• Title/Summary/Keyword: 하부지지구조물

Search Result 78, Processing Time 0.025 seconds

Numerical Analysis of the Effect of Hole Size Change in Lower-Support-Structure-Bottom Plate on the Reactor Core-Inlet Flow-Distribution (하부지지구조물 바닥판 구멍크기 변경이 원자로 노심 입구 유량분포에 미치는 영향에 관한 수치해석)

  • Lee, Gong Hee;Bang, Young Seok;Cheong, Ae Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.11
    • /
    • pp.905-911
    • /
    • 2015
  • In this study, to examine the effect of a hole size change(smaller hole diameter) in the outer region of the lower-support-structure-bottom plate(LSSBP) on the reactor core-inlet flow-distribution, simulations were conducted with the commercial CFD software, ANSYS CFX R.15. The predicted results were compared with those of the original LSSBP. Through these comparisons, it was concluded that a more uniform distribution of the mass flow rate at the core-inlet plane could be obtained by reducing the hole size in the outer region of the LSSBP. Therefore, from the nuclear regulatory perspective, design change of the hole pattern in the outer region of the LSSBP may be desirable in terms of improving both the mechanical integrity of the fuel assembly and the core thermal margin.

A Study on the Influence of a supporting structure on the Seismic Response of a Roof Structure (하부구조가 지붕구조의 지진응답에 미치는 영향에 관한 연구)

  • Jung, Chan-Woo;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.63-74
    • /
    • 2007
  • Large spatial structures consist of roof structure and its supporting structure. Authors simply call the supporting structure "lower parts" and roof structure "upper parts". To study the influence of an lower part on the seismic response of the upper part of a structure as a first step, authors substitute the upper part and the lower part of the structure to a single degree of freedom system individually, and set up a new 2 DOF structural model connected by them. It is clarified that the mass ratio and the period ratio of an upper part to a lower part are important parameters to find the amplification or reduction of the seismic response of an upper part.

  • PDF

Vibration Reduction Evaluation of Jacket Structure by applying Precast Concrete Block and Suction pile (Precast Concrete Block 및 Suction pile을 적용한 Jacket 구조물의 진동저감 효과 평가)

  • Lee, Sung-Jin;Kyung, Kab-Soo;Ryu, Seong-Jin;Jeong, Ji-Young;Park, Jin-Eun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.4
    • /
    • pp.375-384
    • /
    • 2015
  • Recently, construction sites of offshore wind power tend to move from shallow water to deep water. From this tendency, the research on the support structure of offshore wind power in deep water will be a key issue. In this study, precast concrete block and suction pile are applied to existing jacket structure. In order to reduce the vibration of this structure, the tuned liquid damper is also applied in the precast concrete block. The applicability of the suggested jacket structure is evaluated by finite element analysis. And the vibration tends to decrease about 5%, when the tuned liquid damper is applied.

Seismic Behavior of the Spacial Structure with Seismic Isolation (면진장치를 적용한 대공간구조물의 지진응답 분석)

  • Kim, Gee-Cheol;Ju, Dong-Hyem
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.49-57
    • /
    • 2008
  • The seismic isolation systems could be used to reduce the seismic response of a structure. The natural period of a structure with seismic isolation system got be long to avoid the prominent seismic period. The purpose of this study is to analyzed the seismic behavior of the truss arch that is supported to column with LRB. Truss arch structures subjected to horizontal seismic have large horizontal and vertical response unlike seismic behavior of normal rahmen structures. When seismic load is applied to the truss arch with isolation systems, the horizontal acceleration response of the truss arch is reduced and the vertical seismic response is remarkably reduced. Also, the seismic behaviors of the truss arch with strengthen column as like lattice column are very similar to that of the truss arch supported to directly foundation. The Seismic Isolation system can be applied to reduce efficiently the seismic response of the spacial structure with not strong column.

  • PDF

Development of the Nondestructive Methods to Detect Voids under Concrete Slabs Using Wave Analysis (파동해석법을 이용하여 콘크리트 슬래브 하부의 공동을 찾는 비파괴 시험법의 개발)

  • Kim, Yongon;Kim, Y. Richard
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.1
    • /
    • pp.108-120
    • /
    • 1998
  • 많은 주거용 및 상업용 건물에서 콘크리트 구조물이 사용되고 있는데 콘크리트 슬래브 아래의 기초부분에 공동이 생기는 경우가 종종 발견되었다. 이 현상은 진동하중, 반복되는 충격, 흙의 유실, 혹은 불량시공 등 여러가지 이유에 의해 발생할 수 있다. 이러한 현상은 구조물의 지지력을 저하시키고 결국 수명을 단축시키는 원인이 되므로 이러한 문제는 일찍 발견되고 조치가 취해질수록 구조물의 수명을 연장시킬 수 있을 것이다. 이러한 공동이 슬래브 아래에서 형성되고 커져가는 과정을 모니터할 수 있으면 현재 상태에서 지지력을 결정하고 또한 앞으로 남은 수명을 예측함으로써 적절한 유지보수계획을 세우는 데에 큰 도움이 될 것이다. 이 연구에서는 음파와 응력파, 특히 표면파가 슬래브 아래의 공동을 찾아내는데 이용되었고 두 가지 방법의 효과가 상호 비교되었다. 두개의 콘크리트 슬래브를 만들어 이용했는데 하나는 미리 공동이 만들어져 있었고 다른 하나에는 공동이 없었다. 공동이 없던 슬래브는 처음 손상안된 상태에서 실험을 한 후 나중에 하부에 공동을 만들어 다시 실험하였다. 실험결과와 실제 공동의 위치가 잘 일치되는 것으로 나타났다. 응력파를 이용하는 방법과 음파를 이용하는 방법사이의 장단점이 비교검토되었고 실험의 표준방법과 결과에 대한 일반적인 기준이 확립되어야 하는 필요성에 대해서도 설명되었다.

  • PDF

Stability Evaluation Along Interface Loss of a Foundation and the Ground (기초와 지반의 접촉면 손실에 따른 지지력 안정성 평가)

  • Kim, Sang-Hwan;Ji, Tal-Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.178-185
    • /
    • 2010
  • This paper presents the evaluation of foundation stability according to decrease of the foundation contact area on the ground. In order to carry out this research, the experimental and numerical studies are performed. In the experimental study, the carefully controled laboratory model tests are carried out with different foundation size and types. The model test results are analyzed and interpreted by analytical and numerical calculation in order to verify both results obtained from experimental and numerical studies. It is clearly found from the results that the foundation stability is considerably reduced when the foundation contact area ratio is less than 75%. This research may be very useful to develop the economical foundation type.

Development of Three-dimensional Interactive Analysis for Superstructure-piled raft foundation (구조물-말뚝지지 전면기초의 3차원 상호작용 해석기법 개발)

  • Cho, Jae-Yeon;Jeong, Sang-Seom;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.6
    • /
    • pp.19-31
    • /
    • 2013
  • In engineering practices, the superstructure was analyzed under a fixed boundary condition and the foundation was designed by considering the loading condition of superstructure. It may result in overestimation of forces, the bending moment, settlement of superstructure and foundation. In this study, an interactive analytical method is proposed for the interaction between the superstructure and the piled raft. The overall objective of this study is focused on the application of interactive analysis method for predicting behavior of entire structures. And a series of numerical analyses are performed to verify the interactive analysis routine in comparison to the unified analysis method. Through the comparative studies, it is found that the iterative and interactive analysis gave similar results of settlement and raft bending moment compared with those of finite element analysis. And it is also found that the proposed design method considering interaction between superstructure and foundation is capable of predicting reasonably well the behavior of entire structures. It can be effectively used to the design of a superstructure-piled raft foundation system.

A Study on The Behavior of Very Large Floating Structure Using Pneumatic Stabilized Platform (공기안정식 초대형부유구조물의 거동에 관한 연구)

  • Hong, Sang-Hyun;Kwon, Dong-Ho;Lee, Seung-Jun;Lee, Jong-Seh
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.133-136
    • /
    • 2010
  • 공간부족과 해안 매립으로 발생되는 문제점을 해결하기 위하여 초대형부유구조물이 각광 받고 있으며, 대표적인 구조형식으로는 폰톤식과 반잠수식이 있다. 하지만 다양한 환경에 적용하기에는 구조적으로 한계를 가지고 있으며, 이를 극복하기 위해 부유체 하부에 수직으로 결합된 실린더에 공기를 가두어 지지되는 공기안정식 플랫폼이 제안되어졌으나 아직 개념단계에 머무르고 있는 실정이다. 이에 본 연구에서는 공기 안정식 초대형부유구조물의 실린더 내부 공기상태에 따른 안정성을 검토하기 위하여 유체정역학적 관계를 통해 실린더 내부의 공기 복원력 변수를 산정하였으며, 선형파랑하중에 따른 구조물의 응답을 최소화 할 수 있는 변수의 범위를 제시하였다.

  • PDF

Analysis of Semi-Rigid Connections on 3D Floating Structures (3차원 플로팅 구조물의 반강접 접합부 해석)

  • Park, Jong-Seo;Song, Hwa-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.36 no.3
    • /
    • pp.175-180
    • /
    • 2012
  • The shape of floating superstructure is the same as other buildings, but the foundation is based not on land but on a floating body. Unlike inland structures, they are largely influenced by the wave load. Deformation of the floating pontoon due to the wave loads affects the connection, which in turn causes problems related to the habitability and safety to the superstructure users. Accordingly, this study conducted elastic analysis regarding rigid connection and semi-rigid connection by the integration analysis that combined together the superstructure and pontoon of the 3-D floating structure. Moreover, this study investigated the results of the separation analysis excluding pontoon and the integration analysis. In addition, elasticity analysis was used to divide up the wave loads cases, and to classify the moment and displacement of the structure depending on connection following the changes in the wave loads.

Model prediction of crosslinked chitosan composite membrane for pervaporation of water-ethanol mixtures

  • 박호범;남상용;이영무
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.04a
    • /
    • pp.65-66
    • /
    • 1996
  • 투과증발법은 상부에 액체공급액이 반투과막과 접촉하고 있고 하부에 진공에 가까운 낮은 압력을 걸어줌으로써 투과물이 수증기로 제거되는 막공정의 하나이다. 막을 통한 분리는 혼합물의 각 성분이 막내에서 다른 용해도와 확산도를 가지고 있기 때문에 발생한다. 이 공정의 지배적인 전달 메카니즘은 용해-확산 모델을 기초로 하고 있기 때문에 전형적으로 투과증발막은 대개 미세다공성 지지체에 얇은 선택성을 가진 재료를 입힌 복합막을 사용한다. 본 연구의 목적은 선택성을 가진 상부층막이 키토산인 복합막에서 지지체 구조의 영향을 살펴보고 키토산 복합막에 대한 물-에탄올 분리에 대해 최적의 모델을 찾는 것이다. 투과증발막소재로서의 키토산은 친수성기를 가지고 있으므로 물과 알코올의 분리에서 물만을 선택적으로 흡수하여 투과시키는 우수한 성능을 지니고 있으나 더욱 효과적인 막성능을 발휘하기 위해서는 지지체의 역할 및 막성능에 영향을 끼치는 여러 가지 인자들을 고려해서 막을 설계하는 것이 필요하다. 여기서는 상부층의 막두께, 지지체의 특성, 피드 농도 등을 변화시켜 가장 적당한 모델을 예측하였다.

  • PDF