC), and hydrogen sulfide($H_2S$) in a reactor submerged with BIO-CLOD(BIO-CLOD) and a reactor not submerged with BIO-CLOD(Non BIO-CLOD) were measured at 24 hours, 48 hours, and 72 hours after the submergence of BIO-CLOD. Whereas the reactor in which BIO-CLOD was submerged showed an ammonia removal rate of 48% and high $H_2S$ and MMC removal rates exceeding 98% in 24 hours, the reactor in which BIO-CLOD was not submerged showed an ammonia removal rate of 45%, an $H_2S$ removal rate of 71%, and an MMC removal rate of 84% in 24 hours indicating the possibility of removal of malodor using BIO-CLOD. A nitrification was shown in which ammonia concentrations decreased over time while nitrate nitrogen concentrations increased and sulfur based malodor components were oxidation decomposed indicating that BIO-CLOD had effects to increase sulfate concentrations in the solution and that sulfate concentration increases and atmospheric $H_2S$ removal rates were correlated with each other. With regard to decreases in organic matter in reactor effluents, BIO-CLOD did not affect in a short period of time and when reactors were operated with HRT 12 hours and HRT 24 hours, HRT 12 hours was considered desirable in terms of economy.

Odor Reduction Technology in Sewage Treatment Facility Using Biofilter with Reed Grass(Phragmites australls) (갈대(Phragmites australls)수초를 적용한 바이오필터에서의 하수처리시설 악취저감기술)

  • Chung, Jin-Do;Kim, Kyu-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.373-382
    • /
    • 2013
  • In this study, a biological odor treatment system was proposed to remove odor(foul smell) materials causing several problems in the closed sewage treatment plant. This odor treatment system was composed of a two-step biofilter system in one reactor. The two-step biofilter reactor was constructed with natural purification layer in upper part and artificial purification layer in lower part. The reed grasses of water purification plants were planted in the surface area and mixed porous ceramic media were filled with the lower part of biofilter reactor. By using the above experimental apparatus, the ammonia gas removal efficiency was attained to 98.3 % and the hydrogen sulfide gas removal efficiency was appeared more than 97.7 % which shows more effective than the conventional odor removal process.