• Title/Summary/Keyword: 하부층 강성

Search Result 46, Processing Time 0.026 seconds

Comparison of Super Structure-Sub Structure Separation Analysis and Unification Analysis about Building Structures (건축구조물의 상부구조-하부구조 분리해석과 일체해석의 비교분석)

  • Kim, Jae-Yo;Kim, Jin-Yong;Kang, Su-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.19-28
    • /
    • 2016
  • In the case of structural analysis for building structures, the super-structure and the sub-structure are analyzed by using separate structural models in the field because of time saving, facile result interpretation and easy analysis of dynamic behavior. However this separate structural model violated the compatibility condition of structural analysis and it can not consider the interaction of superand sub- structures. In the present study, the analysis results of this separate model were compared to those of the unified model of super- and sub- structures which can consider the interaction of super- and sub- structures and reflect the realistic boundary conditions. According to the comparison results, the the analysis model using separate models can underestimate the member force and deflection of structural members in the super-structures and overestimate the deflection and member force of sub-structures. Therefore, in the case of high-rise buildings, irregular shaped buildings, buildings which are expected to be affected by large differential settlement and remodeling buildings, the unified structural model for super- and sub- structures was recommended for structural analysis instead of the separate structural model.

Optimum Design of Viscoelastic Layered Beam to Minimize Flexural Vibration (굽힘진동 감쇠를 위한 점탄성 적층보의 최적 설계)

  • Sa-Soo Kim;Dae-Seung Cho;Min-Woo Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.1
    • /
    • pp.90-98
    • /
    • 1999
  • For the control of vibration and noise of metal structures having relatively low damping, viscoelastic materials are widely used and usually attached at metal structures with an additional constraining layer to secure them. The damping and elastic properties of structures having constrained viscoelastic material layers are dependent on not only temperature and frequency but also their thicknesses. Hence, optimal design of the thicknesses of viscoelastic and constraining layers for a certain base structure are very important to maximize their efficiency and to lighten their weight. In this study, the variation of loss factor of beams having a constrained viscoelastic layer according to the change of thickness has been carefully investigated. From these, optimal design method of the minimum thickness beam having a given loss factor is suggested and numerically verified for a real beam.

  • PDF

Non-linear Time History Analysis of Piloti-Type High-rise RC Buildings (필로티형 고층 RC건물의 비선형시간이력해석)

  • Ko, Dong-Woo;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.35-43
    • /
    • 2009
  • Two types of piloti-type high-rise RC building structures having irregularity in the lower two stories were selected as prototypes, and nonlinear time history analysis was performed using OpenSees to verify the analysis technique and to investigate the seismic capacity of those buildings. One of the buildings studied had a symmetrical moment-resisting frame (BF), while the other had an infilled shear wall in only one of the exterior frames (ESW). A fiber model, consisting of concrete and reinforcing bar represented from the stress-strain relationship, was adapted and used to simulate the nonlinearity of members, and MVLEM (Multi Vertical Linear Element Model) was used to simulate the behavior of the wall. The analytical results simulate the behavior of piloti-type high-rise RC building structures well, including the stiffness and yield force of piloti stories, the rocking behavior of the upper structure and the variation of the axial stiffness of the column due to variation in loading condition. However, MVLEM has a limitation in simulating the abrupt increasing lateral stiffness of a wall, due to the torsional mode behavior of the building. The design force obtained from a nonlinear time history analysis was shown to be about $20{\sim}30%$ smaller than that obtained in the experiment. For this reason, further research is required to match the analytical results with real structures, in order to use nonlinear time history analysis in designing a piloti-type high-rise RC building.

K-Ar Ages of the Volcanic Rocks from the Cretaceous Strata in Gurye Area, Jeonnam Province, South Korea (전남 구례지역의 백악기층에 나타나는 화산암에 대한 K-Ar 연대)

  • Park, Ju-Hyun;Park, Da-Hyun;Won, Beom-Hee;Kang, Sung-Seung;Kim, Cheong-Bin
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.27-35
    • /
    • 2015
  • This study aims to establish the age of the Cretaceous Togeum Formation in Gurye that reported the discovery of dinosaur eggshells and bones. This study also investigates to determine the period of the dinosaurs' dominance in the region. K-Ar ages are measured on the whole volcanic rocks in the lower - and upper parts of the formation. The six samples dated are volcanic pebbles deposited in the Geumjeongri Conglomerate that is distributed underneath the Togeum Formation, and the ages dated as Aptian ($118.3{\pm}2.3Ma$) or Albian ($103.6{\pm}2.0$, $102.5{\pm}2.0$, $99.9{\pm}1.9Ma$), which all correspond to the Early Cretaceous. In addition, the ages of andesites and porphyritic andesites overlying the Togeum Formation are dated in a similar way. The result is that the ages are apparently corresponding to the Campanian ($83.9{\pm}1.6$, $74.2{\pm}1.5$Ma) of the Late Cretaceous. Field evidence and the age results indicate that the formation of the Togeum and the activities of dinosaurs dated back between 84 and 100Ma. It suggests that the Togeum Formation be somewhat older than the Boseong Seonso Formation (81Ma) which contains egg shells, the Haenam Uhangni Formation (79-81 Ma) that has dinosaur, pterosaur and webbed bird footprints, and also older than the theropod egg nests (77-83Ma) found in the Aphaedo area.

Sensitivity Analysis of Load Trunsfer of Jointed Concrete Pavements Using 3-D Finite Element Model (3차원 유한요소 모형를 이용한 줄눈 콘크리트포장 하중전달의 민감도 분석)

  • Sun, Ren-Juan;Lim, Jin-Sun;Jeong, Jin-Hoon
    • International Journal of Highway Engineering
    • /
    • v.10 no.2
    • /
    • pp.145-157
    • /
    • 2008
  • Load transfer efficiency (LTE) reflects the structural performance of doweled and undoweled joints of Jointed Concrete Pavement (JCP). A 3-dimensional (3-D) model of JCP was built using ABAQUS software in this study. Three concrete slabs were placed on bonded sublayers composed of a base and subgrade. Spring elements were used to connect the adjacent slabs at joints. Different spring constants were input to the model to simulate different joint stiffness of the concrete pavement. The LTE of the joint increased with an increase of the spring constant. The effects of material properties and geometric shape on the behavior of JCP were analyzed using different elastic modulus and thickness of the slab and base in the modeling. The results showed the elastic modulus of the subgrade affected the behavior of the slab and LTE more than that of the base and the thickness of the slab and base. The effects of a negative temperature gradient on the behavior of the slab and LTE were more than that of positive and zero temperature gradients. Joints with low stiffness were more sensitive to the temperature gradient of the slab.

  • PDF

Hydraulic Conductivity and Strength Characteristics of Self Recovering Sustainable Liner (SRSL) as a Landfill Final Cover (SRSL 매립지 최종 복토층의 투수 및 강도 특성)

  • Kwon, Oh-Jung;Lee, Ju-Hyung;Cho, Wan-Jei;Jung, Young-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.12
    • /
    • pp.5-15
    • /
    • 2011
  • Conventional designs of landfill covers use geosynthetics such as geomembrane and GCL, and clay liners to lower the permeability of final covers of landfill sites. However, differential settlement and the variation of temperature or humidity in landfill sites cause the development of cracks or structural damage inside the final cover. This study examined the application of a Self Recovering Sustainable Liner (SRSL) as an alternative landfill final cover material. SRSL consists of double layers, which have chemicals, can generate precipitates filling the pores of the layers by chemical reaction. The interface material forms an impermeable layer and in case of internal cracks, the reactants of the two layers migrate towards the crack and heal it by forming another liner. In this study the applicability of SRSL material for landfill final cover was examined by performing flexible wall permeameter tests to prove that the hydraulic conductivity is lower than the regulations and unconfined compression tests to judge whether the strength satisfies the restriction for the landfill final cover. Furthermore, the environmental impacts on the permeability and strength were evaluated. The experimental results show that the SRSL has lower hydraulic conductivity and higher strength than the regulations and is little influenced by climatic changes such as wet/dry or freeze/thaw process.

Drainage and reinforcement of landfill leachate using drain pile (배수파일을 이용한 매립장의 침출수 배수 및 보강)

  • Shin, Joon-Soo;Park, Jun-Boum;Seo, Min-Woo;Yune, Chan-Young;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.177-184
    • /
    • 2003
  • 매립장 내의 설치된 중간 복토층(intermediate cover)은 매립 도중 혹은 매립완료 후 종종 침출수가 하부의 침출수 집배수관으로 이동하는 것을 막아 매립장 내에 일정 침출수위를 형성시킨다. 이렇듯 중간 복토층은 침출수의 원활한 순환을 막아 매립장 바닥에 형성되어야 하는 침출수위가 중간복토층 위에 형성되도록 하는데, 이는 매립장의 구조적 안정성을 깨뜨리고 주변으로 침출수 누출을 유발시키게 된다. 본 연구에서는 이처럼 중간복토층 상부에 형성된 침출수위를 저하시키기 위하여, 폐기물 매립시 중간복토층에 투수성이 뛰어나고 역학적 강도와 화학적 내구성을 갖는 배수파일(Drain Pile)을 설치할 것을 제안하였다. 배수파일은 중간복토층 상부에 형성될 수 있는 침출수를 매립장 바닥으로 배수시키고, 침출수 집배수정으로 이송이 가능하게 만든다. 또한 배수파일은 매립장 내부에 설치됨으로써 폐기물의 자체 강성을 증가시키고, 동시에 매립장의 측방유동을 막아 구조적 안정성을 확보하는 효과도 기대할 수 있다. 실내시험을 통해 배수파일 충진재로서 굴패각의 활용가능성을 확인한 결과, 산업 폐기물인 굴패각이 침출수의 pH를 중화시키고 유해물질인 NH$_{4}$$^{+}$를 제거하는데 효과적임을 확인할 수 있었다. 한편, 실제현장의 침출수흐름을 모사하기 위해 범용 프로그램(SEEP/W)을 이용하여 매립지 내에서 배수 파일의 효과를 확인하였다.

  • PDF

A Hystesis Loop Modeling of Ferroelectric Thin Film Using Numerical Integration Method (수치적분을 이용한 강유전체의 이력곡선 모델링)

  • 강성준;정양희;유일현
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.696-699
    • /
    • 2003
  • In this study, we suggested the model to precisely evaluate the ferroelectric hysteresis loop, using the modified Sawyer-Tower circuit and the ferroelectric capacitor with a MDFM(Metal-Dielectric-ferroelectric-Metal) structure. The mathematical expression of dipole polarization is applied to the numerical integration algorithm, and the fatigue property can be considered including the dielectric layer between ferroelectrics and bottom electrode. The validity of our model is proved comparing the estimated value of our model and the measured results of PLT(10) thin film.

  • PDF

Effects of Shore Stiffness and Concrete Cracking on Slab Construction Load I: Theory (슬래브의 시공하중에 대한 동바리 강성 및 슬래브 균열의 영향 I: 이론)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Hong, Geon-Ho;Im, Ju-Hyeuk;Kim, Jae-Yo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • Long-term floor deflection caused by excessive construction load became a critical issue for the design of concrete slabs, as a flat plate is becoming popular for tall buildings. To estimate the concrete cracking and deflection of an early age slab, the construction load should be accurately evaluated. The magnitude of construction load acting on a slab is affected by various design parameters. Most of existing methods for estimating construction load addressed only the effects of the construction period per story, material properties of early age concrete, and the number of shored floors. In the present study, in addition to these parameter, the effects of shore stiffness and concrete cracking on construction load were numerically studied. Based on the result, a simplified method for estimating construction load was developed. In the proposed method, the calculation of construction load is divided to two steps: 1)Onset of concrete placement at a top slab. 2)Removal of shoring. At each step, the construction load increment is distributed to the floor slabs according to the ratio of slab stiffness to shore stiffness. The proposed method was compared with existing methods. In a companion paper, the proposed method will be verified by the comparison with the measurements of actual construction loads.

Evaluation of Shallow Foundation Behavior on Basalt Rock Layers With Clinker and Sediment Layers Reinforced Using Cement Grouting (현무암층 사이에 존재하는 클링커층과 퇴적층의 시멘트 그라우팅 보강에 따른 얕은 기초 거동 평가)

  • Lee, Kicheol;Shin, Hyunkang;Jung, Hyuksang;Kim, Donghoon;Ryu, Yongsun;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.3
    • /
    • pp.33-44
    • /
    • 2019
  • Clinker layer is a stratum structure distributed in volcanic area such as Jeju Island. The clinker layers were formed in between the repetitive action of eruption and solidification of lava flows. Since the clinker layer contains a large amount of voids accompanied by the lava gas ejection process, there is a possibility of inducing overall stability of the ground due to the low stiffness and strength of the clinker layer. Therefore, in this study, site investigation was carried out at both ends of the 00 bridge where the clinker layers exist. And, based on the ground survey results, the behavior of shallow foundations was analyzed numerically. In addition, the improved shallow foundation behavior in grouting substitution using the chemical injection method of the clinker layer was compared with the shallow foundation behavior in the ground, and the grouting substitution efficiency of each layer was analyzed. As a result, the bearing capacity, the replacement efficiency and elastic settlement were different according to the presence or absence of the sediment layer. This is because the sediment layer has a lower stiffness and density than the clinker layer.